MICRO DISPLAY SINGLE LOAD DRYER SPECIFICATIONS
* Electric dryers come equipped for 120/240/60/1 operation. They can be field converted to operate on 120/208/60/1 with optional 61928 conversion kit.
** Gas dryers can be field converted for operation on LP gas with optional 458P3 conversion kit.
21.56 in (54.8 cm) Coin Slide
22.06 in (56 cm) Electronic Ctrl
23.5 in
(59.7 cm) 28 in
(71.1 cm)
8.0 in
(20.3 cm)
0.4 in
(1.02 cm)
26.9 in
(68.3 cm)
*4.5 in (11.4 cm)
*36 in (91.4 cm)
2.8 in
(7 cm)
+15.4 in
(39.1 cm)
*40.19 in (102 cm) Coin Slide
*38.19 in (97 cm) Electronic Ctrl
*15.44 in
(39.2 cm)
*43 in (102.2 cm)
Standard Capacity Meter Case
*43.875 in (111.44 cm)
High Capacity Meter Case
*with leveling legs turned into base
2.3 in
(6 cm)
0.4 in
(1.02 cm)
3/8 in N.P.T. Gas Connection
Only on Gas Models
For the most accurate information, the installation guide should be used for all design and construction purposes.Due to continuous product improvements, design and
specifications subject to change without notice.The quality management system of Alliance Laundry Systems’ Ripon facility has been registered to ISO9001:2008.
© 2013 Alliance Laundry Systems LLC AM11-0327R1
Speed Queen | 800-345-5649 | www.speedqueen.com/route
Elec (“E” - 208V)
Elec (“E” - 240V)
Gas (“G”)
SDEY07WF1500
SDEY07WF
SDGY09WF
SDEBXRGS171TW02
SDGBXRGS111TW02
SDEX07WF1500
SDEX07WF
SDGX09WF
SDEBCRGS171TW02
SDGBCRGS111TW02
SDET07WF1500
SDET07WF
SDGT09WF
Activation Prep Card “Y” Prep Coin “X” Prep Coin “X” Coin “C” Coin Drop Installed“T”
Appearance
Color White White White White White
Control Panel Selection Rear Rear Rear Rear Rear
Meter Case
Standard or High Capacity Standard High Capacity Standard High Capacity Standard
Technical Info
Galvanized Cylinder Volume cu.ft.(liters) - 7.0 (198)
Cycle Temperature - High, Medium, Low, Delicate
Motor (Capacitor Start and Thermal Protected) - 1/3 HP
Weight - lb (kg) Elec 135 (61) 135 (61) 135 (61) 135 (61) 135 (61)
Gas 140 (64) 140 (64) 140 (64) 140 (64) 140 (64)
Shipping Weight
lb (kg)
Elec 145 (66) 145 (66) 145 (66) 145 (66) 145 (66)
Gas 150 (68) 150 (68) 150 (68) 150 (68) 150 (68)
Electrical
Requirements
Elec 208V
Elec 240V
Gas
120/208/60/1 30 amp
120/240/60/1 30 amp*
120/60/1 15 amp
120/240/60/1 30 amp*
120/60/1 15 amp
120/240/60/1 30 amp*
120/60/1 15 amp
120/208/60/1 30 amp
120/240/60/1 30 amp*
120/60/1 15 amp
120/240/60/1 30 amp*
120/60/1 15 amp
Overall Dimensions - WxDxH in (mm): 26 7/8” (683) x 28” (711) x 43” (1092)
Type Of Gas (Gas Models Only) Factory-Equipped Natural/Mixed Gas**
Air Outlet Diameter - in (mm):4” (102)
Exhaust Airflow - cfm (liters/sec): 220 (105)
Heating Element
Elec 208V
Elec 240V
Gas
4750W, 208V
5350W, 240V
25,000 Btu
5350W, 240V
25,000 Btu
5350W, 240V
25,000 Btu
4750W, 208V
5350W, 240V
25,000 Btu
5350W, 240V
25,000 Btu
Performance/Features
Cycle Status Indicators
Touch Pad Control with Sound Annunciator
Agency Approval Elec cULus cULus cULus cULus cULus
Gas cCSAus cCSAus cCSAus cCSAus cCSAus