8½" x 1¼" x 9¼" (217 x 33 x 235mm)
Flange dimensionsFlange code
MINI LOOK S7206, S7211, S7215, S7220, SL9206, SL9211 S7249
8½" x 1¾" x 9¼" (290 x 43 x 231mm)
S7269
MINI COOL S7236, S7241, SL9236, SL9241
LOOK S7260, S7261, S7262, S7265, S7266, S7267
COOL S7245, S7246
3¾" x 1¾" x 6⅝" (96 x 45 x 167mm)
S7284
MICRO COOL SQUARE S7287
5⅝" x 3⅝" x 9⅞ (149 x 66 x 251mm)
S7288
MINI COOL SQUARE S7286
8½" x 3⅜" x 9⅞ (217 x 85 x 250mm)
S7289
COOL SQUARE S7285
Model Model Code
LOOK / COOL
BOLLARD
INSTRUCTIONS SHEET PAGE: 1 of 3
INS-532
9320 Boul. St-Laurent, suite 100, Montréal (Québec) Canada H2N 1N7
P.: 514.523.1339 F.: 514.525.6107 www.sistemalux.com
DM - R4Last update: Avril 11, 2022
IMPORTANT - READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES, BY A PERSON FAMILIAR WITH THE
CONSTRUCTION AND OPERATION OF THE PRODUCT, AND THE HAZARDS INVOLVED. PROPER GROUNDING IS REQUIRED FOR SAFETY.
GROUND INSTALLATION IN CONCRETE WITH FLANGE.
INTEGRAL DRIVER 120-277V (UNV)
A
A- DIG A HOLE (SEE DIMENSION BELOW), PUT THE FLANGE AND ELECTRICAL CONDUIT INTO THE GROUND. POUR CONCRETE AND MAKE
SURE IT IS LEVELED WITH THE FLANGE.
*MINIMUM OF 12" OF GRAVEL IS REQUIRED BELOW THE LUMINAIRE TO ALLOW PROPER DRAINAGE).
OK
90°
NO!
NO!
CONCRETE
MIN
12"
(305mm)
FLANGE
GRAVEL
ELECTRICAL CONDUIT