SMART SP-75 Installation guide

PUMPS
PUMP
MANUAL
PUMP
MANUAL
Care and Instructions
SP-75, SP-130,
SP-160
VP-300, VP-600,
VP-1150, VP-1650,
VP-2250
SUBMERSIBLE PRO
VARIABLE PRO
SP Series
VP Series
For further information on this or other products,
please contact Smart Solar customer service.
Tel: 813.343.5775 • Email: [email protected] • www.smartsolar.com
©2009 Smart Solar Inc. All Rights Reserved
®
®

Infinity™Magnetic Drive Variable Flow
Performance Pump Kits
SP Submersible Series and VP In-line & Submersible
Series
The Infinity SP and VP series of pumps are high quality
products designed using the latest technological
improvements in water gardening today. These pumps
are suitable for use in ponds, aquariums, fountains,
filters, statuary and aquatic gardens. These pumps
have been developed on the basis of synchronous
technology whereby the electrical parts have been fully
encapsulated in epoxy resin.
The pumps have an economical, powerful and reliable
motor. The SP series is suitable to be used submersibly
in fresh water. The Infinity VP series of pumps are
suitable for installation on dry land for in-line use or
they can be used submersibly in fresh and salt water.
The VP series are equipped with a ceramic shaft
which allows for their use in salt water applications.
Infinity pumps are carefully inspected and tested
to insure both safety and operating performance.
However, failure to follow the instructions and warnings
in this manual may result in pump damage and/or
serious injury. Be sure to read and save this manual
for future reference.
WARNING
The National Electric Code requires that a ground
fault circuit interrupter (GFCI) be used in the branch
circuit supplying electric water pumps and other pond/
aquatics equipment. For any information regarding
the proper installation required for this pump please
contact your local electrical supplies dealer or a
licensed electrician.
Do not remove the grounding pin from the plug.
Do not connect to any voltage other than that
shown on the pump.
Do not pump any liquids other than fresh water
(fresh or salt for VP series) as specifically noted in
the owner’s manual.
Do not use with water above 86°F (30°C.)
Some models of Infinity pumps are equipped with an
internal thermal protector switch that will automatically
turn off the pump in the case of overheating. Once the
pump is cooled, the unit will restart provided that no
irreversible damage has occurred.
Risk of electric shock: This pump is supplied with a
grounding connector and grounding type attachment
plug. To reduce the risk of electric shock, be certain
that the pump is connected only to a properly grounded,
grounding-type electrical receptacle.
NOTE: Insure that the
electrical cord loops
below the electrical
outlet to form a “Drip
Loop”. This will prevent
water from running
down the cord and into
the electrical outlet.
CAUTION & SAFETY WARNINGS
Check that the power supply is properly rated and
fused. If the pump or the power cable does not comply
with your local electrical code standards – DO NOT
connect the pump to the equipment.
To reduce the risk of electrical shock, unplug the power
cord from the receptacle before handling the pump at
any time.
Always disconnect the power before cleaning the
pump or when performing maintenance on the pond or
water area where the pump is being used. This includes
draining or changing the water in your aquatic feature
or putting any part of your body into the water.
Do not connect the pump to the electrical supply while
the pump is out of the water.
Do not lift the pump by the power cord or by pulling
on the cable.
The electrical supply cord of this pump cannot be
replaced. If the power cord is damaged, the pump
should be discarded. Never remove the plug or shorten
the cable. Your guarantee is invalidated if you attempt
to alter the construction of the unit in any way.
Operate the pump completely submerged for proper
cooling (SP Series and VP Series when not used in-line).
Never let the pump run dry as this will damage the
impeller and may also overheat the pump and burn out
the electrical coil.
Never allow the water level in your water feature to
fall below the top of the pump body.
Do not use this product in bathrooms.
Do not use this product if the body of the unit becomes
damaged, swollen or cracked in any way.
If the pump becomes noisy, replace the impeller since
this is a wearable part.
Keep the connection (plug and socket) dry at all times.
The pump is NOT suitable for use in swimming pools,
swimming ponds or other situations where people
could make bodily contact with the water.
Infinity™Pumps - Care & Instructions Infinity™Pumps - Care & Instructions
PUMP BODY
IMPELLER
IMPELLER
COVER
FRONT COVER
PUMP BODY
IMPELLER
IMPELLER
COVER
FRONT COVER
FILTER
SP Series Parts Diagram
VP Series Parts Diagram

Infinity™Pumps - Care & Instructions Infinity™Pumps - Care & Instructions
Infinity™SP Series of Submersible
Variable Flow Pumps
Models SP-75, SP-130 & SP-160
Please be sure to read these instructions carefully
before you begin installation and use.
1. Place the pump in a suitable location using the
rubber suction feet as additional support if possible.
The unit must be fully submerged in the water since
this will cool the unit.
2. Place the pump in a location where water can be
circulated around the pump.
3. Turn the flow control valve clockwise to increase
the water flow, turn the flow control valve counter-
clockwise to reduce the water flow.
4. Clean the impeller at least every month. The impeller
is situated in the pump housing and can be accessed
by holding the pump body and rotating the impeller
cover and pulling the pump cover away from the
main body.
5. Clean the impeller in fresh water and the housing
with cotton buds or similar to remove any and
all accumulated debris from the pump and then
re-assemble.
The electricity supply cord must extend below the
plug socket; this is to prevent water drops from making
contact with the plug or electricity supply outlet –
this is called a “drip loop”. See diagram in the
WARNING section.
Infinity™VP Series of In-line/
Submersible Variable Flow Pumps
Models VP-300, VP-600, VP-1150,
VP-1650 & VP-2250
Please be sure to read these instructions carefully
before you begin installation and use.
1. Place the pump in a suitable location using the
rubber suction feet as additional support if possible.
Never let the pump run dry.
2. Place the pump at least 6” and no more than 36”
below the water on a stable surface that is free
from sludge, sand and other debris. Allow for
adequate water circulation around the pump for
maximum performance.
3. Add fountain extension pipes so that the fountain
head is above the surface of the water.
4. Turn the flow control valve clockwise to increase
the water flow, turn the flow control valve counter-
clockwise to reduce the water flow.
The cascading water bell nozzle (if so equipped and
provided) is adjusted by turning the top piece of the
head higher for a smaller bell and by turning the top
piece of the head lower for a wider shaped bell.
MAINTENANCE & CLEANING
The Infinity Series of pumps do not require lubrication
or special maintenance. The following maintenance
and cleaning will improve your pump’s performance
and life.
Carry out routine maintenance when the pump flow is
visibly reduced. Switch off the electricity and remove
the pump for the water source (DO NOT use the cable
to lift the pump out) and firmly pull off the pre-filter
cage from the pump motor (Fig. 1). Remove pre-filter
foam and clean thoroughly in fresh water. A blocked
foam filter will reduce the pump flow rate. Regular
maintenance: remove the impeller cover by turning the
in-line housing counter-clockwise while pushing in to
release the lock (Fig. 2). Once unlocked, firmly pull the
cover away from the pump motor (Fig. 3). Carefully
remove the impeller locator (small round washer if
applicable) and the impeller unit (Fig. 4). Wash parts
with fresh water and clean thoroughly. Once you have
cleaned the pump, re-assemble in reverse order (Fig. 5).
Your actual cleaning frequency will be based on your
specific use conditions.
Do not allow the pump to operate in below freezing
conditions (32°F) since this will
cause the pump to freeze up
and become inoperable.
In freezing conditions,
remove the pump from
the use area
and store in
a frost-free
location.
SP Series Pump
VP Series pump
Fig. 1 - Remove pre-filter cage
Fig. 2 - Unlock impeller cover Fig. 3 - Remove impeller cover
Fig. 4 - Remove impeller unit Fig. 5 - Reassemble

Infinity™Pumps - Care and Instructions Technical Information
TROUBLESHOOTING
If the pump fails to operate, check
the following:
Check the circuit breaker and try
another outlet to insure the pump
is getting electrical power. Note:
Always disconnect from electrical
outlet before handling the pump.
Check the pump discharge and
tubing for kinks and obstructions.
Algae build-up can be flushed out
with a garden hose.
Check the inlet screen or filter
sponge to insure it is not clogged
with debris.
Remove the pump inlet to access
the impeller area. Turn the rotor
to insure that it is not broken or
jammed.
WARRANTY
This pump is warranted to the original purchaser against defective material and workmanship under
normal use for a period of three years from the date of purchase. Replacement liability in all events
is limited to the repair or replacement of the pump in the sole discretion of Smart Solar Inc. which is
found to be defective in material or workmanship. Proof of purchase is required on all claims in the
form of a dated purchase slip affixed to the enclosed warranty registration card.
Application: This warranty covers only properly installed and maintained units. Warranty is limited
to applications pumping fresh water (SP Series) or fresh water and marine water (VP series) at
temperatures above 32°F and below 86°F (0°C – 30°C), with a pH range of 5 to 9. Other liquid
applications and extreme temperature uses void this warranty.
Claims handling: All USA warranty claims should be made by returning the defective pump, freight
prepaid along with a copy of the completed warranty registration card to Smart Solar. Please call
813-343-5775 to obtain a return authorization and the location of the service center nearest to you.
All returned items will be inspected to determine the cause of failure before warranty is approved.
Removal charges: This warranty does not cover any costs associated with the installation, removal
or re-installation of any products subject to warranty claims.
Disposition: Smart Solar will promptly handle your claim and advise you of disposition generally within
72 hours of receipt. In the event of products damaged in transit, Smart Solar will advise you and you
will need to file a claim with the sending carrier.
Disclaimer: Any oral statements about the product(s) made by the seller, the manufacturer, the
representatives or any other parties do not constitute warranties, are not part of the contract for sale
and are not to be relied upon by the user. Seller’s and manufacturer’s sole obligation, and buyer’s and
user’s only remedy shall be for Smart Solar to either repair or replace, at Smart Solar’s sole discretion,
the Infinity pump product as described above. Neither seller or Smart Solar shall be liable for any
injury, loss or damage, direct, incidental or consequential (including, but not limited to, incidental
or consequential damages for lost profits, lost sales, personal injury, property damage, or any other
incidental or consequential loss not specifically mentioned herein), arising from any cause whatsoever,
no matter whether based upon warranty, contract, negligence or other misuse, and the buyer and
user agree that no other remedy shall be available to them. Smart Solar shall not be held liable for
the loss of any fish, plants or other livestock as a result of any failure or defect of this product. Before
using, the buyer and user shall determine the suitability of the product for the intended use, and
assumes all risk and liability whatsoever in connection therewith. The warranty and remedy described
in this limited warranty is an EXCLUSIVE warranty and remedy and IN LIEU of any other warranty or
remedy, expressed or implied, which other warranties and remedies are hereby expressly EXCLUDED,
including but not limited to any implied warranty of MERCHANTABILITY or FITNESS FOR A
PARTICULAR PURPOSE. This warranty gives the buyer and the user specific legal rights, and the
buyer and the user may also have other rights which vary from state to state. Some states do not
allow the exclusion or limitations of incidental or consequential damages, so the above limitation
may not apply to you.
Limitation: This warranty specifically excludes the sponge filter and the impeller unit, which are normal
wear items and may require annual replacement depending on actual usage conditions. If you require
replacement for these parts, please contact your dealer or Smart Solar directly at 813-343-5775.
VP Series in-line and submersible pump – Ceramic shaft, magnetic drive, sealed epoxy
Max Cable
STI Max Min Height Length Impeller Fresh Salt
Model Watts GPH GPH (feet) Outlet (feet) Shaft Water Water
VP-300 17 300 175 6.50 1/2” 16 Ceramic Y Y
3/4”
VP-600 40 600 250 7.50 1/2” 16 Ceramic Y Y
3/4”
VP-1150 70 1,150 300 9.00 3/4” 16 Ceramic Y Y
1”
VP-1650 145 1,650 500 12.50 3/4” 16 Ceramic Y Y
1”
VP-2250 226 2,250 550 16.50 3/4” 16 Ceramic Y Y
1”
1-1/4 ”
SP Fountain Series submersible pump – Stainless steel shaft, magnetic drive, sealed epoxy
SP-75 5.5 75 35 1.50 3/8” 6 Stainless Y N
Steel
SP-130 10 130 45 4.30 3/8” 6 Stainless Y N
1/2” Steel
SP-160 13 160 50 5.50 3/8” 6 Stainless Y N
1/2” Steel

SP-75 / SP-130 SP-160 VP-300 VP-600
Attachments included with the
SP-75 and SP-130 Pumps:
#1 - Connector
#2 - Connector
#1
#2
Attachments included with the
SP-160 Pump:
#1 - Connector
#2 - Connector
#3 - Connector
#4 - Single Volcano Nozzle
#5 - Water Bell Nozzle
#6 - Flow Control
#7 - Raising Pipe
Attachments included with the
VP-300 Pump:
#4 - Single Volcano Nozzle
#8 - Flow Control
#9 - Water Bell Nozzle
#10 - Long Raising Pipe
#11 - Long Raising Pipe
#12 - Short Raising Pipe
#13 - Water Inlet #14 - Water Outlet
#15 - Water Outlet
#4
#5
#6
#7
#4
#8
#9 #10
#11
#12
#13
#14 #15
Attachments included with the
VP-600 Pump:
#14 - Water Outlet #15 - Water Outlet
#16 - Water Bell Nozzle
#17 - Double Volcano Nozzle
#18 - Single Volcano Nozzle
#19 - Flow Control #20 - Flat Cover
#21 - Water Outlet #22 - Water Outlet
#23 - Water Intake Inlet
#14 #15
#16 #17 #18
#19
#20
#21
#22
#23
NOTE: All attachments pictured are
not shown in proportional scale with
attachments in the other photos. They
are shown for easy identification only.
#3
#1
#2

VP-1150 VP-2250
Attachments included with the
VP-2250 Pump:
#20 - Flat Cover
#21 - Water Outlet #22 - Water Outlet
#29 - Cascade Bell Insert for Narrow Bell Shapes
#30 - Cascade Bell with Large Bell Shape Insert
#31 - Volcano Nozzle
#32 - Water Intake Inlet
#33 - Flow Control #34 - Water Outlet
#35 - Water Outlet #36 - Water Outlet
Attachments included with the
VP-1650 Pump:
#16 - Water Bell Nozzle
#17 - Double Volcano Nozzle
#18 - Single Volcano Nozzle
#20 - Flat Cover
#21 - Water Outlet #22 - Water Outlet
#24 - Water Intake Inlet
#25 - Flow Control
#26 - Water Outlet #27 - Water Outlet
#28 - Foaming Nozzle
#28 #17 #18 #16
#23
#24
#25
#26 #27
#20
#21
#22
#30
#29
#31
#32 #33
#34
#35 #36
VP-1650
Attachments included with the
VP -1150 Pump:
#14 - Water Outlet #15 - Water Outlet
#16 - Water Bell Nozzle
#17 - Double Volcano Nozzle
#18 - Single Volcano Nozzle
#19 - Flow Control #20 - Flat Cover
#21 - Water Outlet #22 - Water Outlet
#23 - Water Intake Inlet
#14 #15
#16 #17 #18
#19
#20
#21
#22
#23
#20
#21
#22
This manual suits for next models
15
Table of contents
Popular Water Pump manuals by other brands

Bell and Gossett
Bell and Gossett Series 100 instruction manual

Varian
Varian VHS-10 instruction manual

Ashland
Ashland ANC200 OPERATION, PERFORMANCE, SPECIFICATIONS and PARTS MANUAL

Champion Power Equipment
Champion Power Equipment 66520 Operator's manual

Metabo
Metabo TP 7500 Si operating instructions

Oase
Oase Aquarius Universal Classic 600 operating instructions

Pfeiffer Vacuum
Pfeiffer Vacuum UNO 6 operating instructions

Samoa
Samoa 536631 Parts and technical service guide

Einhell Royal
Einhell Royal GP JET 1300 NIRO operating instructions

Simer
Simer 3307P owner's manual

SFA
SFA SANICONDENS CLIM MINI installation instructions

BRINKMANN PUMPS
BRINKMANN PUMPS SBA141 Series operating instructions