2014 Compacta International, Ltd. - Rev. 2/2019
ZBPLM and Smartenit are trademarks of Compacta International, Ltd.
ZigBee is a registered trademark of the ZigBee Alliance, INSTEON is a registered trademark of SmartLabs, Inc.,
and X10 is a registered trademark of X10.
DB9 Serial Port
USB Port
ZBPLM is a mul-protocol interface that allows communicaon
from a computer or any device to control and monitor ZigBee,
INSTEON and X10 home automaon devices.
The ZBPLM also enables the setup and interoperability
between ZigBee Home Automaon (HA) devices without the
requirement of a computer.
With the seamless integraon of these three leading home and
building automaon protocols, the limitaons of what you can
accomplish start to disappear!
Program Buon
Status LED
Note: ZBPLM must be installed indoors
Now with
external antenna* for
increased range
(not shown)
* Serial version only
* Serial version only
(949) 429-3303
Technical Support
Smartenit.com
Quick Start Guide - ZBPLMTM
Product Brief
Installation
Home Automation Interface
Interface Setup
1. Using with Serial API:
• This method is typically for developers. ZBPLM implements the Smartenit Serial API, which is documented here:
hp://docs.smartenit.com/soware/zbpcid_api.pdf
2. Using with Smartenit Gateways/Hubs:
• Follow installaon process menoned above and then aach the other end of USB cable to Gateway/Hub
3. Using with IoT8-Z as an Insteon bridge. Follow steps below and then refer to the IoT8-Z quick start guide
• Factory reset ZBPLM: Press buon while reconnecng to power and connue to hold buon for 4 secs
• Start Network: Tap the set buon 11 mes in quick succession. LED should stop blinking and stay solid.
• Discover zigbee device: Press and hold the Set buon for 7 secs, LED should start to blink slowly
1. Connect ZBPLM to Computer or Gateway
• Using cable provided (RJ-45 to DB9 or USB), connect
ZBPLM to computer/gateway. (If USB version, connect
USB cable aer compleng step 3 below)
2. Connect external antenna and point upwards *
3. Connect ZBPLM to 120V AC power
• Press and hold the Program Buon while plugging into power to
ensure ZBPLM is reset to factory defaults.
• Aer a couple seconds, the LED will begin to blink, indicang
that ZBPLM is reset.