JUMPER SETTINGS
C
c
F
FOR HOME OR OFFICE USE
Tested to Comply
with FCC Standards
Battery Stat P/N S1-THEU21P7S
4Z95
P/N 88-590
Rev. 1
TEST OPERATION
On the thermostat, use the MODE button to
place the thermostat into the OFF mode.
On the thermostat, use the MODE button to
place the thermostat into the COOL mode.
Press the FAN button to display the Fan On icon.
The fan should turn on and run continuously.
On the thermostat, use the MODE button to
place the thermostat into the HEAT mode.
Note: You may need to wait up to five minutes for
heating to energize due to the compressor lockout
feature.
If your HVAC unit is equipped with 2nd stage strip
heat, press the WARMER button once. 2nd stage
heating (W2) should energize.
Note: You may need to wait up to five minutes for
cooling to energize due to the compressor lockout
feature.
TROUBLE SHOOTING
SYMPTOM: The Cooling does not attempt to
turn on.
CAUSE: The cooling setpoint is set too high
or the thermostat is not in the Cool mode.
section in the Owner’s Manual to:
Lower the cooling setpoint
Place the thermostat into the Cool mode
SYMPTOM: The Heating does not attempt to
turn on.
CAUSE: The heating setpoint is set too low
or the thermostat is not in the Heat mode.
section in this manual to:
Raise the heating setpoint
Place the thermostat into the Heat mode
REMEDY: Consult the Normal Operation
REMEDY: Consult the Normal Operation
GAS FURNACE w/ ELECTRIC COOL
With Demand
Cooling Mode
Heating Mode
Y, G
W1, W2*, (G)**
*W2 will only be active during 2nd stage heating.
**In this application 24v will not be present at the
‘G’ terminal as the fan will be controlled by the
Gas Furnace.
With Demand
Cooling Mode
Heating Mode
Y, G, O
Y, G, W2*
HEAT PUMP w/ O REVERSING VALVE
*W2 will only be active during 2nd stage heating.
With Demand
Cooling Mode
Heating Mode
Y, G
Y, G, B, W2*
HEAT PUMP w/ B REVERSING VALVE
*W2 will only be active during 2nd stage heating.
ELECTRIC STRIP HEAT w/ ELECTRIC COOL
With Demand
Cooling Mode
Heating Mode
Y, G
W1, G, W2*
*W2 will only be active during 2nd stage heating.
GAS
GAS
JP 1
JP 2
JP 3
ELEC
GAS
JP 1
JP 2
JP 3
HP
O
ELEC
JP 1
JP 2
JP 3
GAS
GAS
B
JP 1
JP 2
JP 3
HP
B
ELEC
GAS
GAS
O
ELEC
HP
O
B
O
B
HP
GAS
Model
S1-THEU21P7S
MODE
I n s t a l l a t i o n I n s t r u c t i o n s
I n s t a l l a t i o n I n s t r u c t i o n s
7 Da y
Pr o gr a m ma b le
7 Da y
Pr o gr a m ma b le
HVAC SERVICE PARTSTM
Press the COOLER or WARMER button until the
set temperature is 10 degrees above room
temperature. The HVAC unit should energize in
the heating mode and the Heat icon should blink.
Press the COOLER or WARMER button until the
set temperature is 10 degrees below room temp.
The HVAC unit should energize in the cooling
mode and the Cool icon should blink.