SmartSpas Orbit Spa Quick start guide

OWNERS INSTALLATION MANUAL
PORTABLE SPA HOT TUBS
R
EVISED
07/2009

IMMEDIATELY
UPON DELIVERY
REGISTER YOUR HOT TUB
THIS INFORMATION IS
VERY IMPORTANT
TO ENSURE
WARRANTY COVERAGE
AND
RECEIVE INFORMATION
FOR POSSIBLE
PRODUCT UPDATES.

S
MART
S
PAS
O
WNER
’
S
M
ANUAL
C
ONGRATULATIONS
ON
C
HOOSING
A
QUALITY
S
MART
S
PA
FOR
YOUR
BACKYARD
RELAXATION
!
P
LEASE
READ
THE
O
WNER
’
S
M
ANUAL
COMPLETELY
BEFORE
INSTALLING
AND
USING
YOUR
NEW
SPA
. T
HE
PURPOSE
OF
THIS
MANUAL
IS
TO
PROVIDE
YOU
WITH
SAFETY
,
OPERATIONAL
AND
INSTALLATION
INFORMATION
WHICH
WILL
ALLOW
YOU
THE
FULLEST
ENJOYMENT
OF
THIS
FINE
PRODUCT
.
A
T
THE
TIME
OF
PRINTING
,
THIS
MANUAL
WAS
DEEMED
AS
ACCURATE
AS
POSSIBLE
. PDC S
PAS
RESERVES
THE
RIGHT
TO
CHANGE
PRODUCT
IN
AN
EFFORT
TO
ENHANCE
AND
IMPROVE
,
WITHOUT
PRIOR
NOTICE
. T
O
BE
AWARE
OF
ANY
OF
THESE
POSSIBLE
CHANGES
,
LOG
ON
TO
WWW
.
PDCSPAS
.
COM
,
REFERRING
TO
THE
C
USTOMER
C
ARE
SEC-
TION
,
OR
CONTACT
YOUR
RETAILER
DIRECTLY
.
O
WNERSHIP
I
NFORMATION
N
AME
___________________________________________________
A
DDRESS
___________________________________________________
___________________________________________________
___________________________________________________
I
NSTALLATION
D
ATE
____ / ____ / ____
M
ODEL
N
AME
_____________________
S
ERIAL
# _________________________
R
ETAILER
N
AME
_____________________________
R
ETAILER
P
HONE
N
UMBER
_____________________
S
ERVICE
T
ECHNICIAN
C
ONTACT
I
NFO
___________________________
___________________________________________________
S
ERIAL
# L
OCATION
SERIAL
NUMBER
PLATE
IS
BEHIND
CABINET
P
ANEL
ON
WALL
OF
HOT
TUB
BEHIND
THE
CONTROL
.
SAVE THIS MANUAL FOR EASY FUTURE REFERENCE !

I
MPORTANT
S
AFETY
I
NSTRUCTIONS
W
ARNINGS
, I
NSTRUCTIONS
FOR
A
LL
S
PA
M
ODELS
1-6
S
PA
U
SE
L
ABELS
L
OCATION
AND
R
EFERENCE
7
S
PA
P
ARTS
I
DENTIFICATION
S
PA
P
ART
T
ERMINOLOGY
AND
D
ESCRIPTION
8
S
UPPORT
E
QUIPMENT
T
ERMINOLOGY
AND
D
ESCRIPTION
9
S
PA
S
PECIFICATIONS
10-13
S
PA
I
NSTALLATION
S
PA
L
OCATION
C
ONSIDERATIONS
, I
NDOORS
AND
O
UTDOORS
14, 15
G
ENERAL
L
OCATION
C
ONSIDERATIONS
16
E
QUIPMENT
L
OCATION
17
I
NSTALLING
THE
T
HERMAL
C
OVER
18
W
IRING
I
NSTALLATION
W
IRING
R
ECOMMENDATIONS
19
U.S. –S
TATE
-
SIDE
G
UIDELINES
20
E
XPORT
,
IN
.
XE
CE
P
LATFORM
21
I
NITIAL
S
TART
-U
P
G
ENERAL
G
UIDELINES
22
O
PERATION
S
YSTEMS
I
N
.K 200 C
ONTROL
23-25
W
ATER
C
HEMISTRY
G
UIDELINES
26, 27
M
AINTENANCE
R
ECOMMENDATIONS
28, 29
W
INTERIZING
YOUR
HOT
TUB
30
T
ROUBLESHOOTING
31
R
ECORDS
OF
S
PA
C
ARE
32
T
ABLE
OF
C
ONTENTS

SAVE THESE INSTRUCTIONS
I
NCLUDED
WITH
THIS
MANUAL
IS
A
SAFETY
SIGN
THAT
IS
TO
BE
POSTED
NEAR
THE
SPA
WHERE
ALL
OCCUPANTS
CAN
EASILY
READ
. T
HIS
SIGN
IS
INTENDED
FOR
YOU
AND
YOUR
GUEST
’
S
PROTECTION
,
SAFETY
AND
TO
ASSURE
THEIR
SPA
ENJOYMENT
. T
AKE
THE
TIME
TO
POINT
OUT
THE
LOCATION
OF
THE
SIGN
AND
INDICATE
THE
IMPORTANCE
OF
THE
PRECAUTIONS
.
A
DHERE
THE
SIGN
WITH
SCREWS
OR
ANOTHER
MANNER
OF
PERMANENT
ADHESION
.
S
HOULD
YOU
REQUIRE
ADDITIONAL
COPIES
OR
REPLACEMENTS
,
SIMPLY
CONTACT
THE
FACTORY
DIRECTLY
OR
YOUR
NEAREST
RETAILER
.
WARNING
T
HIS
UNIT
IS
A
PROFESSIONAL
-
GRADE
PRODUCT
.
A
KNOWLEDGE
OF
CONSTRUCTION
TECHNIQUES
,
PLUMBING
AND
ELECTRICAL
INSTALLATION
ACCORDING
TO
CODES
ARE
REQUIRED
FOR
PROPER
INSTALLATION
AND
USER
SATISFACTION
. I
T
IS
RECOMMENDED
THAT
A
LICENSED
CONTRACTOR
PERFORM
THE
INSTALLATION
.
W
ARRANTY
IS
VOIDED
FOR
IMPROPER
I
NSTALLATION
RELATED
ISSUES
.
Y
OU
NOW
OWN
A
HIGH
QUALITY
S
MART
S
PA
BUILT
FOR
YEARS
OF
ENJOYMENT
AND
RELAXATION
. I
T
IS
OF
PRIME
IMPORTANCE
THAT
YOU
UNDERSTAND
THE
OPERATION
OF
YOUR
SPA
AND
ENJOY
IT
WITH
SAFETY
IN
MIND
. Y
OU
SHOULD
READ
THIS
MANUAL
THOROUGHLY
AND
UNDERSTAND
ALL
OF
THE
SAFETY
PRECAUTIONS
. U
SING
YOUR
SPA
WITHIN
THESE
GUIDELINES
ASSURES
YEARS
OF
FUN
AND
RELAXATION
GAINED
FROM
ADDING
A
S
MART
S
PA
TO
YOUR
LIFESTYLE
.
S
AFETY
I
NSTRUCTIONS
1

READ AND FOLLOW
ALL INSTRUCTIONS!!
T
HIS
UNIT
IS
A
PROFESSIONAL
-
GRADE
PRODUCT
. A
KNOWLEDGE
OF
CONSTRUCTION
TECHNIQUES
,
PLUMBING
AND
ELECTRICAL
INSTALLATION
ACCORDING
TO
CODES
ARE
REQUIRED
FOR
PROPER
INSTALLATION
AND
USER
SATISFACTION
. I
T
IS
RECOMMENDED
THAT
A
LICENSED
CONTRACTOR
PERFORM
THE
INSTALLATION
. W
ARRANTY
IS
VOIDED
FOR
IMPROPER
I
NSTALLATION
RELATED
ISSUES
.
I
T
IS
THE
RESPONSIBILITY
OF
THE
HOME
OWNER
TO
ENSURE
THAT
ALL
USERS
OF
THE
SPA
ARE
ADEQUATELY
INFORMED
OF
ALL
PRECAUTIONS
.
U
SE
THE
SPA
ONLY
AS
DESCRIBED
IN
THIS
MANUAL
. T
HE
SPA
IS
INTENDED
FOR
HOME
USE
ONLY
. D
O
NOT
USE
THE
SPA
IN
A
COMMERCIAL
OR
RENTAL
SETTING
. A
LL
WARRANTIES
WILL
BE
VOIDED
.
GROUND ALL METAL ELECTRICAL EQUIPMENT
• A
GREEN
COLORED
TERMINAL
OR
A
TERMINAL
MARKED
G, GR, G
ROUND
,
OR
G
ROUNDING
,
IS
LOCATED
INSIDE
THE
SUPPLY
TERMINAL
BOX
OR
COMPARTMENT
. T
HIS
TERMINAL
MUST
BE
CONNECTED
TO
THE
GROUNDING
MEANS
PROVIDED
IN
THE
ELECTRIC
SUPPLY
SERVICE
PANEL
,
USING
A
CONTINUOUS
COPPER
WIRE
EQUIVALENT
IN
SIZE
TO
THE
CIRCUIT
CONDUCTORS
SUPPLYING
THIS
EQUIPMENT
.
*
ACCORDING
TO
,
BUT
NOT
LIMITED
TO
: NEC, NFPA 70, S
ECTION
680.40, UL 1563.
• A
T
LEAST
TWO
LUGS
MARKED
“B
ONDING
L
UGS
”
ARE
PROVIDED
ON
THE
EXTERNAL
SURFACE
OR
ON
THE
INSIDE
OF
THE
SUPPLY
TERMINAL
BOX
OR
COMPARTMENT
. C
ONNECT
THE
LOCAL
COMMON
BONDING
GRID
(
HOUSEHOLD
GROUND
)
IN
THE
AREA
OF
THE
SPA
TO
THESE
TERMINALS
,
USING
AN
INSULATED
OR
BARE
COPPER
CONDUCTOR
NOT
SMALLER
THAN
N
O
. 6 AWG.
• A
LL
FIELD
-
INSTALLED
METAL
COMPONENTS
SUCH
AS
RAILS
,
LADDERS
,
DRAINS
OR
SIMILAR
HARDWARE
LOCATED
WITHIN
5
FEET
OF
THE
SPA
OR
HOT
TUB
MUST
BE
BONDED
TO
THE
EQUIPMENT
GROUNDING
BUS
WITH
COPPER
CONDUCTORS
NOT
SMALLER
THAN
N
O
. 6 AWG.
• A
LL
METAL
SURFACES
WITHIN
5
FEET
OF
THE
SPA
MUST
BE
BONDED
TO
THE
HOME
BONDING
GRID
.
GROUND FAULT CIRCUIT INTERRUPTER PROTECTION
(OR EQUIVALENT; RCD, FOR EXPORT INSTALLS)
• A
LL
PDC S
PAS
ARE
PERMANENTLY
INSTALLED
UNITS
. GROUND FAULT CIRCUIT INTERRUPTER
PROTECTION IS REQUIRED. A
LL
SPA
EQUIPMENT
SYSTEMS
MUST
BE
PROTECTED
BY
A
CLASS
A
GROUND
FAULT
CIRCUIT
INTERRUPTER
(GFCI)
OR
EQUIVALENT
; RCD,
FOR
EXPORT
INSTALLS
. A
GROUND
FAULT
CIRCUIT
INTERRUPTER
TYPE
CIRCUIT
BREAKER
(NOT SUPPLIED)
MUST
BE
INSTALLED
IN
THE
HOME
PANEL
BOX
BY
A
LICENSED
ELECTRICIAN
WHEN
MAKING
WIRE
CONNECTION
TO
THE
SPA
SUPPORT
PACK
EQUIPMENT
.
DANGER: RISK OF ELECTRICAL SHOCK:
• I
NSTALL
THE
SPA
AT
LEAST
FIVE
FEET
(1.52
M
)
FROM
ALL
UNGROUNDED
(
UNBOUNDED
)
METAL
SURFACES
.
• G
ROUND
FAULT
CIRCUIT
INTERRUPTER
PROTECTION
OF
THE
HOME
POWER
SUPPLY
TO
THE
SPA
IS
NECESSARY
. Y
OUR
ELECTRICIAN
SHOULD
EXPLAIN
HOW
IT
WORKS
. (S
EE
SPA
MAINTENANCE
)
•
D
O
NOT
PERMIT
ANY
ELECTRIC
APPLIANCE
,
SUCH
AS
A
LIGHT
,
TELEPHONE
,
RADIO
OR
TELEVISION
,
WITHIN
FIVE
FEET
(1.52
M
)
OF
A
SPA
. K
EEP
ELECTRICAL
APPLIANCES
AND
EXTENSION
CORDS
AWAY
FROM
THE
SPA
. W
ATER
IS
A
CONDUCTOR
OF
ELECTRICITY
.
READ AND FOLLOW ALL IMPORTANT SAFETY INSTRUCTIONS
W
HEN
INSTALLING
AND
USING
THIS
EQUIPMENT
BASIC
SAFETY
PRECAUTIONS
SHOULD
ALWAYS
BE
TAKEN
TO
REDUCE
THE
RISK
OF
ELECTRICAL
SHOCK
,
TO
ENSURE
SAFE
USAGE
,
AND
TO
SAFEGUARD
THE
USER
’
S
HEALTH
.
S
AFETY
I
NSTRUCTIONS
2

DANGER: RISK OF ACCIDENTAL DROWNING.
• E
XTREME
CAUTION
MUST
BE
EXERCISED
TO
PREVENT
UNAUTHORIZED
ACCESS
BY
CHILDREN
. T
O
AVOID
ACCIDENTS
,
ENSURE
THAT
CHILDREN
CANNOT
USE
A
SPA
UNLESS
THEY
ARE
SUPERVISED
AT
ALL
TIMES
.
DANGER: TO REDUCE THE RISK OF DROWNING:
1. N
EVER
USE
THE
SPA
ALONE
.
2. C
HILDREN
SHOULD
NOT
USE
THE
SPA
UNLESS
THEY
ARE
SUPERVISED
BY
AN
ADULT
3. K
EEP
PETS
AWAY
FROM
THE
SPA
AT
ALL
TIMES
.
4. ALWAYS REPLACE AND LOCK THE SPA COVER WHEN THE SPA IS NOT IN USE.
DANGER: TO REDUCE THE RISK OF DROWNING
• P
ROLONGED
IMMERSION
IN
THE
SPA
MAY
CAUSE
HYPERTHERMIA
. T
HE
CAUSES
,
SYMPTOMS
AND
EFFECTS
OF
HYPERTHERMIA
MAY
BE
DESCRIBED
AS
FOLLOWS
: H
YPERTHERMIA
OCCURS
WHEN
THE
INTERNAL
TEMPERATURE
OF
THE
BODY
REACHES
A
LEVEL
SEVERAL
DEGREES
ABOVE
THE
NORMAL
BODY
TEMPERATURE
OF
98.6 °F (37°C). T
HE
SYMPTOMS
OF
HYPERTHERMIA
INCLUDE
AN
INCREASE
IN
THE
INTERNAL
TEMPERATURE
OF
THE
BODY
,
DIZZINESS
,
LETHARGY
,
DROWSINESS
,
AND
FAINTING
. T
HE
EFFECTS
OF
HYPERTHERMIA
INCLUDE
:
1. F
AILURE
TO
PERCEIVE
HEAT
2. F
AILURE
TO
RECOGNIZE
THE
NEED
TO
EXIT
THE
SPA
3. U
NAWARENESS
OF
IMPENDING
HAZARD
4. F
ETAL
DAMAGE
IN
PREGNANT
WOMEN
5. P
HYSICAL
INABILITY
TO
EXIT
THE
SPA
6. U
NCONSCIOUSNESS
RESULTING
IN
THE
DANGER
OF
DROWNING
DANGER: RISK OF INJURY
• D
O
NOT
REMOVE
THE
SUCTION
FITTINGS
. T
HE
SUCTION
FITTING
IN
THIS
SPA
IS
SIZED
TO
MATCH
THE
SPECIFIC
WATER
FLOW
CREATED
BY
THE
PUMP
. S
HOULD
THE
NEED
ARISE
TO
REPLACE
THE
SUCTION
FITTING
OR
THE
PUMP
,
BE
SURE
THAT
THE
FLOW
RATES
ARE
COMPATIBLE
. N
EVER
OPERATE
THE
SPA
IF
THE
SUCTION
FITTING
IS
BROKEN
OR
MISSING
. N
EVER
REPLACE
A
SUCTION
FITTING
WITH
ONE
RATED
LESS
THAN
THE
FLOW
RATE
MARKED
ON
THE
ORIGINAL
SUCTION
FITTING
.
DANGER: RISK OF ACCIDENTAL DROWNING
• K
EEP
HAIR
AND
BODY
PARTS
AWAY
FROM
THE
SUCTION
GUARD
. D
O
NOT
ALLOW
LONG
HAIR
TO
FLOAT
FREELY
IN
THE
WATER
;
LONG
HAIR
SHOULD
BE
RESTRAINED
WITH
A
BATHING
CAP
. T
O
REDUCE
THE
RISK
OF
DROWNING
FROM
HAIR
OR
BODY
ENTRAPMENT
,
INSTALL
A
SUCTION
FITTING
(
S
)
WITH
A
MARKED
FLOW
RATE
IN
GALLONS
PER
MINUTE
THAT
EQUALS
OR
EXCEEDS
THE
FLOW
RATE
MARKED
ON
THE
EQUIPMENT
ASSEMBLY
,
IF
REPLACEMENT
OF
SUCTION
FITTINGS
BECOMES
NECESSARY
.
WARNING
• G
ROUND
FAULT
CIRCUIT
INTERRUPTER
PROTECTION
(GFCI)
OR
EQUIVELANT
; RCD,
FOR
THE
SPA
SHOULD
BE
TESTED
PRIOR
TO
EACH
USE
BY
THE
HOMEOWNER
. W
ITH
THE
SPA
IN
OPERATION
,
PUSH
THE
“
TEST
”
BUTTON
ON
THE
GFCI
CIRCUIT
BREAKER
AT
THE
PANEL
BOX
. T
HE
SPA
SHOULD
SHUT
DOWN
IM-
MEDIATELY
. N
OW
RESET
THE
GFCI. T
HE
SPA
SHOULD
RETURN
TO
NORMAL
OPERATION
. I
F
THE
GFCI
FAILS
TO
OPERATE
IN
THIS
MANNER
,
THERE
EXISTS
A
POSSIBILITY
OF
ELECTRICAL
SHOCK
. A
PPROVED
TESTING
APPLIES
FOR
EXPORT
PROTECTION
DEVICES
,
I
.
E
. RCD.
• D
ISCONTINUE
SPA
OPERATION
BY
DISCONNECTING
THE
POWER
SOURCE
AND
NOTIFY
A
QUALIFIED
ELEC-
TRICIAN
FOR
IDENTIFICATION
AND
CORRECTION
OF
THE
PROBLEM
.
S
AFETY
I
NSTRUCTIONS
3

WARNING
• T
O
REDUCE
THE
RISK
OF
INJURY
,
DO
NOT
PERMIT
CHILDREN
TO
USE
THIS
PRODUCT
UNLESS
THEY
ARE
CLOSELY
SUPERVISED
AT
ALL
TIMES
.
WARNING: TO REDUCE THE RISK OF INJURY
• T
HE
WATER
IN
A
SPA
SHOULD
NEVER
EXCEED
104ºF (40°C). W
ATER
TEMPERATURES
BETWEEN
100°F
(38º C )
AND
104º F (40°C)
ARE
CONSIDERED
SAFE
FOR
A
HEALTHY
ADULT
. L
OWER
WATER
TEMPERATURES
ARE
RECOMMENDED
FOR
EXTENDED
USE
(
EXCEEDING
10
TO
15
MINUTES
)
AND
FOR
YOUNG
CHILDREN
.
• E
XCESSIVE
WATER
TEMPERATURES
HAVE
A
HIGH
POTENTIAL
FOR
CAUSING
FETAL
DAMAGE
DURING
THE
EARLY
MONTHS
OF
PREGNANCY
. P
REGNANT
OR
POSSIBLY
PREGNANT
WOMEN
SHOULD
LIMIT
SPA
TEMPERATURES
TO
100º F (38°C).
• B
EFORE
ENTERING
A
SPA
,
THE
USER
SHOULD
MEASURE
THE
WATER
TEMPERATURE
WITH
AN
ACCURATE
THERMOMETER
SINCE
THE
TOLERANCE
OF
WATER
TEMPERATURE
REGULATING
DEVICES
MAY
VARY
AS
MUCH
AS
5º F (3°C).
•
THE USE OF ALCOHOL, DRUGS, OR MEDICATION BEFORE OR DURING SPA USE
MAY LEAD TO UNCONSICIOUSNESS WITH THE POSSIBILITY OF DROWNING.
• P
ERSONS
SUFFERING
FROM
OBESITY
OR
WITH
A
MEDICAL
HISTORY
OF
HEART
DISEASE
,
LOW
OR
HIGH
BLOOD
PRESSURE
,
CIRCULATIORY
SYSTEM
PROBLEMS
,
OR
DIABETES
SHOULD
CONSULT
A
PHYSICIAN
BEFORE
USING
A
SPA
.
• P
ERSONS
USING
MEDICATION
SHOULD
CONSULT
A
PHYSICIAN
BEFORE
USING
A
SPA
SINCE
SOME
MEDICATION
MAY
INDUCE
DROWSINESS
WHILE
OTHER
MEDICATION
MAY
AFFECT
HEART
RATE
,
BLOOD
PRESSURE
,
AND
CIRCULATION
.
• E
NTER
AND
LEAVE
SPA
SLOWLY
AND
WITH
CAUTION
. S
URFACES
AROUND
SPA
WILL
BE
WET
AND
SLIPPERY
.
WARNING
1. N
EVER
USE
THE
SPA
ALONE
.
2. D
O
NOT
BRING
ANY
OBJECT
INTO
THE
SPA
THAT
COULD
DAMAGE
THE
SPA
SHELL
.
3. D
O
NOT
SIT
ON
SPA
COVER
OR
PLACE
OBJECTS
ON
IT
;
IT
IS
NOT
DESIGNED
TO
SUPPORT
WEIGHT
.
4. R
EMOVE
ANY
WATER
OR
DEBRIS
THAT
MAY
COLLECT
ON
THE
SPA
COVER
.
5. K
EEP
ALL
CHEMICALS
AWAY
FROM
CHILDREN
AND
PETS
.
6. T
HE
PH
AND
CHEMICAL
BALANCE
OF
THE
WATER
MUST
BE
MAINTAINED
AS
EXPLAINED
IN
THIS
MANUAL
. F
AILURE
TO
DO
SO
MAY
CAUSE
INJURY
TO
USERS
OR
DAMAGE
TO
THE
SPA
,
AND
WILL
VOID
YOUR
WARRANTY
.
WARNING: HEALTH CONSIDERATIONS
• T
HE
USE
OF
ALCOHOL
,
DRUGS
,
MEDICATION
CAN
GREATLY
INCREASE
RISK
OF
FATAL
HYPERTHERMIA
.
• I
NDIVIDUALS
WITH
INFECTIONS
AND
OPEN
SORES
OR
WOUNDS
SHOULD
NOT
USE
THE
SPA
. B
ACTERIA
THRIVE
IN
WARM
AND
HOT
WATER
. A
LWAYS
KEEP
YOUR
SPA
DISINFECTED
AND
MAINTAIN
THE
PROPER
CHEMICAL
BALANCE
.
• S
HOWER
BEFORE
AND
AFTER
USING
THE
SPA
. T
HIS
WILL
REMOVE
ANY
DEODORANT
,
PERSPIRATION
,
OR
BODY
OILS
THAT
COULD
CONTAMINATE
THE
WATER
. S
HOWERING
AFTER
WILL
REMOVE
ANY
RESIDUAL
CHEMICALS
AND
ANY
BACTERIA
THAT
MAY
HAVE
BEEN
IN
THE
SPA
.
S
AFETY
I
NSTRUCTIONS
4

• D
O
NOT
USE
THE
SPA
IMMEDIATELY
AFTER
STRENUOUS
EXERCISE
.
• I
F
YOU
FEEL
PAIN
OR
DIZZINESS
AT
ANY
TIME
WHILE
USING
THE
SPA
,
DISCONTINUE
USE
AND
CONTACT
A
PHYSICIAN
.
WARNING: TO REDUCE THE RISK OF INJURY
• I
T
IS
ESPECIALLY
IMPORTANT
FOR
PERSONS
OVER
THE
AGE
OF
35
OR
PERSONS
WITH
PRE
-
EXISTING
HEALTH
PROBLEMS
,
SUCH
AS
OBESITY
,
HEART
DISEASE
,
HIGH
BLOOD
PRESSURE
,
CIRCULATORY
PROBLEMS
,
OR
DIABETES
TO
CONSULT
THEIR
PHYSICIAN
BEFORE
USING
THE
SPA
.
• T
HE
SPA
JETS
PRODUCE
A
STREAM
OF
WATER
WITH
RELATIVELY
HIGH
PRESSURE
. P
ROLONGED
EXPO-
SURE
OF
A
LOCALIZED
AREA
OF
THE
BODY
MAY
CAUSE
BRUISES
TO
THE
SKIN
.
• N
EVER
INSERT
ANY
OBJECT
INTO
ANY
OPENING
.
• D
O
NOT
USE
BREAKABLE
CONTAINERS
IN
OR
NEAR
THE
SPA
.
WARNING: ELECTRICAL CONSIDERATIONS
• F
OR
CONTROLS
OTHER
THAN
UNDERWATER
LIGHTING
CIRCUITS
: A G
ROUND
F
AULT
C
IRCUIT
I
NTER-
RUPTER
(
OR
EQUIVELANT
FOR
EXPORT
INSTALLS
)
MUST
BE
PROVIDED
IF
THIS
DEVICE
IS
USED
TO
CON-
TROL
AN
UNDERWATER
LIGHTING
FIXTURE
. T
HE
CONDUCTORS
ON
THE
LOAD
SIDE
ON
THE
G
ROUND
F
AULT
C
IRCUIT
I
NTERRUPTER
SHALL
NOT
OCCUPY
CONDUIT
,
BOXES
,
OR
ENCLOSURES
CONTAINING
OTHER
CONDUCTORS
UNLESS
THE
ADDITIONAL
CONDUCTORS
ARE
ALSO
PROTECTED
BY
A
G
ROUND
F
AULT
C
IRCUIT
I
NTERRUPTER
(
OR
EQUIVALENT
FOR
EXPORT
INSTALLS
).
• T
HE
ELECTRICAL
SUPPLY
FOR
THIS
PRODUCT
MUST
INCLUDE
A
SUITABLY
RATED
SWITCH
OR
CIRCUIT
BREAKER
TO
OPEN
ALL
UNDERGROUND
SUPPLY
CONDUCTORS
TO
COMPLYWITH
S
ECTION
422-20
OF
THE
U.S. N
ATIONAL
E
LECTRIC
C
ODE
. T
HE
DISCONNECTING
MEANS
MUST
BE
READILY
ACCESSIBLE
TO
THE
TUB
OCCUPANT
BUT
INSTALLED
AT
LEAST
5 FT (1.5 M)
FROM
THE
SPA
WATER
.
WARNING: F
OR
SPAS
WITH
AUDIO
/
VIDEO
COMPONENTS
1. CAUTION - R
ISK
OF
E
LECTRIC
S
HOCK
. D
O
NOT
LEAVE
COMPARTMENT
DOOR
OPEN
.
2. CAUTION - R
ISK
OF
E
LECTRIC
S
HOCK
. R
EPLACE
COMPONENTS
ONLY
WITH
IDENTICAL
COMPONENTS
;
AND
,
3. D
O
NOT
OPERATE
THE
AUDIO
/
VIDEO
CONTROLS
WHILE
INSIDE
THE
SPA
.
4.
WARNING
- P
REVENT
E
LECTROCUTION
. D
O
NOT
CONNECT
ANY
AUXILIARY
COMPONENTS
(
FOR
EXAMPLE
CABLE
,
ADDITIONAL
SPEAKERS
,
HEADPHONES
,
ADDITIONAL
AUDIO
/
VIDEO
COMPONENTS
,
ETC
.)
TO
THE
SYSTEM
.
5. T
HESE
UNITS
ARE
NOT
PROVIDED
WITH
AN
OUTDOOR
ANTENNAE
;
WHEN
PROVIDED
,
IT
SHOULD
BE
INSTALLED
IN
ACCORDANCE
WITH
A
RTICLE
810
OF
THE
U.S. N
ATIONAL
E
LECTRICAL
C
ODE
,
ANSI/NFPA 70.
6. D
O
NOT
SERVICE
THIS
PRODUCT
YOURSELF
AS
OPENING
OR
REMOVING
COVERS
MAY
EXPOSE
YOU
TO
DANGEROUS
VOLTAGE
OR
OTHER
RISK
OF
INJURY
. R
EFER
ALL
SERVICING
TO
QUALIFIED
SERVICE
PERSONNEL
.
7. W
HEN
THE
POWER
SUPPLY
CONNECTION
OR
POWER
SUPPLY
CORD
(
S
)
ARE
DAMAGED
;
IF
WATER
IS
ENTERING
THE
AUDIO
/
VIDEO
COMPARTMENT
OR
ANY
ELECTRICAL
EQUIPMENT
COMPARTMENT
AREA
;
IF
THE
PROTECTIVE
SHIELDS
OR
BARRIERS
ARE
SHOWING
SIGNS
OF
DETERIORATION
;
OR
IF
THERE
ARE
SIGNS
OF
OTHER
POTENTIAL
DAMAGE
TO
THE
UNIT
,
TURN
OFF
THE
UNIT
AND
REFER
SERVICING
TO
QUALIFIED
SERVICE
PERSONNEL
.
8. T
HIS
UNIT
SHOULD
BE
SUBJECTED
TO
PERIODIC
ROUTINE
MAINTENANCE
(
FOR
EXAMPLE
,
ONCE
EVERY
3
MONTHS
)
TO
MAKE
SURE
THAT
THE
UNIT
IS
OPERATING
PROPERLY
.
S
AFETY
I
NSTRUCTIONS
5

ADDITIONAL SAFETY CONSIDERATIONS
• I
NSTALL
THE
SPA
TO
PROVIDE
DRAINAGE
FOR
COMPARTMENTS
OF
ELECTRICAL
COMPONENTS
.
• F
OR
FLOOR
RECESSED
SPAS
: I
NSTALL
TO
PERMIT
ACCESS
FOR
SERVICING
FROM
ABOVE
OR
BELOW
THE
FLOOR
. S
PA
EQUIPMENT
MUST
BE
INSTALLED
BELOW
WATER
LEVEL
.
• W
HEN
PLANNING
YOUR
SPA
INSTALLATION
SITE
,
PREPARE
FOR
THE
UNLIKELY
EVENT
OF
RAPID
SPA
DRAINAGE
.
• D
O
NOT
PLACE
SPA
IN
DIRECT
SUNLIGHT
WHILE
UNIT
IS
EMPTY
OR
WHEN
SEALED
IN
SHIPPING
MATERIALS
. E
XCESSIVE
HEAT
BUILD
MAY
CAUSE
DAMAGE
TO
SPA
AND
VOID
WARRANTY
.
• I
NSTALL
SPA
SO
THAT
WATER
CAN
EASILY
BE
DRAINED
OUT
,
LOCATING
THE
SIDE
DRAIN
VALVE
ON
THE
SPA
SPECIFICATION
LISTING
.
• W
HEN
INSTALLING
SPA
,
ALLOW
AMPLE
SPACE
FOR
FUTURE
SERVICING
,
NOTING
LOCATION
OF
ALL
SUPPORT
EQUIPMENT
PER
THE
MODEL
SPECIFICATIONS
.
SAVE THESE INSTRUCTIONS
S
AFETY
I
NSTRUCTIONS
6

C
ABINET
P
ANEL
W
ARNING
S
IGN
F
OR
YOUR
REFERRAL
AND
CONVENIENCE
,
A
WEATHER
RESISTANT
WARNING
SIGN
HAS
BEEN
MOUNTED
ON
THE
CABINET
SIDE
OF
YOUR
PORTABLE
SPA
. B
ECOME
FAMILIAR
WITH
THE
PRECAUTIONS
AND
EXERCISE
SAFETY
AND
CARE
WHILE
ENJOYING
YOUR
SPA
. T
HIS
SIGN
IS
PRINTED
IN
E
NGLISH
AND
F
RENCH
EXPOSED
,
THREE
ADDI-
TIONAL
LANGUAGES
ARE
ON
THE
REVERSE
SIDE
. S
HOULD
YOU
REQUIRE
,
EXPOSE
THE
REVERSE
SIDE
FOR
WARNING
IN
YOUR
NATIVE
LANGUAGE
.
E
NCLOSED
W
ARNING
S
IGN
FOR
P
OSTING
L
OCATE
THE
WEATHER
RESISTANT
SIGN
ENCLOSED
WITH
THIS
MANUAL
INTENDED
FOR
PERMANENT
POSTING
IN
AN
AREA
NEAR
THE
SPA
VISIBLE
TO
ALL
SPA
OCCU-
PANTS
. N
OTIFY
THE
FACTORY
OR
YOUR
RETAILER
SHOULD
YOU
REQUIRE
ADDITIONAL
SIGNS
OR
REPLACEMENTS
. E
NG-
LISH
AND
F
RENCH
VERSIONS
ARE
ON
ONE
SIDE
, S
PANISH
,
G
ERMAN
, I
TALIAN
ON
THE
REVERSE
. M
OUNT
WITH
YOUR
CHOSEN
LANGUAGE
FOR
EASY
VIEWING
.
WARNING:
R
EAD
ALL
INSTRUCTIONS
BEFORE
USING
THE
SPA
. S
MART
S
PAS
ASSUMES
NO
RESPONSIBIL-
ITY
FOR
PERSONAL
INJURY
OR
PROPERTY
DAMAGE
SUSTAINED
BY
OR
THROUGH
THE
USE
OF
THIS
PRODUCT
.
SAVE THIS MANUAL, SIGNS, AND INSTRUCTIONS FOR FUTURE REFERENCE.
A
S
PA
U
SE
L
ABELS
7
A

S
PA
P
ART
T
ERMINOLOGY
AND
D
ESCRIPTION
H
YDRO
-
JETS
: T
HESE
ARE
THE
WALL
FITTINGS
AROUND
THE
INSIDE
PERIMETER
OF
THE
SPA
. T
HEY
MIX
WATER
WITH
AIR
TO
PRODUCE
LOCALIZED
THERAPY
,
IN
A
STRAIGHT
STREAM
,
CIRCULAR
MOTION
OR
IN
RANDOM
PATTERNS
FOR
UPPER
AND
LOWER
BACK
MASSAGE
IN
THE
LOUNGE
AND
CONTOURED
SEATING
AREAS
.
S
UCTION
: T
HIS
IS
A
CIRCULAR
FITTING
MOUNTED
ON
THE
VERTICAL
WALL
OF
THE
FOOTWELL
AND
SERVES
THE
SAME
FUNCTION
AS
THE
SKIM
FILTER
. I
T
WORKS
IN
CONJUNCTION
WITH
THE
SKIM
FILTER
TO
RETURN
WATER
TO
THE
SUPPORT
EQUIPMENT
.
A
IR
C
ONTROLS
: T
HESE
ARE
ROUND
FITTINGS
MOUNTED
ON
THE
LIP
OF
SPA
THAT
CONTROL
THE
AMOUNT
OF
OUTSIDE
AIR
MIXED
WITH
THE
INCOMING
WATER
OF
THE
HYDRO
-
JET
. Y
OUR
SPA
HAS
MULTIPLE
AIR
CONTROLS
ON
THE
SPA
LIP
THAT
CONTROL
AIR
/
WATER
MIX
FOR
A
SEGMENT
OF
THE
JETS
.
S
PA
M
OOD
L
IGHT
: U
NDERWATER
LOW
VOLTAGE
LIGHT
WITH
ADDITIONAL
TWO
CHANGEABLE
COLORED
LENSES
FOR
NIGHT
TIME
SPA
ENJOYMENT
.
.
S
PA
P
ARTS
I
DENTIFICATION
8

S
PA
P
ART
T
ERMINOLOGY
AND
D
ESCRIPTION
P
UMP
:Y
OUR
NEW
SPA
IS
EQUIPPED
WITH
A
DUAL
SPEED
PUMP
FOR
FILTRATION
AND
HYDROTHERAPY
ACTION
. T
HE
CONTROL
CENTER
OPERATES
THIS
PUMP
. T
O
TURN
THE
PUMP
ON
,
PUSH
THE
PUMP
ONE
BUTTON
ON
THE
SPA
SIDE
CONTROL
,
LOCATED
ON
THE
TOP
OF
THE
SPA
. I
F
THE
SPA
IS
NOT
IN
A
FILTRATION
MODE
OR
CALLING
FOR
HEAT
,
PUSHING
THE
BUTTON
ONCE
WILL
TURN
THE
PUMP
ON
LOW
SPEED
,
PUSHING
IT
A
SECOND
TIME
WILL
ENGAGE
HIGH
SPEED
. A
THIRD
PUSH
OF
THE
BUTTON
WILL
TURN
THE
PUMP
OFF
. I
F
THE
SPA
IS
IN
A
FILTRATION
CYCLE
OR
CALLING
FOR
HEAT
,
THE
PUMP
WILL
ALREADY
BE
RUNNING
ON
LOW
SPEED
. P
USH
THE
BUTTON
ONCE
TO
TURN
THE
PUMP
ON
HIGH
,
AND
ONCE
AGAIN
TO
GO
BACK
TO
LOW
. T
HE
CONTROL
CENTER
WILL
TURN
THE
PUMP
OFF
WHEN
THE
SPA
REACHES
ITS
PRESET
TEMPERATURE
,
OR
THE
FILTRATION
CYCLE
ENDS
.
F
ILTER
: Y
OUR
S
MART
SPA
IS
EQUIPPED
WITH
A
SKIM
FILTER
. T
HIS
ASSURES
OPTIMUM
WATER
FILTERING
AND
EASE
OF
CLEANING
AT
SPA
SIDE
. R
EVIEW
THE
MAINTENANCE
SECTION
OF
THIS
MANUAL
FOR
FILTER
CARTRIDGE
CLEANING
AND
REPLACEMENT
.
.
H
EATER
: Y
OUR
SPA
IS
EQUIPPED
WITH
THERMOSTAT
CONTROL
AT
SPA
SIDE
. O
NCE
YOU
FIND
THE
TEMPERATURE
YOU
ENJOY
MOST
,
LEAVE
THE
THERMOSTAT
AT
THAT
SETTING
,
AND
THE
SPA
WILL
AUTOMATICALLY
MAINTAIN
THE
CORRECT
TEMPERATURE
;
READY
FOR
YOUR
ENJOYMENT
ANY
TIME
OF
THE
DAY
. A
VOID
CONSTANT
RESETTING
OF
THE
THERMOSTAT
;
IT
IS
MORE
ECONOMICAL
TO
MAINTAIN
TEMPERATURE
,
THAN
TO
LET
THE
TEMPERATURE
FALL
AND
THEN
WAIT
DURING
HEAT
-
UP
TIME
BEFORE
SOAKING
.
O
ZONE
: A
LL
SPAS
WITH
OZONE
OPTION
FOR
SANITATION
SHOULD
CIRCULATE
16-24
HOURS
DAILY
.
U
SE
THE
PROGRAMMABLE
ELECTRONIC
CONTROL
CENTER
TO
PROGRAM
THIS
OPERATION
.
S
UPPORT
E
QUIPMENT
I
DENTIFICATION
9

10
S
PA
S
PECIFICATIONS
—O
RBIT
S
PA
M
ODEL
GENERAL rev. 2009 / 07
Seating Capacity 6
Shell Material Polyethylene
Dimensions (Domestic) 78” Round x 36” deep
Dimensions (Export) 198 cm.Round 91cm. deep
Water Capacity 340 Gallons, 1287 Liters
Dry Weight 300Lbs, 136Kg
Skirt Material PermaWood™
Water Flow 187 Gallons per Minute
WATER SYSTEM** (photo ref.)
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak(Continuous)
HP 1 4.0 (2.0) HP 4.0 (2.0) HP
Electronics
Electrical Can 6 Gecko XE Series GeckoXE Series
Voltage 240 240
Amperage 40 2x16 / 1x32
Heater
4.0 KW 4.0 KW
Operation System
Main Spa Side Control 7 Gecko 200 Control Gecko 200 Control
Secondary Spa Side Control 8 N/A N/A
Water Treatment System Ozone Ready
Filter 25 sq. ft.
Slide Valves 2
Mega Swirl Jet A 2
Large Euro Jet w/ Eyeball E 17
Mega’ssage Jet G 1
Multi’ssage Jet P 0
Ozone Jet O 1
Diverter Valves V 0
Safety Suction U 2
Mini Skimmer K 0
Air Control I 2
Spa Light L 1
Drain Valve 5 0
SPECIAL FEATURES
Spa Pillows
Waterfall Control Valve C
Waterfall Jet WF
Stainless Steel Jetting
Motion Glow™ Light
SoundWave™ SE Audio
Ozone Water Purification OZ
N/A
N/A
Optional
N/A
N/A
N/A
Standard
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
6, 1
7
I
I
E
E
E E
E
G
A
A
U
U
O
L

11
S
PA
S
PECIFICATIONS
—O
RBIT
F
LEX
S
PA
M
ODEL
GENERAL rev. 2009 / 07
WATER SYSTEM** (photo ref)
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP
Electronics
Electrical Can 6 Gecko XE Series GeckoXESeries
Voltage 120/240 240
Amperage 20/40 2x16 / 1x32
Heater
1.0 KW / 4.0 KW 4.0 KW
Operation System
Main Spa Side Control 7 Gecko 200 Series Gecko 200 Series
Secondary Spa Side Control 8 N/A N/A
Seating Capacity 6
Shell Material Polyethylene
Dimensions (Domestic) 78” Round x 36” deep
Dimensions (Export) 198 cm.Round 91cm. deep
Water Capacity 340 Gallons, 1287 Liters
Dry Weight 300Lbs, 136Kg
Skirt Material PermaWood™
Water Flow 140 Gallons per Minute
Water Treatment System Ozone Ready
Filter 25 sq. ft.
Slide Valves 2
Mega Swirl Jet A 1
Large Euro Jet w/ Eyeball E 11
Mega’ssage Jet G 1
Ozone Jet O 1
Multissage Jet P 0
Diverter Valves V 0
Safety Suction U 2
Mini Skimmer K 0
Air Control I 2
Spa Light L 1
Drain Valve 5 0
SPECIAL FEATURES
Spa Pillows N/A
Motion Glow™ Light N/A
Stainless Steel Jetting Optional
Waterfall Jet WF N/A
Waterfall Control Valve C N/A
SoundWave™ SE Audio N/A
Ozone Water Purification OZ Standard
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
1
7 6
I
O
U
L
I
U
E
E
E
E
E
A
G

12
S
PA
S
PECIFICATIONS
—Q
UADRA
S
PA
M
ODEL
WATER SYSTEM** (photo ref)
GENERAL rev. 2009 / 07
SPECIAL FEATURES
Seating Capacity 6
Shell Material Polyethylene
Dimensions (Domestic) 78” (6’6”) sq. x 36” (3’0”)
Dimensions (Export) 198 cm. sq. x 92 cm.
Water Capacity 350 Gallons, 1325 Liters
Dry Weight 365 Lbs, 166Kg
Skirt Material PermaWood™
Water Flow 187 Gallons Per Minute
Water Treatment System Ozone ready
Filter 25 sq. ft.
Slide Valves 2
Mega Swirl Jet A 3
Large Euro Jet w/ Eyeball E 18
Mega’ssage Jet G 3
Multi’ssage Jet P 0
Ozone Jet O 1
Diverter Valves V 0
Safety Suction U 2
Mini Skimmer K 0
Air Control I 2
Spa Light L 1
Drain Valve 5 0
Spa Pillows N/A
Motion Glow™ Light N/A
Stainless Steel Jetting Optional
Waterfall Jet WF N/A
Waterfall Control Valve N/A
SoundWave™ SE Audio N/A
Ozone Water Purification OZ Standard
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak (continuous) HP 1 4.0 (2.0) HP 4.0 (2.0) HP
Electronics
Electrical Can 6 Gecko XE Series GeckoXESeries
Voltage 240 240
Amperage 40 2x16 / 1x32
Heater
4.0 KW 4.0 KW
Operation System
Main Spa Side Control 7 Gecko 200 Series Gecko 200 Series
Secondary Spa Side Control 8 N/A N/A
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
1, 6
7
I I
E
E
E E
AG A
G
A
G
U UO
L

13
S
PA
S
PECIFICATIONS
—Q
UADRA
F
LEX
S
PA
M
ODEL
GENERAL rev. 2009 / 07
WATER SYSTEM** (photo ref.)
SPECIAL FEATURES
Seating Capacity 6
Shell Material Polyethylene
Dimensions (Domestic) 78.5” sq. x 33“
Dimensions (Export) 198 cm. sq. x 92 cm.
Water Capacity 350 Gallons, 1325 Liters
Dry Weight 365 Lbs, 166 Kg
Skirt Material PermaWood™
Water Flow 140 Gallons Per Minute
Water Treatment System Ozone ready
Filter 25 sq. ft.
Slide Valves 2
Mega Swirl Jet A 1
Large Euro Jet w/ Eyeball E 11
Mega’ssage Jet G 2
Multi’ssage Jet P 0
Ozone Jet O 1
Diverter Valves V 0
Safety Suction U 2
Mini Skimmer K 0
Air Control I 2
Spa Light L 1
Drain Valve 5 0
Spa Pillows N/A
Motion Glow™ Light N/A
Stainless Steel Jetting Optional
Waterfall Jet WF N/A
Waterfall Control Valve C N/A
SoundWave™ SE Audio N/A
Ozone Water Purification OZ Standard
ELECTRICAL SYSTEM
Pump Information Reference Number Domestic (60Hz) Export (50Hz)
Pump #1 peak(Continuous) HP 1 2.0 (1.0) HP 2.0 (1.0) HP
Electronics
Electrical Can 6 Gecko XE Series GeckoXESeries
Voltage 120/240 240
Amperage 20/40 2x16 / 1x32
Heater
1.0 KW/4.0 KW 4.0 KW
Operation System
Main Spa Side Control 7 Gecko 200 Series Gecko 200 Series
Secondary Spa Side Control 8 N/A N/A
** Not every jet is referenced. Each type of jet is noted for ease of identification. *Note location of audio components prior to install.
Equipment location relates to slimline design, AdvantagePack option has major components located beneath end cabinet.
All specifications are accurate at time of print. Manufacturer reserves the option to change product without prior notice.
Dimensions are approximate.
E
A
E
E
E
E
E
E
E
E
E
E G
G
U
U
O,L
I I
7
1, 6

I
NSTALLATION
G
UIDELINES
T
HE
LOCATION
OF
YOUR
SPA
IS
AN
IMPORTANT
F
ACTOR
IN
GUARANTEEING
YOUR
MAXIMUM
SPA
ENJOY-
MENT
. G
ENERALLY
,
MOST
SPAS
ARE
INSTALLED
OUTDOORS
WITH
NO
CONCERNS
REGARDING
MOISTURE
ACCUMULATION
,
WATER
SPILL
-
OVER
,
ETC
.
WHICH
ARE
CONSIDERATIONS
FOR
THOSE
LOCATED
INSIDE
.
O
UTDOOR
I
NSTALLATION
C
ONSIDERATIONS
1. L
OCAL
ELECTRICAL
AND
PLUMBING
CODES
.
2. C
ONSIDER
LOCAL
CODES
PERTAINING
TO
FENCING
,
ENCLOSURES
,
WALLS
,
ELECTRICAL
AND
PLUMBING
.
Y
OU
WILL
NEED
TO
ENSURE
THAT
YOUR
SPA
IS
AN
ADEQUATE
DISTANCE
FROM
POWER
LINES
,
BOTH
ABOVE
GROUND
AND
UNDERGROUND
. Y
OUR
SPA
WILL
ALSO
NEED
TO
BE
CHILDPROOFED
.
3. V
IEW
FROM
HOUSE
FOR
AESTHETICS
AND
SUPERVISORY
NEEDS
.
4. D
ISTANCE
FROM
HOUSE
FOR
WINTERTIME
SOAKING
.
5. N
IGHTTIME
LIGHTING
.
6. L
OCATE
THE
SPA
WITH
AN
AWARENESS
TO
SUNLIGHT
EXPOSURE
,
VIEWS
,
ACCESS
,
PROPERTY
LINES
,
LIGHTING
,
WIND
DIRECTION
,
SHIELDING
,
SEPTIC
TANKS
,
PLANTS
,
TREES
. (C
HEMICALS
IN
THE
SPA
WATER
SPLASHED
FROM
YOUR
SPA
MAY
DAMAGE
NEARBY
PLANT
LIFE
.)
7. C
ONSIDER
THE
LOCATION
OF
THE
NEAREST
BATHROOM
.
8. I
F
YOUR
SPA
IS
TO
BE
LOCATED
ON
A
SECOND
STORY
,
BE
POSITIVE
SUPPORT
IS
ADEQUATE
.
C
ALL
YOUR
BUILDER
.
9. A
REA
FOR
PLACEMENT
OF
SUPPORT
EQUIPMENT
WHERE
ADEQUATE
SPACE
WILL
BE
NEEDED
TO
GAIN
ACCESS
TO
COMPONENTS
FOR
MAINTENANCE
AND
GENERAL
SERVICING
.
10. B
E
SURE
TO
NOTE
ANY
OTHER
CONSIDERATIONS
,
SUCH
AS
AESTHETICS
OR
PRIVACY
CONCERNS
,
THAT
MAY
AFFECT
THE
SAFETY
OR
ENJOYMENT
OF
USING
THE
SPA
.
11. P
ROVIDE
ADEQUATE
DRAINAGE
AWAY
FROM
THE
EQUIPMENT
AND
ADEQUATE
ELEVATION
TO
ALLOW
DRAINING
BY
SIPHON
,
IF
SHOULD
BE
REQUIRED
.
12. L
OCATION
OF
ELECTRICAL
SUPPLY
. 120/240
VOLT
SYSTEMS
REQUIRE
HARD
WIRE
INSTALLED
FROM
THE
ELECTRICAL
SOURCE
TO
THE
SPA
SUPPORT
PACK
TERMINAL
. ALL EQUIPMENT MUST
BE GROUND FAULT CIRCUIT PROTECTED AT THE POWER SOURCE.
ALL ELECTRICAL WIRING OF THE SPA SUPPORT EQUIPMENT MUST COMPLY
WITH THE NATIONAL ELECTRIC CODE.
13. L
OCATIONS
AT
LEAST
5
FT
(1.52
M
)
FROM
ALL
METAL
SURFACES
. (A
SPA
MAY
BE
INSTALLED
WITHIN
5
FEET
OF
METALS
SURFACES
PROVIDING
EACH
METAL
SURFACE
IS
PERMANENTLY
CONNECTED
BY
A
N
O
. 8AWG (8.4
MM
2)
COPPER
CONDUCTOR
ATTACHED
TO
THE
WIRE
CONNECTOR
ON
THE
TERMINAL
BOX
PROVIDED
FOR
THIS
PURPOSE
.) ALL INSTALLATIONS
MUST COMPLY WITH ARTICLE 680 OF THE U.S. NATIONAL ELECTRIC CODE AND
ANSI/NFPA 70-1984.
14. P
LACE
THE
SPA
ON
A
FIRM
,
LEVEL
SURFACE
THAT
WILL
NOT
SHIFT
.
S
PA
I
NSTALLATION
14

I
NSTALLATION
G
UIDELINES
I
NDOOR
I
NSTALLATION
C
ONSIDERATIONS
1. L
OCAL
ELECTRICAL
AND
PLUMBING
CODES
.
2. V
ENTILATION
FANS
AND
/
OR
DEHUMIDIFIERS
SHOULD
BE
PROVIDED
TO
HANDLE
THE
HIGH
HUMIDITY
DEVELOPED
BY
YOUR
SPA
. W
ALLS
,
CEILING
AND
WOOD
TRIM
SHOULD
BE
RESISTANT
,
ALSO
.
3. C
HEMICALS
WILL
VAPORIZE
FROM
THE
WATER
AND
MAY
CAUSE
AN
ODOR
AND
POSSIBLY
CORROSION
TO
CERTAIN
HOME
HARD
-
WARE
. N
EVER
STORE
CHEMICALS
INSIDE
THE
SPA
CABINET
.
4. D
URING
THE
NORMAL
USE
OF
THE
SPA
,
WATER
WILL
ESCAPE
THE
SPA
VESSEL
. N
EVER
PLACE
THE
SPA
ON
OR
OVER
ANY
MATERIAL
WHICH
MAY
BE
DAMAGED
BY
THIS
WATER
OR
THE
CHEMICALS
WITHIN
THE
WATER
. K
EEP
DAMAGEABLE
MATERIALS
FAR
ENOUGH
AWAY
FROM
THE
SPA
TO
AVOID
WATER
DAMAGE
,
EVEN
IF
THE
SPA
SHOULD
LOSE
ALL
ITS
WATER
.
5. C
ONSIDER
AND
PREPARE
FOR
THE
UNLIKELY
EVENT
OF
RAPID
SPA
DRAINAGE
. I
F
PLACEMENT
OF
THE
SPA
IS
PERMANENT
,
YOU
MAY
WISH
TO
PROVIDE
FLOOR
DRAINS
TO
ACCOMMODATE
DRAINING
,
ETC
. A
LWAYS
LEAVE
ROOM
ALL
AROUND
THE
SPA
FOR
EASY
ACCESS
IN
CASE
REPAIRS
ARE
NECESSARY
.
6. C
ONSIDER
AND
PREPARE
FOR
THE
UNLIKELY
EVENT
OF
SPA
REMOVAL
.
7. R
EAD
7-14
IN
THE
O
UTDOOR
I
NSTALLATIONS
INFORMATION
.
8. D
O
NOT
SET
SPA
ON
FINISHED
FLOOR
WITHOUT
A
WATERPROOF
BARRIER
PROTECTION
UNDERNEATH
.
9. T
HE
SPA
SHOULD
HAVE
ACCESS
TO
A
POWER
SOURCE
CAPABLE
OF
SUPPLYING
240
VOLTS
AC
POWER
.
I
T
MUST
BE
WIRED
DIRECTLY
INTO
A
GROUNDED
CIRCUIT
WITH
A
G
ROUND
F
AULT
C
IRCUIT
I
NTERRUPTER
(G.F.C.I.)
OR
EQUIVALENT
RCD,
FOR
EXPORT
INSTALLS
. N
O
OTHER
APPLIANCES
SHOULD
BE
ON
THE
SAME
CIRCUIT
.
10. T
HE
SPA
SHOULD
BE
CLOSE
TO
A
SOURCE
OF
WATER
.
11. B
E
SURE
THAT
THE
LOCATION
YOU
CHOOSE
IS
STABLE
. I
T
MUST
BE
ABLE
TO
SUPPORT
THE
WEIGHT
OF
THE
SPA
WHEN
IT
IS
FILLED
WITH
WATER
,
PLUS
THE
WEIGHT
OF
THE
OCCUPANTS
. T
HE
SPA
MAY
WEIGH
UP
TO
6000
LBS
( 2722
KG
.)
WHEN
IT
IS
FILLED
WITH
WATER
.
12. D
O
NOT
USE
THE
SPA
ABOVE
A
FINISHED
LIVING
AREA
,
DUE
TO
THE
RISK
OF
WATER
DAMAGE
.
13. T
HE
SPA
IS
NOT
DESIGNED
FOR
IN
-
FLOOR
INSTALLATION
. H
OWEVER
,
IT
IS
COMPATIBLE
WITH
A
DECK
SYSTEM
THAT
IS
BUILT
FLUSH
WITH
THE
TOP
OF
THE
SPA
,
PROVIDED
YOU
LEAVE
ACCESS
FOR
SERVICE
.
14. B
E
SURE
TO
NOTE
ANY
OTHER
CONSIDERATIONS
,
SUCH
AS
AESTHETICS
OR
PRIVACY
CONCERNS
,
THAT
MAY
AFFECT
THE
SAFETY
OR
ENJOYMENT
OF
USING
THE
SPA
.
WARNING:
THIS IS A PROFESSIONAL GRADE PRODUCT.
A KNOWLEDGE OF CONSTRUCTION TECHNIQUES, PLUMBING AND ELECTRICAL
INSTALLATION ACCORDING TO CODES ARE REQUIRED FOR PROPER INSTALLATION
AND USER SATISFACTION. WE RECOMMEND THAT A LICENSED CONTRACTOR
PERFORM THE INSTALLATION. OUR WARRANTY DOES NOT COVER
IMPROPER INSTALLATION-RELATED PROBLEMS.
S
PA
I
NSTALLATION
15

G
ENERAL
L
OCATION
C
ONSIDERATIONS
R
EVIEW
OUTDOOR
INSTALLATIONS
AND
INDOOR
INSTALLATIONS
PRIOR
TO
CHOOSING
YOUR
SPA
LOCATION
. Y
OUR
SPA
SHOULD
BE
PLACED
ON
A
LEVEL
CONCRETE
PAD
OR
ON
A
DECK
DESIGNED
TO
SUPPORT
6000
LBS
(2722
KG
.)
OR
ON
PATIO
BLOCKS
ON
THE
GROUND
. D
O
NOT
PLACE
THE
SPA
ON
A
DIRT
SURFACE
OR
DIRECTLY
ON
THE
GROUND
. O
NCE
YOU
HAVE
A
LOCATION
SELECTED
,
THERE
ARE
SEVERAL
ISSUES
YOU
SHOULD
CONSIDER
IN
PREPARING
THE
SITE
FOR
THE
HOT
TUB
INSTALLATION
.
A
FLAT
,
LEVEL
SURFACE
THAT
IS
STRONG
ENOUGH
TO
SUPPORT
YOUR
SPA
IS
REQUIRED
. O
NCE
YOUR
SPA
IS
FILLED
,
IT
HAS
CONSIDERABLE
WEIGHT
. M
AKE
CERTAIN
THE
LOCATION
YOU
CHOOSE
CAN
SUPPORT
A
MINIMUM
OF
100
LBS
(45.4
KG
)
PER
SQUARE
FOOT
LOAD
,
PER
RECOMMENDED
GUIDELINES
. S
TRUCTURAL
DAMAGE
TO
THE
SPA
RESULTING
FROM
THE
INCORRECT
INSTALLATION
OF
PLACEMENT
ON
INADEQUATE
FOUNDATION
IS
NOT
COV-
ERED
IN
THE
SPA
’
S
LIMITED
WARRANTY
.
M
OST
UNITS
ARE
INSTALLED
OUTSIDE
,
ON
GROUND
LEVEL
,
ON
EITHER
A
CONCRETE
PAD
OR
A
WOODEN
DECK
. I
F
THE
SPA
IS
NOT
ON
GROUND
LEVEL
,
HAVE
A
BUILDER
DETERMINE
IF
THE
SUPPORT
IS
ADEQUATE
. I
F
THE
UNIT
IS
PLACED
DIRECTLY
ON
THE
GROUND
,
YOU
WILL
WANT
TO
REMOVE
THE
GRASSY
LEVEL
,
AND
PLACE
A
LAYER
OF
GRAVEL
ON
THE
SOIL
. T
HE
BEST
WAY
TO
LEVEL
THE
GRAVEL
MAY
BE
WITH
THE
STRAIGHT
EDGE
OF
A
PIECE
OF
SOLID
LUMBER
TO
ACHIEVE
A
LEVEL
SURFACE
. P
AVERS
PLACED
IN
A
SAND
BASE
IS
ALSO
A
RATHER
QUICK
AND
CONVENIENT
WAY
TO
PREPARE
THE
LOCATION
SITE
. N
OTE
THAT
PAVERS
,
STEPPING
STONES
,
ETC
.
STILL
HAVE
A
TENDENCY
TO
SETTLE
AND
MAY
BECOME
UNLEVEL
AT
SOME
POINT
. A
REINFORCED
CONCRETE
SLAB
SHOULD
BE
AT
LEAST
FOUR
INCHES
THICK
WITH
THE
REINFORCING
MESH
OR
ROD
ATTACHED
TO
A
BOND
WIRE
.
M
AKE
SURE
YOUR
DIMENSIONS
ARE
CORRECT
AS
YOU
PREPARE
THE
SITE
FOR
YOUR
NEW
HOT
TUB
. C
LICK
ONTO
THE
WEB
SITE
OR
CALL
YOUR
RETAILER
FOR
DIMENSIONS
OF
THE
MODEL
YOU
HAVE
CHOSEN
. A
LLOW
A
PERIMETER
OF
THE
CHOSEN
GROUND
SURFACE
TO
EXTEND
BEYOND
THE
SPA
ITSELF
TO
PROVIDE
A
CLEAN
AREA
FOR
USERS
TO
GET
IN
AND
OUT
OF
THE
SPA
.
T
HE
SPA
LOCATION
AND
THE
SPA
ITSELF
MUST
BE
LEVEL
BEFORE
FILLING
WITH
WATER
.
S
HOULD
YOUR
SPA
SITE
BE
A
WOODEN
DECK
,
THIS
PROVIDES
A
CLEAN
AREA
WITH
WEATHER
AND
ROT
RESISTANT
QUALITIES
,
IF
A
PRESSURE
-
TREATED
TYPE
LUMBER
IS
USED
. C
ONSIDER
THE
LOAD
REQUIREMENTS
AND
CONSULT
A
BUILDER
TO
DETERMINE
IF
YOUR
DECK
IS
OF
ADEQUATE
STRENGTH
.
I
F
INSTALLING
YOUR
HOT
TUB
BELOW
GRADE
,
CONSIDER
ADEQUATE
DRAINAGE
FOR
RUN
-
OFF
AND
THE
UNLIKELY
EVENT
OF
RAPID
SPA
DRAINAGE
.
A
LLOW
ADEQUATE
SPACE
TO
ACCESS
THE
EQUIPMENT
BEHIND
THE
FOUR
ACCESS
PANELS
ON
THE
HOT
TUB
CABINET
. R
EVIEW
THE
PAGES
IN
THIS
MANUAL
REFERENCING
SPA
MODEL
SPECIFICATIONS
FOR
THE
LOCATION
OF
THE
SUPPORT
EQUIPMENT
FOR
THE
MODEL
YOU
HAVE
CHOSEN
.
L
EAVE
AMPLE
ACCESS
TO
THE
GFCI
CIRCUIT
BREAKER
FOR
TESTING
,
ETC
.
A
QUICK
DISCONNECT
(
MANUAL
DISCONNECT
)
IS
TO
BE
INSTALLED
BETWEEN
5 - 15
FT
(1.5-4.6
M
)
OF
THE
SPA
AND
WITHIN
THE
LINE
OF
SIGHT
FROM
THE
HOT
TUB
. C
ONSIDER
WHERE
THIS
CAN
BE
LOCATED
WHEN
SELECT-
ING
AND
PREPARING
THE
SPA
SITE
. A
LL
WIRING
MUST
COMPLY
WITH
THE
U.S. N
ATIONAL
E
LECTRIC
C
ODE
.
A
CABINET
SIDE
DRAIN
HAS
BEEN
INSTALLED
ON
THE
BOTTOM
PORTION
OF
A
CABINET
SIDEWALL
FOR
EASY
DRAINING
. L
OCATE
THIS
DRAIN
AND
LEAVE
AMPLE
ACCESS
. Y
OUR
SPA
MAY
HAVE
BEEN
CHOSEN
WITH
THE
A
DVANTAGE
P
ACK
DESIGN
;
WITH
THIS
FEATURE
,
ALL
THE
EQUIPMENT
IS
LOCATED
BENEATH
AN
END
CABINET
.
A
LLOW
EASY
ACCESS
TO
ALL
COMPONENTS
. T
HIS
DESIGN
ALSO
FEATURES
A
SIDE
DRAIN
FOR
EMPTYING
.
S
PA
I
NSTALLATION
16
This manual suits for next models
3
Table of contents
Popular Hot Tub manuals by other brands

Viking spas
Viking spas Viking 1P user manual

Aqua Pulse Spas
Aqua Pulse Spas AVALON DELUXE PLATINUM SPA user manual

Invacare
Invacare 3750 Maintenance instructions

DURAVIT
DURAVIT Air-System operating instructions

QCA Spa
QCA Spa VS501 PAK (VL260 TOPSIDE) owner's manual

Strong Pools and Spas
Strong Pools and Spas Patriot Spa owner's manual