PUB LS/P2 14145 EN · 1-3018-EN
Pulse Generator SP/SFE 30/3003
Technical data
General information
Type of enclosure . . . . . . . . . . . . . . II 2G c IIC T4 Gb
II 2D c IIIC T135°C Db
Mounting position . . . . . . . . . . . . . . any
Ambient temperature range . . . . . . . . . –20 to +40 °C
Lubricant temperature range . . . . . . . . –15 to +70 °C
Vibration resistance . . . . . . . . . . . . . 4 x g
Weight . . . . . . . . . . . . . . . . . . .1,1 kg
Hydraulic system
Operating pressure . . . . . . . . . . . . .4 to 600 bars
Control pressure loss. . . . . . . . . . . . . approx. 4 bars
Lubricant . . . . . . . . . . . . . . . . . . mineral, synthetic and
ecofriendly oils, grease
based on mineral oil
Service viscosity . . . . . . . . . . . . . . . > 12 mm²/s
Worked penetration . . . . . . . . . . . . . > 260 1/10 mm
Volumetric flow range . . . . . . . . . . . . 0,1 to 50 cm³/min
Volume/pulses. . . . . . . . . . . . . . . . 0,34 cm³ 1) 2)
Electrical system
Type of contact . . . . . . . . . . . . . . .reed contact
Voltalge Ui. . . . . . . . . . . . . . . . . . 30 V DC
Current Ii . . . . . . . . . . . . . . . . . .100 mA
Capacity Ci. . . . . . . . . . . . . . . . . . 1 nF
Inductivity Li. . . . . . . . . . . . . . . . . 5 µH
Connection
Type of connection. . . . . . . . . . . . . . plug, DIN 43 650-A
Plug. . . . . . . . . . . . . . . . . . . . . 3 +PE
1) One pulse comprises the opening or closing of the reed contact.
2) Volume/pulse = 0,68 cm³ when a pulse monitoring unit is used
(opening till reopening or closing to reclosing of reed contact).
Designation Order No.
SP/SFE 30/3003 pulse generator 24-2583-2526
Designation Order No.
Straight connector 406-411
G 1/4" for Ø 6 mm tubing
Straight connector 96-1108-0058
G 1/4" for Ø 8 mm tubing
!Note!
The customer must comply with the specific requirements
for the necessary cable section area (4 mm2) and the kind and
length of the grounding cable to be connected to the pulse
generator.
For the connection of the grounding cable, ATEX regulations
must be followed!
The switching of a pulse counter must be supplied by an
intrinsically safe circuit, e.g. through the installation of an ATEX-
compliant isolating switch by the customer. During maintenance
work, it is only permissible to use tools intended for use in explo-
sive areas, or a non-explosive atmosphere must be assured. The
user must make sure through their choice of the lubricant to be
delivered that no chemical reactions capable of serving as
ignition sources will occur in conjunction with the explosive
atmosphere expected.
CAUTION
For all systems described in this
brochure, see important product usage
information on the back cover.
Accessories
Order No.
Pulse generator SP/SFE 30/3003
3