Fig. 2wiringreference mapofCE-S#28-##4MD4
6 Installations
DIN35 rail-mountedorscrew-mountedinstallation,theinstallation
size isas showninfigure3(inmm).
Fig.3
7 Product sService
1Installation
1.1 DIN rail installationmethod:
①Thetransducerfixedon thesideofthecardslotand hook
on themountingrail;
②Pull thespringpindown;
③Clipthetransducermounton themountingrail;
④Release thespringpinandclipthetransmitteron the
mountingrail.
1.2 Screwmountingmethod:
①4mm diameterholeinthefixedplateaccordingtothe
positionofthescrewholeshowninFig.9;
②Use thescrew Φ3.5toinsert intoholeandsecureit.
2Productsfactoryhas beenaccuratelysetaccordingtothe
"productstandard".Applypowerafterdeterminethecorrect
wiring.
3Themaximumwirediameteroftheterminalblockis2mm
(16-26AWG).Removethe4mm~5mminsulationlayerfrom
theend ofthemountingwireand insert it intotheterminal
block, thentightenthescrew.
4Productsupplypowerrequires theisolationvoltage ≥2000VAC,
ACripple<10mV.Multipletransducerscanshareacommon
setofpowersupplies,butthepowercircuit cannolongerbe
usedtodriverelaysand othercanproduce spikes intheload,
inordertoavoidinterference signaltransmission tothe
transducer.
5 Thetransducersoutput0-20mA(or4-20mA),theRLstandardis
≤500Ω,and 0-5VvoltageoutputRLstandardis ≥2KΩ,can
guarantee theoutputaccuracyand linearityovertheentire
ratedinputrange.
8 Example ofproductaccuracy levelverification
1Accordingtothedefinitionofthetransducerterminalsto
connectthetestcircuit.
Figure4,testwiringdiagramofaccuracyoftwoinputstwo
outputsisolator
(Takethe CE-SU28-344MD4-0.2 as anexample)
2Thetestshall becarriedoutunderthefollowingenvironmental
conditions:
◆Powersupply:nominal 5%, ripple ≤10mV;
◆Ambienttemperature:25 °C 5°C;
◆Relativehumidity:RH (45 ~80)%;
◆Theaccuracyofthesignalsource and measurement
instrumentis0.05%above.
3Powerpreheat2mins;
4VoltageUandCurrentIinputand monitoringmethods:
Ahigh-precision high-currentmetercalibratorcandirectlyinput
ACcurrentIorvoltageVo,andrecordthedisplaydataofthe
metercalibration instrument.
5Assumingthatthefirstwayinputrangeofisolatoris0-5VDC,
output0-5VDC,thesecond wayinputrangeis0-10VDC,
outputis0-20mADC,giveinputvalueVi1and Vi2withinthe
rangeoftheisolator,theexpectedtheoreticaloutputVzandIz
oftheisolatoriscalculatedas follows:
Vz=Vi1 ÷5VDC ×5V
Iz=Vi2 ÷10VDC ×20 mA
6MeasurethefirstwayoutputvalueVoandthesecondway
outputvalueIowiththeoutputmonitoringtable:
|Vz-Vo|≤10mVisnormal, orexcessive(0-5VDC output,0.2);
|Iz-Io|≤40uAisnormal, orexcessive(0-20mADC output,0.2);
7RepeatNO.5andNO.6operations,theresultingphase errorin
eachpointarewithinthespecifiedaccuracy,thetransducer
accuracylevelisqualified.
Note: please consult withourcompanyfortheverification method