Siter GS901 User manual

Wireless pepper spraysystem
GS901
Installation Guide
Pleasereadthisguidecarefullyandkeepit ina safeplace

1
PRODUCTDESCRIPTION
1Productworking priciple
The systemusethePIRasthe firstsensor,usethe activeinfra-red
transmissionmodule.Asthesecondsensortocontrolthesurveillance
place.themaximuminductivedistanceofthefirstsensoris10meters,the
farthestinductivedistanceofthe second sensoris1meters.
2Product functionintroduction
The systemhasbeen designedtopreventtheunpermissivepersonlikethief,
scamp,rascal.enterintothe importanceplacelikehome,officeetc,oncethe
systeminthe surveillancemode,ifthe unpermissivepersonenterintothe first
sensorsurveillancearea,the systemwill automaticallyalarm,if theunpermissiv
-
epersonenterintothesecondsensorsurveillancearea,thesystemwill
automatical
-lyspraythe pepper.
3Pepperinthesystemintroduction
Ourpepperingredientused naturalstrongstimulated ingredientsuchaspurely
extractivepepperelements,mustardelementsetc,itisinnocuityand will not
hurtthe people sorgans,ifsprayed on the people sface,theywillimmediately
appearthesymptomlikecan topentheireyes,tear,cough,pressureon the
chestetc,thereby,theywill losetheaction.thissymptomwillcontinueto20
minutes.

2
PACKAGE CONTENTS
1Wireless pepper spraysystem 2remotecontroller
1ACadaptor1instructionmanual
43.5×25screws64×15 screws4swelled screws
Self-attachments:
doormagnet
ATTENTION
1AlthoughthecrustismadefromABSplastic,pleasetakecarewhilein
Carryingandinstalling,don tlettheunitfall downorkickdown.
2whileinstalling,please do itstrictlyaccordingtothismanualtoavoid
thepeppersprayout.incase ofthepeppersprayedontheface,please
keepcalm,close thesystemandpull outthepower.use theclearwaterto
cleanout,thencleanby2%sodawater,after20 minutes youwill recover.

3
PRODUCTINTRODUCTIONCHART
(Figure1)
(Figure 2)

4
INSTALLTION
Connections
Insert thepositivewireintothe batterypositivehead
Attention:beforeconnectedtothebattery,please putthe2remote
controllersinasafetyplacetoavoidtoopenthesystemwhilein
installing.
(Figure3)
Optional function beforeinstallation
(Figure 4)

5
1Chosingthe operationmodeofthesystem
1.1Mode description
The systemhave2operation mode,itismastermode and slavermode.in
mastermode undersurveillance,ifthe peopleenterintothe firstsensor
surveillanceplace,itwillautomaticallyalarm,ifthe peopleenterintothe
second sensorsurveillanceplace,itwillalsoautomaticallyspraythe pepper.
inslavermode undersurveillance,ifthepeopleenterintosurveillance
place,itwillonlysend the wireless signaltothe masterand willnotalarm,it
willnot spraythepepperalso.
1.2Mode switch
Onthe rearofthe top cover,ithad 4pcs ofcircuitryboard,one ofthelargest
circuitryboardisthemaincontrolboard(seefigure4),ifyouinsertthemode
switchToM,itismastermode,ifyou inserttoS,itisslavermode,the default
mode ismastermode.
2Remotecontroller study
2.1The 2remotecontrollerswiththe systemalreadystudied,youcan use
directly.If you think2remotecontrollersarenotenough,and wantbuymore
remotecontrollers,afteryou boughtit,youneedletthoseremotecontrollers
study.otherwise,you can tcontrolthe system(the remotecontrollersyoucan
buyfromourdistribution)
2.2Studyprocedure
2.21 Pleasefind the dialswitchonthe maincontrolcircuitryboard,ithad 2
dialcodeonthedialswitch,itisworkandstudycode,pleasedialwork
code to”1”,,dailstudycode to “N”,itindicatethe systemturnintothestudy
mode.meanwhile,youwillsee thestudylightwillbe yellow.
2.22 Press anybutton on the remotecontroller,it willbeep 2timesand you
willsee the studylightwillbe green,then the studylightwillgooutandturn
intoyellow,itindicatethestudyisfinished.ifitisalongbeep.whilein
studying,andthestudylightturnintored.then going outandturninto
yellow,itindicatethe studyisfailed ortheremotecontrolleralready
studied.Repeatagainthisproceduretilltofinishtheremotecontroller
whichneedstostudy.
2.23 Afteralltheremotecontrollersfinishtostudy.dailtheworkcode
to”O”,dailthe studymode to”2”,itindicatethe systemturnintothe operation
mode(the defaultmode isoperation mode),meantime,the studylightwillgo
out.pleasepress the”OFF”button onthe remotecontroller.the studylightwill
immediatelyflashgreen.Itindicatethe studycompletelysucceed.ifitflash
red,itindicatethe studyisfailed,pleasestudyagain.

6
Attention:Afterall theremotecontrollersfinishtostudy,pleaseputthe
remotecontrollersinasafetyplacetoavoidtoopenthesystemwhilein
installing.
Tips:Thesystemcanstudywithotherwireless equipmentslike door
magnet,etc.once thedoormagnetsend thewireless signaltothe
system,thesystemwill alarm.
3. Connectionswithother equipments
Onthe maincontrolcircuitryboard,ithad2port:JK_PORTand OP_PORT,it
used toconnectwithotherequipments.JK_PORTistherelayport,oncethe
systemalarm,the relaywillautomaticallyclose,itcan usetodriveotheralarm
systems,suchasdoorbell.the carryingcapacityofJKportis10A/250
VA,connection mode:1-2isclose,2-3isopen.OP-PORTisthe optical
port,oncethesystemalarm,the opticalportwillopen,itcanuseasdriver
signaltothe otheralarmsystems.the carrying capacityofOPportis
50MA/24V.
Tips:ifyoufeel theabovefunctionsdon tneedtouse.please don ttouch
themaincontrol circuitryboard,directtothenextstep!
System Fixation
1Foldthetop coverand the bottomcover,use64X20 screwstofasten.
2Drill46X40holeon the wall,theconcretepositionpleasesee Figure
5,afterfinished todrilltheholes,pleaseusethe hammerknock 4swell
screwsintothehole.
3Used the screwdriverand 43.5x25 screwstofixthe systemon the
wall,pleaseask thehelperif needed.
4Plug the ACadaptorintoDC socket.
(Figure5)

7
OPERATIONTEST
The operation onthe systemarethe sameno matterwhetherinmastermode
orslavermode.pleasetakecarewhen operation.
1Open the systemandpepperspraytest
Press the “ON”buttonontheremotecontroller,itwill beep2
times,meantime,the working lightwillflashred every4seconds.itindicatethe
systemisopen.the systemneed 30 secondstowarm-up afterthe systemis
open,withinthisperiod,ifthepeoplestand infrontofthe system,the system
willnotalarmand spraythe pepper,After30seconds,the working lightwent
out,the systemwill turnintothe surveillancemode.The firstsensorwill
continuouslydetect it ssurveillanceplacewhetherhavepeoplewithin10m,if
have,itwillautomaticallyalarm.meanwhile,open the second sensorto
detectorwhetherhavepeoplewithin1meters,ifhave,itwill automatically
spraythe pepper(see figure6). pleasetakecarewhen test.
(Figure6)
2Deactivatedalarmandclosethe system
Oncethesystemisinwarm-up,surveillancemode,alarmmode,Press
the”OFF”button.itwillbeep4times,the working lightwillturnintored,in
indicatethe systemisclosed and deactivated,ifwantopen the system,press
the”ON”button.
3Remotecontroltoalarm
Inanymode ofthe system,Press the”Alarm”button on the remote
controller,the systemwillalarmbutwill notspraythe pepper.thiswillremind
somebodytohelpyou.the systemcan be usewithin50metersbecausethe
Maximumdistanceofthe remotecontrollersare50M.

8
SYSTEMOPERATIONSTATUS DESCRIPTION
1Closestatus
The working light willlighton.
2Warm-up status
The workinglightflashevery4seconds,inthisstatus,thefirstsensorisjust
opened,itneed the timetowarm-up,butatthistime,the sytemcan receive
the wireless alarmsignalfromthe otherslaversystem,itwillalarmbutwill
notspraypepper.the wholeprocess ofwarm-up need about30 seconds,it
willautomaticallyturnintosurveillancemode.
3Surveillancemode
The firstsensorwillcontinuouslydetect it ssurveillanceplacewhetherhave
people,ifhave,itwill automaticallyalarm,the systemturnintoalarm
stutus,the worklightiswent outundersurveillancemode.
4Alarmstutas
Onceitalarms,the workinglightwillflashevery2seconds.meanwhile,open
the second sensortodetectorwhetherhavepeoplewithin1meters,ifhave,it
willautomaticallyspraythepepper.after5minutes,itwillautomaticallyturn
intosurveillancemode,then closethe second sensor.ofcourse,you can
press the”OFF”button onthe remotecontrollertodeactivate.
WORKINGLIGHT& CHARGEINDICATOR DESCRIPTION
1.The working lightalways lighton,it indicatethesystemisclosed.Flashling
every4seconds,indicateinwarm-up status.Flashing 2seconds,indicate
alarmstatus,always goingout,indicatesurveillancemode.
2.The chargeindicatorindicatethestatusofthe battery,ifitisgreen,it
indicatetocharge tothebattery.ifitiswent out,indicatethebatteryisfull.if
powercut,the batterycansupplythe powertothe systemmorethan 30
hours

9
IFLOSTTHEREMOTECONTROLLERS HOWCAN
WEDO?
If you lostthe remotecontroller,you canusethe memorytoeraseitscontrol
right.Butitwilleraseallthe othersremotecontrollers scontrol
right.therefore,aftererased,Alltheremotecontrollersneedstudyagain.we
suggestiflostone remotecontroller,pleaseerasethe memoryofall the
remotecontrollers,ofcourse,ifyouthinkitiscomplicated,youjustdon tdo
this,the otherremotecontrollersalsocan use.Pleasesee belowhowtoerase
the memory:
1Pulloutthe ACadaptor
2Usethescrewdrivertotakethe systemfromthe wall,openthecrust,please
takecareofthe screws.
3Findingout thedail switchonthemaincontrolcircuitryboard(seefigure4).
4Dailthe WORKcode to”O”,studycode to”N”,it willturnintothedeactivated
status,meanwhile,the studylight willbe yellow.
5Press anybutton onthe remotecontroller,itbeep 2timesand the study
lightwillbe green,itindicatetoerasethecontrolrightofthe remote
controller.repeat againtoerasethecontrolright of alltheremotecontrollers.
6Referto2.2tostudyallthe remotecontrollers.
7Foldthetop and bottomcover,fixthe systemon the wall.

10
TECHNIQUALSPECIFICATIONS
Model GS401
Theinductivedistanceofthefirst
sensor ≤10m
Theinductivedistanceofthesecond
sensor ≤1m
remotecontrolworkingdistance ≤50m
alert power ≤100 dB
Detection way Digitalinfra-red pluseand PIR
Operation temperature -30℃~60℃
Thespraydistanceofthepepper
canister ≥3m
Thesprayspeed ofthepepper
canister ≥8.5ml/s
Capacityofthepeppercanister ≥300ml
powersupply
alarm Battery(12V2Ah)+adaptor
remotecontrol 12V23A
Operationcurrent
Surveillance mode ≤10 mA
Alarmstatus ≤250 mA
Spraythepepper ≤2A
Table of contents