Skytech TS-3 User manual

Skytech: TS-3 Wired Thermostat REV. 8-30-17 Page 1
INSTALLATION AND OPERATING INSTRUCTIONS
IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS
DO NOT ATTEMPT TO INSTALL OR OPERATE
Model: TS-3
INTRODUCTION
This TS-3 wired wall thermostat was developed to provide a safe, reliable control system for gas heating appliances. The
system can be operated thermostatically or manually from the wall unit.
WALL MOUNT THERMOSTAT
The TS-3 wired thermostat operates on (2) 3V Button Cell (Included) which
powers the LCD screen and circuit board. Before using the TS-3 wall
thermostat the 3V batteries must be installed into the battery
compartments.
It is recommended that CR2032 lithium batteries always be used for
longer battery life and maximum operational performance. If the LCD screen
will not come on, check the 3V Button Cell battery.
ROOM TEMP
THERMO
MODE
“SET”
ON
SET
OFF
LCD
DISPLAY
ON/UP
BUTTON
OFF/DOWN
BUTTON
SET
BUTTON
TO INSTALL BATTERIES IN THE THERMOSTAT (TS-3)
1. Remove face from backing wall plate this is done by sliding the face up
about 1/2” then pull the face off the base plate. As shown in Figure 1.
2. Locate the (2) holders for the 3V button cell batteries (See Figure 2).
3. Slide the button cell batteries into the battery holders. (Make sure that
the batteries are installed with the (+) plus side facing you or up.
4. Reinstall the face to the backing plate this is done by sliding the
face in and down about 1/2” then check that the (2) male terminal
connectors on the face are engaged in the female terminal connectors
on the backing plate. As show in Figure 1.
ROOM TEMP
ON OFF
SET
(2) 3 Volt Button
Cell Batteries
Battery
Removal
Slots
Plus
Side
+
Plus
Side
+
Figure 1 Figure 2

Skytech: TS-3 Wired Thermostat REV. 8-30-17 Page 2
TO REMOVE THE BATTERIES FROM THE THERMOSTAT
1. Remove face from backing plate this is done by sliding the face up about 1/2” then pull the face off the base plate. As
shown in Figure 1.
2. Locate the (2) holders for the 3-volt button cell batteries.
3. Insert a small screwdriver into the slot above the button cell battery and push the battery out. As shown in Figure 2.
4. Reinstall the face to the backing plate this is done by sliding the face in and down about 1/2” then check that the (2)
male terminal connectors on the face are engaged in the female terminal connectors on the backing plate. As show in
Figure 1.
TS-3 THERMOSTAT OPERATION
1. ROOM TEMP – Current room temperature.
2. F° = Degrees Fahrenheit (C° = Degrees Celsius)
3. FLAME ICON – Indicates APPLIANCE IS ON.
4. SET- Indicates TS-3 is in thermostat mode.
5. DASHES – Indicate thermostat mode is being disabled.
Note: The word (SET) will appear when the thermostat mode is
enabled.
ROOM TEMP
12
3
SET
ROOM TEMP
5
4
1. This TS-3 wired wall thermostat has ON, OFF, and SET functions
that are activated by pressing the buttons on the face of the TS-3.
2. If the LCD display will not come ON, check the 3V-button cell battery.
ON
SET
OFF
SETTING MANUAL OPERATION
1. When the ON button on the TS-3 is pressed a ame icon on the LCD
screen will appear when the appliance is ON.
2. When the appliance is OFF the ame icon will not appear.
ROOM TEMP
SETTING THERMOSTAT OPERATION 1. If the TS-3 is in the thermostat mode the word (SET) will appear on
the LCD screen.
2. When the SET button is pressed the temperature digits will begin to
ash.
3. While the temperature digits are ashing use the ON button to
increase the set temperature or use the OFF button to decrease the
set temperature to your desired temperature.
4. When the desired temperature setting is reached press the SET
button, again and the word SET will appear on the LCD screen and
now the thermostat will automatically send an ON or OFF signal to
the appliance.
5. To disengage the thermostat mode push the OFF button or push
and hold the SET button until (2) dashes appear on the LCD screen.
When you release the SET button this will disengage the thermostat
mode and the word SET will disappear from the LCD screen.
ROOM TEMP
SET
ROOM TEMP
SET

Skytech: TS-3 Wired Thermostat REV. 8-30-17 Page 3
SETTING °F / °C SCALE
The factory setting for temperature is degrees Fahrenheit (°F) . To change this setting to Centigrade (°C), you must press
and hold both the ON and OFF buttons on the transmitter at the same time until the LCD displays the change. If you want
to convert back, repeat the above procedure.
THERMO UPDATING FEATURE
This SKYTECH wired wall thermostat has a THERMO UPDATING Feature built into its software. The THERMO
UPDATING Feature operates in the following manner, but only in the THERMOSTAT MODE:
The TS-3 normally reads the ROOM temperature every 2 minutes checking the ROOM temperature against the SET
temperature and then sends a signal to the appliance.
NOTE: When locating the TS-3 on a wall remember it should be kept away from direct sources of heat such as
heating appliance, incandescent lighting, and direct sunlight. Leaving the TS-3 in direct sunlight, for example, will cause
its heat-sensing diode to read the room temperature higher than it actually is; if in THERMOSTAT mode, it may not turn
ON the appliance even if the ambient ROOM temperature is below the SET temperature.
INSTALLATION INSTRUCTIONS
WALL MOUNTING THE TS-3 THERMOSTAT
1. Remove face from backing plate as shown in Figure 1 then locate
the TS-3 to where the (2) thermostat wires from the appliance can
be pulled through the hole on the backing plate and connect them
to the (2) terminal screws.
2. After locating the (2) two mounting holes and mark the holes on
the wall.
3. Use the (2) two dry wall anchors and screws (that are supplied) to
mount the base plate to the wall as shown.
4. Thermostat can also be mounted onto an existing (Plastic)
electrical box.
5. Base plate should be mounted level on the wall for best operation.
6. Reinstall the face to the backing plate this is done by sliding
the face in and down about 1/2” then check that the (2) male
terminal connectors on the face are engaged in the female
terminal connectors on the backing plate. As shown in Figure 1.
ROOM TEMP
ON OFF
SET
WALL
GENERAL INFORMATION
This TS-3 wired wall thermostat must be installed exactly as outlined in these instructions. Read all instructions
completely before attempting installation. Follow instructions carefully during installation. Any modications of the
TS-3 or any of its components will void the warranty and may be pose a re hazard.
Do not connect any gas valve or electronic module directly to 110-120VAC power. Consult gas appliance
manufacturer’s instructions and wiring schematics for proper placement of all wires. All electronic modules are to
be wired to manufacturer’s specications.
WARNING

Skytech: TS-3 Wired Thermostat REV. 8-30-17 Page 4
WIRING INSTRUCTIONS
A qualied electrician or a gas technician who is familiar with the gas appliance and gas valves that will be operated by
this remote should install the remote control system. Incorrect wiring connections WILL cause damage to the gas valve or
electronic module operating the gas appliance and may also damage the remote receiver.
WIRING MILLIVOLT VALVES - ELECTRONIC SPARK IGNITIONS – OTHER APPLIANCES
This TS-3 wired wall thermostat connects to a millivolt gas valve, electronic spark ignition systems or other heating
appliances as shown below in Figure 3, Figure 4, & Figure 5. Connect 18 gauge stranded or solid wires from the TS-3
wired wall thermostat to the gas valve, or electronic module.
TH
TP TP TH
ROOM TEMP
ON OFF
SET
Thermopile &
Pilot Assembly
Terminal Block on
Millivolt Gas Valves
TS-3 Wall Thermostat
Two (2) Screws Terminals
to Connect Wires
from Millivolt Gas Valve
ELECTRONIC MODULE
TR TH
24VAC
120 VAC Input
ROOM TEMP
ON OFF
SET
Netural Wire 110/24VAC
Transformer
Hot Wire
TS-3 Wall Thermostat
Two (2) Screws Terminals
to Connect Wires
from Electronic Module
ROOM TEMP
ON
OFF
SET
TS-3 Wall Thermostat
Two (2) Wires from
Appliance (Not Included)
Two (2) Screw Terminals
to Connect Wires from
Appliance
Other Appliance Power Supply ( Could be
12VAC, 12VDC or 24VAC)
Figure 3 (Millivolt Valves)
Figure 4 (Electronic Spark Systems)
Figure 5 (Other Appliances)

Skytech: TS-3 Wired Thermostat REV. 8-30-17 Page 5
SYSTEM CHECK
MILLIVOLT VALVES - ELECTRONIC IGNITION SYSTEMS – OTHER APPLIANCES
Light your gas appliance following the lighting instructions that came with the appliance. Conrm that the pilot ame is
ON; it must be in operation for the main gas valve to operate, if you have an electronic ignition system check the power
source as well.
• Press the ON button on the TS-3 to turn the system to ON manually. The main ame should come ON.
• Press the OFF button on the TS-3 to turn the system to OFF manually. The main ame should extinguish (the pilot
ame will remain on if you are using a millivolt gas valve system).
• Press the SET button on the TS-3 to change the system to THERMO. Hold the SET button to set the temperature on
the TS-3 to a temperature of a least 2°F (1°C) above the ROOM temperature displayed on the LCD screen. With this
manual setting, the normal thermostatic cycle is overridden and the system ame will ignite. Set the SET temperature
to at least 2°F (1°C) below the room temperature and the system ame will extinguish in a few seconds. Thereafter, it
should continue to cycle to ON and OFF thermostatically approximately every two minutes as the ROOM temperature
changes, but only when the temperature differential between ROOM and SET temperatures differ at least 2°F (1°C).
The 2°F differential is the factory setting.
GENERAL INFORMATION
BATTERY LIFE
Life expectancy of lithium button cell batteries in the TS-3 should be at least (1) season (8) months. Check and replace
both batteries annually.. The TS-3 should operate with as little as 2.4 volts of battery power, measuring at each of the
3-volt button cell batteries.
TROUBLE SHOOTING
Should you encounter problems with your appliance system, the problem may be with the appliance itself or it could be
with the TS-3 wired wall thermostat. Review the appliance manufacturer’s operation manual to make sure all connections
are properly made. Then check the operation of the TS-3 in the following manner:
1. Be sure the TS-3’s batteries are properly installed and that the battery output is 2.4 volts on each battery or more. If
one battery is installed backward the wired wall thermostat will not operate.
2. The TS-3 has (2) 3 volt button cell batteries (1) button cell operates the LCD screen and the other button cell powers
the PCB board. If the button cell battery that controls sending the PCB board is low or defective the LCD screen may
work but the PCB relay may not close the contact (Check each button cell battery)
3. Check that the (2) male terminal connectors on the face are engaged in the female terminal connectors on the backing
plate.
4. Check the wire connections to the TS-3 from the appliance that they are properly connected
SPECIFICATIONS
BATTERIES: TS-3 wired wall thermostat – Uses (2) CR2032 (3VDC lithium button cell) batteries.
FOR TECHNICAL U.S. INQUIRIES CANADIAN INQUIRIES
SERVICE, CALL: (855) 498-8324 or (260) 459-1703 (877) 472-3923
For Sales: (888) 672-8929
Website: skytechpg.com
MANUFACTURED EXCLUSIVELY FOR SKYTECH II, INC

LIMITED WARRANTY
1. Limited Warranty. Skytech II, Inc. (“Skytech”) warrants that each new Skytech Control System, including all
hardware, parts and components (the “System”), when used in accordance with the instructions furnished by Skytech
provided with each System, shall be free in all material respects, of defects in materials and any workmanship under
normal use, subject to proper installation (“Limited Warranty”). This Limited Warranty is non-transferrable and sets
forth our sole and exclusive liability and the sole and exclusive remedies available in relationship to any non-
conformity, defect or similar claim. This Limited Warranty only extends to the original retail purchaser of the System
(the “Customer”) and expires upon any sale or transfer of the home where the System is installed by the Customer.
2. System Sold As Is. Subject to this Warranty and any applicable state law, each System is sold by Skytech to a
Customer on an “as is” basis. In addition, each System and Skytech’s obligations are and remain subject to all
additional disclaimers, limitations, reservations of rights, exclusions, and qualifications set forth on Skytech’s website,
www.skytechpg.com, all of which are considered part of the Warranty and are incorporated herein (collectively, the
“Additional Terms”). Each Customer, by purchasing and/or using any System or any portion thereof, does so subject
to the Warranty and the Additional Terms.
3. Installation and Use of System. Improper Installation, adjustment, alteration, service, or maintenance can cause
property damage, personal injury, or loss of life. Thoroughly read the installation and operating instructions of this
Control as well as the appliance it will be used in conjunction with as a system. If applicable, read the maintenance
instructions before installing this control. This product is designed for use with an attended hearth appliance or fire
feature. Adults must be present when the Control System is operating. DO NOT program or thermostatically set this
Control to operate a hearth appliance or fire feature when Adults are not physically present. Furthermore, DO NOT
leave the hearth appliance or fire feature burning unattended; it may cause damage or serious injury. If an Adult is
going to be away from the hearth appliance or fire feature for any length of time, then the handheld/wall mount,
receiver/control module and application should be in the “OFF” position.
4. Repair or Replacement of System or Parts. Should any System, or any hardware, components and/or parts
contained therein fail due to a defect in workmanship or material provided by Skytech after the purchase of a System
by a Customer, Skytech shall repair or, at its option, replace the defective System or part, hardware or component,
subject to the Customer’s compliance with all terms and conditions contained herein governing service and claims
under the Warranty. Skytech shall provide replacement parts at no charge for the first (5) five years of this warranty, and at
market cost for the Lifetime of the product to the original Customer. Gas valve and gas valve components will be available
at no charge for one (1) year. If Skytech does not have the parts for an individual model, then a comparable replacement
System will be provided at no charge within the first (5) five years after purchase, and then at market cost for the Lifetime of
that product to the Customer.
5. Warranty Claims; Skytech Service. To submit a valid claim under the Warranty (each, a “Valid Claim”), a Customer
must comply with the following:
a) Obtain a Return Material Authorization (“RMA”) number from Skytech by calling (855) 498-8324; and
b) Provide written notice to a Skytech or an Authorized Dealer (“Dealer”) and provide the Name, House Address, Email
Address and Telephone Number of the Customer;
c) Describe the System model number and nature of the defect, nonconformity, or other problem with the System;
d) Provide such notice within thirty (30) days of discovery of such defect, nonconformity, or problem;
e) securely pack and ship the defective Skytech Product to Skytech II, Inc. ATTN: Warranty Department at 9230 Conservation
Way, Fort Wayne, IN 46809. Customer assumes all costs and risks associated with transportation to Skytech (i) the RMA
number is only valid for thirty (30) days from the date the RMA was issued, (ii) the RMA number should be clearly marked
on the outside of each box being returned. Skytech may refuse shipments that DO NOT meet all of the Valid Claim
requirements. Skytech is not responsible for any refused shipments or any damage caused due to shipping, whether or not
it was a Valid Claim. Skytech shall be responsible for return shipment charges. Compliance with these requirements is a
condition to coverage under this Limited Warranty.
Skytech may refuse any shipment(s) that does not meet all of the Valid Claim requirements. Skytech is not responsible for
any refused shipments or any damage caused due to shipping, whether or not it was a Valid Claim. Skytech shall be
responsible for reasonable return shipment charges for any Skytech System returned whether or not Skytech
determines there is no defect with the System, reject for failure of the Customer to submit a Valid Claim, or otherwise
determine is not eligible for service under the Warranty.
Upon receipt of a Valid Claim and the properly-returned System, Skytech shall, at its option, either (a) repair the System,
at no charge to the Customer, or (b) replace the returned System with a new comparable System, at no charge to the
Customer, or (c) provide the Customer with a refund in an amount equal to the price paid by the Customer for the
defective System not including any service or labor cost associated with the installation or otherwise. Any System or

hardware, component or part repaired by Skytech hereunder, or any replacement System, hardware, component or
part shall be shipped to the Customer by Skytech at Skytech’s cost and the Warranty, the Additional Terms, and all
other terms and conditions set forth herein shall extend to such repaired or replacement System, hardware,
component or part. Skytech shall pay no refund before Skytech from the Customer receives the defective System,
hardware, component and/or parts. Any obligation of Skytech under this Section 4 shall be and remain subject to
Skytech’s right to physically inspect the defective System, hardware, component and/or part returned to Skytech by
the Customer. Some States do not allow the exclusion or limitation of incidental and consequential damages or limitation
on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific rights
and you may have
other rights, which vary from state, province, or nation. To the extent allowable under any law, the liability
of Skytech is limited to the express terms of this warranty, and Skytech expressly disclaims any and all implied warranties,
including any warranties of fitness for a particular purpose or merchantability
REV. 2-24-17
Print information and detach at dotted line for return to: Skytech, ATTN WARRANTY DEPT., 9230 Conservation Way, Fort Wayne, IN 46809
Telephone: (855) 498-8324
Warranty Information
Purchase Date: Model: Date Code:
Purchased From:
Customer Name: Phone:
Back of remote Date Code Sample
16’
17’
1-12 is Month remote was produced
15-16 is Year remote was produced
Sample date code above is 1611
Address:
Email Address: ____________________________________________________________________
City: State/Prov. Zip/Postal Code:
Please send a Proof of Purchase (original receipt) copy along with your Warranty form.

Santa’s Helper
Exclusive offer to Skytech Remote Control Owners
This special offer is only provided to customers of Skytech that have purchased a remote control for
their Hearth Product. This remote control system can be used for any 120VAC appliance, but perfect
your Christmas Tree Lights or any other appliance that is difficult to reach or plug in. Simply plug the
receiver into your wall outlet and your appliance into the receiver, push the ON button on the
transmitter and you are in business. It’s that easy!
The list price of $48.00 for the Santa’s Helper has been cut almost in half to $20.00 USD for this
exclusive offer. Shipping and handling of $5.00 $USD should be added. Send us your check, money
order or call us with your credit card number, along with the warranty information from your remote
control of your Hearth Product. You can also send it via mail, fax, or e-mail.
Skytech Products Group
9230 Conservation Way
Fort Wayne, IN 46809
1-(888) 672-8929
1-(888) 672-8024 Fax
Table of contents
Other Skytech Thermostat manuals
Popular Thermostat manuals by other brands

industrie technik
industrie technik DBTV instructions

Jung
Jung BT 1791 Series operating instructions

Watts
Watts SunTouch Sunstat ConnectPlus manual

Amana
Amana 2246002 Installation, operation & application guide

Full Gauge Controls
Full Gauge Controls Microsol FLT Advanced quick start guide

Honeywell
Honeywell VisionPRO Wi-Fi TH8320WF System setup