SE20 & SE25 & SE30 & SE40
Electrical Specifi cations
EN MC_0044
*Valid for DC motors
Model Size System
Voltage
Nominal
current
draw
Min. battery
CCA Rec. fuse
<7m total + & - 7-14m total + & - 15-21m total + & - 22-28m total + & - 28-35m total + & - 36-45m total + & -
Min. Rec. Min. Rec. Min. Rec. Min. Rec. Min. Rec. Min. Rec.
*20/110S 12 V 150 A
DIN: 200
SAE: 380
EN: 330
ANL 150
mm2 25 35 35 50 50 70 70 95 95 95 120 2 x 70
AWG 3 2 2 1/0 1/0 2/0 2/0 3/0 3/0 3/0 2 x 4/0 2 x 2/0
*25/110S 12 V 200 A
DIN: 200
SAE: 380
EN: 330
ANL 150
mm2 25 35 50 50 70 70 95 95 120 120 2 x 70 2 x 70
AWG 3 2 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 2 x 2/0 2 x 2/0
*30/125S
*30/140 12 V 245 A
DIN: 200
SAE: 380
EN: 330
ANL 150
mm2 35 50 50 70 70 95 95 120 120 2 x 70 2 x 70 2 x 95
AWG 2 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 2 x 2/0 2 x 2/0 2 x 3/0
*40/125S
*40/140 12 V 315 A
DIN: 300
SAE: 570
EN: 520
ANL 250
mm2 35 50 70 95 95 120 120 2 x 70 2 x 95 2 x 95 2 x 120 2x 120
AWG 2 1/0 2/0 3/0 3/0 4/0 4/0 2 x 2/0 2 x 3/0 2 x 3/0 2 x 4/0 2 x 4/0
*50/140S
12 V 370 A
DIN: 350
SAE: 665
EN: 600
ANL 325
mm2 50 50 70 95 120 2 x 70 2 x 70 2 x 95 2 x 95 2 x 120 2 x 120 2 x 120
AWG 1/0 1/0 2/0 3/0 4/0 2 x 2/0 2 x 2/0 2 x 3/0 2 x 3/0 2 x 4/0 2 x 4/0 2 x 4/0
24 V 170 A
DIN: 175
SAE :332
EN: 280
ANL 150
mm2 25 25 25 35 35 50 35 50 50 70 70 70
AWG 3 3 3 2 2 1/0 2 1/0 1/0 2/0 2/0 2/0
*60/185S
*60/140
12 V 370 A
DIN: 350
SAE: 665
EN: 600
ANL 325
mm2 50 50 70 95 120 2 x 70 2 x 70 2 x 95 2 x 95 2 x 120 2 x 120 2 x 120
AWG 1/0 1/0 2/0 3/0 4/0 2 x 2/0 2 x 2/0 2 x 3/0 2 x 3/0 2 x 4/0 2 x 4/0 2 x 4/0
24 V 170 A
DIN: 175
SAE: 332
EN: 280
ANL 150
mm2 25 25 25 35 35 50 35 50 50 70 70 70
AWG 3 3 3 2 2 1/0 2 1/0 1/0 2/0 2/0 2/0
*80/185T
12 V 530 A
DIN: 550
SAE: 1045
EN: 940
ANL 400
mm2 70 70 120 2 x 70 2 x 95 2 x 95 2 x 120 2x 120 2 x 120
NA NA NA
AWG 2/0 2/0 4/0 2 x 2/0 2 x 3/0 2 x 3/0 2 x 4/0 2 x 4/0 2 x 4/0
24 V 280 A
DIN: 300
SAE:570
EN: 520
ANL 250
mm2 35 35 35 50 50 70 70 95 95 120 120 2 x 95
AWG 2 2 2 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 2 x 3/0
*100/185T
12 V 740 A
DIN: 750
SAE: 1425
EN: 1320
ANL 500
mm2 95 95 2 x 70 2 x 95 2 x 120
NA NA NA NA NA NA NA
AWG 3/0 3/0 2 x 2/0 2 x 3/0 2 x 4/0
24 V 340 A
DIN: 400
SAE: 760
EN: 680
ANL 325
mm2 50 50 50 70 70 95 95 120 120 2 x 95 2 x 95 2 x 120
AWG 1/0 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 2 x 3/0 2 x 3/0 2 x 4/0
*120/215T 24V 420 A
DIN: 450
SAE: 855
EN: 760
ANL 325
mm2 70 70 70 70 70 95 95 120 120 2 x 70 2 x 70 2 x 95
AWG 2/0 2/0 2/0 2/0 2/0 3/0 3/0 4/0 4/0 2 x 2/0 2 x 2/0 2 x 3/0
*130/250T
12V 800 A
DIN: 750
SAE: 760
EN: 680
ANL 500
mm2 95 95 2 x 95 2 x 95 2 x 120 2 x 120
NA NA NA NA NA NA
AWG 3/0 3/0 2 x 2/0 2 x 3/0 2 x 4/0 2 x 4/0
24V 350 A
DIN: 400
SAE: 760
EN: 680
ANL 325
mm2 50 50 50 70 70 95 95 120 120 2 x 70 2 x 95 2 x 95
AWG 2 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 2 x 2/0 2 x 3/0 2 x 3/0
*150/215T 24V 610 A
DIN: 560
SAE: 1064
EN: 940
ANL 500
mm2 70 70 95 95 120 120 2 x 70 2 x 95 2 x 95 2 x 120 2 x 120 2 x 120
2 2/0 2/0 3/0 3/0 4/0 4/0 2 x 2/0 2 x 3/0 2 x 3/0 2 x 4/0 2 x 4/0 2 x 4/0
*170/250 24V 550 A
DIN: 560
SAE: 1064
EN: 940
ANL 400
mm2 70 70 70 95 95 120 120 2 x 95 2 x 95 2 x 95 2 x 120 2 x 120
AWG 2/0 2/0 2/0 3/0 3/0 4/0 4/0 2 x 3/0 2 x 3/0 2 x 3/0 2 x 4/0 2 x 4/0
*210/250 24V 500 A
DIN: 560
SAE: 1330
EN: 940
ANL 400-
500
mm2 70 70 70 95 95 120 120 2 x 70 2 x 70 2 x 95 2 x 95 2 x 120
AWG 2/0 2/0 2/0 3/0 3/0 4/0 4/0 2 x 2/0 2 x 2/0 2 x 3/0 2 x 3/0 2 x 4/0
*250/300 24V 610-670 A
DIN: 700
SAE: 1330
EN: 1170
ANL 500
mm2 70 70 95 120 120 2 x 95 2 x 95 2 x 95 2 x 95 2 x 120 2 x 120 2 x 120
AWG 2/0 2/0 3/0 4/0 4/0 2 x 3/0 2 x 3/0 2 x 3/0 2 x 3/0 2 x 4/0 2 x 4/0 2 x 4/0
*300/300
24*2 400-450A
(48V)
DIN: 400
SAE: 760
EN: 680
ANL 325
mm2 50 70 50 70 70 95 95 120 120 120 140
NA
48V AWG 1/0 2/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 4/0 4/0
Multi-lug configuration
causes overheating and fire. Spring
washers must be placed in the outer
position before tightening the nut.
- All power cable lengths represent the total length of the combined (+) and (-) cables.
- Battery capacity is stated as minimum cold crank capacity, (CCA).
- Consider the AMP hours (Ah) for your specifi c duty cycle.
- See electrical specifi cations for advised minimum cables and batteries (CCA).
- Ensure the main switch (battery isolator) can be turned off independently and manually when not on board or in emergencies.
(NB: For Ignition Protected installations remember to use ignition protected fuses and switches if fi tted in areas that require this feature.
Ensure to follow your national regulations)
5. Cable lugs must have adequate electrical and mechanical isolation and fi tted with cable lug covers.