Spectrum D101-(X)-P3807-PVE-BD Series User manual

SPECTRUM D101-(X)-P3807-BD Series
Explosion Proof Network Camera
Installation Manual
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
1

This pageintentionallyleft blank
2D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1

Information in this document is subject to change without notice. All terms
mentioned in this manual that are known to be trademarks have been
appropriately capitalized. Spectrum Camera Solutions LLC acknowledges
all trademark(s) and the rights of the trademark(s) owned by the company
referred to herein.
Release Date:02/05/2020
Document Name D101-A-P3807-PVE-BD
© Copyright 2019by Spectrum Camera Solutions LLC All rights
reserved
Revision Record
Rev. Description Date
0Initial Release
07/23/2020
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
3

Copyright Notice:
This document contains information proprietary to Spectrum Camera Solutions LLC
with all rights reserved worldwide.Any reproduction or disclosure of this publication,
or any part thereof, to persons other than Spectrum Camera Solutions, Inc.
personnel or customers is strictly prohibited, except by written permission of
Spectrum Camera Solutions, Inc.Unauthorized use, disclosure, reproduction, or
translation of this publication will result in Spectrum Camera Solutions, Inc.
exercising maximum possible legal action against all persons and /or organizations
involved.
Disclaimer:
Spectrum Camera Solutions LLC makes no representations or warranties with
respect to the contents hereof.Further, Spectrum Camera Solutions LLC reserves
the right to revise this publication and to make changes in the content hereof, without
obligation to notify any person or organization of such revision or changes.
Patent Notice:
Manufactured under United States US Patent 9917428 &US Patent D858611
Trademark Information:
Spectrum Camera Solutions LLC and its logo(s) are trademark(s) of Spectrum
Camera Solutions LLC.
4
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1

Table of Contents
Legal Notices and Revision History Inside front cover
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
5
Page
DESCRIPTION 6
MODEL MATRIX 7
LABELS 8
STANDARDS AND CERTIFICATIONS 9
DOCUMENT SYMBOLS 10
HOW TO USE THIS MANUAL 11
GENERAL SAFETY AND OPERATING INFORMATION 12
SPECIFICATIONS 15
UNBOXING 17
HARDWARE BOM 18
WIRING ENTRIES 19
INSTALLATION 20
DIMENTIONAL GENERAL ASSEMBLY 25
DISMANTLING & MAINTENANCE 26
MOUNTING OPTIONS 28

D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
6
The “D” Series includes a full range of Stainless Steel or Anodized Aluminum camera stations
specifically designed for Hazardous Area Applications.
Spectrum’s D Series is the first Class I II III Division 1 rated dome style explosion proof
housings and utilizes the most robust and advanced camera technologies available. The D
Series was designed with the integrator in mind and offers features not available in competing
EX camera systems available in the market. The solution is Patented with features including a
uniform constructed enclosure consisting of an integrated junction box milled directly to the
camera housing. This eliminates the need for extra equipment, reduces installation time,
reduces labor expenses, and increases safety by lessening the potential for mismatched
hazardous rated components. Additionally, the D Series are constructed with a proprietary
explosion resistant polymer blend offering maximum clarity and enhance optical performance.
To enhance optical performance, the explosion proof lens is equipped with our Virtual Wiper
Nano Technology. The series are available in anodized aluminum or 316L Stainless steel
ensuring protection against rain, dust and corrosion within a wide temperature range between -
20°C to 55°C. This feature ensures operation under extreme weather conditions and hazardous
environments. It is suitable for monitoring wide open indoor/outdoor spaces such as refineries,
wellheads, pipelines, offshore installations, remote and harsh locations where high-level
reliability and precision are always required.
DESCRIPTION

Option A-Model Matrix-D100-D500*
D(N)(XX)-(1)-(CCCCCC)-BD
N=(1) HOUSING LENGTH=3.32 in
N=(2) HOUSING LENGTH=7.75 in
N=(3) HOUSING LENGTH=4.5 in
N=(4) HOUSING LENGTH=5 in
N=(5) HOUSING LENGTH= 5.5 in
XX= Internal Equipment Manufacturer Code**
1= (A) Aluminum Housing with SS 316L Dome Ring
1= (S) Stainless Steel 316L Housing
C= Internal Equipment Part Number from Manufacturer***
BD= Optional Breather drain model****
*Internal components and D Series must be approved by Spectrum
**Internal Equipment Manufacturer Code below
***Must be approved and verified by Spectrum
****Models supplied with Breather Drains will have IP66 ingress protection level
CODE “XX”
Manufacture
01
AXIS COMMUNICATIONS
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
7

STANDARDS & CERTIFICATIONS
9D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
STANDARDS-
The equipment is manufactured in accordance with the IECEX scheme, the ATEX Directive 94/9CE and with the
following standards :
IEC 60079-0:2011
IEC 60079-1:2014
IEC 60079-31:2013
IEC 60529:2013
EN 60079-0:2012 + A11:2013
EN 60079-1:2014
EN 60079-31:2014
EN 60529:1991 + A1:2000 + A2:2013
ANSI/ISA 60079-0:2013
ANSI/UL 60079-1:2015
ANSI/ISA 60079-31:2015
ANSI/IEC 60529:2004
CAN/CSA-C22.2 No. 60079-0:2015
CAN/CSA-C22.2 No. 60079-1:2016
CAN/CSA-C22.2 No. 60079-31:2015
CAN/CSA-C22.2 No. 60529:2016
Specific Conditions of Use:
-The flameproof joints of the equipment are not intended to be repaired. Consult the manufacturer if dimensional
information on the flameproof joints is necessary.
-Follow the manufacturer’s instructions to reduce the potential of an electrostatic charging hazard on the surface
of the equipment in Group II and III environments.
-The equipment meets the requirements according to the low-level risk of mechanical danger. Therefore, the
equipment shall be located and installed such that the risk of impact or other mechanical damage is reduced or
avoided.
CERTIFICATIONS-
CERT NO. FM17US0156X & FM18CA0103X
Class I Division 1 Groups B,C,D T6, Ta = -20°C to +55°CType 4X, IP66
Class II/III, Division 1, Groups E,F,G T6 Type 4X, IP66 Ta = -20°C to +55°C
Class I, Zone 1, AEx/Ex db IIB+H2 T6 Gb Ta = -20°C to +55°C, Type 4X, IP66
Zone 21, AEx/Ex tb IIIC T85°C Db Ta = -20°C to +55°C, Type 4X, IP66
CERT NO. FM18ATEX0057X & IECEx FMG 18.0020X
II 2 G Ex db IIB+H2 T6 Gb Ta = -20°C to +55°C, IP66
II 2 D Ex tb IIIC T85°C Db Ta = -20°C to +55°C, IP66

The following symbols are used throughout this manual to alert users to potential
hazards or important information.Failure to heed the warnings and cautions listed
herein can lead to injury and equipment damage.
Symbol Label Description
WARNING: Consists of conditions, practices, or procedures that
must be observed to prevent personal injury and/or
equipment damage.
CAUTION: Risk of electric shock or high temperature parts may
result in injury if proper precautions are not taken.
NOTE: Emphasizes important or essential information.
Locating Information:
NOTE: In the interest of completeness, manuals and drawings included with the
system may provide information pertaining to options not included with your
equipment. Information in application notes supersedes general information in
these documents. Information can be in this manual using any of the following aids.
10D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
DOCUMENT SYMBOLS

How to use this Manual
Safety Considerations:
This information that must be read and understood by all persons installing,
using, or maintaining this equipment. This manual is designed to aid
personnel in the correct and safe installation, operation, and maintenance of
the systems described. Personnel must consider all actions and procedures
for potential hazards or conditions that may not have been anticipated in the
written procedures. If a procedure cannot be performed safely, it must not be
performed until appropriate actions can be taken to ensure the safety of
equipment and personnel. The procedures in this manual are not designed to
replace or supersede required or common-sense safety practices. All safety
warnings listed in any documents applicable to equipment and parts used in
or with the system described in this manual must be read and heeded before
commencing work on any part of the system.
NOTE: Refer to all ATEX, CSA, IECEx, NEC, NFPA and FM certificates
for any Special Conditions of Use. If the sign “X” is placed after the
certificate number, it indicates that the equipment or protective
system is subject to special conditions for safe use specified in the
schedule of the certificate.
NOTE: Review all material and safety information in this manual and
install in accordance with this document and all other applicable
ATEX, CSA, IECEx, NEC, NFPA70 Installation Methods and FM and
National standards.
Warning-Failure to follow appropriate safety procedures or
appropriate use of the equipment described in this manual can lead to
injury of personnel or equipment damage.
WARNING –EXPLOSION HAZARD –Do not open equipment
unless power has been removed or the area is known to be non-
hazardous.
General Manual:
This manual is intended to be used in conjunction with installed equipment
manual from internal equipment manufacturer.
Note: In the event of a conflict between the requirements of this general
installation manual and the internal equipment manual, the safety and
installation procedures described in this manual shall take precedence.
11D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1

General safety and operating information applicable to electrical equipment installed within
hazardous locations. This information must be understood by all persons installing, using, or
maintaining the electrical equipment. This information is designed to aid personnel in safe
installation, operation, and maintenance of the "D" Series equipment. It is not designed to replace or
limit appropriate safety measures applicable to work performed by personnel. Any additional safety
and operating measures that are required must be determined by and followed by personnel
performing work on the electrical equipment.
WARNING: Deviation from the specified instructions or procedure steps can result
in injury to personnel, equipment malfunction or equipment damage.
WARNING: Return unit to factory for any repairs or replacement of parts, customer
is not permitted to repair. This will void all warranties and hazardous area
certification(s) if non-authorized repair occurs.
General Precautions:
Slip resistant gloves and protective eyewear (glasses with side shields or goggles as appropriate)
should be worn when installing and servicing any part of electrical equipment. Hot components
should be allowed to cool before servicing if possible. Other appropriate equipment or clothing must
be used as required by the type of work performed. All applicable regulations and procedures must
be followed for the work performed. Before beginning any work on the equipment, carefully consider
all the potential hazards and ensure that appropriate measures are taken to prevent injury to
personnel or equipment damage.
CAUTION: Electrical equipment components may be hot even when power is
not applied. Take appropriate precautions to prevent injury from contact with hot
items.
12
WARNING:
NEVER open the main housing of the "D" Series unless
authorized and trained and certified to do so by the manufacturer
The main housing is manufactured in a controlled environment that eliminates
moister at the factory and is only to be opened by factory certified technicians at an
authorized repair facility. Opening of the main housing will void all warranties.
CAUTION: Failure to allow adequate cooling of electrical equipment components
with hot surfaces before opening the enclosure can lead to injury of personnel or
equipment damage.
General Safety and Operating Information:
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1

Electrical Power:
The "D" Series IP cameras operate from a variety of power options including IEEE compliant POE devices.
•The power supply used with this product shall fulfill the requirements for Safety Extra Low
Voltage (SELV) and Limited Power Source (LPS) according to IEC/EN/UL 62368-1 or
IEC/EN/UL 60950-1 or Listed Class II Power Source Equipment. The product shall be
grounded either through a shielded network cable (STP) or other appropriate method.
Camera Location:
The "D" Series IP camera must be installed in a suitable location away from impacts, heavy vibration and
extreme heat. The "D" Series camera must not be installed in an area classification for which it is not rated.
The "D" Series camera must be attached securely and appropriately to a wall or supporting structure.
CAUTION: The electrical cover should never be removed unless
power is removed (for at least 5 minutes) from the unit or the area is
known not to contain explosive materials.
13
WARNING
• The product shall be installed by a trained professional.
• The product shall be used in compliance with local laws and regulations.
• Store the product in a dry and ventilated environment.
• Avoid exposing the product to impacts, shocks or heavy pressure.
• Do not install the product on unstable brackets, surfaces or walls.
• Use only applicable tools when installing the product. Using excessive force with power tools
could cause damage to the product.
• Do not use chemicals, caustic agents, or aerosol cleaners.
• Use a clean cloth dampened with pure water for cleaning.
• Use only accessories that comply with the technical specification of the product. These can be
provided by Spectrum or a third party.
NOTE:
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
General Safety and Operating Information:

Installation:
The installation must be realized in accordance with IEC/EN 60079-14 and/or in accordance
with the national requirements. This equipment must be installed and used only by qualified
personnel, having knowledge concerning electrical equipment for use in potentially
explosive areas containing gas and/or dust. Qualified personnel must have knowledge
regarding the types of explosion protection. This equipment is intended to be used in zone 1,
2, 21 and 22 for groups IIB+H2 and IIIC with temperature class T6 or T85°C, it is necessary to
verify if this equipment is in accordance with the atmosphere where it is installed.
Connections:
Electric parameters power control unit Maximum supply voltage: POE+ IEEE 802.3at/af/bt
The terminals are suitable for solid and stranded wires.-*See wiring Diagram Page
Cable Glands:
The cable entry must be made and installed properly in order not to alter the specific
properties of terminal housing compartment. The connection to the external circuits must be
realized by cable glands or pipe fittings covered by a separate certificate(s). If a cable gland
is not used or an entry is open, the entry must be closed by a stopping plug covered by a
separate certificate. The diameter of the cable gland is cylindrical ISO M20 x 1.5.
This equipment can be used with different voltage and power, the nominal parameters are
specified in the manual.
Cable: cable must be tested and certified for temperatures of 70°C or higher.
Fiber Cable: Use a suitably certified optical fiber cable and internal connections shall comply
with requirements of IEC/EN 60079-15
Equipment Modifications:
This equipment must be installed and used in strict accordance with the instructions given in the
user documentation. This equipment contains no user-serviceable components. Unauthorized
equipment changes or modifications will invalidate all applicable regulatory certifications and
approvals.
14D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
General Safety and Operating Information:

SPECIFICATIONS
Environmental Conditions-D101-A-P3807-PVE-BD
(Equipment must be powered)
OPERATIONONAL CONDITIONS
USE
For
indoor and outdoor use
15
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
CERTIFICATIONS of Model-D101-A-P3807-PVE-BD
CERT NO. FM17US0156 & FM18CA0103X
Class I Division 1 Groups B,C,D T6, Ta = -20°C to +55°C Type 4X, IP66
Class II/III, Division 1, Groups E,F,G T6 Type 4X, IP66 Ta = -20°C to +55°C
Class I, Zone 1, AEx/Ex db IIB+H2 T6 Gb Ta = -20°C to +55°C, Type 4X, IP66
Zone 21, AEx/Ex tb IIIC T85°C Db Ta = -20°C to +55°C, Type 4X, IP66
CERT NO. FM18ATEX0057X & IECEx FMG 18.0020X
II 2 G Ex db IIB+H2 T6 Gb Ta = -20°C to +55°C, IP66
II 2 D Ex tb IIIC T85°C Db Ta = -20°C to +55°C, IP66
Electrical Requirements-D101-A-P3807-PVE-BD
POWER
INPUT/CONSUMPTION
Power over Ethernet (PoE) IEEE 802.3af/802.3at Type 1
Class 3
Typical 6.1 W, max 11.4 W
VOLTAGE 44-57 Vdc 12.9W

NOTE:Spectrum Camera Solutions, LLC is NOT responsible for any misuse
or improper installation of product, assumes no liability for special or
consequential damages caused by use or misuse or improper installation of
its products sold and assumes no liability for injury from use or misuse or
improper installation of its products or attached products.
16D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
SPECIFICATIONS
D101-(X)-P3807-PVE-BD Series Casing Material Specifications
-S-316L STAINLESS STEEL 47lbs
-A- ANODIZED ALUMINUM 19lbs
D101-(X)-P3807-PVE-BD Explosion Proof
Camera Hazardous Area
Voltage Material Model Number
IEEE 802.3af/at Type 2 Class 4
PoE Midspans/PoE Injectors
316L STAINLESS STEEL or
ANODIZED ALUMINUM
D101-X-P3807-PVE-BD
Power Source Specification For D101-(X)-P3807-PVE-
BD
Reference Axis Manual

D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
17
UNBOXING
12345
67
1. Place camera on tabletop with dome facing down
2. Remove rear (Terminal Housing) foam packaging to reveal hardware
3. Remove hardware
4. Install ring Gasket on terminal Housing *Optional SD-GK Aluminum version only
5. Install wall mount with hardware removed from step 3 (Note: Apply Anti-seize to
bolts.)
6. Install wall mount gasket and hardware to secure mount to wall.*SD-GK
7. Remove foam and protective blue film
(Note: Apply Anti-seize to bolts.)
Optional SD-GK Anti-Galvanic
corrosion isolation gasket kit for
offshore use of Aluminum version

19D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
WIRING ENTRIES
Conduit Entries are M20 x 1.5 Use appropriate adapter
with nylon Washer or O-ring to keep ingress protection
level.
CAUTION: Ensure the Ethernet cable is disconnected from power source prior to wiring to
the terminal block

CAUTION: Ensure the Ethernet cable is disconnected from power
source prior to wiring to the terminal block
20
Ensure that power is off before attempting to connect and wire the camera
1. Use supplied M6 Hex tool to unscrew bolts and lock washers supplied on camera
2. Make sure threads on camera and M10x 1.5 are free of dirt and debris. Place mount on camera
and align holes and tighten bolts *add anti-seize for offshore installation
3. Attach the camera with wall mount to mounting surface. Use only installation methods and
materials capable of supporting four times the maximum specified load of the system
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
Figure 1. wall bracket installation
INSTALLATION