Stafer 595.K.F2.00 Operating instructions

www.stafer.com
USER AND MAINTENANCE MANUAL:
Sun/wind anemometer for 1 or 2 motors ENG
595.K.F2.00
version 1.0
recycled paper

üIncorrect installation can cause serious injuries.
üKeep these instructions for future maintenance operations and the disposal of the product.
üAll the product installation, connection, programming and maintenance operations must be carried out only by a qualified and skilled technician, who must
comply with laws, provisions and local regulations, and the instructions provided herein.
üWiring must comply with current CEI standards. In compliance with the provisions of Italian Ministerial Decree 37/2008, the final electrical system must be
installed only by an electrician.
üSome applications require “man present” operation and can exclude the use of radio commands or require particular safety devices.
üTo prevent potentially dangerous situations, regularly check the operating condition of the rolling shutter/awning.
01.1 SAFETY WARNINGS
01. WARNINGS. WARNING! Importanti istruzioni di sicurezza!
üRead the technical specifications in paragraph “Technical Specifications” to evaluate the operating parameters of the product.
üBefore installing the product, check compatibility with associated devices and accessories.
üThe motor connected to the device must be of the “mechanical limit switch” type, without any electronic control; the motor must be of power adequate to the
charge (check the rating plate data on the motor).
üCheck that the package is intact and has not been damaged during transport.
üA heavy shock, falls, crushing and the use of unsuitable tools can cause the damage of the external or internal parts of the product.
üDo not pierce or tamper with the product in any way. Do not modify or replace parts without the Manufacturer's permission.
üCheck that the location selected for product installation enables the blades to be exposed to the same wind to which the rolling shutter to be motorized is
exposed.
üCheck that the installation location is made of solid materials and can ensure a stable installation.
üDo not install the product near heat sources (such as chimneys, etc....).
üAdjust the control unit inclination so that blades are positioned horizontally.
üThe wind detection blades must face downward. The blades must be free to rotate without obstruction.
üCheck that the control unit is placed in a protected position from accidental impact with other objects (e.g. branches, etc.).
üThe power cable must be positioned in such a way as to avoid contact with moving parts.
üDo not use abrasive or solvent products for cleaning the device; do not clean using water-jet or high-pressure cleaners.
üFor your safety, do not work near the coiler while the motor is powered.
01.2 INSTALLATION WARNINGS
üThe product is not intended to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they are supervised or given instructions about the product way of use by a person responsible for their safety.
üCheck automation during operation and keep people at a safe distance, until operation ends.
üDo not allow children to play with the appliance or with the fixed control devices.
üDo not operate the rolling shutter when maintenance operations are being carried out (e.g. window cleaning, etc.). If the control device is automatic,
disconnect the motor from the power line.
01.3 USE WARNINGS
This sensor does not protect shutters in case of strong and sudden wind gusts.
In case of weather hazards of this type, make sure that shutters remain closed! Stafer S.p.A.
declines all liability for damage incurred due to weather events not detected by the device.
Any other use beyond the field defined by Stafer S.p.A. is prohibited and involves, as well as the failure to comply with instructions provided in this guide,
voidance of Stafer S.p.A.'s liability and warranty. The installer, after the installation of the product, must train the end user about the use of the automation and
provide him with the User and maintenance manual.
WARNING!!
STAFER uses recyclable packaging materials. Dispose of materials in
proper containers, in compliance with laws in force in your location.
If you are an installer and use a large number of motors, ask your dealer
about receiving motors in “honeycomb pads”, an environmentally friendly
choice that limits clutter and waste by reducing the amount of packaging
materials.
This product may have substances that are polluting for the
environment and dangerous for the health. At the end of the
product life cycle, carefully comply with local waste disposal
rules. It is strictly forbidden to dispose of the product in the
domestic waste.
Let's protect the environment!
01 Warnings page 01
02 Assembly instructions page 02
03 Electrical connections page 03
04 Interfacing with home automation control units page 04
05 WIND sensor page 04
05.1 How to change the wind threshold
05.2 Visual LED signals associated with the wind sensor
05.3 Forced exit from the wind alarm
06 SUN function page 05
06.1 Activation/deactivation of “sun” function
06.2 How to change the sun threshold
06.3 Visual LED signals associated with the “sun” function
07 Automatic lowering function after wind alarm page 06
08 Operating logic of command buttons page 06
09 Anemometric test function page 07
10 Anemometer check on awning status page 07
11 Factory values reset page 07
Index
ü Power supply: 120 or 230 Vac, 50/60 Hz
ü Dimensions: 240 x 60 x H.111/133 mm
ü Weight: 230 g
ü Operating temperature: from –20 to +55 °C
ü Protecnion degree: IP 55
ü Wind threshold: from 5 to 35 km/h
ü Sun threshold: from 1 to 45 Klux
Technical specifications
Dear Customer, thank you for purchasing a Stafer S.p.A. product. This guide contains information about the use of the product. Before installing and using the
product, please read this guide carefully and keep it for future reference.
595.K.F2.00 is a sun/wind sensor designed to operate tubular motors with mechanical limit switch powered by main voltage, and suitable to operate awnings,
blinds or similar products. 595.K.F2.00 allows operating the automatic retraction of rolling shutters connected to the motor when the wind exceeds the set
threshold, as well as their release when the intensity of sun exceeds the set threshold. These thresholds are set by the factory, but they can be adjusted
according to the needs.
595.K.F2.00
01

02. ASSEMBLY INSTRUCTIONS
X
Components key:
(1) Impeller
(2) Anemometer body
(3) Support fastening screw
(4) Wall fastening support
(5) Rubber cable entry
02.2 FASTENING SYSTEMS
02.3 ASSEMBLY INSTRUCTIONS
Notes:
üthe product has been designed to be installed with blades facing downward. Moreover, the sensor body must be adjusted horizontally.
üthe bore interaxis is 25 mm.
ü as soon as the anemometer is powered, the three coloured LEDs will briefly flash 3 times.
02
02.1 LED DIAGRAM
Green
LED
Yellow
LED
Red
LED
Close the case by tightening the
screws.
D
Unscrew the 3 screws and open the
upper case.
A
Fasten the wall support to the wall
or ceiling based on your needs.
E
Punch the rubber cable entry and
insert the cable.
B
Fasten the anemometer back into
the coupling.
F
Connect the cable to the terminals
based on the number of motors.
C

03. ELECTRICAL CONNECTION
üMake all connections with the power supply disconnected.
üCheck that the power line does not feed on electrical circuits to be used for lighting.
üAlways connect the motor to the grounding system (yellow/green).
üThe power line must be equipped with a magnetothermal or differential circuit breaker. A category III overvoltage disconnection device must be
fitted on the power supply line, i.e. at a distance of at least 3.5 mm between the contacts.
üThe product does not provide for any protection against overloads or short circuits. Provide adequate protection for the load on the power supply
line, for example a fuse with a maximum value of 3.15 A (for 1 motor) or 6.3A (for 2 motors).
üThe section of the connecting cables must be proportionate to their length and to the power load absorption, and, in any case, not less than 1.5
mm.
üYou must use command buttons with spring return (“man present” type), do NOT use switches with maintained position.
üCommand buttons are connected to the main voltage, so they must be properly insulated and protected.
üOnce the electrical connections are finished, bring the motor/motors to intermediate position and check that in the “wind alarm”
condition the module controls the upward movement of the motor/motors (to exit the “wind alarm”, disconnect power for a few seconds).
03
1 MOTOR CONNECTION
2 MOTORS CONNECTION
MAIN POWER
SUPPLY
L
N
MECHANICAL
MOTOR 1
MECHANICAL
MOTOR 2
BUTTON 1
BUTTON 2
ANEMOMETER
TERMINAL BOARD
maneuver
maneuver
maneuver
blue
yellow/green
yellow/green
blue
maneuver
blue
yellow/green
maneuver
maneuver
up
down
up
down
3.15 A fuse
3.15 A fuse
yellow/green
blue
MAIN POWER
SUPPLY
L
N
maneuver
maneuver
down
BUTTON 1
MECHANICAL
MOTOR 1
blue
ANEMOMETER
TERMINAL BOARD
up

üThis device can be interfaced to the most widespread home automation control units through the wires of the command buttons (it is still necessary to check
beforehand the compatibility, assessing whether the home automation control unit is able to provide appropriate signals to the device).
üWarning: Before making any connections between your device and the home automation control unit you need to choose the operating logic of the buttons
that will best suit your home automation system (“pulse” or “man present” logic, see section 8 “Operating logic of command buttons”).
ü If you select the “pulse” operating logic (factory setting), the home automation control unit must be able to generate timed signals on the contacts for the
buttons (greater than 0.5 sec to start the manoeuvre, less than 0.5 sec to stop the manoeuvre). If your home automation system does not have this feature,
you must set the device to operate in “man present” logic.
üNote that the OPEN and CLOSE contacts of the home automation control unit, connected to the wires of the command buttons on the device, must close on
phase.
04. INTERFACING WITH HOME AUTOMATION CONTROL UNITS
2 x UP
1 x DOWN
3 x UP
3 x DOWN
5 Km/h
1 x UP
10 Km/h
2 x UP
15 Km/h
3 x UP
25 Km/h
4 x UP
35 Km/h
5 x UP
If you try to set a wind threshold higher than 35 Km/h,
the value rejects the operation and completes 4 short
up/down movements.
If wind speed is above the set threshold for at least 15 seconds, an upward movement is activated to protect the awning (wind alarm). During this phase, all
manual commands are disabled. The control unit exits the “wind alarm” if the wind speed keeps below the set threshold for at least 5 minutes. The wind
threshold ranges from 5 km/h to 35 km/h. The factory sets the wind threshold at level 2.
05. WIND SENSOR
05.1 HOW TO CHANGE THE WIND THRESHOLD
Within 15 seconds
press 3 times on
UP and 3 times on
DOWN.
C(1)
Within 15 seconds
press twice on UP
and once on
DOWN.
E(1)
the motor shows the
current setting (from 1
to 5 movements).
WITHIN 15 SECONDS, SELECT THE DESIRED SETTING
BY PRESSING UP FROM 1 TO 5 TIMES
C
D
G
The motor shows
the new setting
(from 1 to 5
movements).
See Tab. 01
H
No. of movements Threshold
1
2
3
4
5
5 km/h
10 Km/h
15 Km/h
25 Km/h
35 Km/h
Tab. 01 - Wind threshold
OFF
ON
Switch OFF power supply for
few seconds, then switch it
ON again.
B
It is possible to exit the “wind alarm” mode without waiting for the 5 minutes required for the wind to go below the threshold, removing voltage from the device
and waiting a few seconds before switching on again.
05.3 FORCED EXIT FROM THE WIND ALARM
05.2 VISUAL LED SIGNALS ASSOCIATED WITH THE WIND SENSOR
Bring the motor to the
intermediate position.
A
The motor completes
1 up/down movement.
D
04
F
Notes:
1) Button must be pressed shortly, approx. 1 second between two pressures.
2) Button must be pressed shortly, approx. 1 second between two pressures. If you do not want
to change the setting, wait 15 seconds without pressing any button.
(2)
YELLOW LED on steady: the sun function is active (regardless of awning position).
YELLOW LED off: the sun function is not active (regardless of awning position).
RED + YELLOW LED flashing: anemometer out of order following the “anemometer test” (see paragraph 7)
RED LED flashing: anemometer in wind alarm mode

1 Klux
1 x SALITA (UP)
8 Klux
2 x SALITA (UP)
15 Klux
3 x SALITA (UP)
22 Klux
4 x SALITA (UP)
45 Klux
5 x SALITA (UP)
06.2 HOW TO ADJUST THE “SUN” THRESHOLD
WITHIN 15 SECONDS SELECT THE DESIRED SETTING
BY PRESSING UP FROM 1 TO 6 TIMES
C
D
G
Tab. 02 - Sun threshold If you try to set a wind threshold lower or greater
than 5, the value is rejected and the system
completes 4 short up/down movements.
05
2 x UP
3 x DOWN
3 x UP
3 x DOWN
Within 15 seconds
press 3 times on
UP and 3 times on
DOWN.
C(1)
Within 15 seconds
press twice on UP
and once on
DOWN.
E(2)
the motor shows the
current setting (from 1
to 5 movements).
OFF
ON
Switch OFF power supply for
few seconds, then switch it
ON again.
B
Bring the motor to the
intermediate position.
A
The motor completes
1 up/down movement.
D F
The motor shows
the new setting
(from 1 to 5
movements).
See Tab. 01
H
06.3 VISUAL LED SIGNALS ASSOCIATED WITH THE SUN SENSOR
YELLOW LED on steady: the sun function is active (regardless of awning position).
YELLOW LED off: the sun function is not active (regardless of awning position).
RED + YELLOW LED flashing: anemometer out of order following the “anemometer test” (see paragraph 7)
RED LED flashing: anemometer in wind alarm mode
06.1 ACTIVATION/DEACTIVATION OF “SUN” FUNCTION
2 x UP
2 x DOWN
3 x UP
3 x DOWN
Within 15 seconds
press 3 times on
UP and 3 times on
DOWN.
C(1)
Within 15 seconds
press twice on UP
and once on
DOWN.
E(1)
The motor completes
1 up/down movement.
OFF
ON
Switch OFF power supply for
few seconds, then switch it
ON again.
B
Bring the motor to the
intermediate position.
A
The motor completes
1 up/down movement.
D F
No. of movements
Threshold
1
Lev. 1
2
Lev. 2
3
Lev. 3
4 5
Lev. 4 Lev. 5
1 x UP
To ACTIVATE the
sun function:
G
1 x DOWN
To DEACTIVATE
the sun function:
The motor replicates
the up or down
movement.
H
After 5 seconds, the
motor exits the menu
without signal.
I
After 5 seconds, the
motor exits the
menu without
signal.
I
Notes:
ü(1) Button must be pressed shortly, approx. 1 second between two pressures.
Notes:
ü(1) Button must be pressed shortly, approx. 1 second between two pressures.
The “sun” function allows the awning to move automatically according to sun exposure, based on brightness measured by the light sensor installed on the
anemometer. This function is deactivated by default and can be activated at a later time. If the intensity of the sun is above the set threshold for at least 2
minutes, an automatic downward manoeuvre is performed; if the intensity of the sun is below the set threshold for at least 15 minutes, an automatic upward
manoeuvre is performed. Once an automatic downward manoeuvre for the presence of the sun is performed, the next automatic manoeuvre performed by the
control unit will be an upward movement for absence of sun and so on. The user can, in any case, operate the awning, without the manual command affecting
the operating logic of the sun sensor. The sun threshold ranges from 1 to 45 Klux. The factory sets the sun threshold to level 2. In the event of a wind alarm, the
awning will be closed whether or not any sun is shining.
06. SUN FUNCTION
(very sensitive)
(not very sensitive)

This device allows lowering the awning automatically after it retracted due to a wind alarm.
After 5 minutes without wind, either of two situations can occur:
- If the sun sensor was activated, it will re-open the awning only if the awning was open when the wind was detected (if it was already closed, it will remain
closed).
- If the sun sensor was deactivated, the awning will be automatically re-opened only if it was open when the wind was detected (if it was already closed, it will
remain closed).
The automatic lowering function can be activated or deactivated. The factory sets it on ACTIVE mode. To change it, follow the procedure below.
07. AUTOMATIC LOWERING FUNCTION AFTER WIND ALARM
Notes:
ü(1) Button must be pressed shortly, approx. 1 second between two pressures.
The motor shows the current
setting.
The motor signals the
new setting.
F H
1 UP
Function
active
1 DOWN
Function
NOT active
x1 x1
x1 x1
WITHIN 5 SECONDS SELECT THE
DESIRED SETTING BY PRESSING
“To deactivate it”
“To activate”
PRESS UP PRESS DOWN
G
2 x UP
4 x DOWN
3 x UP
3 x DOWN
Within 15 seconds
press 3 times on UP
and 3 times on
DOWN.
C(1)
Within 15 seconds
press twice on UP and
4 times on DOWN.
E(1)
OFF
ON
Switch OFF power supply for
few seconds, then switch it
ON again.
B
Bring the motor to the
intermediate position.
A
The motor completes
1 up/down movement.
D
After 5 seconds, it
exits the menu.
I
1 UP
Function
active
1 DOWN
Function
NOT active
This device provides the possibility to choose one of the following operating logics for the command buttons:
“Pulse” logic
This is the default mode from the factory. The motor moves up (down) if the relevant contact is closed on phase for at least 0.5 sec, the motor will stop if any one
of the two contacts is closed briefly (less than 0.5 sec).
“Man present” logic
The motor moves up (down) if the relevant contact is closed on phase for at least 0.5 sec, the motor stops when contact is open.
08. OPERATING LOGIC OF COMMAND BUTTONS
Notes:
ü(1) Button must be pressed shortly, approx. 1 second between two pressures.
The motor shows the current
setting.
The motor signals the new
setting.
F H
«Man
present»
«Man
present»
«Pulse» «Pulse»
x1 x1
x1 x1
WITHIN 15 SECONDS SELECT THE
DESIRED SETTING BY PRESSING
«Pulse»
«Man present»
PRESS UP PRESS DOWN
G
4 x DOWN
3 x UP
3 x DOWN
Within 15 seconds
press 3 times on UP
and 3 times on
DOWN.
C(1)
Within 15 seconds,
press DOWN 4 times.
E(1)
OFF
ON
Switch OFF power supply for
few seconds, then switch it
ON again.
B
Bring the motor to the
intermediate position.
A
The motor completes
1 up/down movement.
D
After 5 seconds, it
exits the menu.
I
06

07
11. FACTORY VALUE RESET
The motor performs two
brief upward movements
to indicate that it was
reset.
H
All rights reserved.
STAFER S.p.a. - via Malpighi, 9 - 48018 Faenza (RA) ITALY
Tel. (+39) 0546.624811 - Fax (+39) 0546.623141 - www.stafer.com
All products and technical specifications given in this document are subject to variation without prior notice.
Unless previously and specifically authorised by STAFER, the device must be used exclusively with transmitters produced by STAFER.
STAFER cannot be considered responsible for damage caused by improper, incorrect or unreasonable uses.
2 x UP
8 x DOWN
3 x UP
3 x DOWN
Within 15 seconds
press 3 times on
UP and 3 times on
DOWN.
C(1)
Within 15 seconds
press twice on UP
and once on
DOWN.
E(1)
the motor performs 6
up/down movements
OFF
ON
Switch OFF power supply for
few seconds, then switch it
ON again.
B
Bring the motor to the
intermediate position.
A
The motor completes
1 up/down movement.
D F
When the anemometer is reset, all settings will return to factory values.
2 x UP
Within 5 seconds,
press UP twice
G(1)
Notes:
ü(1) Button must be pressed shortly, approx. 1 second between two pressures.
The device is provided with a diagnosis function of the wind sensor. If, for about 24 hours the wind sensor does not generate any valid pulse, the sensor
commands an automatic upward manoeuvre of the awning, suspends all other activities and indicates the fault by flashing the LEDs. The device will come out
of this state resuming normal activities only when the anemometer generates a valid pulse. To exit the alarm, remove and restore power. The function cannot be
deactivated.
09. ANEMOMETRIC TEST FUNCTION
10. ANEMOMETER CHECK ON AWNING STATUS
If the motor does not respond to the button commands, it is because some alarm has been activated. To understand the type of alarm, look at the colour of the
LEDs under the anemometer. Alternatively, it is also possible to “ask” the anemometer about the alarm status. The device will order the motor to perform some
movements corresponding to the active alarm. Proceed as follows.
01. Remove and restore power.
02. Press UP 3 times and DOWN 3 times*. The motor shows:
up/down.
03. Press twice on UP and 5 times on DOWN. After 2 seconds, the
motor provides information on the awning's current status. See
table 3.
04. After 5 seconds, the motor returns to its initial position.
05. Wait for 10 seconds. The motor exits the menu without signalling.
USING THE WALL-MOUNTED BUTTON
No. of
movements Alarm
2 lowering
3 x up
5 lowering
wind alarm
sun active
stopped due to
anemometric
test
Tab. 03 - Alarm status
Awning
position
Closed
Open
Closed
(*) The buttons must be pressed shortly, max 1 second between two pressures.
Table of contents
Other Stafer Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Baumer
Baumer GCA5 C8 manual

PPS
PPS PPS71 user manual

York Survey Supply
York Survey Supply 33235 operating instructions

Hilti
Hilti PS 85 Original operating instructions

National Instruments
National Instruments PXIe-5622 CALIBRATION PROCEDURE

Etatron
Etatron eSelect M 1 CD COOL Operating instructions and maintenance