Installation and Operating Instructions
SJE VERTICALMASTER® PUMP SWITCH U.S. Patent No. 5,155,311 & Canadian Patent Pending.
SJE VERTICALMASTER®II PUMP SWITCH U.S. Patent No. 6,140,925 & Foreign Patents Pending.
SJE-RHOMBUS®FIVE-YEAR LIMITED WARRANTY
SJE-Rhombus®pump switches provide automatic control of pumps in
sump, efuent, and non-potable water applications.
SPECIFICATIONS
CABLE: Flexible 16 gauge, 2 conductor (UL, CSA) SJOW,
water-resistant (CPE)
MOUNTING BRACKET & HOSE CLAMP: Stainless steel
LIFT ROD: Acetal
LIFT ROD STOP PIN: Nylon
FLOAT STOP GROMMET: Neoprene
SWITCH AND FLOAT HOUSING: high impact, corrosion resistant, PVC
Switch and Float Overall: 30.5 cm high x 12.7 cm x 7.6 cm wide
Switch Housing: 5 cm high x 7.1 cm wide, has IPX7 protection
Float Housing: 6.4 cm high x 6.9 cm wide
ELECTRICAL:
120 VAC Rated Voltage:
Maximum Pump Running Current: 13 amps
Maximum Pump Starting Current: 60 amps
Frequency: 50/60 Hz
230 VAC Rated Voltage:
Maximum Pump Running Current: 13 amps
Maximum Pump Starting Current: 60 amps
Frequency: 50/60 Hz
Switch must be used with pumps that provide integral thermal
overload protection. Switch is not recommended for controlling
electric loads less than 2A, 12 VAC or non-arcing electric loads.
This equipment is suitable for Category II installations, rated to 52ºC, and protected by double insulation.
Approved for use in non-potable water.
CABLE:
Flexible 18 gauge, 2 conductor (UL, CSA) SJOW, water-resistant
(CPE)
MOUNTING BRACKET & HOSE CLAMP: Stainless steel
LIFT ROD: Acetal
LIFT ROD STOP PIN: Nylon
FLOAT STOP GROMMET: Neoprene
SWITCH AND FLOAT HOUSING: high impact, corrosion resistant,
PVC Switch and Float Overall: 30.5 cm high x 12.7 cm x 7.6 cm wide
Switch Housing: 5 cm high x 7.1 cm wide, has IPX7 protection
Float Housing: 6.4 cm high x 6.9 cm wide
ELECTRICAL:
125 VAC Rated Voltage:
Maximum Pump Running Current: 10 amps
Maximum Pump Starting Current: 60 amps
Frequency: 50/60 Hz
250 VAC Rated Voltage:
Maximum Pump Running Current: 10 amps
Maximum Pump Starting Current: 60 amps
Frequency: 50/60 Hz
Switch must be used with pumps that provide integral thermal
overload protection. Switch is not recommended for controlling
electric loads less than 100 miliamps, 12 VAC or non-arcing
electric loads.
SJE VERTICALMASTER® PUMP SWITCH SJE VERTICALMASTER®II PUMP SWITCH
Five-Year Limited Warranty.
For complete terms and condions, please visit www.sjerhombus.com.