Spirit TLS1850 Use and care manual

Pond & Waterfall Pumps
Instructions for Operation • Safety • Warranty
Designed for minimal solids applications
TLS1850 • TLS2750 • TLS4250
Thank you for purchasing the Spirit Pond & Stream pump from EasyPro. These pumps are designed for
continuous duty use in small ponds, statuary, Just-A-Falls, etc. A great choice for ponds with light debris
laden water.
Specications
• Canberuninverticalorhorizontalpositionsforcompactapplications
• Oil-lessdesign,shandplantsafe
• Impellerdesignedforpassingdebrisupto1/4" diameter
• 11/4" female threaded outlet with a 11/4" x 11/2" elbow included
• Triplesealed115vmotorswith18monthwarranty
• Automaticoverloadandthermalprotectionwithselfreset
Run in vertical or horizontal position
Safety & Electrical Connections
1. Always disconnect the electricity supply before handling, maintaining,
repairing or installing any pond equipment.
2. Alwaysmakesureyouknowthecorrectampsandvoltagerequiredbeforeinstalling.
3. Usededicatedpoweroutletonly.Sharingtheoutletwithotherequipmentmaycauseoverheatingandre.
4. EasyProTLSpumpscomein115voltonly.
5. AlwaysconnecttoaGroundFaultCircuit(GFCI)topreventelectricalshock.Neversubmergeconnectingpowercablepluginwater.
6. Neverletthepumprunwithoutwaterasthiswilldamagetheimpeller,overheatandpossiblyburnoutthepump.Thispumpmust
staysubmergedentirelywhenopeating.Ifusedinaskimmer,thedebrisnetmustbekeptcleantoensureadequatewaterowto
pump.Runningpumplowonwaterwillcauseoverheating,prematurefailureandwillvoidwarranty.
7. Do not use this product in bathrooms or swimming pools. For use with fresh water only.
8. Donotletthewaterlevelinyourwaterfeaturefallbelowthetopofthepumpbody.
9. Allelectricalworkmustbeperformedbyaqualiedtechnician.AlwaysfollowtheNationalElectricalCode(NEC)ortheCanadianElectrical
Codeaswellasalllocal,stateandprovincialcodes.Codequestionsshouldbedirectedtoyourlocalelectricalinspector.Failureto
followelectricalcodesandOSHAsafetystandardsmayresultinpersonalinjuryorequipmentdamage.Failuretofollowmanufacturer’s
installationinstructionsmayresultinelectricalshock,rehazard,personalinjuryordeath,damagedequipment,provideunsatisfactory
performanceandmayvoidmanufacturer’swarranty.
10.Donotattempttodisassemblepumpduringthewarrantyperiod.IfthereareanyquestionspleasecontactyourlocalEasyProdealer.
11. Neveruseanextensioncordortamperwithpowercord.Powercordcannotbecomebent,twisted,abradedorcut.Adamgedcablemay
causeelectricleakage,shockorre.
12. Themotorhasabuilt-inprotectionsystemwhichstopsthepumpwhenoverheatingoccursduetoexcessiveloadorlowwater,thiscanbe
causedbycloggingatinlet/outletorwhenucuationsoccurinpowersupply.Thecoolingtimeisroughly15to20minutes,thenthepump
willautomaticallycomebackon.Iftheoverloadistripped,itisessentialtoidentifyandremedythecauseoftheoverheating.
Installation
• Donotpaintcasing,overheatingmayoccur
• Liftonlybyhandle,notbypowercableoroatswitch
• Donothangpumpinwater,installonsolidatbaseinuprightorhorizontalposition
• Installproperoutletadapterforpipeorhose
• Makesurethatpowercableplugandpoweroutletareawayfromwaterandwaterdischargepipe/hose.

Operation
1. Do not start operation with people standing
near intake or outlet.
2. Do not operate out of water.
3. Pump must remain fully submersed.
4. Onlyusepumpforcirculation,transferorremovalofwaterwithlimitedsolids1/4" or smaller.
5. Donotpumpoil,saltwater,sewage,foodorchemicalliquids.
6. Do not allow dry operation
7. Donotallowforeignobjectstoclogorenterintake
8. Incaseofpoweroutage,turnopowerswitchtoavoiddamagewhenpowerisrestarted.
9. Ifexcessivevibrationoccursturnopowerimmediately.
Service & Maintenance
1. Disconnectallpowersuppliesbeforeinspectionorservicetoavoid
possible electrical shock.
2. Thepumpshouldberemovedfromthepondonaregularbasis,cleanedandcheckedoverfordamagetoprolongthelifeofthepump.
3. Cleantheimpellerandintakescreenwhentheowisvisiblyreduced.
4. Cleanthepumpandimpellerwithcleanfreshwater.
5. Checkinsidetheimpellerhousingforlargedebrisoralgae,whichcouldreducetheow.
6. Checkandtightennutsandboltsifrequired,refertodealerforadviceonotherrepairs.
7. Winterization/Storage:Whenthepumpisoutofuseforextendedtime-washanddryitthenstoreindoorsinanon-freezinglocation.Itis
besttostoreinabucketwithaboutan8"waterdepth.Itisessentialtopreventanyriskofthepumpfreezing.
8. Ifthepumpisleftinwaterbutnotoperatingregularly,testrunitatleastonceaweek.
Trouble Shooting
Beforetakinganytroubleshootingaction,disconnectpumpfromthepowersupply.Ifthereisanydamagetothepowercordorpump,repairs
orreplacementsmustbehandledbyEasyProoraqualiedparty.
Doesnotstart • Makesurepowercordispluggedin
• Float(notincluded)maynotbemovingfreely,increasedepth
Doesnotshut-o • Pumpisnotdisabledbyoat(notincluded),makesureoatcanmovefreely
Humming • Linecircuitbreakeriso,fuseisburnedorloose
• Pumpcordisnotmakingcontactinreceptacle
Running,nowater• Suctiongridorpipingareclogged
• Impelleriswornorstuck
• Requiredheadistoohighforthepumpspecications
• Waterlevelistoolow
Running,very • Pumpisair-locked,startandstopseveraltimesbypluggingandunpluggingcord,checkforcloggedventhole
littlewater • Verticalpumpingdistanceistoohighorthepipesizeistoosmall
• Inletorimpellerclogged
• Lowwaterconditionswithpumpsuckingair
GFCIbreaker • Mechanicalsealsmayneedtobereplaced
tripping • Powercordmaybedamagedandgettingwet
• Nuisancetripduetoimpropergrounding
• Overloadedcircuit
Motorbriey • Lowwaterconditions,pumpoverheating
startsandstops • Inletorimpellerclogged
• Improperpowersupply
Pumpsstops • Makesurewaterbeingpumpedisnottoodense,causingthepumptooverheat.
• Clearobstructionsonimpeller
• Checkpowersupplytocomplywithnameplatedata
• Waitforpumptocool,correctreasonforoverheating,plugbackinandresumeoperation

30
25
20
15
10
5
0
0 10 20 30 40 50 60 70
Head (ft)
Capacity (GPM)
TLS1850 TLS2750 TLS4250
EasyPro TLS Pump Performance
35
Discharge 11/4"fpt•Elbow11/2" fpt
Voltage115v,60hz•PowerCord16'
Maximum Maximum
Part # Gph Hp Watts Head
TLS1850 1850 1/4 260 21'
TLS2750 2750 1/3 370 29'
TLS4250 4250 1/2 820 33'
Specications
800-448-3873•Grant,Michigan
www.easypro.com
9972WEB•10/19
EasyPro Pond Products Limited Warranty
EasyProPondProducts(“EasyPro”)warrantstothepurchaserthatthisproduct("Product")willbefreefromanymechanicalormaterialdefectsfora
period of 18 monthsfromthedateofpurchase.Thiswarrantydoesnotcoveraccidentaldamagetotheproductduetoabuseornegligencebythe
consumer.ThiswarrantyonlycoversproperlyinstalledandmaintainedProductssoldbyauthorizedEasyProSellerswhoaresubjecttoandfollow
EasyPro’squalitycontrolstandards.PleasenotethatbecauseEasyProisunabletocontrolthequalityofProductssoldbyunauthorizedsellers,
unlessotherwiseprohibitedbylaw,thiswarrantydoesnotcoverProductspurchasedfromunauthorizedsellers.
Thiswarrantydoesnotcovernormalwearandtear,noranydeteriorationsueredthroughoverloading,improperuse,negligence,improper
installation,actsofGodoraccident.Similarly,anymodicationmadebythepurchasertotheProductwillcausethewarrantytobenullandvoid.
ThiswarrantydoesnotcoveranycostassociatedwiththeinstallationorremovaloftheProductsubjecttoawarrantyclaim.
Allreturneditemswillbeinspectedtodeterminecauseoffailurebeforeawarrantyclaimisapproved.Theexclusiveremediesprovidedhereunder
shall,uponEasyPro’sinspectionandoption,beeitherrepairorreplacementoftheProductorpartscoveredunderthiswarranty.
Making a Claim: AReturnAuthorization(“RA”)numbermustrstbeobtainedbycallingEasyProat800-448-3873orviaemailatwarranty@easypro.com.Itis
thepurchaser’sresponsibilitytopaythereturnshippingcharges.BesuretoincludetheRAnumber,originalreceipt(intheformofaninvoiceorsalesreceipt),
yourname,yourreturnaddressandyourphonenumberinsideofthepackage.Nowarrantyclaimswillbehonoredwithouttheoriginalreceiptthatshowsthat
yourpurchasewasmadefromanAuthorizedEasyProSeller.Ensuretheproductisproperlypackagedandinsuredforthereplacementvalue.Damagedueto
improper packaging is the responsibility of the sender.
ALLOTHEREXPRESSORIMPLIEDWARRANTIESINCLUDINGMERCHANTABILITYOFFITNESSFORAPARTICULARPURPOSEAREHEAREBYLIMITED
INDURATIONTOTHEDURATIONOFTHEWARRANTYASDESCRIBEDABOVE.SomeStatesdonotallowlimitationsonhowlonganimpliedwarrantylasts,
sotheabovelimitationsmaynotapplytoyou.
EasyProshallnotbeheldliableforanydamagescausedbydefectivecomponentsormaterialsofthisProduct;orforlossincurredbecauseoftheinterruption
ofservice;oranyconsequential/incidentaldamagesandexpensesarisingfromtheproduction,sale,useormisuseofthisProduct.SomeStatesdonotallow
theexclusionorlimitationofincidentalorconsequentialdamages,sotheabovelimitationorexclusionmaynotapplytoyou.
EasyProshallnotbeheldliableforanylossofsh,plantsoranyotherlivestockasaresultofanyfailureordefectofthisProduct.Thiswarrantygivesyou
speciclegalrights,andyoumayalsohaveotherrightsthatvaryfromStatetoState.
This manual suits for next models
2
Table of contents
Popular Water Pump manuals by other brands

Pearl
Pearl CEP-C2P Installation and operating instructions

Grundfos
Grundfos SE Installation and operating instructions

Craco
Craco Fire-Ball 425 Instructions-parts list

Oase
Oase WaterTank 50 operating instructions

Crane
Crane Barnes PGPT Series installation manual

proril
proril TANK Series instruction manual

KoolScapes
KoolScapes KSPK84 owner's manual

Agilent Technologies
Agilent Technologies 1260 Infinity II user manual

WITA
WITA go.future light 40 series TRANSLATION OF THE ORIGINAL INSTALLATION AND OPERATING INSTRUCTIONS

Tuthill
Tuthill 300V Series Owner's operation & safety manual

T.I.P.
T.I.P. I-COMPAC 7500 manual

Standart
Standart SDS-UL Instruction for operation and maintenance