EMERGENCY SWITCHES
More information on www.spamel.eu 29-8-2018
Technical data
Rated insulation voltage Ui500 V
Rated continuous current Iu=Ith 10 A
Rated operational current
Iefor AC-15
2.5 A (230 V)
1.6 A (400/500 V)
Rated operational current
Iefor AC-13
4 A (24 V)
1 A (110 V)
0.25 A (220 V)
Protection level IP65 – declared by the manufacturer
(the selected feature of the product was
not confirmed by CNBOP-PIB)
OP1 is properly protected against
water according to the standard:
PN-EN60068-2-30
Wire gauge 2× 1...2.5 mm² (solid)
0.75...1.5 mm² (stranded)
Manual call point OP1
Ordering code
OP1- - \
Hammer
without hammer
-M with hammer
Signalling
without signalling
-24 with signalling LED 24V AC/DC
-230 with signalling LED 230V AC
-P24 with PULSATING LED 24V DC
(pulsating frequency 2 Hz)
Switches
10, 20, 30
01, 02, 03
11, 12
21
Pushbutton type
Atriggered automatically after breaking the glass
Bafter breaking the glass press the button manually
Version
W01 surface mounting
W02 flush
Code examples
OP1-W01-A-11
on-plaster mounting, 1 NO switch and 1 NC switch. When the glass is broken the pushbutton is
released automatically (type A acc. to PN-EN 54-11)
OP1-W02-B-10-230-M
flush mounting with 1 NO switch. When the glass is broken it is necessary to push the button
(type B acc. to PN-EN 54-11). Signalling LED 230 V AC. With a hammer.
Product description
Manual call point (OP1) is intended for use in industry buildings and public
places. It is offered in two versions: flush and surface mounted. Each version
is available in two types: A and B. In OP1 type A the switch is released after
breaking the glass in an emergency. In OP1 type B, after breaking the glass the
momentary pushbutton must be pressed. Each enclosure can be fitted with
three switches SP22-10 (NO) or SP22-01 (NC). In addition, each assembly can
be fitted with a diode which can be connected to the switch or directly to the
alarm system in the building.
The signal is triggered and sent after breaking the glass (type A) or after breaking
the glass and pressing the momentary pushbutton (type B). The alarm signal is
reset after replacing the breakable element (glass - ordering code PPOŻ-5701).
The product is compliant with PN-EN 54-11.
Approval certificate No. 2266/2014.
Certificate of compliance EC No. 1438/CPD/0130.
Accessories
Hammer with a holder PPOŻ-1200\P01
Glass PPOŻ-5701\P01
Normally closed switch SP22\10
Normally closed switch ST22\01
Resistor board
Front panel label
Note
The type (A or B) must be taken into account when choosing the circuits
TYPE A
Normally open: the circuit is closed when the cover with a glass is mounted
- the button is pressed.
the circuit is open when the cover with a glass is not mounted or the glass is
broken - the button is not pressed.
Normally closed: opening and closing are opposite to the normally open
circuit
TYPE B
Normally open: closed state (closed circuit) is when the button is pressed.
Before that the cover with a glass must be disassembled or the glass broken
and the button must be pressed.
open state (open circuit) is when the cover with a glass is mounted or not
mounted or the glass is broken but the button is not pressed.
Normally closed: opening and closing are opposite to the normally open
circuit
Emergency switches
EMERGENCY SWITCHES
More information on www.spamel.eu 29-8-2018

113
59
35
flush mounting
Dimensions

113
30
52
Spacing of xing holes
68
Space for a gland
surface mounting
Emergency switches

Popular Switch manuals by other brands

Eaton LSE-11 Original operating instructions

Eaton

Eaton LSE-11 Original operating instructions

NEC SigmaBlade N8406-022 user guide

NEC

NEC SigmaBlade N8406-022 user guide

Vimar 01798 manual

Vimar

Vimar 01798 manual

Extron electronics MMX 62 AV RCA Specification sheet

Extron electronics

Extron electronics MMX 62 AV RCA Specification sheet

gofanco Prophecy PRO-KVMDP-4P user guide

gofanco

gofanco Prophecy PRO-KVMDP-4P user guide

Altimium TP70WPB2HU-EU user manual

Altimium

Altimium TP70WPB2HU-EU user manual

Allied Telesis x600-48Ts installation guide

Allied Telesis

Allied Telesis x600-48Ts installation guide

J & V Technology JSVER-HB3022 user manual

J & V Technology

J & V Technology JSVER-HB3022 user manual

schmersal AZ 200 T operating instructions

schmersal

schmersal AZ 200 T operating instructions

SIIG CE-KV0G11-S1 user manual

SIIG

SIIG CE-KV0G11-S1 user manual

NETGEAR ProSafe GS700TS Hardware installation guide

NETGEAR

NETGEAR ProSafe GS700TS Hardware installation guide

Tektronix WVR4000 Service manual

Tektronix

Tektronix WVR4000 Service manual

Kramer VP-23DS user manual

Kramer

Kramer VP-23DS user manual

NoiseKen ISS-7650 instruction manual

NoiseKen

NoiseKen ISS-7650 instruction manual

Woxcon SCU41E-VC user manual

Woxcon

Woxcon SCU41E-VC user manual

Siemens RUGGEDCOM RST2228 installation guide

Siemens

Siemens RUGGEDCOM RST2228 installation guide

Cabletron Systems 9E133-36 user guide

Cabletron Systems

Cabletron Systems 9E133-36 user guide

schmersal AZM300B-I1-ST1P2P-A-T instructions

schmersal

schmersal AZM300B-I1-ST1P2P-A-T instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.