Vimar 01798 User manual

Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com
01798 EN 01 2301
01798
SMART SWITCH
EnOcean actuator with 2 relay outputs NO 5 A 230 V~, 2 programmable inputs
with 1-way switch function for local control, 230 V~ 50/60 Hz power supply.
The actuator with EnOcean module is designed to receive the radio control from the radio
frequency rocker button to actuate the connected loads via the relay outputs. It can also be
connected to two 1-way switches/push buttons to control loads also locally. With its compact
dimensions, the actuator can be installed anywhere on the wall (retrofit inside of the flush
mounting box) or on the ceiling (false ceiling, etc.).
In the event of a power failure, once the mains power supply is restored, the actuator
keeps the previous configuration.
TECHNICAL CHARACTERISTICS.
• Power supply: 230 V~, 50 Hz.
• Switching capacity: 230 V~ - 5 A
• Self-consumption: <1W
• Frequency range: 868.3 MHz
• Frequency band occupied: from 868.0 to 868.6 Mhz
• Max. RF power: +3dBm
• Range: up to 30 metres
• Possibility of connecting two 1-way switches/push buttons
• Operating temperature: 0 - 35 °C
• Maximum number of radio transmitters that can be stored: 22
• RGB LED for signalling the various configuration phases
• EEP (Profile EnOcean®): D2-01-12
• Dimensions: 40 mm x 44 mm x 16.9 mm
• Weight: 34 g
CONTROLLABLE LOADS.
• For each relay output:
- resistive loads
: 5 A (20.000 cycles);
- incandescent lamps : 5 A (20.000 cycles);
- fluorescent lamps : 50 W (20.000 cycles);
- LED lamps: 50 W (20.000 cycles).
INSTALLATION.
•Installation of two 1-way switches/push buttons and 2 lamps. By default all wired 1-way
switches connected to the actuator work as “switch” (“two-way switch”) with EnOcean®
transmitters associated with the device.
•Identification of configuration of both 1-way switches/push buttons. When powering up the
actuator after configuration, press the 1-way switch it is connected to only once. An automatic
identification procedure will be run to identify if a one-position stable or two-position stable
1-way switch is being used.
Note 1: The same configuration applies to both 1-way switch/push button 1 and 1-way switch/
push button 2. The devices connected to actuator 01798 must be the same type (in other
words two one-way switches or two push buttons and never one one-way switch and one
push button). To run the automatic identification again manually reset the device.
Note 2: When using radio controls, we recommend you use the device only with the push
buttons and not with the 1-way switches.
CONFIGURATION.
ACTUATOR OPERATING MODES
•LOCAL CONTROL. It is possible to switch the device on or off locally with a short press of
the CONF push button. This switches both outputs at the same time. Alternatively, operate
the switches/push buttons connected to the device to turn the light on/off on CHANNEL 1 or
2.
•ASSOCIATION. Two procedures are available (1 or 2) to access association mode; for both,
one of the two channels available is associated at a time. The actuator must be powered and
the lights off.
CHANNEL 1 ASSOCIATION
1.Using the actuator: press the CONF button three times (in less than 1 s).
2. Using the wired 1-way switches/push buttons: press the CHANNEL 1 1-way switch/push
button 3 times (in less than 1 s).
The LED flashes red and the light relating to 1-way switch/push button 1 flashes to indicate
that CHANNEL 1 is in association/disassociation mode; quickly (< 1 s) press the button you
wish to associate, which will control light 1, within 30 s.
CHANNEL 2 ASSOCIATION
1. Using the actuator: press the CONF button three times (in less than 1 s); wait 1 s and press
the CONF button again.
2. Using the wired switches/push buttons: Press the CHANNEL 2 1-way switch/push button
3 times (in less than 1 second).
The LED flashes red and the light relating to 1-way switch/push button 2 flashes to indicate
that CHANNEL 2 is in association/disassociation mode; quickly (< 1 s) press the button you
wish to associate, which will control light 2, within 30 s.
To associate a transmitter, see paragraph Procedure for association as receiver; the LED
lights up in green to confirm the association procedure. If during the “Association mode” the
LED flashes orange it means that the actuator memory is full or that, during the procedure, no
transmitter has been associated. If the memory is full delete a transmitter and then associate
the new one.
•LED INDICATIONS DURING “LEARNING MODE”.
“Learning mode” PHASES LED INDICATORS
Access to “Learning mode” 1 GREEN flash then turns to RED
Device enrolled 2 GREEN flashes
Deletion of enrolled device 2 RED flashes
Interruption of “Learning mode” 2 RED flashes
Error during “Learning mode” 2 RED flashes
Memory full (22 devices exceeded) 2 ORANGE flashes
“Learning mode” time-out 2 ORANGE flashes
•DEVICE RESET. Press CONF for more than 5 s until the LED turn on orange; when the
button is released the LED remains on and you are in “Reset Mode”. Press CONF once to
reset; the LED flashes red and green to confirm the operation. In “Reset Mode” the button
must be pressed within 30 s after which, if no operations are performed, the LED stops
flashing and no reset is run.
PROCEDURE FOR ASSOCIATION AS RECEIVER.
•EnOcean® Switch, Type “rocker button control” (EEP: F6-02-01).
To associate this transmitter to the actuator proceed as follows:
1. Activate the “Association mode” on the device.
2. Press any button on the radio control. The button pressed during the association process
is the one that activates the selected channel while the other button switches off the selected
channel. For example:
Association
mode Use
Associated button
during the
“Association
mode”
Button pressed
on the
transmitter
State of
actuator
01798
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Repeat the procedure for both channels.
To delete the association of a transmitter, activate “Association mode” on the related channel
(1 or 2) and press any button on the transmitter; the device will no longer be able to control
the selected channel of the actuator 01798. To delete both channels, repeat the procedure
for each one.
PROCEDURE FOR ASSOCIATION AS TRANSMITTER.
When the switches are connected to inputs P1 and/or P2 they can operate as EnOcean®
transmitters; once configured, via actuator 01798, they can control any other EnOcean®-
compatible receiver.
To associate actuator 01798 to another receiver proceed as follows:
1. Activate the “Association mode” on the receiver.
2. Press the button on the connected switch to be associated to the receiver once.
At the end of the association procedure, the state (ON or OFF) of the output on actuator 01798
determines the “ON” state of the associated receiver.
Example.
If you want the receiver to be synchronised with the actuator, associate the button by moving
the output to ON; vice versa, if you don't want the receiver to be synchronised, associate the
button by switching the output to OFF.
To delete the association of actuator 01798 from another receiver activate the “Association
mode” on the receiver and press the button on the switch associated to the receiver once.
SUPPORTED PROFILES (EEP)
F6-02-01 F6-04-01 F6-10-00 D5-00-01 A5-07-01
A5-07-02 A5-07-03 A5-08-01 A5-08-02 A5-08-03
A5-10-19 A5-10-18 A5-10-1A A5-10-1B A5-10-1C
A5-10-1D A5-10-01 A5-10-05 A5-10-08 A5-10-0C
A5-10-10 A5-10-13 A5-10-16 A5-10-17 A5-10-0A
A5-10-0B A5-14-01 A5-14-02 A5-14-03 A5-14-04
A
B
Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com
01798 EN 01 2301
01798
SMART SWITCH
FRONT VIEW
CONNECTION EXAMPLE
LED: Configuration LED
CONF: Configuration button
N: Neutral
L: Phase
P1: Switch input 1
P2: Switch input 2
1: Relay output 1
2: Relay output 2
Caution: Each terminal can house only one cable with max. section 2.5mm
2
.
INSTALLATION DIAGRAM FOR 2 1-WAY SWITCHES/PUSH BUTTONS AND 2 LAMPS
CONF.
N L P1 P2 1 2
5A 230~ 50/60Hz
2IN/2OUT
01798
2IN/2OUT
CONF.
N L P1 P2 1 2
5A 230~ 50/60Hz
2IN/2OUT
01798
2IN/2OUT
L
N
INSTALLATION EXAMPLES
1.
2.
CONF.
50/60Hz
01798
5A 230V~
N L P1 P2 1 2
2IN/2OUT
2IN/2OUT
2160.2
CONF.
50/60Hz
01798
5A 230V~
NLP1 P2 1 2
2IN/2OUT
2IN/2OUT
INSTALLATION RULES.
• Installation must be carried out by qualified persons in compliance with the current regula-
tions regarding the installation of electrical equipment in the country where the products are
installed.
• During product installation the supply voltage MUST BE DISCONNECTED. Disconnect
directly at the main switch.
• Consider that the LED will always be green when the device is on. Remember to switch off
the supply voltage (green LED off) before modifying the connections in any way.
REGULATORY COMPLIANCE.
RED Directive. Standards EN 60669-2-1, EN 300 220-2, EN 301 489-3, EN 62479.
Vimar SpA declares that the radio equipment complies with Directive 2014/53/EU. The full text
of the EU declaration of conformity is on the product sheet available on the following website:
www.vimar.com
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the product must not be included
with other general waste at the end of its working life. The user must take the worn product to a sorted waste center, or
return it to the retailer when purchasing a new one. Products for disposal can be consigned free of charge (without any
new purchase obligation) to retailers with a sales area of at least 400 m2, if they measure less than 25 cm. An efficient
sorted waste collection for the environmentally friendly disposal of the used device, or its subsequent recycling, helps
avoid the potential negative effects on the environment and people’s health, and encourages the re-use and/or recycling
of the construction materials.

Other Vimar Switch manuals

Vimar Elvox 69AM/T User manual

Vimar

Vimar Elvox 69AM/T User manual

Vimar ELVOX EZP07.GA User manual

Vimar

Vimar ELVOX EZP07.GA User manual

Vimar Elvox 3530 Assembly instructions

Vimar

Vimar Elvox 3530 Assembly instructions

Vimar Well-contact Plus User manual

Vimar

Vimar Well-contact Plus User manual

Vimar 03906 User manual

Vimar

Vimar 03906 User manual

Vimar by-me Eikon User manual

Vimar

Vimar by-me Eikon User manual

Vimar EIKON 20181 User manual

Vimar

Vimar EIKON 20181 User manual

Vimar 01796.2 User manual

Vimar

Vimar 01796.2 User manual

Vimar Eikon 20196 User manual

Vimar

Vimar Eikon 20196 User manual

Vimar Eikon User manual

Vimar

Vimar Eikon User manual

Vimar 01796.2 User manual

Vimar

Vimar 01796.2 User manual

Vimar ELVOX 935A User manual

Vimar

Vimar ELVOX 935A User manual

Vimar Eikon TACTIL 21134 User manual

Vimar

Vimar Eikon TACTIL 21134 User manual

Vimar by-me Eikon Evo 21588 User manual

Vimar

Vimar by-me Eikon Evo 21588 User manual

Vimar Eikon TACTIL 21174 User manual

Vimar

Vimar Eikon TACTIL 21174 User manual

Vimar Eikon 20592.0 User manual

Vimar

Vimar Eikon 20592.0 User manual

Vimar Eikon User manual

Vimar

Vimar Eikon User manual

Vimar 03905 User manual

Vimar

Vimar 03905 User manual

Vimar LINEA 30504 User manual

Vimar

Vimar LINEA 30504 User manual

Vimar LINEA 30196 Series User manual

Vimar

Vimar LINEA 30196 Series User manual

Vimar Eikon TACTIL 21119 User manual

Vimar

Vimar Eikon TACTIL 21119 User manual

Vimar Arke Series Instruction manual

Vimar

Vimar Arke Series Instruction manual

Vimar Eikon User manual

Vimar

Vimar Eikon User manual

Vimar 46260.5P.01 User manual

Vimar

Vimar 46260.5P.01 User manual

Popular Switch manuals by other brands

Steren USB-527 instruction manual

Steren

Steren USB-527 instruction manual

SMC Networks ZSE30 Series manual

SMC Networks

SMC Networks ZSE30 Series manual

Veracity CAMSWITCH VCS-4P1-Mob quick start guide

Veracity

Veracity CAMSWITCH VCS-4P1-Mob quick start guide

OATI MyGrid Switch user guide

OATI

OATI MyGrid Switch user guide

GE GE-DSG-244 Installation sheet

GE

GE GE-DSG-244 Installation sheet

Allied Telesis CentreCOM GS970EMX Series installation guide

Allied Telesis

Allied Telesis CentreCOM GS970EMX Series installation guide

Extreme Networks BlackDiamond X8 Series Hardware installation manual

Extreme Networks

Extreme Networks BlackDiamond X8 Series Hardware installation manual

HK Instruments PS Series installation instructions

HK Instruments

HK Instruments PS Series installation instructions

EG Juniper EX manual

EG

EG Juniper EX manual

Link electronics 861-XL1616F Specification sheet

Link electronics

Link electronics 861-XL1616F Specification sheet

KBC ESUL8-D Series quick start guide

KBC

KBC ESUL8-D Series quick start guide

Captron SENSORswitch CHT3-F Series Configuration

Captron

Captron SENSORswitch CHT3-F Series Configuration

Dell PowerConnect W-IAP175P reference guide

Dell

Dell PowerConnect W-IAP175P reference guide

Zwave Minoston MS13ZS manual

Zwave

Zwave Minoston MS13ZS manual

GORMAN-RUPP PUMPS EPS 2000 Operation manual

GORMAN-RUPP PUMPS

GORMAN-RUPP PUMPS EPS 2000 Operation manual

HP ProCurve 1600M Security guide

HP

HP ProCurve 1600M Security guide

ZyXEL Communications XGS3600 Series manual

ZyXEL Communications

ZyXEL Communications XGS3600 Series manual

Juniper EX 3200 quick start

Juniper

Juniper EX 3200 quick start

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.