Sirius Satellite Radio SEM1 Operating and maintenance instructions

1
This installation should only be performed by a qualified tradesperson. Where possible, use a trained Sirius recommended
installer (see Siriusbrand.com). Sirius will not be held responsible for issues that occur due to installation of product by an
unqualified tradesperson.
• Motor must be accessible for servicing purposes. If not, servicing may be refused unless access can be provided.
• The ducting of the rangehood must not be connected to ducting which is used for exhausting other fumes from
appliances, such as central heating, boilers etc.
• For the external exhausting of the fumes, comply with the Australian building standards.
• Ventilate the room suitably according to the Australian building standards when the appliance is working together with
gas or oil appliances.
• The SEM motor is powered by the rangehood. Standard 10AMP GPO at the point of rangehood required.
• Before connecting the rangehood to the mains supply, make sure that the voltage indicated in the rating plate
corresponds to the mains voltage in the home.
• Before carrying out any sort of maintenance or cleaning operation, make sure that the appliance is disconnected from
the electrical mains.
IMPORTANT INFORMATION BEFORE INSTALLATION IN YOUR SIRIUS RANGEHOOD
• Only use ducting that falls within the necessary minimum and maximum length requirements as specified in the
installation guide.
• Try and minimise bends to the ducting for optimum performance.
• Use only suitable ducting as specified by Sirius. Under no circumstances is flexible ducting to be used as it creates
unwanted noise, vibration and can place the motor under unnecessary stress resulting in premature failure of the SEM
motor.
• Under no circumstances is the duct diameter is the duct diameter to be reduced. A constant minimum diameter of
150mm for the SEM 1 / 2 / 5 must be maintained at all times. For SEM 7 / 8 motors a constant diameter of 200mm
must be maintained at all times.
• Read the mounting and operating instructions of the rangehood carefully.
• The manufacturer cannot be held responsible for a decrease of the airflow or for an increase of noise level caused by
non-compliance with the instructions above.
BEFORE YOU INSTALL
WARNING
Installation guide for
SEM motors 1, 2, 7, 8

2
For ease of installation the SEM 1 motor can be fixed
inside the roof cavity or positioned underneath the floor of
the house, providing the SEM motor is protected from the
elements. The SEM motor uses mounting brackets to fix it
securely to the predetermined location. This location must
be accessible.
Motor/ducting and electrical connection installation
1. After deciding the location of the motor (no closer
than 2 metres and no further than 7 metres from the
rangehood). The motor should ideally be located
closer to the venting point for maximum air movement.
Insert the supplied rubber anti-vibration caps into
holes on the supplied brackets. The rubber caps must
be inserted on the side of the bracket that fixes to the
structure. These caps will reduce any vibration and
reduce the noise level of the motor.
(Fig 1. [1C])
2. Using the supplied screws connect the brackets (Fig.
1A) to the motor (Fig. 1B)
3. Align the SEM motor brackets with predetermined
location and mark the points required for pre-drilling of
the holes.
4. After pre-drilling the holes, insert the plastic dowels
(Fig. 2A) and then fix in place using the supplied
screws (Fig. 2B).
Make sure you have taken note of the inwards and
outwards arrows on the SEM motor and the motor is
positioned accordingly.
5. Connect a length of Sirius 150mm ducting to the collar
of the rangehood and secure with a URC25/215 ring
clamp (if using semi-rigid ducting).
6. Run the length of ducting to the location of the SEM
motor and secure to the inlet collar and secure with
another URC25/215 ring clamp (if using semi-rigid
ducting).
7. Run another length of 150mm ducting from the outlet
collar on the SEM motor to the predetermined exit
point/vent.
See Sirius website for wall, roof, and eave venting
options or contact your nearest Sirius retail partner.
8. The SEM motor has a 7 metre long cable with a 6
pin connection and an earth wire. Run the cable
from the location of the rangehood and connect the
6 pin connection, then connect the earth wire to the
rangehood by removing a screw from the rangehood
housing and then fixing it in place by reattaching the
screw.
9. The motor will draw power itself from the rangehood
which is plugged into a 10AMP powerpoint located
within 1 metre of the rangehood.
SEM1 MOTOR
(Fig.1)
Roof venting option shown
(Fig. 2)
1A
2A
2A
2B
2B
2A
1B
1C
165mm
150mm
150mm
150mm
300mm
Air direction
Power cord
250mm
300mm
200mm
100mm
50mm
150mm
90mm
125mm
125mm

3
SEM1 MOTOR WIRING DIAGRAM

4
The SEM2 motor is designed to exhaust fumes and
odours silently and effectively. It must be installed on an
external wall a minimum of 500mm from the ground and
connected to the rangehood.
• Note: due to OHS regulations if the SEM2 motor is
positioned higher than 2 metres from the ground,
additional servicing costs may incur. Please note:
motor must be accessible.
Note: Due to the noise of the motor itself once installed, be
sure to check that if it located close to a boundary fence
or you are in a built-up area that you have checked with
neighbours or local council regulations prior to installation.
Motor location
1. Please note that the SEM2 motor must be installed at
a minimum distance of 2 metres from the outlet collar
on the rangehood. A maximum of 7 metres must not
- under any circumstances - be exceeded. All SEM2
motors come fitted with a 7 metre long control cable.
Installation
1. The installation of the SEM2 motor must only be made
by a qualified technician/tradesperson. Where possible
use a Sirius recommended installer (See www.
siriusbrand.com for a list under the support tab)
2. After predetermining the location of the motor, make
sure you are within the recommendations above in
regards to min/max distances. Use the supplied drill
hole template that is supplied with SEM2 motor and
drill support holes, paying careful attention to make
sure that the area behind is clear of electrical cables
and piping/plumbing. These holes are to be drilled with
an 8mm drill bit.
3. 160mm diameter hole to be cut into house for 150mm
ducting. Please note that if a solid masonary block wall
or brick wall is being used that a series of holes may
need to be drilled and then the remainder of the hole
be knocked out by hand with a hammer and chisel.
If a masonary hole bit is available, this will provide the
best result.
4. A hole must also be made to contain the plastic pipe
that the SEM2 wiring loom is fed through. 40mm hole
is required (Fig. 3). 40mm drill but required.
5. Remove the stainless steel body to expose the motor
and fixing points by removing the external screws
located on the outside of the SEM2 motor (Fig.4).
6. Run the length of semi-rigid/solid duct through the
pre-cut hole and attach to the SEM2 collar. Secure in
place with a URC-25/215 ring clamp, making sure it is
fastened tightly and will not come off. Feed the cable
from the motor through the 40mm plastic pipe at the
same time.
7. Lining up the fastening points with the pre-drilled
holes, secure the motor in place using the supplied
plastic dowels and the supplied screws.
8. Replace the stainless steel body by following the
step 5 in reverse, making sure that the holes line up
perfectly to ensure the unit is sealed correctly. Do not
silicone motor to the wall.
9. Run the length of ducting back to the location of
the rangehood and secure to the outlet collar on the
rangehood using another URC25-215 ring clamp.
10. Run the cable from the motor to the rangehood and
plug in the 6 pin plug to the top of the unit. There is
a 2 pin plug that is the speed control that needs to
be plugged in as well. Remove the red dummy plug
and connect the 2 pin plug. The motor must then
be earthed to the body of the rangehood using the
green and yellow cable by unscrewing one of the body
screws, connecting the earth wire to the rangehood by
tightening the screw back up.
11. The SEM2 motor will draw power directly from the
rangehood which needs to be plugged into a 10AMP
powerpoint located within 1 metre of the rangehood.
SEM2 MOTOR
AA
A
A
B
Screws
B
B
B
B
160mm
40mm
A
(Fig. 3)
(Fig. 4)
148mm
220mm
230mm
238mm
212mm
450mm
450mm

5
Lasciare volante
connettore 2 poli maschio
SEM2 MOTOR WIRING DIAGRAM

6
The SEM7 motor is designed to exhaust fumes and
odours silently and effectively. It must be installed on an
external wall a minimum of 500mm from the ground and
connected to the rangehood.
Note: due to OHS regulations if the SEM7 motor is
positioned higher than 2 metres from the ground,
additional servicing costs may incur. Please note, motor
must be accessible for servicing.
Note: due to the noise of the motor itself once installed, be
sure to check that if it is located close to a boundary fence
or you are in a built up area that you have checked with
neighbours or local council regulations prior to installation.
Motor/ducting and electrical connection installation
• Please note that the SEM7 motor must be installed at
a minimum distance of 2 metres from the outlet collar
on the rangehood. A maximum of 7 metres must not
under any circumstances be exceeded. All SEM7
motors come fitted with a 7metre long control cable.
1. The installation of the SEM7 motor must only be made
by a qualified technicial/tradesperson. Where possible
use a Sirius recommended installer. (See www.
siriusbrand.com for a list under the support tab)
2. After predetermining the location of the motor, make
sure you are within the recommendations above in
regards to min/max distances. Use the supplied drill
hole template that is supplied with the SEM7 motor
and drill support holes, paying careful attention to
make sure that the area behind is clear of electrical
cables and/or piping & plumbing. These holes are to
be drilled with an 8mm drill bit.
3. 210mm diameter hole to be cut into house for 200mm
ducting. Please note that if a solid masonary block wall
or brick wall is being used thaty a series of holes may
need to be drilled and then the remainder of the hole
be knock out by hand with a hammer and chisel. If a
masonary hole bit is available, this will provise the best
result.
4. A hole must also be made to contain the plastic pipe
that the SEM7 wiring loom is fed through. 40mm hole
is required. 40mm drill bit required.
5. Remove the stainless steel body to expose the motor
and fixing points by removing the external screws
located on the outside of the SEM7 motor. (Fig.4)
6. Run the length of semi-rigid/solid duct through the
pre-cut and attach to the SEM7 collar. Secure in
place with a URC-25/215 ring clamp, making sure it is
fastened tightly and will not come off. Feed the cable
from the motor though the 40mm plastic pipe at the
same time.
7. Lining up the fastening points with the pre-drilled holes
secure the motor in place using the supplied plastic
dowels and the supplied screws.
8. Replace the stainless steel body by following the
step 5 in reverse making sure that the holes line up
perfectly to ensure the unit is sealed correctly. Do not
silicone motor to the wall.
9. Run the length of ducting back to the location of
the rangehood and secure to the outlet collar on the
rangehood using anouther URC25-215 ring clamp.
10. Run the cable from the motor to the rangehood and
plug in the 6 pin plug to the top of the unit. There is a
2 pin plug that is the speed control that needs to be
plugged in also, removal of the red capped dummy
plug will expose the location. The motor must then
be earthed to the body of the rangehood using the
green andyellow cable by unscrewing on of the body
screw, connecting the earth wire to the rangehood by
tightening the screw back up.
11. The SEM7 motor will draw power directly from the
rangehood which needs to be plugged into a 10AMP
powerpoint located within 1 metre of the rangehood.
SEM7 MOTOR
AA
A
A
B
Screws
B
B
B
B
210mm
40mm
A
(Fig. 3)
(Fig. 4)

7
SEM7 MOTOR WIRING DIAGRAM

8
For ease of installation the SEM8 motor can be fixed inside
the roof cavity or positioned underneath the floor of the
house, providing the SEM8 motor is protected from the
elements. The SEM8 motors uses mounting brackets to
fix it securely to the predetermined location. This location
must be accessible.
Motor/ducting and electrical connection installation
1. After deciding the location of the SEM8 motor (no
close than 2 metres and no further than 7 metres
from the rangehood) insert the supplied rubber anti-
vibration caps into the holes on the supplied brackets.
The motor should be ideally located closer to the
venting point for maximum air movement. The rubber
caps must be inserted on the side of the bracket that
fixes to the structure. These caps will reduce any
vibration and reduce the noise level of the motor.
(Fig1. [1C])
2. Using the supplied screws connect the brackets (Fig.
1A) to the motor (Fig. 1B).
3. Align the SEM8 motor bracket with predetermined
location and mark the points required for pre-drilling of
the holes.
4. After pre-drilling he holes, insert the plastic dowels
(Fig. 2A) and then fix in place using the supplied
screws (Fig. 2B).
Make sure you have taken note of the inwards and
outwards arrows on the SEM8 motor and the motor is
positioned accordingly.
5. Connect a length of Sirius 200mm ducting to the collar
to the rangehood and secure with a URC25/215 ring
clamp (if using semi-rigid ducting).
6. Run a length a ducting to the location of the SEM8
motor and secure to the inlet collar and secure with
another URC25/215 ring clamp (if using semi-rigid
ducting).
7. Run another length of 200mm ducting from the outlet
collar on the SEM8 motor to the predetermined exit
point/vent. See Sirius website for wall/room and eave
venting options or contact your nearest Sirius retail
partner.
8. Run the cable from the motor to the rangehood and
plug in the 6 pin plug to the top of the unit. There
is a 2 pin plug that is the speed control that needs
to be plugged in as well. Remove the red dummy
plug to expose the location. The motor must then be
earthed to the body of the rangehood using the green
and yellow cable by unscrewing onme of the body
screws, connecting the earth wire to the rangehood by
tightening the screw back up.
9. The motor will draw power itself from the rangehood
which is plugged into a 10AMP powerpoint located
within 1 metre of the rangehood.
SEM8 MOTOR
(Fig.1)
Roof venting option shown
(Fig. 2)
1A
2A
2A
2B
2B
2A
1B
1C
150mm
205mm
205mm
205mm
415mm
Air direction
Power cord
270mm
350mm
200mm
100mm
50mm
205mm
120mm
135mm
135mm

9
Do not connect
2 poles male connector
SEM8 MOTOR WIRING DIAGRAM
Other manuals for SEM1
1
This manual suits for next models
3
Table of contents
Other Sirius Satellite Radio Engine manuals