Sound Acoustics PRO-RVC User manual

Premium Residential & Commercial Audio/Video Products
PRO-RVC
REMOTE LINE / MIC MIXER
Owner's Manual

Introduction
Congratulations and thank you for purchasing a Sound Acoustics product. The
PRO RVC is a stand alone flush wall mounted microphone/line mixer that can
operate independently or with Sound Acoustics amplifiers. The PRO RVC is
perfect for adding extra inputs to an audio systems with remote control of mix
balance and master volume control. Please read this entire manual to get the
most from your Sound Acoustics PRO RVC.
Includes:
1 x PRO RVC mic/line mixer
2 x Mounting Screws
1 x Installation manual
3 x Knob security covers
Connecting to ound Acoustics Amplifiers:
Ensure the amplifier is powered off and unplugged from the wall ac outlet
before making connections.
Carefully unpack the PRO RVC.
Run a Cat5, Cat5e or Cat6 cable from the amplifier to the PRO RVC location.
Terminate the wire in a single gang electrical box or use a drywall mud ring at
the PRO RVC location.
Caution: Ensure the connections (pinnings) are exactly the same at both ends
of the cable. See diagram below.
The back panel of the PRO RVC provides two RJ45 female jacks. OUT1 (to
amplifier) and IN1 (from additional PRO RVC's) Push the connector/cable into
the jack until the jack clicks and is seated firmly. All Sound Acoustics amplifiers
provide a back panel RJ45 female jack for connecting the PRO RVC. When using
multiple PRO RVC's (max 3) connect the OUT1 from PRO RVC # 2 to the IN1 of
the first PRO RVC and repeat for PRO RVC #3. See the following diagram.

Connecting to Non ound Acoustic Amplifiers:
It is possible to use the PRO RVC with other manufacturers amplifiers, mixers
and receivers.
Follow the steps listed above and install the optional RVC ADAPT between the
master PRO RVC and the amplifier.
The RVC ADAPT converts the RJ45 output of the PRO RVC to individual line
level output, phantom power and master volume control. Connect the RVC
ADAPT power supply.
Connect the RVC ADAPT output to an unused line level input on the mixer,
amplifier or receiver. Some commercial amplifiers also include a remote master
volume contact that can be controlled from the RVC ADAPT RVC output.

Operation:
NOTE: The PRO RVC is a powerful microphone/line amplifier. Always start will
the volume controls off (turned fully counter clockwise) and adjust slowly. This
will avoid feedback and possible damage to the amplifier and loudspeakers.
Once up to 3 PRO RVC's are properly connected, re connect the AC power cord
of the amplifier to the AC wall outlet and power the amplifier ON.
Always start with the PRO RVC volume controls turned all the way down
counter clockwise.
Turn the amplifier master volume control to 2/3rds full.

Connect a microphone into the microphone input jack on the PRO RVC. Turn
the master volume control up to 12:00 50% full.
Slowly turn the microphone volume control up while speaking into the
microphone until you reach the desired volume level. Repeat the same
procedure for the dual RCA jacks with a CD, DVD or other music source.
Automatic Override
Momentary Override: Sound Acoustics amplifiers provide a back panel
priority switch. Set the priority switch to ON to momentarily override all other
sources plugged into the amplifier.
Constant Override: Sound Acoustics amplifiers provide a back panel MUTE
connection. Use this to constantly override all other sources connected to the
amplifier (does not effect the TEL or priority inputs). This prevents other
sources from being broadcast between music passages or spoken word phrases.
Connect a switch or use contact closure to the MUTE contacts. This can be
installed at the PRO RVC location allowing remote control of the override
feature.
pecifications:
Frequency Response: 20Hz – 20kHz
Signal – Noise Ratio Microphone: 70dB
Signal – Noise Ratio Line: 80dB
Power Requirements:24V DC (Not required when using with Sound Acoustic
Amplifiers)
Dimension Face Plate: W 70mm x H 150mm x D 50mm / W 2.75” x H 5.9” x D
1.96”
(Depth Fits Single Gang Electrical Boxes)
Shipping Weight: 0.45 kg /1 lb
Contact Information
Sound Acoustics HQ
1360 Frances Street
Vancouver BC Canada V5L 1Y9
E mail: [email protected]
Website: www.mysoundacoustics.com
Warranty
The Sound Acoustics PRO RVC is warranted to be free from defects in
workmanship and materials for a period of three (3) years without charge for
parts or labour. The warranty applies only to the original owner. The owner’s
responsibilities are to provide proof of purchase and transportation to the
dealer the unit was purchased from or transportation to the Sound Acoustics
factory. This warranty does not apply to units which have been subject to
misuse, abuse, neglect or improper installation, and does not apply to repairs
or alterations by unauthorized personnel. This warranty specifically excludes
responsibility for consequential damage.
Retention of your dated ORIGINAL BILL OF SALE is required to obtain service
under the terms of the warranty.
Table of contents