Vertex Standard Co., Ltd.
HX600S Alignment
The HX600S has been carefully aligned at the factory for the specified performance
across the land mobile band.
Realignment should therefore not be necessary except in the event of a component
failure.
All component replacement and service should be performed only by an authorized
STANDARD HORIZON representative, or the warranty policy may be voided.
The following procedures cover the sometimes critical and tedious adjustments that are
not normally required once the transceiver has left the factory. However, if damage occurs
and some parts are replaced, realignment may be required. If a sudden problem occurs
during normal operation, it is likely due to component failure; realignment should not be
done until after the faulty component has been replaced.
We recommend that servicing be performed only by authorized STANDARD HORIZON
service technicians who are experienced with the circuitry and fully equipped for repair and
alignment. Therefore, if a fault is suspected, contact the dealer from whom the transceiver
was purchased for instructions regarding repair. Authorized STANDARD HORIZON service
technicians realign all circuits and make complete performance checks to ensure
compliance with factory specifications after replacing any faulty components. Those who do
undertake any of the following alignments are cautioned to proceed at their own risk.
Problems caused by unauthorized attempts at realignment are not covered by the
warranty policy. Also, STANDARD HORIZON must reserve the right to change circuits and
alignment procedures in the interest of improved performance, without notifying owners.
Under no circumstances should any alignment be attempted unless the normal function
and operation of the transceiver are clearly understood, the cause of the malfunction has
been clearly pinpointed and any faulty components replaced, and the need for realignment
determined to be absolutely necessary. The following test equipment (and thorough
familiarity with its correct use) is necessary for complete realignment. Correction of
problems caused by misalignment resulting from use of improper test equipment is not
covered under the warranty policy. While most steps do not require all of the equipment
listed, the interactions of some adjustments may require that more complex adjustments be
performed afterwards. Do not attempt to perform only a single step unless it is clearly
isolated electrically from all other steps. Have all test equipment ready before beginning,
and follow all of the steps in a section in the order presented.
Required Test Equipment
ο Radio Tester with calibrated output level at 200 MHz
ο In-line Wattmeter with 5% accuracy at 200 MHz
ο 50 Ω, 10 W RF Dummy Load
ο Regulated DC Power Supply adjustable from 3 to 15 VDC, 2A
ο Frequency Counter: ±0.2 ppm accuracy at 200 MHz
ο AF Signal Generator
ο AC Voltmeter
ο DC Voltmeter: high impedance
ο VHF Sampling Coupler
Alignment Preparation & Precautions
A 50 ΩRF load and in-line wattmeter must be connected to the main antenna jack in all
procedures that call for transmission, except where specified otherwise. Correct alignment
is not possible with an antenna. After completing one step, read the next step to see if the
same test equipment is required. If not, remove the test equipment (except dummy load
and wattmeter, if connected) before proceeding.
Correct alignment requires that the ambient temperature be the same as that of the
transceiver and test equipment, and that this temperature be held constant between 20 ~

FCC ID: K6630193X20
IC ID: 511B-30193X20
Alignment
2/5
Vertex Standard Co., Ltd.
30 °C (68 ~ 86 °F). When the transceiver is brought into the shop from hot or cold air, it
should be allowed some time to come to room temperature before alignment. Whenever
possible, alignments should be made with oscillator shields and circuit boards firmly affixed
in place. Also, the test equipment must be thoroughly warmed up before beginning.
Set up the test equipment as shown below for transceiver alignment, apply 7.2 VDC power
to the transceiver.
Notes: signal levels in dB referred to in alignment are based on 0 dBµ = 0.5 µV
(closed circuit).
PLL Section
PLL Reference Frequency
Connect the wattmeter, dummy load, and frequency counter to the antenna jack.
Set the transceiver to CH16 (156.800 MHz) then turn the transceiver off.
Press and hold in the PTT key, MONI key, [▲] and [▼] key while turn the transceiver
on to enter the alignment mode.
Press the [▼] or [▲] key to select the display to [REF xx].
Press the [MEM] key to enable adjustment of the PLL Reference Frequency.
Press the PTT key to transmit the transceiver, if necessary, press the [▼] or [▲] key to
adjust the frequency so the counter frequency is 156.800 MHz (±100 Hz).
Press the [MEM] key to exit this Alignment Mode.
Press and hold the [PWR] key for 2 seconds to exit to the normal operation.
Receiver Section (Marine Band)
Squelch Hysteresis Adjustment
Connect the Radio Tester to the antenna jack.
Set the transceiver to CH16 (156.800 MHz) then turn the transceiver off.
Press and hold in the PTT key, MONI key, [▲] and [▼] key while turn the transceiver
on to enter the alignment mode.
Press the [▼] or [▲] key to select the display to [FM HS xx].
Press the [MEM] key to enable adjustment of this Alignment Mode.
Press the [▼] or [▲] key to adjust the hysteresis level.
Press the [MEM] key to exit this Alignment Mode.
Squelch Threshold Adjustment
Adjust the Radio Tester output level -13 dBµ (with a standard FM modulation: ±3.0 kHz
deviation @ 1 kHz) at 156.800 MHz.
Press the [▼] or [▲] key to select the display to [FM TH xx].
Press the [MEM] key to read the Squelch Threshold data.
Press the [MEM] key again to save the new setting.
Squelch Tight Adjustment
Adjust the Radio Tester output level +5 dBµ (with a standard FM modulation: ±3.0 kHz
deviation @ 1 kHz) at 156.800 MHz.
Press the [▼] or [▲] key to select the display to [FM TI xxx].
Press the [MEM] key to read the Squelch Tight data.
Press the [MEM] key again to save the new setting.
Press and hold the [PWR] key for 2 seconds to exit to the normal operation.
Transmitter Section
TX Power Adjustment (Hi Power)
Connect the wattmeter and dummy load to the antenna jack.

FCC ID: K6630193X20
IC ID: 511B-30193X20
Alignment
3/5
Vertex Standard Co., Ltd.
Set the transceiver to CH16 (156.800 MHz) with “high” power mode, and then turn the
transceiver off.
Press and hold in the PTT key, MONI key, [▲] and [▼] key while turn the transceiver
on to enter the alignment mode.
Press the [▼] or [▲] key to select the display to [HPOW xx].
Press the [MEM] key to enable adjustment of this Alignment Mode.
Press the PTT key to transmit the transceiver, if necessary, press the [▼] or [▲] key to
adjust the output power to 5.0 W (±0.3 W).
Press the [MEM] key to exit this Alignment Mode.
Press and hold the [PWR] key for 2 seconds to exit to the normal operation.
TX Power Adjustment (Medium Power)
Connect the wattmeter and dummy load to the antenna jack.
Set the transceiver to CH16 (156.800 MHz) with “Medium” power mode, and then turn
the transceiver off.
Press and hold in the PTT key, MONI key, [▲] and [▼] key while turn the transceiver
on to enter the alignment mode.
Press the [▼] or [▲] key to select the display to [MPOW xx]
Press the [MEM] key to enable adjustment of this Alignment Mode.
Press the PTT key to transmit the transceiver, if necessary, press the [▼] or [▲] key to
adjust the output power to 2.5 W (±0.2 W).
Press the [MEM] key to exit this Alignment Mode.
Press and hold the [PWR] key for 2 seconds to exit to the normal operation.
TX Power Adjustment (Low Power)
Connect the wattmeter and dummy load to the antenna jack.
Set the transceiver to CH16 (156.800 MHz) with “Low” power mode, and then turn the
transceiver off.
Press and hold in the PTT key, MONI key, [▲] and [▼] key while turn the transceiver
on to enter the alignment mode.
Press the [▼] or [▲] key to select the display to [LPOW xx]
Press the [MEM] key to enable adjustment of this Alignment Mode.
Press the PTT key to transmit the transceiver, if necessary, press the [▼] or [▲] key to
adjust the output power to 1.0 W (±0.1 W).
Press the [MEM] key to exit this Alignment Mode.
Tx Deviation Adjustment
Connect the Radio Tester to the antenna jack, and then adjust the Audio generator
output to 100 mV at 1 kHz.
Press the [▼] or [▲] key to select the display to [MOD xx].
Press the [MEM] key to enable adjustment of this Alignment Mode.
Press the PTT key to transmit the transceiver, if necessary, press the [▼] or [▲] key to
adjust the deviation to 4.2 kHz (±0.2 kHz).
Press the [MEM] key to exit this Alignment Mode.
Tx Deviation Adjustment (DSC Deviation)
Connect the Radio Tester to the antenna jack
Press the [▼] or [▲] key to select the display to [FSK 0 xx].
Press the PTT key to transmit the transceiver with no microphone input, confirm that
the deviation meter reading is 3.8 kHz (±0.1 kHz).
If not,
1. Press the [▼] or [▲] key to select the display to [DS FSK xx].

FCC ID: K6630193X20
IC ID: 511B-30193X20
Alignment
4/5
Vertex Standard Co., Ltd.
2. Press the [MEM] key to enable adjustment of this Alignment Mode.
3. Press the [▼] or [▲] key to adjust the deviation level.
4. Press the [MEM] key to exit this Alignment Mode.
5. Press the [▼] or [▲] key to select the display to [FSK 0 xx], then confirm the
deviation meter reading.
6. Repeat above steps 1 - 5, so that the deviation meter reading is 3.8 kHz (±0.1
kHz).
Press and hold the [PWR] key for 2 seconds to exit to the normal operation.
Receiver Section (FM Broadcast Band)
Squelch Hysteresis Adjustment
Connect the Radio Tester to the antenna jack.
Set the transceiver to 98.000 MHz, and then turn the transceiver off.
Press and hold in the PTT key, MONI key, [▲] and [▼] key while turn the transceiver
on to enter the alignment mode.
Press the [▼] or [▲] key to select the display to [WFM HS xx].
Press the [MEM] key to enable adjustment of this Alignment Mode.
Press the [▼] or [▲] key to adjust the hysteresis level.
Press the [MEM] key to exit this Alignment Mode.
Squelch Threshold Adjustment
Adjust the Radio Tester output level +4 dBµ (with a standard FM modulation: ±22.5
kHz deviation @ 1 kHz) at 98.000 MHz.
Press the [▼] or [▲] key to select the display to [WFM TH xx].
Press the [MEM] key to read the Squelch Threshold data.
Press the [MEM] key again to save the new setting.
Squelch Tight Adjustment
Adjust the Radio Tester output level +14 dBµ (with a standard FM modulation: ±22.5
kHz deviation @ 1 kHz) at 98.000 MHz.
Press the [▼] or [▲] key to select the display to [WFM TI xx].
Press the [MEM] key to read the Squelch Tight data.
Press the [MEM] key again to save the new setting.
Press and hold the [PWR] key for 2 seconds to exit to the normal operation.
Receiver Section (AM Broadcast Band)
Squelch Hysteresis Adjustment
Connect the Radio Tester to the antenna jack.
Set the transceiver to 1.100 MHz, and then turn the transceiver off.
Press and hold in the PTT key, MONI key, [▲] and [▼] key while turn the transceiver
on to enter the alignment mode.
Press the [▼] or [▲] key to select the display to [AM HS xx].
Press the [MEM] key to enable adjustment of this Alignment Mode.
Press the [▼] or [▲] key to adjust the hysteresis level.
Press the [MEM] key to exit this Alignment Mode.
Squelch Threshold Adjustment
Adjust the Radio Tester output level -8 dBµ (with a standard AM modulation: 30 % AM
modulation @ 1 kHz) at 1.100 MHz.
Press the [▼] or [▲] key to select the display to [AM TH xxx].
Press the [MEM] key to read the Squelch Threshold data.
Press the [MEM] key again to save the new setting.

FCC ID: K6630193X20
IC ID: 511B-30193X20
Alignment
5/5
Vertex Standard Co., Ltd.
Squelch Tight Adjustment
Adjust the Radio Tester output level +2 dBµ (with a standard AM modulation: 30 % AM
modulation @ 1 kHz) at 1.100 MHz.
Press the [▼] or [▲] key to select the display to [AM TI xxx].
Press the [MEM] key to read the Squelch Tight data.
Press the [MEM] key again to save the new setting.
Press and hold the [PWR] key for 2 seconds to exit to the normal operation.
TX DSC Testing Mode
2100 Hz Single Tone (Continual)
Connect the Radio Tester to the antenna jack.
Set the transceiver to 156.800 MHz and turn the transceiver off.
Press and hold in the PTT key, MONI key, [▲] and [▼] key while turn the transceiver
on to enter the alignment mode.
Press the [▼] or [▲] key to select the display to [FSK 0 xx].
Press the PTT key to transmit the transceiver.
1300 Hz Single Tone (Continual)
Press the [▼] or [▲] key to select the display to [FSK 1 xx].
Press the PTT key to transmit the transceiver.
1300 Hz & 2100 Hz Dot Pattern (Sequential)
Press the [▼] or [▲] key to select the display to [FSK 2 xx].
Press the PTT key to transmit the transceiver.
Press and hold the [PWR] key for 2 seconds to exit to the normal operation.