SPARENERGO SE5000U User manual

User Manual
SE5000U (15S 48V-4.8Kwh /16S 51.2V-5.12Kwh)
SE7000U (15S 48V-7.2Kwh / 16S 51.2V-7.68Kwh)
SE10000U (15S 48V-9.6Kwh / 16S 51.2V-10.24Kwh)
For On / Off Hybrid Solar Storage System

Version: 1.0
Contents
1. Safety Pre autions.............................................................................................................................................. - 2 -
1.1. Before Conne ting .................................................................................................................................................. - 2 -
1.2. During operation .................................................................................................................................................... - 2 -
2. Battery Spe ifi ations
................................................................................................................................................... - 3 -
3. Introdu tion to the battery
.......................................................................................................................................... - 5 -
3.1. Key Features ........................................................................................................................................................... - 5 -
3.2. Interfa e Introdu tion ............................................................................................................................................. - 5 -
3.3. SOC Indi ator & Status Indi ator Guides.............................................................................................................. - 6 -
3.4. Conne tors.............................................................................................................................................................. - 7 -
3.5. Wake Up button........................................................................................................................................................ - 7 -
3.6. Display fun tion instru tion ..................................................................................................................................... - 7 -
3.6.1. Referen e of real figure
................................................................................................................................. - 7 -
3.6.2. S reen Display
.............................................................................................................................................. - 8 -
3.6.3. Fun tional Spe ifi ations
............................................................................................................................. - 8 -
4. Safe handling guide
.................................................................................................................................................. - 10 -
4.1. System Diagram .................................................................................................................................................... - 10 -
4.2. Tools....................................................................................................................................................................... - 10 -
4.3. Safety Gear............................................................................................................................................................. - 11 -
5. Installation
................................................................................................................................................................ - 11 -
5.1. Inventory of items ................................................................................................................................................... - 11 -
5.2. Installation Lo ation ............................................................................................................................................... - 11 -
5.2.1. Minimum learan es
.................................................................................................................................. - 12 -
5.3. Installing the Battery Pa k...................................................................................................................................... - 13 -
5.3.1. Mounting to a wall
....................................................................................................................................... - 13 -
5.4. Parallel use of battery ........................................................................................................................................... - 14 -
5.4.1. Parallel use of battery ( All off grid solar inverters )........................................................................................ - 14 -
5.4.2. Parallel use of SL battery on Canbus /RS485( All hybrid on-off grid solar inverters) ............................... - 16 -
5.4.3. ADS guide Line ............................................................................................................................................... - 17 -
6. Produ t Warranty
...................................................................................................................................................... - 24 -
6.1. ................................................................................................................................................................................ - 24 -
6.2. ................................................................................................................................................................................ - 24 -
6.3. ................................................................................................................................................................................ - 24 -
6.4. Fa tory Warranty S ope ....................................................................................................................................... - 24 -
6.5. Warranty onditions............................................................................................................................................... - 24 -

1.
Safety Pre autions
•It is very important and ne essary to read the user manual arefully before installing or using the
battery. Failure to follow any of the instru tions or warnings in this do ument an result in
ele tri al sho k, serious injury, death, or may damage the battery and the whole system.
•If the battery is stored for a prolonged time, it is requirement that they are harged every three to
six months, and the SOC should be no less than 80%.
•The battery needs to be re harged within 12 hours, after fully dis harging.
•Do not expose able outside.
•All battery terminals must be dis onne ted before maintenan e.
•Do not use leaning solvents to lean the battery.
•Do not expose the battery to flammable or harsh hemi als or vapors.
•Do not paint any part of the battery, in lude any internal or external omponents.
•Do not onne t battery with PV solar wiring dire tly.
•Any foreign obje t is prohibited to be inserted into any part of the battery.
•Any warranty laims are ex luded for dire t or indire t damage due to items above.
1.1.
Before Conne ting
•After unpa king, please he k the battery and pa king list first, if the battery is damaged or spare
parts are missing, Please onta t the dealer.
•Before installation, be sure to ut off the grid power and make sure the battery is in the turned-off
mode;
•Wiring must be orre t, do not mix- onne t the positive and negative ables, and ensure no short
ir uit with the external devi e;
•It is prohibited to onne t the battery with AC power dire tly;
•The embedded BMS in the battery is designed for 48VDC, please DO NOT onne t battery in
series;
•It is prohibited to onne t the battery with different type of battery;
•Please ensure the ele tri al parameters of battery system are ompatible to inverter;
•Keep the battery away from fire or water.
1.2.
During operation
•If the battery system needs to be moved or repaired, the power must be ut off first and the
battery is ompletely shutdown;
•It is prohibited to onne t the battery with different type of battery;
•It is prohibited to put the batteries working with faulty or in ompatible inverter;
•In ase of fire, only dry powder fire extinguisher an be used, liquid fire extinguishers are
prohibited;
•Please do not open, repair or disassemble the battery. We do not undertake any onsequen es or
related responsibility due to violation of safety operation or violating of design, produ tion and
equipment safety standards.

2.
Battery Spe ifi ations
Battery Spe ifi ations
Model No
SE-5000U/15S SE-7000U/15S SE-10000U/15S
Nominal Parameters
Voltage
48 V 48 V 48 V
Capa ity
100Ah 150Ah 200Ah
Energy
4.8 KwH 7.2 KwH 9.6 KwH
Dimensions (L x W x H)
680 x480 x180(220)mm 680 x480 x180(220)mm 680x480x180(220)mm
Weight
58.5kg 75.0 kg 96.5kg
Basic Parameters
Life time(25°C)
20 years
Life y les(80% DOD, 25°C)
6000 Cy les
Storage time / temperature
5 months @ 25°C; 3 months @ 35°C; 1 month @
45°C
Operation temperature
-20°C to 60°C @60+/-25% Relative Humidity
Storage temperature
0°C to 45°C @60+/-25% Relative Humidity
Lithium Battery Standard
IEC62619,UN38.3,ROHS,CE-
EMC,UL1642,MSDS
En losure prote tion rating
IP21
Ele tri al Parameters
Operation voltage
48 Vd 48
Vd
48 Vd
Max. harging voltage
54 Vd 54
Vd
54 Vd
Cut-off Dis harge Voltage
42 Vd 42
Vd
42 Vd
Max. harging and
dis harging urrent
100A(4800W) 120A(5760W) 120A(5760W)

Battery Spe ifi ations
Model No
SE-5000U/16S SE-7000U/16S SE-10000U/16S
Nominal Parameters
Voltage
51.2V 51.2V 51.2V
Capa ity
100Ah 150Ah 200Ah
Energy
5.12KwH 7.68KwH 10.24KwH
Dimensions (L x W x H)
680 x480 x180(220)mm 680 x480 x180(220)mm 680x480x180(220)mm
Weight
60.50kg 78.0 kg 105.5kg
Basic Parameters
Life time(25°C)
20 years
Life y les(80% DOD, 25°C)
6000 Cy les
Storage time / temperature
5 months @ 25°C; 3 months @ 35°C; 1 month @
45°C
Operation temperature
-20°C to 60°C @60+/-25% Relative Humidity
Storage temperature
0°C to 45°C @60+/-25% Relative Humidity
Lithium Battery Standard
IEC62619,UN38.3,ROHS,CE-
EMC,UL1642,MSDS
En losure prote tion rating
IP21
Ele tri al Parameters
Operation voltage
51.2 Vd 51.2 Vd 51.2 Vd
Max. harging voltage
58 Vd 58 Vd 58 Vd
Cut-off Dis harge Voltage
44 Vd 44 V d 44 Vd
Max. harging and
dis harging
urrent
100A(5120W) 120A(6144W) 120A(6144W)

3.
Introdu tion to the battery
3.1.
Key Features
•LiFePO4 omposition – provides ex eptional safety and longevity
•High safety and reliability
•6,000 y les/20 year servi e life
•Consistent performan e over wide temperature range
•Wall-mounted, onvenient installation
•Integrated state-of-the-art BMS to manage and monitor battery information in luding voltage,
urrent and temperature as well as balan e ell harging/dis harging rates
•5-10years warranty
3.2.
Interfa e Introdu tion
•This se tion details the interfa e fun tions of front and ba k panel..
•Front interfa e:
•No. •Des ription •Silk-s reen •Remark
•1-2 •UES0600 •P+ P+ •Output terminal
•3-4 •UES0600 •P- P- •Output terminal
•
5
•Dial swit h •ADS •Set the address
•
6
•Canbus •Canbus •Canbus ommuni ation port

•
7
•RS485 port •RS485 •RS485 ommuni ation port
•
8
•port Reset button •RST •For reset the batter
•
9
•Battery Swit h •On/Off •Turn On/Off
•10 •LED •CAPACITY •Capa ity indi ator
•11 •LED •ALM •Alarm indi ator
•12 •LED •RUN •Operation indi ator
•13 •LCD
• •
•14 •LCD Key
• •
•15 •Handle
• •
•16 •Bra ket
• •

3.3.
SOC Indi ator & Status Indi ator Guides
•Chart 1: Battery Status
Normal/
RUN
ALM Capa ity LED
Status
Warning/
Prote tion
Description
Shut
Down
Shut down OFF OFF OFF OFF OFF OFF All OFF
Standby
Normal Flash OFF OFF OFF OFF OFF Standby
Charge
Normal ON OFF
Based on apa ity
Warning ON Flash
Prote tion ON ON
Dis harge
Normal ON OFF Based on apa ity
Warning ON Flash
Prote tion OFF ON OFF OFF OFF OFF UVP, OCP…
Fault
Prote tion OFF ON OFF OFF OFF OFF Stop harging
or dis harging

•Chart 2: Battery Capa ity
Status Charging
Dis harging
Capa ity LED Indi ator
~
L4 L3 L2 L1 L4 L3 L2 L1
Capa ity
0 25%
~
OFF OFF OFF Flash OFF OFF OFF NO
25 50%
~
OFF OFF Flash ON OFF OFF NO NO
50 75%
~
OFF Flash ON ON OFF NO NO NO
75 100% Flash ON ON ON NO NO NO NO
RUN Status
NO Flash
3.4.
Conne tors
Charge / Dis harge onne tors: to onne t the positive pole (+) and negative pole (-) from the battery
to the inverter via DC isolator.
Canbus/ RS485: A tive ommuni ation portal between battery and inverter.
USB To RS232: to get dynami monitoring data of the battery from upper omputer.
Address: Reserved Address portal for multiple parallel onne tions.
3.5.
Wake Up button
•Battery On: When battery is shut down, press this RST button for 3 se onds. It is a tivated
when the LED lights fli ker from RUN light to the lowest apa ity indi ator.
•Battery off: When battery is a tivated, press this button for 3 se onds. It will be shut down
when the LED lights fli ker from lowest apa ity indi ator to RUN light.
3.6.
Display fun tion instru tion
3.6.1.
Referen e of real figure

3.6.2.
S reen Display
3.6.3.
Fun tional Spe ifi ations
•Interfa e introdu tion
•Main menu page
•Ele tri ity/dorman y a tivated, will show the wel ome s reen, press the MENU button to enter
the main menu page. As shown in the figure below:
•Battery parameters olle tion page
When the ursor“》”is point to “Battery Parameters A quisition”,press ENTER key will enter
into the page of“Battery Parameters A quisition”,As shown in the figure below:

•Battery status page
When the ursor “》”is point to “Battery Status”,press ENTER key will enter into the page of
“Battery Status”,As shown in the figure below:
•Parameter Settings
S reen an not set up parameters
•System Settings Page
Baud Rate:9600 do not set

•Key des ription
1) SW1----NEMU,SW2----ENTER,SW3----UP,SW4----DOWN, SW5-----ESC.
2) Ea h item is “》”or“--”as a beginning,among them“》”shows the urrent ursor position,
press UP or DOWN key an move the ursor position;with“ 》 ”end of the proje t,the
ontent of the said proje t has not shown, press ENTER key an enter the orresponding
page.
3) Press ESC key an be returned at the next higher level dire tory;In any position, press
NEMU key an return to the main menu page.
4) In a dormant state, press any key, an a tivate the s reen.
•Dorman y/shutdown
Under normal operation ondition, with no keystrokes 1 minutes later, system will enter a
state of dorman y/shutdown.
Shutdown/dorman y state,press any key,s reen an be a tivated.
4.
Safe handli
ng
guide
4.1.
System Diagram
4.2.
Tools
The following tools are required to install the battery pack:
•Wire utter
•Crimping Modular Plier
•S rew Driver
NOTE
•Use properly insulated tools to prevent a idental ele tri sho k or short ir uits.
•If insulated tools are not available, over the entire exposed metal surfa es of the available
tools, ex ept their tips, with ele tri al tape.

4.3.
Safety Gear
It is re ommended to wear the following safety gear when dealing with the battery pa k:
•Insulated gloves
•Safety goggles
•Safety shoes
5.
Installation
5.1.
Inventory of items
Thoroughly inspe t the pa kaging upon re eipt of goods. If there is any item missing or if there is any
damage to the external pa kaging or to the unit itself upon unpa king, please onta t us immediately.
A B C D E
NO.
Item Quantity
Spe ifi ation
A
Battery Pa k
1
4.8/7.2 / 9.6 KWh
B
Mounting frame
1
SPCC
C
Mounting frame s rew 12 M8*60mm
D
Power Cable( 1.0 M )
2
25M2 Wire - M6 125A/1000V
E
Instru tion manual/Warranty Card
1
This do ument
Option
Parallel Power able (1.0 M)
2
125A/1000V
Option
Parallel om able (1.0 M )
1
RJ45
5.2.
Installation Lo ation
Make sure that the installation lo ation meets the following onditions:
•The installation site must be suitable for the size and weight of the battery.
•Must be installed on a firm surfa e to sustain the weight of battery.
•The area is water proof.
•There are no flammable or explosive materials in proximity
•The ambient temperature is within the range from 0°C to 45°C.
•The temperature and humidity is maintained at a onstant level.
•There is minimal dust and dirt in the area.
•Installation must be verti al or tilted ba kwards by maximum 15° - avoid forward or sidewaystilt.

5.2.1.
Minimum learan es
Observe the minimum learan es to walls, other batteries or obje ts as shown in the diagram and
pi ture below in order to guarantee suffi ient heat dissipation
Dire tion
Minimum learan e (mm)
Above 300
Below 300
Sides 500
Front 300

5.3.
Installing the Battery
Pa k
5.3.1.
Mounting to a
wall
1.Choose suitable firm wall with thi kness greater than 80mm.
2.Use the mounting frame as a template, mark the hole position.
3.Drill 8 holes a ording to the hole position, it is ø10 with depth 60mm.
4. Hammer the M8 s rews to the above holes, and s rew the nut. Note: Do not position s rews
flush to the wall - leave 10 to 20 mm exposed.
5.Fix the mounting frame to the 8 s rews.
6. Raise the battery a little higher than the mounting frame whilst maintaining the balan e of the
battery. Hang the battery on the frame through the mat h hooks.

5.4.
Parallel use of battery
5.4.1.
Parallel use of battery ( All off grid solar inverters )
GSL ENERGY powerwall battery is a smart battery to mat h all off grid solar inverter ( 48VDC) types.
When the battery needs to be used in parallel, the maximum onne tion is 14 units, but we re ommend 2-
4 units a ording to appli ation. When onne ting with off grid 48VDC solar inverters, it does not need
to add Canbus/RS485 ommuni ation ables with inverters, if inverter brand fa tory does not have
Canbus/RS485 port, just plug and play use.
NOTE: Parallel power able standard is 1 meter. This is not standard able in battery pa kage.
For parallel able quantity needed, please onsult with GSL ENERGY sales manager for
proper use and related quantity.
Two pcs connect diagram

Three pcs connect diagram
Four pcs connect diagram

Fourteen pcs connect diagram
5.4.2.
Parallel use of E battery on Canbus /R 485( All hybrid on-
off grid solar inverters)
When the battery needs to be used in parallel, the maximum onne tion is 15 units(Canbus), 14units
( RS485 ) with SE hybrid solar inverter, but we re ommend to use 2-4 units a ording to appli ation. The
appli ation needs power and ommuni ation onne tions as below, hoose suitable parallel power
ables and related onne tors.
NOTE: Parallel power standard is 1 meter. This is not standard able in battery pa kage.
For parallel able issue, please onsult related fa tory sales manager for proper use and related
quantity.

Canbus/RS485 Mat hed Hybrid Inverter brands
Brand Model No Com Port Cable
Supply
Appli ation Installation
DEYE Sun series
3.6K,5K,7.6K,8K
RS485 RJ45 On/off-Grid Wall-mounted
LUXPOWER LXP3.6K/4.6K/5K Hybrid
LXP 3600 ACS series
RS485 RJ45 On/off-Grid Wall-mounted
GROWATT SPF3000/SPA/SPH3000
3600/4000/4600/5000/6000
CAN RJ45 On/off-Grid Wall-mounted
SOFAR HYD3000-ES CAN RJ45 On/off-Grid Wall-mounted
GOODWE
GW3648D-ES/GW5048D-
ES/BP/SBP/EM
CAN RJ45 On/off-Grid Wall-mounted
GMDE Powervortex4600/5200TL CAN RJ45 On/off-Grid Wall-mounted
SOLIS RHI-3K/3.6K/5K-48ES CAN RJ45 On/off-Grid Wall-mounted
VICTRON Multiplus/Quattro 48 CAN RJ45 On/off-Grid Wall-mounted
IMEON IMEON3.6/9.12 CAN RJ45 On/off-Grid Wall-mounted
INFINI/Voltroni /Axpert
Infinisolar series
48V/Axpert series 48V
CAN RJ45 On/off-Grid Wall-mounted
SMA Sunny
Island4.4M/6.0H/8.0H
CAN RJ45 On/off-Grid Wall-mounted
SAJ ELECTRIC Sunfree 4K,5K series,
ACS3600
RS485 RJ45 On/off-Grid Wall-mounted
To be ontinued……..
5.4.3.
AD guide Line
If you start to onne t
GSL hybrid inverter
, make sure you should onsult with GSL sales
manager before onne tion. If the hybrid inverter is not from GSL fa tory brand, please spe ify
related hybrid on-off grid inverter brand with Sparenergo sales managers.

Canbus Version –Max 15 PCS
RS485 Version –Max 14 p s
This manual suits for next models
5
Table of contents
Popular Inverter manuals by other brands

Camp Power
Camp Power SIM-700 user manual

Mastervolt
Mastervolt WHISPER 6 ULTRA user manual

Cotek
Cotek S1500-112 user manual

National Instruments
National Instruments NI PXIe-5646R-G Getting started guide

LeadSolar
LeadSolar Energy Microinverter LS600 Installation & operation guide

Hitachi
Hitachi SJ700B SERIES Quick reference guide

SMA
SMA Sunny Boy SB 6000US installation guide

PAW
PAW SolarBloC midi 2D Installation and commissioning instructions

Hoymiles
Hoymiles MI-1000NT Quick installation guide

Cotek
Cotek SR-1600 Plus-124 user manual

Mitsubishi
Mitsubishi FREQROL-Z200-UL instruction manual

CPS
CPS SCA Series Installation and operation manual