Sinapsi esolar3be RS485 User manual

1.OVERVIEW
2.Connections/buttons/leds
4.POSSIBLE INSTALLATION MODES
7.ETHERNET PORTS
horizontal mounting
2
SIN.ES3BE - QuickStart Guide
SIN.ES3BE_QSG_1.0_en
Photovoltaic system efficiency and production
monitoring system. SGH-net compliant
- Datalogger with integrated web server
- Acquires up to 120 devices
- Keeps up to 2 years of 15-minute data in memory
- Powerful, compact and very low power consumption
- Acquires data from
(a) inverter
(b) string controllers
(c) energy meters
(d) interface protections
(e) general protections
(f) sensors of any kind
(g) digital inputs
- 2 isolated RS485 ports
- 1 non-isolated RS485 port
- 1 RS232 port
2
1 - Ethernet port for internet and devices
2 - Service Ethernet port and devices
3 - USB ports for backup memory devices
4 - On/Offbutton
5 - Activity LEDs
6 - Power LED
3
4
7 - 24vdc power supply connector
8 - RS232 serial port
9 - KNX Port (only active on KNX model)
10 - RS485 COM3 INSULATED port
11 - RS485 COM1 INSULATED port
12 - RS485 port NOT INSULATED
56
1
(Install at the rear
the DIN RAIL Kit - optional)
6.FIELDBUS CONNECTION
2x M4x6mm screws
DOWNLOAD DOCUMENTAZIONE: https://www.esolar.it/en/useful-documentation/
esolar 3 b.e. has 3 RS485 ports, 1 RS232 port and one KNX port (active in KNX models).
Two RS485 ports are optoisolated to offer excellent communication performance with the devices in the field
and robustness, while the COM5 is not optoisolated, so it is recommended to connect the latter to devices that
do not present particular problems of electrical disturbances or low probability of the presence of surges.
It is also recommended to always use appropriate cables for RS485 connections and connect always ground
the shield conductor on one side only (preferably on the field side).
RS485 - COM1 & COM3
Manufactured by Cincoze Co.Ltd
Before making any connection, remove the power supply and complete the wiring,
then feed the datalogger
1 x SIN.ES3BE
3.CONTENTS OF THE PACKAGE
5.POWER SUPPLY CONNECTION
To power the device use the appropriate power supply supplied with esolar 3 b.e. or one of the following
equivalent.
Connect the cables in accordance with the RS485 standard, paying attention to the impedance of the
section and in the presence of the line termination resistor. It is recommended not to exceed 300mt in
length of the RS485 network in a photovoltaic field, alternatively it is recommended to use RS485
repeaters. Respect polarities
Front
Back
NOTE: For details on the configuration of esolar 3 b.e., please refer to the manual.
vertical mounting DIN rail mounting
esolar 3 b.e. has 2 ethernet ports:
port 1 = normal use port, which can be used to connect the device to the internet, connect to the
device, connect esolar 3 b.e. to the devices in the field, the default address of this port is static and
is 192.168.1.110, it is user-modifiable.
port 2 = service port, which can be used to connect to esolar 3 b.e. and to connect the datalogger to the
devices in the field, the IP address of this port is fixed and cannot be changed: 192.168.1.100
8.ON/OFF BUTTON
- To switch on briefly press button (4), esolar 3 b.e. will be ready for operation after about 2 minutes.
- To switch offesolar 3 b.e. briefly press the button (4), after about 10...20 seconds the LED 5 and 6 will go
off, you can then disconnect the power supply. the device will automatically switch on again when the
power is restored.
9.USB PORTS
esolar 3 b.e. has 4 USB ports to which it is possible to connect an external memory to make a local backup
of the scheduled data. Choosing the USB port to insert the flash memory into outside is indifferent.
It is necessary to insert a flash memory formatted with FAT32 filesystem and of capacity of at least 8 GB.
2 x wall mounting brackets
1 x Power connector +
3 x 3-pin connector for isolated RS485 ports
7
8
910 11
RS232 - COM 4
Do not exceed 2-3 mt of length for the RS232 section and use shielded cables.
KNX port
Observe the installation rules of KNX networks, do not exceed 350mt of length and
use only KNX certified cable. Respect the polarities.
12

1) The device does not turn on:
2) WEB interface is not reached from local
3) Connected devices do not communicate with esolar 3 b.e.
Temperature range:
Degree of protection:
Dimensions:
Power supply:
12.TECHNICAL DATA
+70°C
-25°C
SIN.ES3BE_QSG_1.0_en
- Verify the presence of a voltage between 9 and 48 Vdc connector ends (7)
- Verify that the power supply is capable of delivering a current of at least 4A
- In case of RS485 connection make sure that the polarities of the line are not inverted, that the cable
length is less than 300mt and that the terminating resistors are inserted.
- Check the slave addresses of the devices to be monitored and the communication parameters
(e.g. baud rate, partià bit, stop bit).
- Check that the IP addresses of the devices you want to monitor are compatible with the network
settings of esolar 3 b.e.
(e
- Check that the IP address you entered is actually the machine's IP address (Ethernet Port 1), in the
case of If you are in doubt, it is advisable to connect to the ethernet service port (192.168.1.100)
and check the configuration
- Make sure your PC's network card is configured with a similar (and different) IP address to the
datalogger
- Make sure that the network cable and all equipment in between are working properly
- Make sure esolar 3 b.e. is turned on
DOWNLOAD DOCUMENTATION: https://www.esolar.it/download-generale/Manufactured by Cincoze Co.Ltd
10.FIRST ACCESS 13. ACTIVATION OF THE REACHABILITY SERVICE
Make sure you have your PC's network card with IP address 192.168.1.xxx where xxx should be a different
number from 100 and 110.
Connect the PC to one of the two network ports of esolar 3 b.e. and type the IP address 192.168.1.110 on your
browser if esolar 3 b.e. is connected through port 1 otherwise 192.168.1.100 if connected through port 2.
The login page will be shown:
esolar 3 b.e. has the SGHNET reachability service that allows you to access the interface
WEB of the device remotely, without the need to make portforwarding rules on the router
or firewall of the internet connection to which it is connected and also allows you to obtain
a DNS address like this even in case of dynamic IPs.
To activate the service, scan the QRCode present on the machine and log in or register on
MY SINAPSI portal that is opened. Once the procedure has been completed, you can log on
to the device with an address like: https://sn12345678.net.sghiot.com
Operating: -20°C ... +70°C
Warehouse -25°C ... +85°C
IP 40 (EN60529)
WxHxD 105x150x56mm
9..48Vdc max 4A
TROUBLESHOOTING
Enter the default login credentials: username = admin, password = admin.
At this point, we recommend that you consult the product manual to properly commission the datalogger.
11.PHYSICAL DIMENSIONS
Sinapsi reserves the right to make changes to this product without any notice
This manual suits for next models
1