Snell & Wilcox NRS70TX User manual

NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 0.1
Operator’s
Manual
© August 2003
www.snellwilcox.com
Snell & Wilcox Ltd., Southleigh Park House, Eastleigh Road, Havant, Hants, PO9 2PE, United Kingdom.
For General Enquiry’s contact: Tel: +44 (0) 2392 489000 Fax: +44 (0)23 9245 1411
For Technical assistance contact: Tel: +44 (0) 2392 489058 Fax: +44 (0) 2392 489057
Web: http://www.snellwilcox.com/support Ftp: ftp://ftp.snellwilcox.com/support
NRS70 and NRS70TX
Digital Noise Reducer & Frame Synchronizer

NRS70 Series SECTION 0
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 0.2
Explanation of Safety Symbols
This symbol refers the user to important information contained in
the accompanying literature. Refer to manual.
This symbol indicates that hazardous voltages are present inside.
No user serviceable parts inside.
This unit should only be serviced by trained personnel.
Servicing instructions where given, are for use by
qualified service personnel only.
To reduce risk of electric shock do not perform any
servicing other than that contained in the operating
instructions unless you are qualified to do so.
Refer all servicing to qualified personnel.
To reduce the risk of electric shock, do not expose this appliance
to rain or moisture.
Always ensure that the unit is properly earthed and power connections
correctly made.
This equipment must be supplied from a power system providing a
PROTECTIVE EARTH connection and having a neutral connection
which can be reliably identified.
The power outlet supplying power to the unit should be close to the
unit and easily accessible
Power connection in countries other than the USA
The equipment is normally shipped with a power cable with a standard IEC
moulded free socket on one end and a standard IEC moulded plug on the other.
If you are required to remove the moulded mains supply plug, dispose of the
plug immediately in a safe manner.
The colour code for the lead is as follows:
GREEN/YELLOW lead connected to E
(Protective Earth Conductor)
BLUE lead connected to N (Neutral Conductor)
BROWN lead connected to L (Live Conductor)
Caution If the unit has two mains supply inputs ensure that both power
cords are plugged into mains outlets operating from the same phase.
L N
E
N L
E
GB
!
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVERS
NO USER SERVICEABLE PARTS
REFER SERVICING TO QUALIFIED
PERSONNEL ONLY
!
!
Safety Warnings
Légende :
Ce symbole indique qu'il faut prêter attention et se référer
au manuel.
Ce symbole indique qu'il peut y avoir des tensions électriques
à l'intérieur de l'appareil. Ne pas intervenir sans l'agrément
du service qualifié.
Pour réduire le risque de choc électrique, ne pas exposer l'appareil
dans un milieu humide.
Toujours s'assurer que l'unité est correctement alimentée,
en particuliers à la liaison à la terre.
La source électrique de cet équipement doit posséder une connexion
à la terre , ainsi qu'une liaison « neutre » identifiable.
La prise électrique qui alimente l'appareil doit être proche
de celle-ci et accessible.
Câble secteur de pays autres que les Etats-Unis
L'équipement est livré avec un câble secteur au standard IEC, moulé
mâle/femelle.
Si vous souhaitez changr la prise mâle de votre cordon, voici les
codes couleurs des fils :
Le fil VERT/JAUNE est connecté à T (Terre)
Le fil BLEU est connecté à N (Neutre)
Le fil MARRON est connecté à P (Phase)
Attention si l'appareil a 2 alimentations, s'assurer que les cordons
soient branchés sur la même phase.
Précaution d'emploi :
F
Les procédures de maintenance ne concernent
que le service agréé. Afin de réduire le risque de
choc électrique, il est recommandé de se limiter
aux procédures d'utilisation, à moins d'en être qualifié.
Pour toute maintenance, contacter le service compétent.
!
ATTENTION
RISQUE DE CHOC ELECTRIQUE
NE PAS RETIRER LE COUVERCLE
NE PAS INTERVENIR SANS
L'AGREMENT DU SERVICE
QUALIFIE
P N
T
N P
T
Connecteur Prise
!
!
Erklärung der Sicherheitssymbole
Dieses Symbol weist den Benutzer auf wichtige Informationen
hin, die in der begleitenden Dokumentation enthalten sind.
Dieses Symbol zeigt an, dass gefährliche Spannung vorhanden ist.
Es befinden sich keine vom Benutzer zu wartenden Teile im Geräteinneren.
Dieses Gerät sollte nur von geschultem Personal gewartet werden
Um das Risiko eines Elektroschocks zu reduzieren, setzen Sie das
Gerät weder Regen noch Feuchtigkeit aus.
Stellen Sie immer sicher, dass das Gerät ordnungsgemäß geerdet
und verkabelt ist.
Dieses Equipment muss an eine Netzsteckdose mit Schutzleiter
angeschlossen werden und einen zuverlässig identifizierbaren Nullleiter haben.
Die Netzsteckdose sollte nahe beim Gerät und einfach zugänglich sein.
Netzanschluss in anderen Ländern als der USA
Das Equipment wird im Normalfall mit einem Netzkabel mit Standard IEC
Anschlussbuchse und einem Standard IEC Anschlussstecker geliefert.
Sollten Sie den angeschweißten Stecker auswechseln müssen, entsorgen
Sie diesen bitte umgehend. Die farbliche Belegung des Netzkabels ist wie folgt:
GRÜN GELB E = Schutzleiter
BLAU N = Nulleiter
BRAUN L = P = Phase
Achtung: Wenn das Gerät zwei Anschlussbuchsen hat, stellen
Sie bitte sicher, dass beide Netzkabel mit der selben Phase in die
Netzsteckdose gesteckt werden.
Sicherheits-Warnhinweise
D
!
!
Die angeführten Service-/Reparatur-Anweisungen sind
ausschließlich von qualifiziertem Service-Personal
auszuführen. Um das Risiko eines lektroschocks zu
reduzieren, führen Sie ausschließlich die im
Benutzerhandbuch eschriebenen Anweisungen aus,
es sei denn, Sie haben die entsprechende Qualifikation.
Wenden Sie sich in allen Service-Fragen an qualifiziertes Personal.
!
ACHTUNG
Gefahr von Elektroschocks.
Abdeckungen nicht entfernen
Keine vom Benutzer zu wartende Teile
Wenden Sie sich ausschließlich
an qualifiziertes Personal
L =
Phase N =
Nulleiter N =
Nulleiter L =
Phase
E =
Schutzleiter
E =
Schutzleiter
Explicación de los Símbolos de Seguridad
Éste símbolo refiere al usuario información importante contenida
en la literatura incluida. Referirse al manual.
Éste símbolo indica que voltajes peligrosos están presentes en el interior.
No hay elementos accesibles al usuario dentro.
Esta unidad sólo debería ser tratada por personal cualificado.
Las instrucciones de servicio cuando sean dadas, son
sólo para uso de personal cualificado. Para reducir el
riesgo de choque eléctrico no llevar a cabo ninguna
operación de servicio aparte de las contenidas en las
instrucciones de operación, a menos que se esté
cualificado para realizarlas.
Referir todo el trabajo de servicio a personal cualificado.
Para reducir el riesgo de choque eléctrico, no exponer este equipo
a la lluvia o humedad.
Siempre asegurarse de que la unidad está propiamente conectada a
tierra y que las conexiones de alimentación están hechas correctamente.
Este equipo debe ser alimentado desde un sistema de alimentación
con conexión a TIERRA y teniendo una conexión neutra fácilmente
identificable.
La toma de alimentación para la unidad debe ser cercana y fácilmente
accesible.
Conexión de alimentación en otros países que no sean USA
El equipo es normalmente entregado con un cable de alimentación con un
enchufe hembra estándar IEC en un extremo y con una clavija estándar
IEC en el otro. Si se requiere eliminar la clavija para sustituirla por otra,
disponer dicha clavija de una forma segura.
El código de color a emplear es como sigue:
Advertencia Si la unidad tuviera dos tomas de alimentación, asegurarse
de que ambos cables de alimentación están conectados a la misma fase.
ESP
!
!
Advertencias de Seguridad
L N
E
N L
E
Clavija
Aerea Macho Enchufe
Aereo Hembra
VERDE/ AMARILLO conectado a E
(Conductor de protección a Tierra
-Earth en el original-)
AZUL conectado a N (Conductor Neutro -Neutral en el original-)
MARRÓN conectado a L (Conductor Fase -Live en el original-)
RIESGO DE CHOQUE ELECTRICO
NO QUITAR LAS PROTECCIONNES
ELEMENTOS NO ACCESIBLES AL
USUARIO.
SERVICIO SOLAMENTE A PERSONAL
CUALIFICADO

NRS70 Series SECTION 0
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 0.3
Simboli di sicurezza:
Questo simbolo indica l'informazione importante contenuta nei
manuali appartenenti all'apparecchiatura. Consultare il manuale.
Questo simbolo indica che all'interno dell'apparato sono presenti
tensioni pericolose. Non cercare di smontare l'unità.
Per qualsiasi tipo di intervento rivolgersi al personale qualificato.
Le istruzioni relative alla manutenzione sono ad uso
esclusivo del personale qualificato. E' proibito all'utente
eseguire qualsiasi operazione non esplicitamente
consentita nelle istruzioni. Per qualsiasi informazione
rivolgersi al personale qualificato.
Per prevenire il pericolo di scosse elettriche è necessario non esporre
mai l'apparecchiatura alla pioggia o a qualsiasi tipo di umidità.
Assicurarsi sempre, che l'unità sia propriamente messa a terra e che
le connessioni elettriche siano eseguite correttamente.
Questo dispositivo deve essere collegato ad un impianto elettrico
dotato di un sistema di messa a terra efficace.
La presa di corrente deve essere vicina all'apparecchio
e facilmente accessibile.
Connessione elettrica nei paesi diversi dagli Stati Uniti
L'apparecchiatura normalmente è spedita con cavo pressofuso con la presa
e spina standard IEC. Nel caso della rimozione della spina elettrica,
gettarla via immediatamente osservando tutte le precauzioni del caso.
La leggenda dei cavi è la seguente:
VERDE/GIALLO cavo connesso
ad "E" (terra)
BLU cavo connesso ad "N" (neutro)
MARRONE cavo connesso ad "L" ( fase)
Attenzione! Nel caso in cui l'apparecchio abbia due prese di corrente,
assicurarsi che i cavi non siano collegati a fasi diverse della rete elettrica.
I
!
!
Attenzione:
!
ATTENZIONE
L N
E
N L
E
Presa volante Spina volante
RISCHIO DI SHOCK ELETTRICO
NON CERCARE DI SMONTARE
L'UNITA PER QUALSIASI TIPO DI
INTERVENTO RIVOLGERSI AL
PERSONALE QUALIFICATO
Förklaring av Säkerhetssymboler
Denna symbol hänvisar användaren till viktig information som
återfinns i litteraturen som medföljer. Se manualen.
Denna symbol indikerar att livsfarlig spänning finns på insidan.
Det finns inga servicevänliga delar inne i apparaten.
Denna apparat få endast repareras av utbildad personal.
Serviceinstruktioner som anges avser endast kvalificerad
och utbildad servicepersonal. För att minska risken för
elektrisk stöt, utför ingen annan service än den som
återfinns i medföljande driftinstruktionerna, om du ej är
behörig. Överlåt all service till kvalificerad personal.
För att reducera risken för elektrisk stöt, utsätt inte apparaten för
regn eller fukt.
Se alltid till att apparaten är ordentligt jordad samt att strömtillförseln
är korrekt utförd.
Denna apparat måste bli försörjd från ett strömsystem som är försedd
med jordadanslutning samt ha en neutral anslutning som lätt identifierbar.
Vägguttaget som strömförsörjer apparaten bör finnas i närheten samt
vara lätttillgänglig.
Strömkontakter i länder utanför USA
Apparaten utrustas normalt med en strömkabel med standard IEC gjuten
honkontakt på ena änden samt en standard IEC gjuten hankontakt på den
andra änden. Om man måste avlägsna den gjutna hankontkaten, avyttra
denna kontakt omedelbart på ett säkert sätt. Färgkoden för ledningen är följande:
GRÖN/GUL ledning ansluten till E
(Skyddsjordad ledare)
BLÅ ledning ansluten till N (Neutral ledare)
BRUN ledning ansluten till L (Fas ledare)
Varning! Om enheten har två huvudsakliga elförsörjningar, säkerställ att
båda strömkablarna som är inkopplade i enheten arbetar från samma fas.
S
!
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVERS
NO USER SERVICEABLE PARTS
REFER SERVICING TO QUALIFIED
PERSONNEL ONLY
!
!
Säkerhetsvarningar
L N
E
N L
E
Stickkontakt-Hane Stickkontakt-Hona
Forklaring på sikkerhedssymboler
Dette symbol gør brugeren opmærksom på vigtig information
i den medfølgende manual.
Dette symbol indikerer farlig spænding inden i apparatet. Ingen bruger
servicerbare dele i apparatet på brugerniveau.
Dette apparat må kun serviceres af faglærte personer..
Serviceinstruktioner er kun til brug for faglærte
servicefolk. For at reducere risikoen for elektrisk
stød må bruger kun udføre anvisninger i
betjeningsmanualen.
Al service skal udføres af faglærte personer.
For at reducere risikoen for elektrisk stød må apparatet ikke
udsættes for regn eller fugt.
Sørg altid for at apparatet er korrekt tilsluttet og jordet.
Dette apparat skal forbindes til en nettilslutning, der yder
BESKYTTENDE JORD og 0 forbindelse skal være tydeligt markeret.
Stikkontakten, som forsyner apparatet, skal være tæt på apparatet
og let tilgængelig
.
Nettilslutning i andre lande end USA
Udstyret leveres normalt med et strømkabel med et standard IEC støbt løst
hunstik i den ene ende og et standard IEC støbt hanstik i den anden ende.
Hvis et af de støbte stik på strømkablet er defekt, skal det straks kasseres på
forsvarlig vis. Farvekoden for lederen er som følger:
GRØN/GUL leder forbundet til J (Jord)
BLÅ leder forbundet til 0
BRUN leder forbundet til F(Fase)
Forsigtig Hvis enheden har to lysnetindgange, skal der sørges for at
begge ledninger tilsluttes lystnetudgange fra den samme fase.
DK
!
!
!
Sikkerhedsadvarsler
!
FORSIGTIG
RISIKO FOR ELEKTRISK STØD
DÆKPLADER MÅ IKKE FJERNES
INGEN BRUGER SERVICERBARE
DELE SERVICE MÅ KUN UDFØRES
AF FAGLÆRTE PERSONER
F 0
J
0 F
J
Han-stik Hun-stik
Turvamerkkien selitys
Tämä merkki tarkoittaa, että laitteen mukana toimitettu kirjallinen
materiaali sisältää tärkeitä tietoja. Lue käyttöohje.
Tämä merkki ilmoittaa, että laitteen sisällä on vaarallisen voimakas jännite.
Sisäpuolella ei ole mitään osia, joita käyttäjä voisi itse huoltaa.
Huollon saa suorittaa vain alan ammattilainen.
Huolto-ohjeet on tarkoitettu ainoastaan alan
ammattilaisille. Älä suorita laitteelle muita
toimenpiteitä, kuin mitä käyttöohjeissa on
neuvottu, ellet ole asiantuntija. Voit saada sähköiskun.
Jätä kaikki huoltotoimet ammattilaiselle.
Sähköiskujen välttämiseksi suojaa laite sateelta ja kosteudelta.
Varmistu, että laite on asianmukaisesti maadoitettu ja että
sähkökytkennät on tehty oikein.
Laitteelle tehoa syöttävässä järjestelmässä tulee olla
SUOJAMAALIITÄNTÄ ja nollaliitännän on oltava luotettavasti
tunnistettavissa.
Sähköpistorasian tulee olla laitteen lähellä ja helposti tavoitettavissa.
Sähkökytkentä
Laitteen vakiovarusteena on sähköjohto, jonka toisessa päässä on muottiin
valettu, IEC-standardin mukainen liitäntärasia ja toisessa päässä muottiin
valettu, IEC-standardin mukainen pistoliitin. Jos pistoliitin tarvitsee poistaa,
se tulee hävittää heti turvallisella tavalla. Johtimet kytketään seuraavasti:
KELTA-VIHREÄ suojamaajohdin E-napaan
SININEN nollajohdin N-napaan
RUSKEA vaihejohdin L-napaan
Huom! Jos laitteessa on kaksi verkkojännitteen tuloliitäntää, niiden johdot
on liitettävä verkkopistorasioihin, joissa on sama vaiheistus.
FI
!
!
Turvaohjeita
!
SÄHKÖISKUN VAARA ÄLÄ AVAA
LAITTEEN KANSIA EI SISÄLLÄ
KÄYTTÄJÄLLE HUOLLETTAVIA
OSIA HUOLTO AINOASTAAN
AMMATTILAISEN SUORITTAMANA
VAROITUS
L N
E
N L
E
Pistoliitin Liitäntärasia

NRS70 Series SECTION 0
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 0.4
Símbolos de Segurança
O símbolo triangular adverte para a necessidade de consultar o
manual antes de utilizar o equipamento ou efectuar qualquer ajuste.
Este símbolo indica a presença de voltagens perigosas no interior
do equipamento. As peças ou partes existentes no interior do equipamento
não necessitam de intervenção, manutenção ou manuseamento por parte
do utilizador. Reparações ou outras intervenções devem ser efectuadas
apenas por técnicos devidamente habilitados.
As instruções de manutenção fornecidas são para
utilização de técnicos qualificados. Para reduzir o
risco de choque eléctrico, não devem ser realizadas
intervenções no equipamento não especificadas no
manual de instalações a menos que seja efectuadas
por técnicos habilitados.
Para reduzir o risco de choque eléctrico, não expor este equipamento
à chuva ou humidade.
Assegurar que a unidade está sempre devidamente ligada à terra e
que as ligações à alimentação estão correctas.
O sistema de alimentação do equipamento deve, por razões de
segurança, possuir ligação a terra de protecção e ligação ao
NEUTRO devidamente identificada.
A tomada de energia à qual a unidade está ligada deve situar-se na
sua proximidade e facilmente acessível.
Ligação da alimentação noutros países que não os EUA
O equipamento é, normalmente, enviado com cabo de alimentação com ficha
IEC fêmea standard num extremo e uma ficha IEC macho standard no extremo
oposto. Se for necessário substituir ou alterar alguma destas fichas, deverá
remove-la e elimina-la imediatamente de maneira segura.
O código de cor para os condutores é o seguinte:
Condutor VERDE/AMARELO ligado a E (Terra)
Condutor AZUL ligado a N (Neutro)
Condutor CASTANHO ligado a L (Vivo).
Atenção: Se a unidade tem duas fontes de alimentação assegurar que os
dois cabos de alimentação estão ligados a tomadas pertencentes à mesma fase.
P
!
!
Avisos de Segurança
L N
E
N L
E
Ficha Livre Tomada Livre
Products employing Lithium batteries
Power cable supplied for the USA
The equipment is shipped with a power cord with a standard IEC molded free socket on one end and a
standard 3-pin plug on the other. If you are required to remove the molded mains supply plug, dispose of the
plug immediately in a safe manner. The color code for the cord is as follows:
GREEN lead connected to E (Protective Earth
Conductor)
BLACK lead connected to L (Live Conductor)
WHITE lead connected to N (Neutral Conductor)
For products with more than one power supply inlet
Caution:
To reduce the risk of electric shock plug each power supply cord into separate branch circuits
employing separate service grounds.
G
CAUTION
This equipment contains a lithium battery.
There is a danger of explosion if this is replaced incorrectly.
Replace only with the same or equivalent type.
Dispose of used batteries according to the instructions of the manufacturer.
Batteries shall only be replaced by trained service technicians.

NRS70 Series SECTION 0
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 0.5
Rack Mounting the Enclosure
When rack-mounting the product, one of the following methods of installation must be used: -
•Place the unit on a suitably specified, and installed rack shelf and secure the product to the rack via the
front rack ears or,
•Fit the unit using the rear rack mount kit available from Snell & Wilcox by quoting the order code FGACK
RACK-MNT-KIT.
This product must not be rack mounted using only the front rack ears.

NRS70 Series SECTION 0
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 0.6
Safety Standard
This unit conforms to the following standards:
BS EN60950:1992 Specification for safety of information
technology equipment, including electrical business equipment
cULus Listed Professional Video Equipment File No. E193966
EMC Standards
This unit conforms to the following standards:
BS EN 55103-1 : 1997
Electromagnetic Compatibility, Product family standard for audio, video, audio-visual and entertainment lighting
control apparatus for professional use. Part 1. Emission
BS EN 55103-2 : 1997
Electromagnetic Compatibility, Product family standard for audio, video, audio-visual and entertainment lighting
control apparatus for professional use. Part 2. Immunity
Federal Communications Commission Rules Part 15, Class A :1998
EMC Environment
The product(s) described in this manual conform to the EMC requirements for, and are intended for use in,
either
The commercial and light industrial environment (including, for example, theatres) E2
or
The controlled EMC environment (for example purpose-built broadcasting or recording studios), and the rural
outdoor environment (far away from railways, transmitters, overhead power lines, etc.) E4
The applicable environment is stated in the Technical Profile section of the product operation manual under
“EMC Performance Information/Environment.”
EMC Performance Information
Please refer to the Technical Profile/Specifications section of the product operation manual.
EMC Performance of Cables and Connectors
Snell & Wilcox products are designed to meet or exceed the requirements of the appropriate European EMC
standards. In order to achieve this performance in real installations it is essential to use cables and connectors
with good EMC characteristics.
All signal connections (including remote control connections) shall be made with screened cables terminated in
connectors having a metal shell. The cable screen shall have a large-area contact with the metal shell.
COAXIAL CABLES
Coaxial cables connections (particularly serial digital video connections) shall be made with high-quality
double-screened coaxial cables such as Belden 8281 or BBC type PSF1/2M.
D-TYPE CONNECTORS
D-type connectors shall have metal shells making good RF contact with the cable screen. Connectors having
"dimples" which improve the contact between the plug and socket shells, are recommended.
No: 60AA
Professional Video
Equipment

NRS70 Series SECTION 0
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 0.7
About this Manual
This manual covers the following products:
•NRS70 and NRS70TX
Digital Noise Reducers
Packing List
The unit is supplied in a dedicated packing carton provided by the manufacturer and should not be accepted if
delivered in inferior or unauthorised materials. Carefully unpack the carton and check for any shipping damage
or shortages.
Any shortages or damage should be reported to the supplier immediately.
Enclosures:
•
NRS70 unit
•
Power cable.
•
This Operator's Manual
•
Balanced (25 way D) I/O audio rear panel
Software Version Amendments
Notes about Versions Fitted
Software. The NRS70/NRS70TX is shipped with Version 6.6. . 8 of the software.
Manufacturers Notice
Copyright protection claimed includes all forms and matters of copyrightable material and information now
allowed by statutory or judicial law or hereinafter granted, including without limitation, material generated from
the software programs which are displayed on the screen such as icons, screen display looks etc.
Reproduction or disassembly of embedded computer programs or algorithms prohibited.
Copyrighted names: Microsoft Windows™
Information in this manual and software are subject to change without notice and does not represent a
commitment on the part of Snell & Wilcox Ltd. The software described in this manual is furnished under a
licence agreement and may not be reproduced or copied in any manner without prior agreement with Snell &
Wilcox Ltd. or their authorised agents.

NRS70 Series SECTION 0
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 0.8
Table of Contents
SECTION
1 Introduction
Description.......................................................................................................................... 1.1
Features ............................................................................................................................. 1.2
2 Specifications ................................................................................................................... 2.1
3 Installation
Unpacking the CVR550...................................................................................................... 3.1
Power Connections ............................................................................................................ 3.1
Removing and fitting a rear connecting panel.................................................................... 3.2
Input Connections............................................................................................................... 3.2
Output Connections............................................................................................................ 3.4
Communication Connections ............................................................................................. 3.5
Opening and Closing the Front Panel ................................................................................ 3.6
Installing/Removing a Module ............................................................................................ 3.7
Matching the Front Panel to a Gateway Address............................................................... 3.9
4 Operation
The Control Panel............................................................................................................... 4.1
Using the Dedicated Push Buttons..................................................................................... 4.3
Browse ................................................................................................. 4.3
Menu System diagram ......................................................................... 4.5
Front Panel Controls
Input ..................................................................................................... 4.6
Audio .................................................................................................... 4.9
Y Gain, Black Level, C Gain and Hue ................................................. 4.14
Proc Amp ............................................................................................. 4.14
Noise Reduce....................................................................................... 4.15
Memory ................................................................................................ 4.16
Enhance............................................................................................... 4.17
Genlock................................................................................................ 4.18
Setup.................................................................................................... 4.19
RollCall Control Templates................................................................................................. 4.27
5 Modes of Operation
Modes of Operation............................................................................................................ 5.1
RollCall CONTROL via a PC.............................................................................................. 5.3
Advanced Front Panel Controls.......................................................................................... 5.6

NRS70 Series SECTION 0
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 0.9
Product Support Procedure
If you experience any technical or operational difficulties with a Snell & Wilcox product please do not hesitate
to contact us or utilize our online form to request assistance.
There is a lot of information you can give us that will enable us to diagnose your problem swiftly. Please read
the following guidelines, as these suggestions will help us to help you.
Basic Information
For Units ..................... Please provide the exact product Model, unit Serial Number and Software
Version information.
For Cards or Modules . Please provide the Sub-Assembly Number, card Serial Number and the
Software Version information.
Basic Application
Inputs .......................... Please provide full details of the Input Signals being used including any
references etc. and where they are being generated.
Outputs ....................... Please provide full details of the Output Signals required and how they are
being monitored.
System ........................ Please provide a brief description of the system in which your S&W equipment
is currently being used.
Basic Tests
Preset Unit .................. Please use the Preset Unit function to return the settings back to the factory
default.
RollCall ........................ Is your unit currently connected to a RollCall capable PC? This software is
obtainable for free and provides a very user friendly GUI for virtually all S&W
equipment - perfect for complex products, large systems or those with passive
front panels.
Card Edge Info. ........... What is the status of the card edge LEDs or display? These can often provide
information such as power status and input detection conditions.
Internal TPG ............... Many S&W products have an internal test pattern/tone generator. Please
activate this to assist you with your problem analysis.
In addition to the above, please do not forget to provide us with all of the necessary contact information:
•Names
•Telephone & Fax numbers
•e-mail addresses
•Business address
A form has been provided for this information and will be found on the next page or an on-line form is available
on the Snell & Wilcox website at:
http://www.snellwilcox.com/support/request

NRS70 Series SECTION 0
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 0.10
Product Support Request Form
Name: *
Company:
Address Details: *
Post/ZIP Code:
Country: *
Telephone: *
Fax:
Email: *
Local S&W Center: *
Product Name: *
Switchers (i.e. Magic DaVE, Switchpack, Kahuna)
File & Data Transfer Products (i.e. RollCall, Memphis & Asteroid)
Product Type: *
Video Products (i.e. Modular, Kudos Plus and Alchemist)
Unit Serial Number: *
Fault/Spare Part Information: *
(please advise us how many
units show this fault and the
system layout showing all other
manufacturers' products)
e-mail
* Preferred Method of Contact: Phone
•Item is required.
Please mail to:
Snell & Wilcox Ltd.,
Southleigh Park House,
Eastleigh Road,
Havant,
Hants,
PO9 2PE.
United Kingdom.
Service Contact Information:
Tel: +44 (0) 2392 489058
Fax: +44 (0) 2392 489057
http://www.snellwilcox.com/support
ftp://ftp.snellwilcox.com/support

NRS70 Series SECTION 0
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 0.11
Manual Revision Record
Date Version No. Issue No. Change Comments
070503 1 1 First issue released
070803 1 2 Data for installing enclosed
balanced audio I/O rear added. Complete new manual issued

NRS70 Series SECTION 1
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 1.1
Description - NRS70/NRS70TX
The NRS70 is a powerful frame-recursive noise
reducer. Designed for use in live broadcast and
post-production operations, it also provides an
economical pre-processing solution in DVD
authoring.
The NRS70 provides much improved performance
compared with adaptive technology. It
automatically eliminates almost all background
noise by a combination of techniques and filters.
A sophisticated motion detector seamlessly
switches off the noise reduction in moving picture
areas. A median filter is included to remove
impulse noise, and an additional sparkle filter can
be switched in constantly to provide extra noise
reduction with no compromise in picture quality.
In addition to noise reduction, the NRS70 also
provides multi-standard Y/C, composite and SDI
timebase correction and synchronization. The
composite input automatically detects PAL, NTSC,
NTSC-J, PAL-N, PAL-M, N4.43 and SECAM, and
is sampled and decoded using an adaptive comb
filter to ensure optimum decoding performance.
The signal correction features include RGB gamut
legalizer, luminance and chrominance gain, black
level, NTSC hue, vertical and horizontal
enhancers, Y-C horizontal timing and picture
position. Rugged sync and clock recovery ensure
reliable operation with unstable and noisy inputs.
Signals can be output as digital component SDI or
as broadcast quality composite. The 12-bit output
encoder is fully genlockable to a composite
reference and supports PAL, NTSC, NTSC-J,
PAL-N, PAL-M, N4.43 and SECAM. The NRS70
will also operate as a transcoder between any of
the available standards of the same line rate.
The NRS70 also has two separate AES inputs to
enable audio embedding into any of the eight pairs
of the SDI output. Individual channel routing is also
provided, along with two AES outputs.
Other features include freeze, pattern generation,
and GPI control / audio delay flag output. Full
RollCall remote control is available including
RollTrack for
audio delay tracking.
NRS70
NRS70TX
NRS70, NRS70TX
Fuse
ROLLCALL
AES OUT
AES IN 625
AUDIO R EFERENCE
A
B
ABAB
INPUTS
525 SDI
12
GPI/O
COMPOSITE
YC
AB
100-240V~
60/50 Hz
1.8A
T
T2A H 250V
OUTPUTS
COMPOSITE SDI
1
C
Y212
REMOTE

NRS70 Series SECTION 1
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 1.2
Features - NRS70/NRS70TX
•
4:2:2 Noise reducer with frame synchronizer
•
Powerful frame recursive noise reducer with automatic noise floor measurement
•
Sophisticated motion detector seamlessly switches off the noise reduction in moving picture areas
•
Recursive, median and sparkle filters included with option to enable sparkle filter constantly without
compromising picture quality.
•
Linear horizontal and vertical enhancer
•
Broadcast quality 12-bit encoder
•
Synchronizes up to 4 channels of audio with the noise reduced video

NRS70 Series SECTION 2
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 2.1
Technical Profile NRS70 Versions
Features
Signal Inputs
SDI 2 via BNC connector - SMPTE
259M –1997 and embedded audio
SMPTE 272M level A
Composite 2 via BNC connectors
Y/C 1 via 2 BNC connectors
AES/EBU Audio 2 x BNC; Unbalanced, 25-100kHz
asynchronous or 48kHz
synchronous to input video –
SMPTE 276M-1995
Reference (525) 1 via Loop-Through BNC
connectors
Reference (625) 1 via Loop-Through BNC
connectors
Signal Outputs
Composite 2 programme outputs via BNC
connectors
Y/C 1 programme output via 2 x BNC
connectors
Serial Digital
Component (SDI)
2 outputs via BNC connectors
AES/EBU Audio 2 x BNC; Unbalanced, 48KHz
synchronous to output video
Control Interface
GPI I/O 2 via BNC connectors Closing
contact Input/Output
RollCall Via BNC connector
Remote S & W RollCall RS485 or RS422
@ 38 kB via 9 way D connector
Front Panel Controls
Input Select Composite A/B, SDI A/B, Y/C
Audio
Y Gain
C Gain
Black Level
Hue
Noise Reduction On / Off
Noise Reduce Level Y Noise Reduction Level Off / Low
/ Medium / High
C Noise Reduction Level Off / Low
/ Medium / High
Recursive Threshold Auto + 7 manual levels
Enhance On / Off
Memories 8 locations
Genlock On / Off
Browse
Setup
Audio Controls
Gain L & R Separate L & R controls for each
embedder
± 6dB in 0.25dB steps
Invert L & R Separate L & R controls for each
embedder On / Off
Mute L & R Separate L & R controls for each
embedder On / Off
Disable Separate controls for each
embedder On / Off
Default Output Separate controls for each
embedder
Tone, Silence, Disable
Audio delay 1 – 160 ms
Tone Setup:
Amplitude -30dBFS to 0dBFS in 1dB steps
Frequency 100Hz to 10kHz in 100Hz steps
Right Channel Ident Pulse interruption every ~2s
Indicators
Input Loss
Reference Loss
Information
Readback
Audio Embedded channel data present,
AES inputs present
EDH present : error minute : error hour
Delay
Software Version
Serial Number
Unit temperature OK, Near Limit, and Overheating
Additional
RollCall™
Functions
Logging Reference, Input, Output
Standard, EDH, AES Inputs,
RollTrack Set up to 10 unit destinations for
Input Loss, Input restore or Delay
information
System Parameters
Internal Processing 4:2:2 with 10 bit or greater data
paths
Encoder
Composite Encoding 12 bit
Y Frequency Response 5.5 MHz ± 0.05 dB
U/I/Db & V/Q/Dr
Frequency Response 1.3 MHz <-3 dB, 4.0MHz <-20dB
Differential Gain Better than 0.2%
Differential Phase Better than 0.2°
SCH Phase 0 ± 2°

NRS70 Series SECTION 2
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 2.2
Composite Output
Return Loss Better than 35 dB to 5.8 MHz
Free run frequency
error < 10ppm
Genlock SC jitter < 0.5 deg
Decoder
Standards PAL, NTSC, NTSC-J, PALM,
PALN, N443, SECAM
Y Frequency Response 5 MHz +0.2 dB, -0.5 dB
Signal/Noise Ratio Better than –65dB (Weighted,
Ramp)
2T Pulse-Shape K-
rating Better than 0.5%
PbPr Frequency
Response 1.5MHz –3dB
Y non-linearity Better than 0.5%
Differential Gain Better than 0.5%
Differential Phase Less than 0.5deg (5 step
modulated staircase)
Encoder Controls
Composite Output
Standard
625 – PAL, PALN, SECAM
525 – NTSC, NTSC-J, PAL-M,
N443
Minimum Blanking On / Off for 625 and 525 outputs
PAL-I Blanking On / Off for PAL output
VITS insert On / Off for 625 and 525 outputs
Pass Vertical Data On / Off
SECAM Bottles On / Off
SECAM Notch On / Off
SECAM Carrier On / Off
SECAM Chroma
Prefilter
On / Off
Decoder Controls
Input Standard Auto / Manual PAL, NTSC, NTSC-
J, PALM, PALN, N443, SECAM
ACC On / Off
AGC On / Off
NTSC Hue ±30°
VBI Pass Selectable pass or blank for each
vertical interval line
Noise Reducer
Controls
Y Noise Reduction
Level
Off / Low / Medium / High
C Noise Reduction
Level
Off / Low / Medium / High
Sparkle Filter On / Off
Median Filter On / Off
Recursive Threshold
Level
Auto + 8 manual levels
Split Screen Off, Left-Right, Top-Bottom
Specifications
Return Loss: Inputs better than 35 dB to 5.0 MHz
Return Loss: Outputs better than 30 dB to 5.0 MHz
Return Loss SDI Inputs better than 15 dB at 270 MHz
Return Loss SDI Outputs better than 15 dB at 270 MHz
Power
Mains Supply 115/230V 60/50 Hz 1.2 A
Power Consumption 140 W max
Mechanical
Temperature Range 0°to 40°C operating
Cooling Axial fan
Case Type 1RU Rack Mounting
Dimensions Overall 483 x 440 x 45 mm.
(w x d x h).
Depth from mounting face
(including unmated connectors)
415 mm.
Weight 9.75 kg
EMC Environment
This unit is intended for use in the
commercial and light industrial
environment E2.

NRS70 Series SECTION 3
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 3.1
Installation
Unpacking the NRS70
The unit is packed in a single carton. The contents
of the flight case are as follows:
•
NRS70 unit
•
Power cable.
•
This Operator's Manual
•
Balanced (25 way D) I/O audio rear panel
Unpack the carton carefully and check for any
shortages or shipping damage. Immediately report
any shortages or damage to Snell and Wilcox
Limited.
POWER CONNECTIONS
Power Supply
Mains power is supplied to the unit via a filtered IEC
connector.
The mains power fuse rating is 2 A (T) HBC and the
rated current for the unit is 1.2 A.
The power supply ON/OFF switch is located on the
front of the power supply inside the front panel.
CAUTION: THE VENTILATION HOLES AT THE
SIDES OF THE UNIT AND THE FAN EXIT AREA
MUST NOT BE OBSCURED.
Supply Voltage
The power supplies are auto switching for input
voltages in the ranges of 100 V to 250 V nominal.
No voltage adjustment procedure is required.
CAUTION: THIS UNIT MUST NOT BE
OPERATED WITHOUT
AN EARTH CONNECTION.
Fuse
100-240V~
60/50 Hz
1.8A
T
T2A H 250V
E
MOTE
I
O
Rack Mounting the 1U Enclosure
The product must not be rack mounted using only the front rack mounting ears. When installing the product in
a rack one of the following methods must be used: -
•Place the unit on a suitably specified, and installed rack shelf and secure the product to the rack via the
front rack ears
•Alternatively fit the unit using additional rear rack mounts
A suitable mounting kit is available for purchase from Snell & Wilcox by quoting the order code:
FGACK RACK-MNT-KIT
Note: The rear mounting brackets must be attached using the two M3 threaded inserts on both sides of the
product; the maximum length of screw that can be used is M3 x 6mm. Ensure that the product is secured to
the rack in all four corners.

NRS70 Series SECTION 3
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 3.2
Removing and fitting a rear connecting panel
Warning: Remove power from the unit when performing these operations
Removing a rear connecting panel
1. At the rear of the enclosure remove the screws securing the rear panel to the mainframe.
2. Remove the rear panel by pulling the rear panel away from the mainframe in a straight line.
Fitting a rear connecting panel
1. Ensuring correct panel orientation and correct alignment of the multi-way connector fit the rear connecting
panel to the rear of the enclosure by inserting the panel into the mainframe in a straight line.
2. Secure the panel with the fixing screws.
Warning: The rear of the enclosure must have a full complement of rear panels fitted when powered-up.
INPUT CONNECTIONS
Composite A and B
These are the 2 Composite video inputs to the
decoder module via BNC connectors. Nominal input
level is 1 V p-p terminated in 75 Ohms.
Separated Y C
A Y-C (S-VHS, Hi-8 etc.) input signal may be
connected to the unit via 2 BNC connectors.
Y should be connected to Composite A and C to
Composite B.
Y input level is a nominal 1V p-p into 75 Ohms.
C input is nominal colour burst level into 75 Ohms.
SDI A & B
These are the 2 SDI inputs to the unit via BNC
connectors.
AES A & B (BNC Rear Panel)
These are the 2 unbalanced AES/EBU Audio inputs
to the unit via BNC connectors. Nominal input level
is 1 V p-p terminated in 75 Ohms.
COMPOSITE
YC
AB
COMPOSITE
YC
AB
AB
INPUTS
SDI
AES IN
AUDIO
AB

NRS70 Series SECTION 3
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 3.3
AES A & B (25 way D Rear Panel)
All balanced audio connections are made via the 25
way D Connector.
AUDIO
25 Way D Connection Details
25 Way D Connector
Pin Number Description Ribbon Cable
Strand Number Standard Pin Assignment
1 1 CHASSIS
14 AES IN A Gnd 2 GND1
2 AES IN A + 3 1+
15 AES IN A - 4 1-
3 AES IN B + 5 2+
16 AES IN B - 6 2-
4 AES IN B Gnd 7 GND2
17 Unused 8 GND3
5 Unused 9 3+
18 Unused 10 3-
6 Unused 11 4+
19 Unused 12 4-
7 Unused 13 GND4 (CH)
20 Unused 14 GND5
8 Unused 15 5+
21 Unused 16 5-
9 AES OUT A + 17 6+
22 AES OUT A - 18 6-
10 AES OUT A Gnd 19 GND6
23 AES OUT B Gnd 20 GND7
11 AES OUT B + 21 7+
24 AES OUT B - 22 7-
12 Unused 23 8+
25 Unused 24 8-
Reference Inputs
525 and 625
When suitable signals are connected to these
inputs, the video output of the unit will be fully
synchronised to the relevant signal source when the
genlock function is selected. There are separate
inputs for 525 and 625 line standard signals. If no
signal is present the unit will automatically revert to
internal free-running operation.
BNC loop-through connectors are provided and the
signal may be black burst or composite video at
standard level.
625
REFERENCE
525

NRS70 Series SECTION 3
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 3.4
OUTPUT CONNECTIONS
Composite Outputs 1 & 2
Two isolated composite outputs are available from
these BNC connectors.
Output level is standard 1V p-p into 75 Ohms.
SDI 1 & 2
These are the 2 SDI outputs of the unit via BNC
connectors.
Y-C Separated Output
A Y-C (S-VHS/Hi-8) output signal is available via
these 2 BNC connectors marked Y and C.
Y output level is a nominal 1 V p-p into 75 Ohms.
C output is a nominal colour burst level into 75
Ohms.
AES A & B (BNC Rear Panel)
The unbalanced audio outputs can be configured to
be AES input A/B, embedded audio or internally
generated test tone.
AES A & B (25 way D Rear Panel)
All balanced audio connections are made via the 25
way D Connector.
For connection details please see page 3.4,
25 Way D Connection Details.
OUTPUTS
COMPOSITE
12
SDI
12
C
Y
AES OUT
2
1
AUDIO

NRS70 Series SECTION 3
NRS70OPS 070803 Version 1 Issue 2 www.snellwilcox.com 3.5
COMMUNICATIONS CONNECTORS
Remote
This 9 pin `D' connector on the rear panel allows
the unit to be connected to the RollCall 485 network
communications system. This connector may also
be used as a RS422 port. For more information see
Section 5 Modes of Operation.
RollCall
This single BNC connector allows the unit to be
connected to the RollCall network communications
system.
GPI I/O 1 and 2
These BNC connectors provide GPI input and
output control for the module.
Both GPI1 and GPI2 may be configured as inputs
that will allow memory locations to be recalled.
GPI2 may be configured as an output and will
provide an audio delay flag representing the video
delay through the unit.
100-240V~
60/50 Hz
1.8A
T
T2A H 250V
REMOTE
ROLLCALL
IQ AUDIO
DAC
Y
12
GPI/O
C
O
M
P
O
S
I
T
E
This manual suits for next models
1
Table of contents
Other Snell & Wilcox Recording Equipment manuals