STANDARDS & CERTIFICATIONS
9D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
STANDARDS-
The equipment is manufactured in accordance with the IECEX scheme, the ATEX Directive 94/9CE and with the
following standards :
IEC 60079-0:2011
IEC 60079-1:2014
IEC 60079-31:2013
IEC 60529:2013
EN 60079-0:2012 + A11:2013
EN 60079-1:2014
EN 60079-31:2014
EN 60529:1991 + A1:2000 + A2:2013
ANSI/ISA 60079-0:2013
ANSI/UL 60079-1:2015
ANSI/ISA 60079-31:2015
ANSI/IEC 60529:2004
CAN/CSA-C22.2 No. 60079-0:2015
CAN/CSA-C22.2 No. 60079-1:2016
CAN/CSA-C22.2 No. 60079-31:2015
CAN/CSA-C22.2 No. 60529:2016
Specific Conditions of Use:
-The flameproof joints of the equipment are not intended to be repaired. Consult the manufacturer if dimensional
information on the flameproof joints is necessary.
-Follow the manufacturer’s instructions to reduce the potential of an electrostatic charging hazard on the surface
of the equipment in Group II and III environments.
-The equipment meets the requirements according to the low-level risk of mechanical danger. Therefore, the
equipment shall be located and installed such that the risk of impact or other mechanical damage is reduced or
avoided.
CERTIFICATIONS-
CERT NO. FM17US0156X & FM18CA0103X
Class I Division 1 Groups B,C,D T6, Ta = -20°C to +55°CType 4X, IP66
Class II/III, Division 1, Groups E,F,G T6 Type 4X, IP66 Ta = -20°C to +55°C
Class I, Zone 1, AEx/Ex db IIB+H2 T6 Gb Ta = -20°C to +55°C, Type 4X, IP66
Zone 21, AEx/Ex tb IIIC T85°C Db Ta = -20°C to +55°C, Type 4X, IP66
CERT NO. FM18ATEX0057X & IECEx FMG 18.0020X
II 2 G Ex db IIB+H2 T6 Gb Ta = -20°C to +55°C, IP66
II 2 D Ex tb IIIC T85°C Db Ta = -20°C to +55°C, IP66