Skope SERENE SC430N User manual

User Manual
MAN80295 Rev. 1.2 Jan. 2021
SC430N
SERENE Upright Glass Door Fridge
from SKOPE

SC430N
SERENE Single Door Vertical Fridge
User Manual
MAN80295
Rev. 1.2 Jan. 2021
© 2020 SKOPE Industries Limited. All rights reserved.
SKOPE Industries Limited reserve the right to alter specifications without notice.
is a registered trademark of SKOPE Industries Limited.
SKOPE INDUSTRIES LIMITED
Head Office
PO Box 1091, Christchurch
New Zealand
Freephone: 0800 947 5673
E-mail: skop[email protected]
Website: www.skope.com
Trademark Infringement
The SERENE trademark on this product is infringed if the owner, for the time
being, does any of the following:
• Applies the trade mark to the product after their state, condition, get-up or
packaging has been altered in any manner
• Alters, removes (including part removal) or obliterates (including part
obliteration) the trade mark on the product
• Applies any other trade mark to the product
• Adds to the product any written material that is likely to damage the
reputation of the trade mark
Notice of the above contractual obligations passes to:
• Successors or assignees of the buyer
• Future owners of the product

SERENE SC430N
User Manual iii
CONTENTS
1 Installation
Safety First . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Positioning the Fridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Climate Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Fridge Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Stabiliser Feet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Setting Up the Fridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Water Disposal Pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Operation
Automatic Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Defrost Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Door Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Loading Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Electronic Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Temperature Setpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Messages and Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
3 Servicing
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Condenser Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

4Installation
User Manual
SERENE SC430N
1Installation
Safety First Always observe safety precautions when using any electrical appliance. Read
these instructions carefully and retain them for future reference.
Do not use this appliance for other than its intended use.
Do not probe any opening.
Only use this appliance with the voltage specified on the cabinet rating label.
Ensure the appliance has adequate ventilation as this is essential to
economical, high performance.
Be careful not to touch internal moving parts and hot surfaces.
For your own safety and that of others, ensure that all electrical work is done
by authorised personnel.
If the power supply flexible cord becomes damaged, it must be replaced by
an authorised service agent or similarly qualified person in order to avoid a
hazard.
Ensure all necessary safety precautions are observed during installation or
removal of the refrigeration unit.
The appliance is not designed to be stable while in motion. Use extreme
caution when moving or transporting it.
Do not store explosive substances such as aerosol cans with a flammable
propellant in this appliance.
Do not exceed a maximum load of 20kg per shelf.
If the cabinet is to be scrapped, ensure the cabinet is unplugged from the
power supply and cut off the mains flex close to the back of the cabinet. Be
mindful of the risk of animals or children becoming trapped in the appliance -
either remove or secure doors if necessary.
Refrigerant must be removed by a qualified service person and the cabinet
recycled/disposed of in accordance with local regulations.
WARNING
• Ensure the appliance is disconnected from the power supply before
performing any cleaning or maintenance.
• Do not cover the grilles or block the entry or exhaust of airflow by
placing objects up against the refrigeration unit.
• Should manual defrosting be necessary, turn off the refrigeration
system and allow the ice to melt by air circulation. Do not use
mechanical methods to remove ice, as this may damage the
refrigeration circuit.
• Do not use any electrical devices or appliances inside the food
storage compartment.
This cabinet is designed to operate within a specific climatic class environment.
See the cabinet rating label inside the cabinet for climate class number.
Climate class Ambient temperature Relative humidity
325°C 60%
430°C 55%
540°C 40%
7 (tropical) 35°C 75%
The cabinet includes relevant hazard symbols that may be associated with the fridge.
Refer to the information below for symbol description.
WARNING
The refrigeration system contains flammable R290 refrigerant. Do not tamper with it.
The refrigeration system must only be serviced by qualified personnel.

5
SERENE SC430N
Installation
User Manual
Positioning the Fridge
Climate Class This fridge is designed to operate within a climate class 5 environment (40°C
@ 40% RH).
Fridge
Location
The location of the fridge may be the single most important decision that will
extend its life and ensure economical, high performance. Select a suitable
location for the fridge away from direct sunlight and heat sources.
Allow adequate space for the door/s to open and close properly. Self-closing
doors have internal torsion bars pretensioned at the factory.
Ensure the cabinet sits on a level surface so that the door shuts and
correctly seals, and that the doors are unobstructed. Level footing also
prevents the condensate tray from overflowing.
Ventilation Ensure adequate ventilation is provided around the fridge. The fridge should
not be recessed or enclosed in a cabinet, it is designed for free standing
installation only. A 100mm gap must be left behind the cabinet.
Power Cord The fridge is fitted with a 1.7m flexible power cord with a 3-pin plug, which
exits the rear of the refrigeration system. Pull the power cord around so that
it’s not trapped before you position the fridge.
Stabiliser Feet Adjust the front stabiliser feet (see image below) to ensure the fridge sits
firmly on a level surface so that the door shuts and correctly seals. Turn anti-
clockwise to raise and clockwise to lower the stabiliser feet.
CAUTION
To prevent over heating and conserve energy, ensure air flows
freely all around the fridge. There MUST be a minimum
100mm gap behind the fridge.
Fridge Stabiliser Foot

6Installation
User Manual
SERENE SC430N
Setting Up the Fridge
Unpacking Remove all packaging material from the inside and outside of the fridge,
including the foam base and all adhesive tape holding the cabinet shelves
and accessories.
Shelves The fridge is supplied with five wire shelves which may be positioned at
different heights to suit various products. Each shelf is held in place with four
shelf clips which engage in the shelf support strips.
To fit the cabinet shelves
Water
Disposal Pan
Install the water disposal pan to the bottom of the cabinet.
1. Unpack the shelves, shelf clips and ticket strips from inside the cabinet.
2. Clip the ticket strips onto
the front upstand on the
front of the shelves.
3. Establish the desired position for the shelves and securely engage a shelf clip
in each of the shelf support strips.
4. Sit the shelves onto the shelf support clips.
Shelf clip
Shelf support strip
Shelf
water disposal pan

7
SERENE SC430N
Operation
User Manual
2Operation
Automatic Start-Up
After the cabinet has been positioned in a suitable place, plug it in and check
the following activity.
Defrost Switch
If ice accumulates in the cabinet due to extreme operating conditions, a
manual defrost may be performed by switching off the refrigeration using the
switch provided. The cabinet internal fans will continue to run.
Lighting
The cabinet interior lights and sign light can be switched on and off using the
interior light switch, located above the door. Open the door to access the
light switch.
Item Activity
Electronic
Controller
An electronic controller runs the fridge and is visible in a cutout
below the sign. The display panel on the electronic controller
shows the cabinet internal temperature.
Lighting
The lights that illuminate cabinet interior will come on when the
fridge is turned on. If the lights do not come on, check the light
switches on the sign front panel and switch them on (see
“Lighting” below).
Refrigeration
System
The refrigeration system will start a few seconds after the
fridge is turned on.
To verify, listen for the compressor and check that the
refrigeration system light is lit on the electronic controller.
Note: If the cabinet is powered on and off repeatedly, the
compressor may enter protection mode and stay off for 5
minutes.
Light switch Defrost switch

8Operation
User Manual
SERENE SC430N
Door Lock
The fridge is supplied with a door lock bracket, located at the bottom of the
door, which can be fitted with a lock.
Loading Product
Let the fridge run for three hours before loading it with product the first time.
When loading the cabinet shelves with product:
Allow adequate air space around each item to ensure even cooling and
efficient operation of the fridge.
Remove some product if the shelves are flexing. The maximum loading
for each shelf is 20kg.
Do not let anything overhang the shelves, as this might stop the doors
from shutting or even break something.
Door
Door lock bracket
Front panel

9
SERENE SC430N
Operation
User Manual
Electronic Controller
Introduction The fridge is fitted with an electronic controller which is visible through a
cutout below the sign. The electronic controller is pre-programmed and
requires no initial setup or additional programming. SKOPE does not
recommend that the settings be changed unless it is absolutely necessary.
Temperature
Setpoint
The fridge temperature is set to stay between 3.5°C and 5.5°C. The setpoint
can be adjusted to other temperature ranges for specialist applications if
required (see below).
SKOPE DO NOT recommend that the setpoint range be changed unless it
is absolutely necessary, and then only by small increments at a time.
To change the temperature setpoint range
Messages and
Alarms
The following table explains messages and alarms that the electronic
controller displays.
Messages and alarms
1. Refer to the table below to determine the required temperature range.
Set Temperature range Set Temperature range
00.0°C to 1.5°C 53.5°C to 5.5°C
10.5°C to 2.5°C 64.0°C to 6.0°C
21.5°C to 3.5°C 75.0°C to 7.0°C
32.5°C to 4.5°C 86.0°C to 8.0°C
43.0°C to 5.0°C - -
2. Press and hold the up and down buttons on the electronic controller for 3
seconds to unlock the controller.
3. Use the up and down buttons to scroll to the set number assigned to the
required temperature range, as shown in the table above.
4. Once the desired set is displayed, leave the controller for 5 seconds. The
display changes back to the cabinet internal temperature and the new set is
saved.
Display Description
The cabinet internal temperature. The temperature is what the
sensor inside the fridge detects, and not necessarily the product
temperature. However, they may be very close depending on how
the controller is set to sense temperature.
Electronic controller lock indicator. On when the electronic controller
is locked. Off when the electronic controller is unlocked. Press and
hold the up and down buttons for 3 seconds to unlock the electronic
controller.
Compressor indicator. On when the compressor starts. Off when the
compressor stops.
Temperature sensor fault. This indicates a fault with the temperature
sensor. Arrange a service call.

10 Servicing
User Manual
SERENE SC430N
3Servicing
Cleaning
Cabinet Wipe the inside and outside of the cabinet with a damp cloth, taking care to
keep moisture away from electrical parts. As with any maintenance, ensure
the fridge is unplugged from the power supply before cleaning.
Condenser
Coil To ensure trouble-free performance, the condenser coil must be kept clean.
We strongly urge monthly cleaning with a soft brush to remove dust and fluff.
A more thorough cleaning is required by qualified service personnel every
six months. The condenser coil must be kept clean for efficient and reliable
operation.
The condenser coil is located at the front of the cabinet. Unscrew and
remove the rear grille to access the condenser coil for cleaning.
Lighting
The cabinet and sign LED lights are all non-serviceable and must not be
tampered with in any way. If a light is suspected of being faulty, arrange a
service call.
WARNING
Unplug the fridge from the power supply before cleaning the
condenser coil.
Condenser coil

11
SERENE SC430N
Servicing
User Manual
Troubleshooting
For questions about the electronic controller, see page 9. For problems with
the cabinet and refrigeration unit, use the following table.
Problem Possible Cause Suggestions
• Cabinet not operating. • Loss of power supply. • Check mains power supply.
• Controller alarm. • Refer to “Messages and
Alarms” on page 9.
• No controller display. • Loss of power supply. • Check mains power supply.
• Lights not on. • Lights switched off. • Switch light/s on (see page 8)
• Failed light. • Arrange a service call.
• Power consumption is
higher than expected.
• Unit operating too hot. • Clean the condenser.
• Ensure the cabinet is in a
cool spot (see page 6).
• Ensure the cabinet has good
ventilation around the
refrigeration unit (see
page 6).
• Cabinet doors are
opened excessively.
• Ensure doors are closed
more often.
• Product is too warm. • Restricted airflow to
cabinet.
• Ensure product is not
blocking airflow slots.
• Ensure there is space around
individual product pieces.
• Warm cabinet
temperatures.
• Compressor operating
for long periods (more
than 1 hour).
• Blocked condenser. • Clean the condenser.
• Poor ventilation
around refrigeration
unit.
• Ensure the cabinet has good
ventilation around the
refrigeration unit (see
page 6).

SKOPE Contacts
SKOPE Industries Limited
A.B.N. 73 374 418 306
AU: 1800 121 535
NZ: 0800 947 5673
www.skope.com
Other manuals for SERENE SC430N
2
This manual suits for next models
1
Table of contents
Other Skope Freezer manuals

Skope
Skope PG Series User manual

Skope
Skope Centaur Series User manual

Skope
Skope VF Series User manual

Skope
Skope TMEF Series User manual

Skope
Skope PG Series User manual

Skope
Skope ActiveCore User manual

Skope
Skope BC070-CB User manual

Skope
Skope ActiveCore SKFT1500N-A-WG User manual

Skope
Skope ProSpec Series User manual

Skope
Skope VF650 User manual