1-5 (E)
HDCU-F950 IMM
1-4-2. Connection Connectors
When connecting cables to each connector of the connec-
tor panel during installation or service, connect the follow-
ing connectors or equivalent to the tip.
Connector Connector/cable
HDCU-F950
CAMERA LEMO®
PUW. 3K. 93C. TLCC96 *1
(HDC-F950 side)
CCU LEMO®
FUW. 3K. 93C. TLMC96 *1
REFERENCE IN 1-569-370-12 PLUG, BNC
SYNC OUT
PROMPTER IN
RET IN (1-3)
1-569-370-12 PLUG, BNC or
LINK A OUTPUT (1-2, MONI)
BELDEN8281 Cable or
LINK B OUTPUT (1-2) equivalent
HD SDI OUT (1-2)
MIC1/MIC2 1-508-083-00 XLR 3-pin female
(3-pin, Male) or CANNON XLR-3-11C
equivalent
MIC REMOTE 1-506-582-11 D-sub 15-pin, male
(WF REMTOE) or JAE DA-CI-J10 equivalent
(D-sub 15-pin, Female)
INCOM/TALLY/PGM D-sub 25-pin, male
(D-sub 25-pin, Female) JAE DA-25PF-N equivalent
RCP/CNU 1-766-848-11 PLUG, 8-pin male
(8-pin, Female)
or CCA cable assembly (optional)
CCA-5-30 (30 m), CCA-5-10
(10 m), CCA-5-3 (3 m)
INCOM 1-508-370-11 XLR 5-pin, male
(5-pin, Female) or CANNON XLR-5-12C
equivalent
TRUNK LINE 1-560-078-00 PLUG, 6-pin male
(6-pin, Female) or HIROSE HR10-7PA-6P
equivalent
*1 : Caution in making the optical/electric signal composite cable:
When making the optical/electric signal composite cable used for this
camera system, the connection connectors specified in this manual
must be used in order to comply with the limits for EMC regulations.
1-4-3. Note when Connecting CAMERA
Connector
Before connecting the unit to the camera adapter, clean the
following optical contact blocks.
For the cleaning procedure, refer to Section 3-1, “Cleaning
of Connector/Cable”.
.CAMERA connector of the unit
.CCU connector of the camera adaptor side
.Optical/electric signal composite cable
1
2
3
4
5
RCP/CNU (8-pin, Female)
__
__
_EXT VIEW __
__
_
No. Signal Specifications
1 TX (+) CCU SERIAL DATA
2 TX (_)
3 RX (+) RCP/CNU/BVP/MSU/
4 RX (_) VCS SERIAL DATA
5 TX GND GND for TX
6 POWER (+) OUT RCP POWER, +30 V
7 POWER (_) OUT GND for POWER
8 SPARE
INCOM (5-pin, Female)
_ _
_ _
_ EXT VIEW __
__
_(0 dBu = 0.775 Vrms)
No. Signal Specifications
1 INCOM (T) IN (Y) _20 dB
2 INCOM (T) IN (X) (CARBON MIC)
_40 dB
(ECM MIC)
_60 dB
(DYNAMIC MIC)
3 INCOM (T) IN (G) GND for INCOM
4 INCOM (R) OUT (X) Max. 12 dBu
5 NC No connection
TRUNK LINE (6-pin, Female)
_ _
_ _
_ EXT VIEW __
__
_
No. Signal Specifications
1 TX_DATA (0) OUT TRUNK DATA OUT
2 TX_DATA (1) OUT RS-232C
3 RX_DATA (0) IN TRUNK DATA IN
4 RX_DATA (1) IN RS-232C
5 LFE SYNC OUT VALID : 0 Vdc,
INVALID : +3 Vdc
6 GND
1
2
3
45
6
7
8
1
2
34
5
6