Siqura Hardened Managed PoE Ethernet Switch User manual

Hardened Managed PoE Ethernet Switch
Quick Start Guide
This quick start guide describes how to install and use the
Hardened Managed PoE (Power over Ethernet) Ethernet
Switch. This is the switch of choice for harsh environments
constrained by space.
Physical Description
The Port Status LEDs and Power Inputs
User’sManual 1

Hardened Managed PoE Ethernet Switch
LED State Indication
10/100Base-TX
Steady A valid network connection established.
LINK/ACT Flashing Transmitting or receiving data.
ACT stands for ACTIVITY.
Steady Power Device (PD) is connected.
PoE Off Power Device (PD) is disconnected.
1000Base SFP
Steady A valid network connection established.
LINK/ACT Flashing Transmitting or receiving data.
ACT stands for ACTIVITY.
Power Input Assignment
Power3 47-57VDC DC Jack
+47-57VDC
Power2 -Power Ground
+47-57VDC
Power1 -Power Ground
Earth Ground
Terminal
Block
Relay Output Rating 1A @ 250VAC
Relay Alarm Assignment
FAULT
*Warning signal disable for following:
1.The relay contact closes if Power1 and
Power2 are both failed but Power3 on.
2.The relay contact closes if Power3 is failed
but Power1 and Power2 are both on.
User’sManual 2

Hardened Managed PoE Ethernet Switch
User’sManual 3
Functional Description
Meets NEMA TS2 Environmental requirements such as temperature,
shock, and vibration for traffic control equipment.
Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity
for industrial environment.
RS-232 console, Telnet, SNMP v1 & v2c & v3, RMON, Web Browser,
and TFTP management.
Supports Command Line Interface in RS-232 console.
Supports 8192 MAC addresses. Provides 2M bits memory buffer.
Supports IEEE802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation,
1000Mbps-full-duplex, 10/100Mbps-full/half-duplex, Auto MDI/MDIX.
The C4208SW PoE is equipped with 2x 1000Base-FX SFP slots.
Store-and-forward mechanism. Full wire-speed forwarding rate.
Alarms for power and port link failure by relay output.
Power Supply: Redundant 47-57VDC Terminal Block power inputs or
47-57VDC DC Jack power input.
Field Wiring Terminal: Use Copper Conductors Only, 60/75°C, 12-24
AWG torque value 7 lb-in.
Operating voltage and Max. current consumption: 0.31A @ 48VDC.
Power consumption: Power consumption: 181.6W Max. (Full load with
PoE), 15W Max. (Without PoE).
-40°C to 75°C (-40°F to 167°F) operating temperature range. Tested
for functional operation @ -40°C to 85°C (-40°F to 185°F).
For use in Pollution Degree 2 Environment.
Hardened metal case.
Supports Din-Rail or Panel Mounting installation.
<Note>
4-Port IEEE802.3at Power over Ethernet (PoE) Power Sourcing
Equipment (PSE) and 4-Port IEEE802.3af Power over Ethernet (PoE)
Power Sourcing Equipment (PSE) model: Port 1 ~ Port 4 supports 30W
IEEE802.3at Power over Ethernet (PoE) Power Sourcing Equipment
(PSE) and Port 5 ~ Port 8 supports 15.4W IEEE802.3af Power over
Ethernet (PoE) Power Sourcing Equipment (PSE). This product model
can suppot output power budget up to total 181.6W.

Hardened Managed PoE Ethernet Switch
Console Configuration
Connect to the switch console:
Connect the DB9 straight cable to the RS-232 serial port of the device
and the RS-232 serial port of the terminal or computer running the
terminal emulation application. Direct access to the administration
console is achieved by directly connecting a terminal or a PC equipped
with a terminal-emulation program (such as HyperTerminal) to the
switch console port.
Configuration settings of the terminal-emulation program:
Baud rate: 115,200bps
Data bits: 8
Parity: none
Stop bit: 1
Flow control: none
Press the “Enter” key. The Command Line Interface (CLI) screen should
appear as below:
Logon to Exec Mode (View Mode):
At the “switch_a login:”prompt just type in “root” and press <Enter> to
logon to Exec Mode (or View Mode). And the “switch_a>” prompt will
show on the screen.
Logon to Privileged Exec Mode (Enable Mode):
At the “switch_a>” prompt just type in “enable” and press <Enter> to
logon to Privileged Exec Mode (or Enable Mode). And the “switch_a#”
prompt will show on the screen.
Logon to Configure Mode (Configure Terminal Mode):
At the “switch_a#” prompt just type in “configure terminal” and press
<Enter> to logon to Configure Mode (or Configure Terminal Mode). And
User’sManual 4

Hardened Managed PoE Ethernet Switch
the “switch_a(config)#” prompt will show on the screen.
Set new IP address and subnet mask for Switch:
At the “switch_a(config)#” prompt just type in “interface vlan1.1” and
press <Enter> to logon to vlan 1 (vlan1.1 means vlan 1). And the
“switch_a(config-if)#” prompt will show on the screen.
Command Syntax: “ip address A.B.C.D/M”. “A.B.C.D” specifies IP
address. “M” specifies IP subnet mask. “M”= 8: 255.0.0.0,
16:255.255.0.0, or 24: 255.255.255.0.
For example, At the “switch_a(config-if)#” prompt just type in “ip address
192.168.1.10/24” and press <Enter> to set new IP address
(192.168.1.10) and new IP subnet mask (255.255.255.0) for Switch.
Web Configuration
Login the switch:
Specify the default IP address (192.168.1.10) of the switch in the web
browser. A login window will be shown as below:
User’sManual 5

Hardened Managed PoE Ethernet Switch
Enter the factory default login ID: root.
Enter the factory default password (no password).
Then click on the “Login” button to log on to the switch.
User’sManual 6

Hardened Managed PoE Ethernet Switch
User’sManual 7

Hardened Managed PoE Ethernet Switch
User’sManual 8
Preface
This manual describes how to install and use the Hardened
Managed PoE (Power over Ethernet) Ethernet Switch. This
switch introduced here is designed to deliver full scalability
with SNMP/RMON web-based management functions by
providing:
To get the most out of this manual, you should have an
understanding of Ethernet networking concepts.
In this manual, you will find:
Features on the Hardened Managed PoE Ethernet Switch
Illustrative LED functions
Installation instructions
Management Configuration
SNMP, IGMP…
Specifications

Hardened Managed PoE Ethernet Switch
User’sManual 9
Table of Contents
Quick Start Guide 1
PHYSICAL DESCRIPTION 1
The Port Status LEDs and Power Inputs 1
FUNCTIONAL DESCRIPTION 3
CONSOLE CONFIGURATION 4
WEB CONFIGURATION 5
Preface 8
Table of Contents 9
Product Overview 11
HARDENED MANAGED POEETHERNET SWITCH 11
PACKAGE CONTENTS 11
PRODUCT HIGHLIGHTS 12
Basic Features 12
Management Support 13
FRONT PANEL DISPLAY 14
PHYSICAL PORTS 15
SWITCH MANAGEMENT 16
Web-based browser interface 16
Administration console via RS-232 serial port (CLI) 16
External SNMP-based network management application 16
Installation 17
SELECTING A SITE FOR THE SWITCH 17
WIRING DIAGRAM 17
DIN RAIL MOUNTING 18
CONNECTING TO POWER 19
47-57VDC Jack 19
Redundant 47-57VDC DC Terminal Block Power Inputs 19
Alarms for Power Failure 20
CONNECTING TO YOUR NETWORK 21
Cable Type & Length 21
Cabling 22
Switch Management 23
MANAGEMENT ACCESS OVERVIEW 23
ADMINISTRATION CONSOLE (CLI) 24
Direct Access 24
WEB MANAGEMENT 25
SNMP-BASED NETWORK MANAGEMENT 25
PROTOCOLS 25
MANAGEMENT ARCHITECTURE 26

Hardened Managed PoE Ethernet Switch
User’sManual 10
Web-Based Browser Management 27
SNMP & RMON Management 28
OVERVIEW 28
SNMP AGENT AND MIB-2 (RFC 1213) 29
RMON MIB (RFC 2819) AND BRIDGE MIB (RFC 1493) 29
RMON Groups Supported 30
Bridge Groups Supported 30
Web-Based Browser Management 31
LOGGING ON TO THE SWITCH 31
UNDERSTANDING THE BROWSER INTERFACE 32
SYSTEM 34
PORT 49
SWITCHING 56
TRUNKING 61
STP /RING 63
VLAN 74
QOS 80
SNMP 83
802.1X88
OTHER PROTOCOLS 92
Command Line Console Management 102
ADMINISTRATION CONSOLE 102
Exec Mode (View Mode) 103
Privileged Exec Mode (Enable Mode) 107
Configure Mode (Configure Terminal Mode) 112
USER INTERFACE CONFIGURATION 116
SYSTEM 118
PORT 129
SWITCHING 139
TRUNKING 148
STP /RING 153
VLAN 169
QOS 175
SNMP 178
802.1X185
OTHER PROTOCOLS 190
Specifications 209
Appendix A 210
Appendix B 211

Hardened Managed PoE Ethernet Switch
Product Overview
Hardened Managed PoE Ethernet Switch
Front View
Package Contents
When you unpack the product package, you shall find the
items listed below. Please inspect the contents, and report
any apparent damage or missing items immediately to your
authorized reseller.
The Hardened Managed PoE Ethernet Switch
User’s Manual
RS-232 cable
User’sManual 11

Hardened Managed PoE Ethernet Switch
User’sManual 12
Product Highlights
Basic Features
Meets NEMA TS2 Environmental requirements such as temperature,
shock, and vibration for traffic control equipment.
Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity
for industrial environment.
RS-232 console, Telnet, SNMP v1 & v2c & v3, RMON, Web Browser,
and TFTP management.
Supports Command Line Interface in RS-232 console.
Supports 8192 MAC addresses. Provides 2M bits memory buffer.
Supports IEEE802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation,
1000Mbps-full-duplex, 10/100Mbps-full/half-duplex, Auto MDI/MDIX.
The C4208SW PoE is equipped with 2x 1000Base-FX SFP slots.
Store-and-forward mechanism. Full wire-speed forwarding rate.
Alarms for power and port link failure by relay output.
Power Supply: Redundant 47-57VDC Terminal Block power inputs or
47-57VDC DC Jack power input.
Field Wiring Terminal: Use Copper Conductors Only, 60/75°C, 12-24
AWG torque value 7 lb-in.
Operating voltage and Max. current consumption: 0.31A @ 48VDC.
Power consumption: Power consumption: 181.6W Max. (Full load with
PoE), 15W Max. (Without PoE).
-40°C to 75°C (-40°F to 167°F) operating temperature range. Tested
for functional operation @ -40°C to 85°C (-40°F to 185°F).
For use in Pollution Degree 2 Environment.
Hardened metal case.
Supports Din-Rail or Panel Mounting installation.
<Note>
4-Port IEEE802.3at Power over Ethernet (PoE) Power Sourcing
Equipment (PSE) and 4-Port IEEE802.3af Power over Ethernet (PoE)
Power Sourcing Equipment (PSE) model: Port 1 ~ Port 4 supports 30W
IEEE802.3at Power over Ethernet (PoE) Power Sourcing Equipment

Hardened Managed PoE Ethernet Switch
User’sManual 13
(PSE) and Port 5 ~ Port 8 supports 15.4W IEEE802.3af Power over
Ethernet (PoE) Power Sourcing Equipment (PSE). This product model
can suppot output power budget up to total 181.6W.
Management Support
VLAN
Port-based VLAN
IEEE802.1Q tagged VLAN
TRUNKING
Port
Trunking
PORT-SECURITY
Per-port programmable MAC address locking
Up to 24 Static Secure MAC addresses per port
IEEE802.1x Port-based Network Access Control
PORT-MIRRORING
Port-mirroring
QOS (IEEE802.1p Quality of Service)
4 priority queues
INTERNETWORKING PROTOCOLS
Bridging:
IEEE802.1s Multiple Spanning Tree
IEEE802.1w Rapid Spanning Tree
IEEE802.1D Spanning Tree compatible
IEEE802.1Q – GVRP
Ring
IP Multicast:
IGMP Snooping
Rate Control
NTP
NETWORK MANAGEMENT METHODS
Console port access via RS-232 cable (CLI, Command Line Interface)
Telnet remote access
SNMP agent:
MIB-2 (RFC1213)
Bridge MIB (RFC1493)
RMON MIB (RFC2819) – statistics, history, alarm and events
VLAN MIB (IEEE802.1Q/RFC2674)
Private MIB
Web browser
TFTP software-upgrade capability

Hardened Managed PoE Ethernet Switch
Front Panel Display
POWER
This LED comes on when the switch is properly connected to power and
turned on.
Port Status LEDs
The LEDs are located on the front panel, displaying status for each
respective port. Please refer to the following table for more details.
LED State Indication
10/100Base-TX
Steady A valid network connection established.
LINK/ACT Flashing Transmitting or receiving data.
ACT stands for ACTIVITY.
Steady Power Device (PD) is connected.
PoE Off Power Device (PD) is disconnected.
User’sManual 14

Hardened Managed PoE Ethernet Switch
User’sManual 15
1000Base SFP
Steady A valid network connection established.
LINK/ACT Flashing Transmitting or receiving data.
ACT stands for ACTIVITY.
Physical Ports
The Hardened Managed Ethernet Switch provides:
Number of ports
10/100Base-TX (802.3at) 4
10/100Base-TX (802.3af) 4
1000Base SFP 2
CONNECTIVITY
RJ-45 connectors on TX ports
Single or Duplex LC connectors on SFP
1000Base-SX/LX/BX fiber transceiver
MODE SELECTION
10Base-T full-duplex mode
10Base-T half-duplex mode
100Base-TX full-duplex mode
100Base-TX half-duplex mode
1000Base-SX/LX full-duplex mode
Auto-negotiating mode

Hardened Managed PoE Ethernet Switch
User’sManual 16
Switch Management
Web-based browser interface
The switch also boasts a point-and-click browser-based interface that
lets user access full switch configuration and functionality from a
Netscape or Internet Explorer browser.
Administration console via RS-232 serial port (CLI)
The switch provides an onboard serial port, which allows the switch to be
configured via a directly connected terminal.
External SNMP-based network management
application
The switch can also be configured via SNMP.

Hardened Managed PoE Ethernet Switch
User’sManual 17
Installation
This chapter gives step-by-step instructions about how to
install the switch:
Selecting a Site for the Switch
As with any electric device, you should place the switch
where it will not be subjected to extreme temperatures,
humidity, or electromagnetic interference. Specifically, the
site you select should meet the following requirements:
-The ambient temperature should be between -40°C to 75°C (-40°F to
167°F).
-The relative humidity should be less than 95 percent, non-condensing.
-Surrounding electrical devices should not exceed the electromagnetic field
(RFC) standards.
-Make sure that the switch receives adequate ventilation. Do not block the
ventilation holes on each side of the switch.
Wiring Diagram
Field Wiring Terminal Markings: Use Copper Conductors Only,
60/75°C, wire range 12-24 AWG, torque value 7 lb-in.

Hardened Managed PoE Ethernet Switch
DIN Rail Mounting
Fix the DIN rail attachment plate to the back panel of the
Media Converter.
Installation: Place the Media Converter on the DIN rail from
above using the slot. Push the front of the Media Converter
toward the mounting surface until it audibly snaps into place.
Removal: Pull out the lower edge and then remove the Media
Converter from the DIN rail.
User’sManual 18

Hardened Managed PoE Ethernet Switch
Connecting to Power
Redundant DC Terminal Block Power Inputs or DC Jack
Power Input:
47-57VDC Jack
Step 1: Connect the supplied AC to DC power adapter to the receptacle on
the topside of the switch.
Step 2: Connect the power cord to the AC to DC power adapter and attach
the plug into a standard AC outlet with the appropriate AC voltage.
Redundant 47-57VDC DC Terminal Block Power
Inputs
There are two pairs of power inputs for use with redundant
power sources. You only need to have one power input
connected to run the switch.
Step 1: Connect the DC power cord to the plug-able terminal block on the
switch, and then plug it into a standard DC outlet.
User’sManual 19

Hardened Managed PoE Ethernet Switch
Step 2: Disconnect the power cord if you want to shut down the switch.
Back View
Alarms for Power Failure
Step 1: There are two pins on the terminal block used for power failure
detection. It provides the normally closed output when the power
source is active. Use this as a dry contact application to send a
signal for power failure detection.
Power Input Assignment
Power3 47-57VDC DC Jack
+47-57VDC
Power2 -Power Ground
+47-57VDC
Power1 -Power Ground
Earth Ground
Terminal
Block
Relay Output Rating 1A @ 250VAC
Relay Alarm Assignment
FAULT
*Warning signal disable for following:
The relay contact closes if Power1 and
Power2 are both failed but Power3 on.
The relay contact closes if Power3 is failed
but Power1 and Power2 are both on.
Special note:
The relay output is normal open position when there is no power to the
switch. Please do not connect any power source to this terminal to
prevent shorting your power supply.
User’sManual 20
Table of contents
Other Siqura Network Router manuals
Popular Network Router manuals by other brands

NETGEAR
NETGEAR orbi CBK40 quick start guide

Draytek
Draytek Vigor3912 Series quick start guide

Hewlett Packard Enterprise
Hewlett Packard Enterprise Aruba 6300F Product End-of-Life Disassembly Instructions

Teltonika
Teltonika QSG RUT955 manual

GL-INET
GL-INET GL-MiFi Technical specification

Billion
Billion BiPAC 5200N Specifications

SMC Networks
SMC Networks FS5 - annexe 1 Quick installation guide

Martin Jerry
Martin Jerry IN-2G user manual

SMC Networks
SMC Networks EZ1026DT user guide

APM
APM AQ-500h Specification sheet

Cisco
Cisco 2821 - Integrated Services Router Unified Communications... overview

NetComm
NetComm NTC-140-02 quick start guide