Sirus I-Amp 4.500T User manual

I-Amp 4.500T,
I-Amp 8.150T
Power Amplier
User Manual

Musikhaus Thomann
Thomann GmbH
Hans-Thomann-Straße 1
96138 Burgebrach
Germany
Telephone: +49 (0) 9546 9223-0
E-mail: [email protected]
Internet: www.thomann.de
27.02.2023, ID: 551986, 551991

Table of contents
1 General information................................................................................................................................. 4
1.1 Further information........................................................................................................................... 5
1.2 Notational conventions.................................................................................................................... 5
1.3 Symbols and signal words............................................................................................................... 6
2 Safety instructions..................................................................................................................................... 8
3 Features....................................................................................................................................................... 13
4 Installation and starting up................................................................................................................ 14
5 Connections and controls................................................................................................................... 18
6 Technical specications....................................................................................................................... 25
7 Plug and pin assignments................................................................................................................... 28
8 Cleaning....................................................................................................................................................... 29
9 Protecting the environment.............................................................................................................. 30
Table of contents
I-Amp 4.500T, I-Amp 8.150T 3
Power Amplier

1 General information
This user manual contains important information on the safe operation of the device. Read and
follow all safety notes and all instructions. Save this manual for future reference. Make sure
that it is available to all persons using this device. If you sell the device to another user, be sure
that they also receive this manual.
Our products and user manuals are subject to a process of continuous development. We there‐
fore reserve the right to make changes without notice. Please refer to the latest version of the
user manual which is ready for download under www.thomann.de.
General information
4I-Amp 4.500T, I-Amp 8.150T
Power Amplier

1.1 Further information
On our website (www.thomann.de) you will nd lots of further information and details on the
following points:
Download This manual is also available as PDF le for you to download.
Keyword search Use the search function in the electronic version to nd the topics of
interest for you quickly.
Online guides Our online guides provide detailed information on technical basics
and terms.
Personal consultation For personal consultation please contact our technical hotline.
Service If you have any problems with the device the customer service will
gladly assist you.
1.2 Notational conventions
This manual uses the following notational conventions:
General information
I-Amp 4.500T, I-Amp 8.150T 5
Power Amplier

The letterings for connectors and controls are marked by square brackets and italics.
Examples: [VOLUME] control, [Mono] button.
1.3 Symbols and signal words
In this section you will nd an overview of the meaning of symbols and signal words that are
used in this manual.
Signal word Meaning
DANGER! This combination of symbol and signal word indicates an
immediate dangerous situation that will result in death or
serious injury if it is not avoided.
CAUTION! This combination of symbol and signal word indicates a pos‐
sible dangerous situation that can result in minor injury if it
is not avoided.
NOTICE! This combination of symbol and signal word indicates a pos‐
sible dangerous situation that can result in material and
environmental damage if it is not avoided.
Letterings
General information
6I-Amp 4.500T, I-Amp 8.150T
Power Amplier

Warning signs Type of danger
Warning – high-voltage.
Warning – danger zone.
General information
I-Amp 4.500T, I-Amp 8.150T 7
Power Amplier

2 Safety instructions
This unit amplies audio frequency signals for the operation of passive loudspeakers. It is
designed for professional use only. Use the device only as described in this user manual. Any
other use or use under other operating conditions is considered to be improper and may result
in personal injury or property damage. No liability will be assumed for damages resulting from
improper use.
This device may be used only by persons with sucient physical, sensorial, and intellectual
abilities and having corresponding knowledge and experience. Other persons may use this
device only if they are supervised or instructed by a person who is responsible for their safety.
DANGER!
Danger for children
Ensure that plastic bags, packaging, etc. are disposed of properly and are not
within reach of babies and young children. Choking hazard!
Ensure that children do not detach any small parts (e.g. knobs or the like) from
the unit. They could swallow the pieces and choke!
Never let children unattended use electrical devices.
Intended use
Safety
Safety instructions
8I-Amp 4.500T, I-Amp 8.150T
Power Amplier

DANGER!
Electric shock caused by high voltages inside
Within the device there are areas where high voltages may be present. Never
remove any covers.
There are no user-serviceable parts inside.
Do not use the device if covers, protectors or optical components are missing or
damaged.
DANGER!
Hazardous voltage
Hazardous voltage may be present at cable ends and screw terminals.
The connection of screw terminals as well as all maintenance and repair work on
the electrical installation of the device must only be performed by qualied elec‐
trical personnel in volt-free condition. Failure to do so may result in electric shock
and risk of re and loss of life.
By all means you have to observe all electrical safety instructions applicable at the
place of operation.
Safety instructions
I-Amp 4.500T, I-Amp 8.150T 9
Power Amplier

DANGER!
Electric shock caused by short-circuit
Always use proper ready-made insulated mains cabling (power cord) with a pro‐
tective contact plug. Do not modify the mains cable or the plug. Failure to do so
could result in electric shock/death or re. If in doubt, seek advice from a regis‐
tered electrician.
CAUTION!
Possible hearing damage
With loudspeakers or headphones connected, the device can produce volume
levels that may cause temporary or permanent hearing impairment.
Do not operate the device permanently at a high volume level. Decrease the
volume level immediately if you experience ringing in your ears or hearing
impairment.
NOTICE!
Risk of re
Do not block areas of ventilation. Do not install the device near any direct heat
source. Keep the device away from naked ames.
Safety instructions
10 I-Amp 4.500T, I-Amp 8.150T
Power Amplier

NOTICE!
Operating conditions
This device has been designed for indoor use only. To prevent damage, never
expose the device to any liquid or moisture. Avoid direct sunlight, heavy dirt, and
strong vibrations.
NOTICE!
Power supply
Before connecting the device, ensure that the input voltage (AC outlet) matches
the voltage rating of the device and that the AC outlet is protected by a residual
current circuit breaker. Failure to do so could result in damage to the device and
possibly injure the user.
Unplug the device before electrical storms occur and when it is unused for long
periods of time to reduce the risk of electric shock or re.
NOTICE!
Possible damage due to installation of a wrong fuse
The use of dierent types of fuses can cause serious damage to the unit. Fire
hazard!
Only fuses of the same type may be used.
Safety instructions
I-Amp 4.500T, I-Amp 8.150T 11
Power Amplier

NOTICE!
Magnetic elds
The device generates strong magnetic elds that can interfere with the function
of poorly shielded devices. The strongest magnetic elds are directly above and
below the power amplier. Therefore, never place sensitive devices such as pre-
ampliers, radio transmission systems, or tape decks directly above or below the
power amplier. When installing the power amplier into a rack, you should place
it in the lowest position, and further equipment such as pre-ampliers in the
highest position.
Safety instructions
12 I-Amp 4.500T, I-Amp 8.150T
Power Amplier

3 Features
n4-channel installation amp, 4×480 watts @ 70/100 V (RMS), Class-D amplier
nLow-noise and low-distortion due to high-current switching capacity
nProtection circuits such as thermal, short circuit, on/o muting
nLimiter, Euroblock input and output, gain on the front for easy access
nSignal, clip, protect and power LED, Euroblock contacts for deactivation, priority and error
status
nFrequency response 100 Hz–15 kHz, input impedance 20 k ohm balanced / 10 k ohm
unbalanced
nDimensions: (W × D × H) 483 × 360 × 44 mm, 19-inch rack size (1 RU)
nWeight: 6.3 kg
n8-channel installation amp, 8×150 watts @ 70/100 V (RMS), Class-D amplier
nIdeal for installations such as multi-zone applications
nProtection circuits such as thermal, short circuit, on/o muting
nEuroblock input and output, volume control and mains switch installed on the back
nSignal, clip, protect and power LED
nFrequency response 100 Hz–15 kHz, input impedance 20 k ohm balanced / 10 k ohm
unbalanced
nDimensions: (W × D × H) 483 × 360 × 44 mm, 19-inch rack size (1 RU)
nWeight: 7 kg
Sirus I-Amp 4.500T
Sirus I-Amp 8.150T
Features
I-Amp 4.500T, I-Amp 8.150T 13
Power Amplier

4 Installation and starting up
Unpack and check carefully there is no transportation damage before using the unit. Keep the
equipment packaging. To fully protect the product against vibration, dust and moisture during
transportation or storage use the original packaging or your own packaging material suitable
for transport or storage, respectively.
Create all connections while the device is o. Use the shortest possible high-quality cables for
all connections. Take care when running the cables to prevent tripping hazards.
DANGER!
Hazardous voltage
Hazardous voltage may be present at cable ends and screw terminals.
The connection of screw terminals as well as all maintenance and repair work on
the electrical installation of the device must only be performed by qualied elec‐
trical personnel in volt-free condition. Failure to do so may result in electric shock
and risk of re and loss of life.
By all means you have to observe all electrical safety instructions applicable at the
place of operation.
Installation and starting up
14 I-Amp 4.500T, I-Amp 8.150T
Power Amplier

DANGER!
Electric shock caused by high voltages at the power amplier output
The output voltages of modern high-performance ampliers may result in death
or serious injury.
Never touch the bare ends of loudspeaker cables when the amplier is on.
NOTICE!
Magnetic elds
The device generates strong magnetic elds that can interfere with the function
of poorly shielded devices. The strongest magnetic elds are directly above and
below the power amplier. Therefore, never place sensitive devices such as pre-
ampliers, radio transmission systems, or tape decks directly above or below the
power amplier. When installing the power amplier into a rack, you should place
it in the lowest position, and further equipment such as pre-ampliers in the
highest position.
The unit has been designed for rack mounting in a standard 19-inch rack; it occupies one rack
unit.
The input signals are connected to the Euroblock terminals. The supplied sockets are used for
this purpose.
Rack mounting
Input signals
Installation and starting up
I-Amp 4.500T, I-Amp 8.150T 15
Power Amplier

Sirus I-Amp 4.500T
nUp to four input signals can be connected to the device (channel terminals [CHA]–[CHD]).
Sirus I-Amp 8.150T
nUp to eight input signals can be connected to the device (channel terminals [INPUT1]–
[INPUT8]).
nTo connect unbalanced input signals, use the [+] and [G] terminals of the respective
channel on the Euroblock.
nTo connect balanced input signals, use the [+], [-] and [G] terminals of the respective
channel on the Euroblock.
The respective input signals can be assigned to dierent zones, or one input signal can be
assigned to all zones.
The device is equipped with two Euroblock terminals that can be used to connect the ELA
speakers (70-V technology or 100-V technology). You need to set the relevant operating mode
(70 V or 100 V) for each individual channel via DIP switches.
Observe the following diagram when connecting the loudspeakers. The total power consump‐
tion of the connected speakers must be below the maximum power of the amplier. We rec‐
ommend a power reserve of 20%.
Sirus I-Amp 4.500T
nIn the device, up to four input signals can be assigned to four dierent speaker zones, or
one single input signal can be assigned to all four speaker zones.
Speaker connection
Installation and starting up
16 I-Amp 4.500T, I-Amp 8.150T
Power Amplier

Sirus I-Amp 8.150T
nUp to eight input signals can be assigned to eight dierent speaker zones on the device.
In the example, three 100-V speakers connected in parallel are connected to two speaker con‐
nections that form two speaker zones.
Installation and starting up
I-Amp 4.500T, I-Amp 8.150T 17
Power Amplier

5 Connections and controls
$
# &
'
% (
1 Mains switch. Turns the device on and o.
2[SIG] | Indicates the presence of an input signal. The higher the signal level, the faster the LED ashes.
3[CLIP] | Lights up when the channel is overdriven. In this case, reduce the signal level with the channel control until the
LED goes out.
4[PRO] | Lights up when one or more protective circuits have tripped or the device is defective. No sound is output. Make
sure that the vents of the device are free and that good ventilation is possible. Reduce the volume on the device. If the
problem is resolved, the protection circuits are automatically reset and the device is ready for use again.
5 Channel control for input signal gain.
Front of the Sirus I-Amp 4.500T
Connections and controls
18 I-Amp 4.500T, I-Amp 8.150T
Power Amplier

6 Channel LED lights up green when the device is turned on. Channel LED lights up red when test signal priority is enabled
via the [PRI] Euroblock terminal.
7[BRI] | Lights up when the unit is operating in bridged mode.
Connections and controls
I-Amp 4.500T, I-Amp 8.150T 19
Power Amplier

,
) +*
8[CHA]–[CHD] | Signal inputs, designed as Euroblock terminals
[+] | Balanced or unbalanced signal input (+)
[G] | Ground (GND)
[-] | Balanced signal input (-); remains free in case of unbalanced input signals
[FAIL] | Error status output: +5 V in normal operation; 0 V when a protection circuit trips
[DIS] | Control input for switching o the device; Switching to ground (GND) switches the amplier stage o.
[PRI] | Control input for switching the test signal priority; Switching to ground (GND) enables the test signal on the
[Test] signal output. Channel LEDs light up red.
Back of the Sirus I-Amp 4.500T
Connections and controls
20 I-Amp 4.500T, I-Amp 8.150T
Power Amplier
This manual suits for next models
1
Table of contents
Other Sirus Amplifier manuals