If you are getting any error lights please see below for more information.
KP1 Error lights
Please see below for explanations of any error lights you may encounter. Please note that you will
need to power down the unit before making any of the suggestions below, then power up the unit
again once complete.
•Red LED – No 2nd Camera. If the config file has a second camera enabled this error light will
display. You can either plug in a second camera or ignore this LED. As long as the blue and
green LEDs are also solid the unit will still test correctly.
•No Green LED – 3G USB dongle error. Check the dongle is inserted correctly and that the
settings have applied to the card correctly.
•Flashing green LED – SIM not inserted correctly. Take the dongle out and check that SIM
card is present and inserted correctly.
•All flashing lights – No SD card or card not formatted. Check the SD card is inserted correctly
and then check that the card initialised correctly and has the correct settings.