SMAJAYU R26 User manual

SMAJAYU(SHENZHEN) CO.,LTD
Address: 1
Room 213-214, Building 1, Mingliang Science Park, No. 88, Zhuguang North Road, Taoyuan
Street, Nansh an District, Shenzhen Web:
www.smajayu.com
CONTENT
Preface ...................................................................................................................................................................... 2
The R26 base can be used for two purposes: ..........................................................................2
1. R26 Device .......................................................................................................................................................... 2
1.1 Device List ............................................................................................................................................... 2
1.2 Device Hardware ...................................................................................................................................2
1.3 R26 Main Body: ..................................................................................................................................... 4
2 R26 as base station ........................................................................................................................................... 6
2.1 Set R26 as base station .......................................................................................................................6
3 Static measurement Guide .............................................................................................................................7
3.1 Abstract ....................................................................................................................................................7
3.2 Static measurement steps ................................................................................................................. 7
3.3 Static measurement data export .....................................................................................................8

SMAJAYU(SHENZHEN) CO.,LTD
Address: 2
Room 213-214, Building 1, Mingliang Science Park, No. 88, Zhuguang North Road, Taoyuan Street,
Nansh an District, Shenzhen Web: www.smajayu.com
Preface
The R26 base can be used for two purposes:
1. Work as a radio base station or mobile station with other radio RTK or
agricultural systems;
2. For static measurements
This article will explain these two usages in detail
1. R26 Device
1.1 Device List
Table 1 Device List
No.
Name
Quantity
Note
1
R26
1
2
Data Cable
1
3
Power Adapter
1
4
Radio Antenna
1
Stick
5
Device Box
1
1.2 Device Hardware
Ⅰ. R26
Height 139mm.
The maximum diameter 136mm

SMAJAYU(SHENZHEN) CO.,LTD
Address: 3
Room 213-214, Building 1, Mingliang Science Park, No. 88, Zhuguang North Road, Taoyuan Street,
Nansh an District, Shenzhen Web: www.smajayu.com
Ⅱ. Data Cable
POW/COM plug which connects to R26.
DC power supply plug.
DB9 data configuration plug.
USBD raw data export and save plug.

SMAJAYU(SHENZHEN) CO.,LTD
Address: 4
Room 213-214, Building 1, Mingliang Science Park, No. 88, Zhuguang North Road, Taoyuan Street,
Nansh an District, Shenzhen Web: www.smajayu.com
Ⅲ. Power Adapter
Input: British Standard Plug.
Output: DC Plug.
Ⅳ. Radio Antenna
Frequency: 450-470MHZ.
Dimension: 280mm.
Ⅴ. Device Box
1.3 R26 Main Body:

SMAJAYU(SHENZHEN) CO.,LTD
Address: 5
Room 213-214, Building 1, Mingliang Science Park, No. 88, Zhuguang North Road, Taoyuan Street,
Nansh an District, Shenzhen Web: www.smajayu.com
:Still recording button: Press and hold for 4 seconds to turn on or off the
still recording mode.
: Recorder light: red, flashes when the static recording mode is turned on,
otherwise off.
: Satellite light: red, RTK Fix is always on..
:Differential light: red, flashes once per second when the radio or 4G
module receives or sends data, and does not flash when there is no differential
data.
: Power light: three-color light, light blue when charging, green when fully
charged, red when working, and red flashing when the battery is less than 5%.
: Power button: Press and hold for 2 seconds to turn on or off (Bluetooth
will also be turned on).
: 9 PIN aviation plug, including power supply, COM RS232, CONFIG RS232.
: UHF radio antenna interface.
Fixed Thread: Five-eighth inch thread.
Figure 6 R26 Main Body

SMAJAYU(SHENZHEN) CO.,LTD
Address: 6
Room 213-214, Building 1, Mingliang Science Park, No. 88, Zhuguang North Road, Taoyuan Street,
Nansh an District, Shenzhen Web: www.smajayu.com
2 R26 as base station
NOTE:
When using with other radio RTK, you need to pay attention to whether the
protocol is consistent. R26 supports TRIMTALK, TRIMMK3, TT450S, and
TRANSEOT protocols.
2.1 Set R26 as base station
(1) Install SMAJAYU Survey software on your Android device.
Download link:
https://drive.google.com/drive/folders/1oIlQo2Gw4ENeq8bYQxF7
zar0tugk-yDw?usp=share_link
(2) Set up and start R26, open the survey software (make sure the
device where the software is located has turned on Bluetooth): Device
--> Communication --> Device Para --> Select your device number
(same as SN) --> Connnect.

SMAJAYU(SHENZHEN) CO.,LTD
Address: 7
Room 213-214, Building 1, Mingliang Science Park, No. 88, Zhuguang North Road, Taoyuan Street,
Nansh an District, Shenzhen Web: www.smajayu.com
(3) Device --> Base --> Set base station startup parameters --> Set
Base Startup
Tips:
The unactivated software can only simply set the base station or mobile station,
if you want to unlock all the surveying and mapping functions, please contact us to
buy R26 rover + handheld to get the activated software.
3 Static measurement Guide
3.1 Abstract
This paper mainly introduces how to switch to the static measurement
mode, and how to export the static measurement data and the specific
operation steps.
3.2 Static measurement steps
⑴Set up R26 at the control point

SMAJAYU(SHENZHEN) CO.,LTD
Address: 8
Room 213-214, Building 1, Mingliang Science Park, No. 88, Zhuguang North Road, Taoyuan Street,
Nansh an District, Shenzhen Web: www.smajayu.com
⑵Record the instrument number, point name, instrument height and
start time.
⑶Power on, set R26 to static mode (two ways)
①Press and hold the still recording button for 4 seconds to turn on
still recording mode.
②Connect R26 with LP80 and set it to static mode
The Rocorder light will flash when the static mode is turned on,
and the data will be recorded once per second.
⑷Press and hold the still recording button for 4 seconds to turn off
still recording mode,end measurement;
3.3 Static measurement data export
(1) After completing the static measurement, as shown in the figure,
insert the usb port of the setting line into the computer, and the
nine-pin port into R26.

SMAJAYU(SHENZHEN) CO.,LTD
Address: 9
Room 213-214, Building 1, Mingliang Science Park, No. 88, Zhuguang North Road, Taoyuan Street,
Nansh an District, Shenzhen Web: www.smajayu.com
(2) The computer will pop up a folder, copy the txt file you want to
convert in the folder to the specified folder on the computer.

SMAJAYU(SHENZHEN) CO.,LTD
Address: 10
Room 213-214, Building 1, Mingliang Science Park, No. 88, Zhuguang North Road, Taoyuan Street,
Nansh an District, Shenzhen Web: www.smajayu.com
(3) Open the software and select the txt file to convert. The converted
files are saved in the folder where txt is located.
Other manuals for R26
1
Table of contents
Other SMAJAYU Receiver manuals