Soundoff Signal Mpower EMPSC07M Series User manual

7X3 / 6X4 Silicone_BACKUP
00KPJL 0822 REV B
1.800.338.7337 / www.soundosignal.com
BACKUP LIGHT
EMPSC07M(x)-(x) - 7X3 Quick Mount, Screw Mount, & Stud Mount
EMPSB0C9(x)-(x) - 6X4 Quick Mount, Screw Mount, & Stud Mount
With Clear Duty® Technology
• HIGH CURRENT interconnects must be properly terminated. Poor crimp
quality can cause heat build-up and fire. Follow the crimp connector
manufacturer instructions.
• DO NOT install this product or route any wires in the Air Bag Deployment
Zone. Refer to vehicle Owner’s Manual for deployment zones.
• Do NOT use system to disconnect headlights, brake lights or other safety
equipment.
• Unit may become hot to touch during normal operation.
• Failure to properly install connectors, fuses or wiring may cause vehicle
failure or fire.
• Installation must only be performed by trained technician. Installer must
determine vehicle wiring configuration and proper integration of system.
• Use proper wire gauge. All power wires connecting to positive (+) or
negative (-) battery terminal or local chassis ground (-) must be sized to
supply at least 125% of max. current and properly fused at power source.
• Install protective grommets when routing wire through firewall or metal.
• Petroleum/silicone based lubricants will cause the silicone lens to discolor.
NOTICE:
Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning
devices. Improper use or installation may void warranty coverage.To review our Limited Warranty Statement & Return Policy
for this or any SoundO Signal product, visit our website at www.soundosignal.com/tech-services/returns/. If you have
questions regarding this product, contact Technical Services, Monday - Friday, 8 a.m. to 5 p.m. ET at 1.800.338.7337 (press
#4). Questions or comments that do not require immediate attention may be emailed to techservices@soundosignal.com.
ENHANCING SAFETY THROUGH INNOVATION
WARNING
!
ROUTE WIRES ONLY IN LOCATIONS THAT ARE NOT SUBJECTED TO
POTENTIAL WEAR. MAKE SURE TO AVOID ROUTING WIRES IN THE
DEPLOYMENT AREA OF YOUR AIR BAG. REFER TO YOUR VEHICLE'S
OWNER'S MANUAL FOR AIRBAG DEPLOYMENT ZONES.
WARNING
Protected by U.S. Patent 10,703,260 and Patents Pending
https://soundoffsignal.com/legal/patent-notification/
DIMENSIONS . . . . . . . . . . . . . . . . . . 2
BACKUP LIGHT OPTIONS . . . . . . . . . 2
TECHNICAL SPECIFICATIONS . . . . . . 3
WIRING INFORMATION . . . . . . . 4-5
QUICK MOUNT INSTALLATION . . . . . 6
STUD MOUNT INSTALLATION . . . . . 6
SCREW MOUNT INSTALLATION . . . . 7
RETENTION CLIP INSTRUCTIONS . . . 8
7x3 Backup Light Shown
6x4 Backup Light Shown

1.800.338.7337 / www.soundosignal.com
27X3 / 6X4 Silicone_BACKUP
00KPJL 0822 REV B
”
””
0.72”
0.44”
DIMENSIONS & BEZEL INFORMATION:
6x4 DIMENSIONS WITHOUT BEZEL
5.0
”
”
”
”
6x4 DIMENSIONS WITH BEZEL*
”
”
”
”
”
7x3 DIMENSIONS WITHOUT BEZEL
””
”
”
7x3 DIMENSIONS WITH BEZEL*
FIG. 1 FIG. 2
FIG. 3 FIG. 4
*Single Bezels are only compatible with Stud & Screw mount versions.
BACKUP LIGHT W/ WARNING OPTIONS:
7x3 & 6x4 LED OPTIONS
• Single Color
7x3 & 6x4 LED COLOR OPTIONS
• Red
• Amber
• Blue
• White
• Green
7x3 & 6x4 CERTIFICATIONS
• SAEJ595
• California Title 13
• NFPA 1901-2009
• KKK-A-1822 (July 2021)
• FMVSS108
(Backup light Only)
7x3 & 6x4 MOUNTING OPTIONS
• Quick Mount
(Not compatible with Bezel)
• Stud Mount
• Screw Mount
7x3 & 6x4 AVAILABLE FLASH PATTERNS
• Double* • Quint*
• Double 2* • Random 1
• Inter-cycle • Random 2
• Power Pulse* • Road Runner*
• Q-switch • Steady-Burn Driver Title 13 Quad
• Quad* • Steady-Burn/Road Runner
• Quad 2* • Warp
• Quad Pulse-pop*
*Certified Flash Patterns
PART NUMBERS (UNCONFIGURED)
• 7x3 - EMPSC0 XXX-X**
• 6x4 - EMPSB0 XXX-X**
**See SoundOff Signal configurator or sales representative
for specific color, lens, and mounting options.

1.800.338.7337 / www.soundosignal.com
37X3 / 6X4 Silicone_BACKUP
00KPJL 0822 REV B
MPOWER®7X3 & 6X4 BACKUP LIGHT W/ WARNING
TECHNICAL SPECIFICATIONS
Input Voltage: 9-32Vdc
BACKUP LIGHT
WITH WARNING
CURRENT CONSUMPTION (Amps)
12.8Vdc 25.6Vdc
Peak Average Peak Average
Red 1.45 0.73 0.73 0.36
Amber, Blue,
Green, or White 1.66 0.83 0.83 0.42
AFTER POWER IS ON, touching the WHITE wire to the ground
will allow you to change various settings on the module.
(Refer to page 4)
TECHNICAL SPECIFICATIONS:
MPOWER®7X3 & 6X4 BACKUP LIGHT
TECHNICAL SPECIFICATIONS
Input Voltage: 9-32Vdc
BACKUP LIGHT
CURRENT CONSUMPTION (Amps)
12.8Vdc 25.6Vdc
Peak Peak
HIGH (SINGLE) 0.86 0.43
LOW (DUAL) 0.43 0.22
AFTER POWER IS ON, touching the WHITE wire to the ground
will allow you to change various settings on the module.
(Refer to page 4)

1.800.338.7337 / www.soundosignal.com
47X3 / 6X4 Silicone_BACKUP
00KPJL 0822 REV B
WIRING AND TABLE INFORMATION:
OVER-VOLTAGE PROTECTION
When an over-voltage condition is detected, the module will flash
an overvoltage warning pattern of 50mS ON/950mS OFF to alert
of the overvoltage condition and protect the electronics from
damage due to heat/voltage.
THERMAL COMPENSATION PROTECTION
The LED module is designed to provide maximum power output
while providing protection to the electronic components by re-
ducing the output power at extreme temperatures.
Lights are chassis-grounded. If you need to
ground-switch the light, you must isolate the lights
metal backing, heatsink, studs and/or screws from
the body of the vehicle or use a relay.
BLACK
RED
WHITE
GREEN
Sync
Set-up/Function
ORANGE
+Vd c
A FUSE
3
+Vd c
+Vd c
A FUSE
3
FIG. 5
FUNCTION TABLE
WIRE LIGHT
RED ORANGE WHITE BACKUP LIGHT
WITH WARNING BACKUP LIGHT ONLY
+9-32V - - FLASH WARNING
COLOR
FMVSS SINGLE LAMP
SYSTEM BACKUP
- +9-32V - STEADY BACKUP
HIGH POWER
FMVSS DUAL LAMP
SYSTEM BACKUP
+9-32V +9-32V - STEADY BACKUP
HIGH POWER
FMVSS SINGLE LAMP
SYSTEM BACKUP
- - +9-32V NO OP NO OP
+9-32V - +9-32V FLASH WARNING
COLOR LOW POWER
FMVSS SINGLE LAMP
SYSTEM BACKUP
- +9-32V +9-32V STEADY BACKUP
LOW POWER
FMVSS DUAL LAMP
SYSTEM BACKUP
+9-32V +9-32V +9-32V STEADY BACKUP
LOW POWER
FMVSS SINGLE LAMP
SYSTEM BACKUP
FEDERAL MOTOR VEHICLE SAFETY STANDARDS
(FMVSS) COMPLIANCE
To be compliant with FMVSS when using the backup function, the
following settings are required:
• Single lamp system – Set the light to Steady Backup High Power
• Dual lamp system – Set each light to Steady Backup Low Power
REMOTE NODE: FOR USE WITH bluePRINT® SYSTEM
ONLY
Connecting the Green wire to ground before applying power to
the Red or Orange wires will place the LED module into remote
mode and the light output color will be directly controlled by the
input wires as shown below. For Cruise mode or Low Power con-
trol of the LED module, the signal to the control wires must be 100
+/- 2Hz using the duty cycle inputs listed below to produce the
light output.
CRUISE MODE DUTY CYCLE
(@ 100Hz)
Input Light Output
40% OFF
50% 5%
60% 10%
LOW POWER FLASH D.C.
(@ 100Hz)
Input Light Output
70% 30%
80% 40%
90% 50%
MPOWER®6x4 & 7x3 BACKUP LIGHT ONLY
REMOTE NODE FUNCTIONALITY
RED ORANGE LIGHT
CRUISE - CRUISE BACKUP COLOR
FLASH - FLASH BACKUP COLOR
STEADY - STEADY BACKUP COLOR
MPOWER®6x4 & 7x3 BACKUP LIGHT WITH
WARNING REMOTE NODE FUNCTIONALITY
RED ORANGE LIGHT
CRUISE - CRUISE WARNING COLOR
- CRUISE CRUISE BACKUP COLOR
CRUISE CRUISE CRUISE BACKUP COLOR
FLASH - FLASH WARNING COLOR
- FLASH FLASH BACKUP COLOR
FLASH FLASH FLASH BACKUP COLOR
STEADY ON - STEADY WARNING COLOR
- STEADY ON STEADY BACKUP COLOR
STEADY ON STEADY ON STEADY BACKUP COLOR
CRUISE FLASH FLASH BACKUP COLOR
CERTIFICATION APPLICABLE COLORS
SAEJ595 Red, Amber, Blue, White,
Green
CALIFORNIA TITLE 13 Red, Amber, Blue
NFPA 1901-2009 Red, Amber, Blue, White
KKK-A-1822F (JULY
2021)
Red, Amber, Blue, White,
Green
FMVSS108
(Backup Only)
White

1.800.338.7337 / www.soundosignal.com
57X3 / 6X4 Silicone_BACKUP
00KPJL 0822 REV B
WIRING AND TABLE INFORMATION (CONT.):
SIMULTANEOUS/ALTERNATE
This function can only be changed when the LED module is
in a flashing mode (disabled in cruise or steady ON functions)
and only has an effect when at least 2 LED modules have the
green sync wire connected together. When the light is flash-
ing, momentarily connect the white wire to ground for >3S
and <4S (light will go steady high, steady low, off, steady high)
then release. The light module will switch between Simulta-
neous and Alternate each time this sequence is done. To have
light modules flash simultaneously, both light modules need
to be set to the same sequence type (Set-Up Table). To have
light modules flash alternately, the light modules need to be
set to different sequence types (Set-Up Table).
ADVANCE PATTERN
Flash pattern can only be changed when the LED module is in
a flashing mode (disabled in cruise or steady ON functions).
When the light is flashing, momentarily connect the white
wire to ground for >250mS and <1S (light will go steady high)
then release. The flash pattern will advance to the next pat-
tern. If the light module was at the last pattern, the pattern
will reset to the 1st pattern.
BACKUP PATTERN
This function is only valid when the LED module is in a flash-
ing mode (disabled in cruise or steady ON functions). When
the light is flashing, momentarily connect the white wire to
ground for >1S and <2S (light will go steady high, steady low)
then release. The flash pattern will backup to the previous
pattern. If the light module was at the first pattern, the pattern
will change to the last pattern on the list.
PATTERN RESET
This function is only valid when the LED module is in a flash-
ing mode (disabled in cruise or steady ON functions). When
the light is flashing, momentarily connect the white wire to
ground for >5S and <6S (light will go steady high, steady low,
off, steady high, steady low, off) then release. The flash pat-
tern will reset to the 1st pattern in the list.
FACTORY RESET
This function is only valid when the LED module is in a flash-
ing mode (disabled in cruise or steady ON functions). When
the light is flashing, momentarily connect the white wire to
ground for >6S and <7S (light will go steady high, steady low,
off, steady high, steady low, off, steady high) then release.
The LED module will reset to: pattern=1, Function Table=1,
Color Swap=OFF, Simultaneous.
LOCKOUT CONFIGURATION WIRE
This function will disable the wire tap configuration mode
that is activated by holding the white wire to ground. The
lock out is activated by applying ground to the white wire for
>7 seconds and <8 seconds per the table below. The function
can be disabled by tapping the wire to ground and releasing
8 times within 5 seconds. The light will flash 8 times when the
feature is enabled or disabled to notify the user of a setting
change.
BACKUP HIGH/LOW POWER
To be compliant with government regulations, a Backup Light
System consisting of Dual Backup Lights shall be operated in
Low Power. A system consisting of one Single Backup Light
shall be operated in High Power.
SETUP TABLE
SECONDS USER INTERFACE
FROM TO VISUAL FEEDBACK ACTION TAKEN
0 1 STEADY-HIGH (60%) FORWARD ONE PATTERN
1 2 STEADY-LOW (30%) BACKWARD ONE PATTERN
2 3 OFF COLOR SWAP (OFF OR ON )
3 4 STEADY - HIGH (60%) SEQUENCE TYPE: SIMULTANEOUS OR
ALTERNATE
4 5 STEADY - LOW (30%) SEE FUNCTION TABLE
5 6 OFF RESET TO PATTERN 1
6 7 STEADY-HIGH (60%)
FACTORY RESET (PATTERN 1, COLOR
SWAP: OFF, SIMULTANEOUS) SEPARATE
COLOR CONTROL: OFF
7 8 STEADY - LOW (30%) LOCK OUT WHITE CONFIGURATION WIRE
If held longer than 8 seconds, the light will go back to flashing
the current pattern and no action will be taken.
SYNC 2
Synchronizing flashing of multiple light modules is accomplished by
connecting the Green wires of different light modules together. Up to
24 light modules can be connected for synchronized flashing. All light
module flash patterns must be set to the same flash pattern # to ensure
proper operation. Refer to Sequence Type section in the Setup Table to
setup light modules to flash in alternate or simultaneous flash pattern.
NOTE: Will NOT work with non-Sync 2 products, such as Ghost, LED3,
and 4 wire Intersector. WILL WORK with Sync 2 products nFORCE Sec-
ondary Lights, nFORCE FIT, and 5 wire Intersector Lights.
FLASH PATTERNS CERTIFICATIONS
PATTERN
#SINGLE COLOR FLASHES
PER MINUTE
HIGH
POWER
LOW
POWER
1 QUINT 70 SAE, KKK SAE, KKK
2 WARP 360 NA NA
3 INTER-CYCLE - NA NA
4 DOUBLE 70 SAE, KKK SAE, KKK
5 QUAD 80 SAE, NFPA,
KKK
SAE, NFPA,
KKK
6 POWER PULSE 180 SAE, NFPA,
KKK
SAE, NFPA,
KKK
7 ROAD RUNNER 118 SAE, CA13*,
NFPA, KKK
SAE, CA13*,
NFPA, KKK
8 Q-SWITCH - NA NA
9
STEADY-BURN / ROADRUN-
NER (SEQUENCE TYPE 1:
STEADY BURN, SEQUENCE
TYPE 2: ROADRUNNER)
- / 118 NA NA
10
STEADY-BURN DRIVER TITLE
13 QUAD (SEQUENCE TYPE
1: STEADY BURN, SEQUENCE
TYPE 2: TITLE 13 QUAD)
- / 65 NA NA
11 QUAD 2 67 SAE, KKK SAE, KKK
12 DOUBLE 2 95 SAE, NFPA,
KKK
SAE, NFPA,
KKK
13 RANDOM 1 - NA NA
14 RANDOM 2 - NA NA
15 QUAD PULSE-POP 75 SAE, CA13*,
NFPA, KKK
SAE, CA13*,
NFPA, KKK
NOTE: FOR BACKUP LIGHT WITH WARNING ONLY

1.800.338.7337 / www.soundosignal.com
67X3 / 6X4 Silicone_BACKUP
00KPJL 0822 REV B
QUICK MOUNT INSTALLATION:
1. Drill a 3/4" wire hole (see Fig. 7).
2. Insert (4) Silicone Plugs into Light to Seal Screw Holes. (Use a 50%
Isopropyl alcohol, 50% deionized water mix for lubrication if
necessary).
3. Prep the back of the light and vehicle mount surfaces with 50%
deionozed water, 50% isopropyl alcohol wipe, and allow to dry.
4. Adhere VHB quick mount to the back of the light and press down
firmly for 15 seconds on full surface.
5. Pull the wire harness through the vehicle wire hole and plug into
the back of the light. Reference page 8 for retention clip instal-
lation.
6. Lightly place the light against vehicle mount surface and check that
the alignment is satisfactory. Once alignment is correct press firmly
against light for 15 seconds to set VHB quick mount.
NOTE: Bezels will not work with the Quick Mount option.
WIRE HOLE
SILICONE
PLUGS
VHB QUICK MOUNT
WIRE HARNESS
FIG. 6
DRILL FOR WIRE EXIT
FIG. 7
STUD MOUNT INSTALLATION:
1. Drill (2) 1/4" holes to mount light. Drill 3/4" wire hole (see Fig. 9).
The drill template shown is compatible with both the the 6x4 and
7x3 stud mount light.
2. Insert (4) Silicone Plugs into Light to Seal Screw Holes. (Use a 50%
Isopropyl alcohol, 50% deionized water mix for lubrication if
necessary).
3. Thread studs into the back of light.
4. Align the gasket to the mounting surface. Horizontal and vertical
orientations are indicated on gasket for proper seal.
5. Place the bezel over gasket.
6. Place the light into bezel, press firmly to make sure bezel and gasket
are tight against mouting surface.
7. Secure the light to mounting surface using (2) supplied nuts.
NOTE: Tighten until gasket is compressed. DO NOT over tight-
en and strip casting threads.
DO NOT USE POWER TOOLS TO
TIGHTEN.
8. Plug the wire harness into the back of the light. Reference page 8
for retention clip installation.
!
PETROLEUM/SILICONE BASED
LUBRICANTS WILL CAUSE THE
SILICONE LENS TO DISCOLOR.
WARNING
STUD MOUNT
C
L
F
G
H
FIG. 8
7X3 STUD MOUNT LIGHT PICTURED
GASKET WIRE HARNESS
SILICONE
PLUGS
BEZEL
NUTS
STUDS
DRILL FOR WIRE EXIT
DRILL FOR STUD MOUNT
C
L
FIG. 9
NOT TO SCALE, FOR REFERENCE ONLY
!
PETROLEUM/SILICONE BASED
LUBRICANTS WILL CAUSE THE
SILICONE LENS TO DISCOLOR.
WARNING
NOT TO SCALE, FOR REFERENCE ONLY

1.800.338.7337 / www.soundosignal.com
77X3 / 6X4 Silicone_BACKUP
00KPJL 0822 REV B
SCREW MOUNT INSTALLATION:
INSERT MOLY ANCHORS INTO DRILLED HOLES, FULLY
SEAT TO MOUNT SURFACE
ALIGN GASKET TO MOUNT SURFACE
(
NOTE HORIZONTAL AND VERTICAL ORIENTATIONS
INDICATED ON GASKET FOR PROPER SEAL)
PLACE BEZEL OVER GASKET PULL THE WIRE HARNESS
THROUGH THE OPENING AND
PLUG INTO THE BACK OF THE
PLACE LIGHT INTO BEZEL, PRESSING BEZEL,
AND GASKET AGAINST MOUNT SURFACE
SUPPLIED SCREWS.
(
TIGHTEN UNTIL GASKET IS COMPRESSED, DO NOT OVER
TIGHTEN AND STRIP MOLY ANCHORS.)
SCREW HOLES.
COATING THE EXTERIOR OF THE PLUG IN 50%
ISOPROPYL ALCOHOL, 50% WATER MIX (HAND SANITIZER
WORKS WELL) WILL ALLOW THE PLUG TO SLIP INTO PLACE
EASIER, AND THE MISTURE WILL EVAPORATE OUT LEAVING
NO RESIDUE.
DRILL FOR WIRE EXIT
DRILL FOR SCREW MOUNT
5
C
L
C
L
SURFACE MOUNT
FIG. 11
DRILL FOR WIRE EXIT
DRILL FOR SCREW MOUNT
C
L
C
L
5
SURFACE MOUNT
FIG. 12
NOT TO SCALE, FOR REFERENCE ONLY
7X3 SCREW MOUNT TEMPLATE
6X4 SCREW MOUNT TEMPLATE
NOT TO SCALE, FOR REFERENCE ONLY
!
PETROLEUM/SILICONE BASED
LUBRICANTS WILL CAUSE THE
SILICONE LENS TO DISCOLOR.
WARNING
FIG. 10
7X3 SCREW MOUNT LIGHT PICTURED
GASKET
WIRE HARNESS
SILICONE
PLUGS
BEZEL WELL NUTS
SCREWS
WIRE HOLE
WASHERS
1. Drill (4) 5/16" holes to mount light. Drill 3/4" wire hole. See
Fig. 11(7x3) or Fig. 12(6x4).
2. If a bezel is being used, place the light into the bezel.
3. Place the gasket on the back of the light and bezel (if
used)
NOTE: Horizontal and vertical orientations indicated on
gasket for proper seal.
4. Insert the (4) supplied screws into each screw hole in the
light.
5. Place (4) flat washers over the screws on the back of the
light.
6. Screw onto each fastener the (4) well nuts onto the back of
the light. Tighten until snug.
7. Pull the wire harness through the opening and plug into
the back of the light.
8. With the light assembly in hand, insert the well nuts into
the (4) drilled holes. Fully seat to mounting surface.
9. Secure the light to mounting surface. While applying pres-
sure on each fastener, tighten the (4) screws 7 full turns.
NOTE: Tighten until gasket is compressed. DO NOT over tighten.
10. Insert (4) Silicone Plugs into the light to seal screw holes. (Use
a 50% Isopropyl alcohol, 50% deionized water mix for lubrica-
tion if necessary).
NOTE: Bezel required for any mounting not protected by inten-
tionally recessed designed mounting locations.
DO NOT USE POWER DRIVER.

1.800.338.7337 / www.soundosignal.com
87X3 / 6X4 Silicone_BACKUP
00KPJL 0822 REV B
WINDOW
TAB RETAINER
LOCKING ARM
FULLY SEATED RETENTION CLIP
FIG. 13
FIG. 15 FIG. 16
FIG. 14
NOTE: In the event the harness needs to be disengaged from the light, these instructions can be used to
reattach and apply the retention clip.
1. Plug harness into light housing, aligning tab to window, as shown in Fig 13.
2. Install the retainer clip over harness/light interface, inserting retainer into window, as shown in Fig. 14.
3. Press retainer clip's locking arm to snap closed.
RETENTION CLIP INSTRUCTIONS:
Other manuals for Mpower EMPSC07M Series
4
This manual suits for next models
1
Table of contents
Other Soundoff Signal Rack & Stand manuals

Soundoff Signal
Soundoff Signal PINNACLE EPL7PD C Series User manual

Soundoff Signal
Soundoff Signal Pinnacle EPL71PD Series User manual

Soundoff Signal
Soundoff Signal nFORCE ENFSSS**-Single Series User manual

Soundoff Signal
Soundoff Signal ETSSLFVBK10 User manual

Soundoff Signal
Soundoff Signal Mpower EMPSC07M Series User manual

Soundoff Signal
Soundoff Signal PINNACLE EPL71M+ Series User manual

Soundoff Signal
Soundoff Signal ETSSVBK02 User manual

Soundoff Signal
Soundoff Signal ETSSVBK05 User manual

Soundoff Signal
Soundoff Signal Mpower EMPSC07M Series User manual

Soundoff Signal
Soundoff Signal ETSS100BKUV-X User manual