Product Code: SSS
Instructions
Specifications:
Voltage: 220-240V/AC Power Frequency: 50/60Hz
Rated Current: 16A Ambient Light: <3-500LUX (adjustable)
Working Temperature: -20~+40℃Working Humidity: <93%RH
Built-in Timer: 1, 2, 3, 4, 5, 6, 7, 8 & 9 Hours IP Rating/Class: IP66
Function:
➢LUX setting: turn LUX knob anti-clockwise to “3”position, the photocell will only work in the
dark (less than 3 LUX). If you turn clockwise to “500” position, it will work when the ambient
light is less than 500LUX.
➢TIME setting: set the regular working hours of the photocell as needed
Installation:
➢Disconnect the power.
➢Loosen the four screws on the cover and remove the front cover (figure1).
➢Remove the end cap on the side and connect the wire as per wiring diagram (figure2).
➢Use the attached accessories to seal with conduit glue (refer to figure 3 & 4)
➢Install the 5 end caps included in the product as per (refer to figure 5).
➢Tighten the base of the product with the enclosed screws and insert the screw caps (refer to
figure6). Make sure the screws are tight and not loose (onto the base)
➢Mount the back the cover with enclosed screws and insert the screw caps (refer to figure7).
➢Switch on the power, and then test.
FIGURE 1 (INCORRECT) CORRECT
FIGURE 2 FIGURE 3 FIGURE 4
FIGURE 5 FIGURE 6 FIGURE 7
Connection wiring diagram
Time setting:
The LED indicator inside the sensor will flash to display the preset times as following:
1) 1 hour: flash one time 6) 6 hours: flash six times
2) 2 hours: flash two times 7) 7 hours: flash seven times
3) 3 hours: flash three times 8) 8 hours: flash eight times
4) 4 hours: flash four times 9) 9 hours: flash nine times
5) 5 hours: flash five times 10) dusk to dawn: rapidly flash ten times
Test after installation:
➢Set the LUX knob to “3”position and set the time knob to “1h”position. When the ambient
light is less than 3 LUX, the red indicator light will turn on, after 1 minute, the lamp will turn on.
1) In 1 hour, Ambient light < 3 LUX:
The lamp will hold on lighting for 1 hour. After 1 hour, it will turn off. The red indicator light will turn
off when the ambient light is more than 10 LUX.
2) In 1 hour, Ambient light > 10 LUX
The red indicator light will turn off, after 1 minute, the lamp will turn off.
When set the Time knob to 2-9h, please can refer to above description to test.
➢Set the LUX knob to “3”position and set the time knob to “DUSK TO DAWN”position, if the
ambient light is less than 3 LUX, the red indicator light will turn on, after 1 minute, the lamp will
turn on and hold on lighting. Only when the ambient light is more than 10 LUX, the red
indicator light will turn off, after 1 minute, the lamp will turn off.
For the product to function properly:
➢In front of the photocell: there should be no objects blocking the PE Cell from getting natural
light (including installing the product underneath the light)
➢When the lamp is on & if another light source (e.g sunlight) is illuminated to the photocell,
and this light source lasts for more than one minute, the lamp will turn off and the electronic
TIMER will stop counting.
➢The TIMER will recount from the beginning when the light (connected to the PE Cell)
turns on again.
➢The electronic TIMER will reset when the power is off over 2~5 seconds.

Popular Switch manuals by other brands

HP 5500-24G-PoE+-4SFP Product End-of-Life Disassembly Instructions

HP

HP 5500-24G-PoE+-4SFP Product End-of-Life Disassembly Instructions

Venus KVM 8 user manual

Venus

Venus KVM 8 user manual

Mitel StreamLine Hardware installation guide

Mitel

Mitel StreamLine Hardware installation guide

Linksys SE4008 user guide

Linksys

Linksys SE4008 user guide

LevelOne FSW-1640TX user guide

LevelOne

LevelOne FSW-1640TX user guide

ZILR LUMIN user manual

ZILR

ZILR LUMIN user manual

Kramer VP-438 user manual

Kramer

Kramer VP-438 user manual

SICK T4000 Direct Unicode operating instructions

SICK

SICK T4000 Direct Unicode operating instructions

Wöhner CAPUS Panel manual

Wöhner

Wöhner CAPUS Panel manual

Sun Microsystems IB Switch 9P Administration guide

Sun Microsystems

Sun Microsystems IB Switch 9P Administration guide

Wisi DY 94....98 operating instructions

Wisi

Wisi DY 94....98 operating instructions

Supermicro Intelligent Switch user guide

Supermicro

Supermicro Intelligent Switch user guide

Delta Electronics SK1027 Specifications

Delta Electronics

Delta Electronics SK1027 Specifications

ABB NE810 user manual

ABB

ABB NE810 user manual

SMC Networks 8612T - annexe 1 installation guide

SMC Networks

SMC Networks 8612T - annexe 1 installation guide

ORiNG TGPS-9168GT-M12 Quick installation guide

ORiNG

ORiNG TGPS-9168GT-M12 Quick installation guide

Jasco Enbrighten Zigbee Product specifications

Jasco

Jasco Enbrighten Zigbee Product specifications

Grundfos IO 50 SQFlex Installation and operating instructions

Grundfos

Grundfos IO 50 SQFlex Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.