SPECIFICATIONS
Model1: AVMP-4-B
Amplitude2: 1 - 10 Volts
Pulse width (FWHM): 10 ns - 10 us
Maximum PRF: 1 MHz
Maximum duty cycle: 10%
Rise time (20%-80%): ≤ 200 ps
Fall time (80%-20%): ≤ 200 ps
Required load impedance: 50 Ohms6
Polarity : Positive or negative or both (specify)
GPIB and RS-2 2 control1: Standard on -B units.
LabView Drivers: Check http://www.avtechpulse.com/labview for availability and downloads
Ethernet port, for remote control
using VXI-11. , ssh, telnet, & web:
Included. Recommended as a modern alternative to GPIB / RS-2 2.
See http://www.avtechpulse.com/options/vxi for details.
Settings resolution: The resolution of the timing parameters (pulse width, delay, period) varies,
but is always better than 0.15% of (|set value| + 20 ns).
The amplitude resolution is < 0.1% of the maximum amplitude.
Settings accuracy: Amplitude: Typically ± ( % of setting) ± (2% of maximum).
Delay, Period: Typically ± ( % of setting ) ± (5 ns)
Pulse width: Typically ± ( % of setting ) ± (2 ns), at maximum amplitude.
As the amplitude is reduced, the pulse width may shift ± 5 ns.
For high-accuracy applications requiring
traceable calibration, verify the output with a calibrated oscilloscope7.
Propagation delay: ≤ 200 ns (Ext trig in to pulse out)
Jitter: ± 5ps ± 0.015% of sync delay
Trigger modes: Internal trigger, external trigger (TTL level pulse, > 10 ns, 1 kΩ input impedance),
front-panel “Single Pulse” pushbutton, or single pulse trigger via computer command.
Variable delay: Sync out to main out: 0 to 1.0 seconds, for all trigger modes (including external
trigger).
Sync output: > + Volts, > 50 ns, will drive 50 Ohm loads
Monitor output option5: Provides a 20 dB attenuated coincident replica of main output
Connectors: Out, Monitor: SMA, Trig, Sync, Gate: BNC
Power requirements: 100 - 240 Volts, 50 - 60 Hz
Dimensions: (H x W x D) 100 mm × 4 0 mm × 75 mm ( .9” × 17” × 14.8”)
Chassis material: Aluminum frame & handles, blue vinyl on aluminum covers
Temperature range: +5°C to +40°C
1) -B suffix indicates IEEE-488.2 GPIB and RS-2 2 control of amplitude, pulse width, PRF and delay (See http://www.avtechpulse.com/gpib).
2) For operation at amplitudes of less than 20% of full-scale, best results will be obtained by setting the amplitude near full-scale and using external
attenuators on the output.
) Indicate desired polarity by suffixing model number with -P or -N (i.e. positive or negative) or -PN for dual polarity option.
4) The -OS option adds an internal bias tee circuit to the output, allowing an externally-generated DC offset (±50V/250mA max) to be
added the output signal. The -OT option includes the -OS function, and adds the ability to generate a ±5V/100mA offset internally
(controlled from the front panel, or by computer command on -B units).
5) Add -M to model number for monitor option.
6) A 50 Ohm load is required. Other loads may damage the instrument. Consult Avtech (info@avtechpulse.com) if you need to drive other load
impedances.
7) These instruments are provided with a basic calibration checksheet, showing a selection of measured output parameters. These measurements are
performed with equipment that is calibrated on a regular basis by a third-party ISO/IEC 17025:2005 accredited calibration laboratory. However,
Avtech itself does not claim any accreditation. For applications requiring traceable performance, use a calibrated measurement system rather than
relying on the accuracy of the pulse generator settings.