manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SPARKELEC
  6. •
  7. Switch
  8. •
  9. SPARKELEC SSS User manual

SPARKELEC SSS User manual

Product Code: SSS
Instructions
Specifications:
Voltage: 220-240V/AC Power Frequency: 50/60Hz
Rated Current: 16A Ambient Light: <3-500LUX (adjustable)
Working Temperature: -20~+40℃Working Humidity: <93%RH
Built-in Timer: 1, 2, 3, 4, 5, 6, 7, 8 & 9 Hours IP Rating/Class: IP66
Function:
➢LUX setting: turn LUX knob anti-clockwise to “3”position, the photocell will only work in the
dark (less than 3 LUX). If you turn clockwise to “500” position, it will work when the ambient
light is less than 500LUX.
➢TIME setting: set the regular working hours of the photocell as needed
Installation:
➢Disconnect the power.
➢Loosen the four screws on the cover and remove the front cover (figure1).
➢Remove the end cap on the side and connect the wire as per wiring diagram (figure2).
➢Use the attached accessories to seal with conduit glue (refer to figure 3 & 4)
➢Install the 5 end caps included in the product as per (refer to figure 5).
➢Tighten the base of the product with the enclosed screws and insert the screw caps (refer to
figure6). Make sure the screws are tight and not loose (onto the base)
➢Mount the back the cover with enclosed screws and insert the screw caps (refer to figure7).
➢Switch on the power, and then test.
FIGURE 1 (INCORRECT) CORRECT
FIGURE 2 FIGURE 3 FIGURE 4
FIGURE 5 FIGURE 6 FIGURE 7
Connection wiring diagram
Time setting:
The LED indicator inside the sensor will flash to display the preset times as following:
1) 1 hour: flash one time 6) 6 hours: flash six times
2) 2 hours: flash two times 7) 7 hours: flash seven times
3) 3 hours: flash three times 8) 8 hours: flash eight times
4) 4 hours: flash four times 9) 9 hours: flash nine times
5) 5 hours: flash five times 10) dusk to dawn: rapidly flash ten times
Test after installation:
➢Set the LUX knob to “3”position and set the time knob to “1h”position. When the ambient
light is less than 3 LUX, the red indicator light will turn on, after 1 minute, the lamp will turn on.
1) In 1 hour, Ambient light < 3 LUX:
The lamp will hold on lighting for 1 hour. After 1 hour, it will turn off. The red indicator light will turn
off when the ambient light is more than 10 LUX.
2) In 1 hour, Ambient light > 10 LUX
The red indicator light will turn off, after 1 minute, the lamp will turn off.
When set the Time knob to 2-9h, please can refer to above description to test.
➢Set the LUX knob to “3”position and set the time knob to “DUSK TO DAWN”position, if the
ambient light is less than 3 LUX, the red indicator light will turn on, after 1 minute, the lamp will
turn on and hold on lighting. Only when the ambient light is more than 10 LUX, the red
indicator light will turn off, after 1 minute, the lamp will turn off.
For the product to function properly:
➢In front of the photocell: there should be no objects blocking the PE Cell from getting natural
light (including installing the product underneath the light)
➢When the lamp is on & if another light source (e.g sunlight) is illuminated to the photocell,
and this light source lasts for more than one minute, the lamp will turn off and the electronic
TIMER will stop counting.
➢The TIMER will recount from the beginning when the light (connected to the PE Cell)
turns on again.
➢The electronic TIMER will reset when the power is off over 2~5 seconds.

Popular Switch manuals by other brands

ANTAIRA LNX-800AG Hardware manual

ANTAIRA

ANTAIRA LNX-800AG Hardware manual

AbleNet SCATIR 51100 manual

AbleNet

AbleNet SCATIR 51100 manual

IOGear Wireless USB Hub and Adapter Kit GUWH204KIT installation guide

IOGear

IOGear Wireless USB Hub and Adapter Kit GUWH204KIT installation guide

Topaz Systems A-HUB1-1 Assembly guide

Topaz Systems

Topaz Systems A-HUB1-1 Assembly guide

Woodward DSS-2 installation guide

Woodward

Woodward DSS-2 installation guide

schmersal SHG Translation of the original operating instructions

schmersal

schmersal SHG Translation of the original operating instructions

ETI CRM-4 manual

ETI

ETI CRM-4 manual

geratech EGE-HD-541FS manual

geratech

geratech EGE-HD-541FS manual

Renkforce 2249725 operating instructions

Renkforce

Renkforce 2249725 operating instructions

sprecher + schuh L11-NU600-1753 installation instructions

sprecher + schuh

sprecher + schuh L11-NU600-1753 installation instructions

MHZ PowerView manual

MHZ

MHZ PowerView manual

PCB Piezotronics IMI SENSORS 691B43 Series Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 691B43 Series Installation and operating manual

Synergy Global Technology Combo DB-15 ip 2-console KVM user manual

Synergy Global Technology

Synergy Global Technology Combo DB-15 ip 2-console KVM user manual

Cambridge Research Systems BOLDscreen 32 AVI Getting started

Cambridge Research Systems

Cambridge Research Systems BOLDscreen 32 AVI Getting started

SY SY-MHDBT-44P installation guide

SY

SY SY-MHDBT-44P installation guide

Cisco Catalyst Blade Switch 3130 Installation

Cisco

Cisco Catalyst Blade Switch 3130 Installation

ESCAM PSE6004 Series user guide

ESCAM

ESCAM PSE6004 Series user guide

Emerson Avocent SV 220D Quick installation guide

Emerson

Emerson Avocent SV 220D Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.