Star FL3X 1000BASE-T1 User manual

FL3X Switch 1000BASE-T1
Instructions for Use

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 2 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
Contact Information
STAR ELECTRONICS GmbH & Co. KG
A Company of the STAR COOPERATION Group
Jahnstraße 86
73037 Goeppingen
Phone: +49 (0)7031 6288-5656
Phone: +49 (0)7031 6288-5330 (Support)
Sales: sales-ee@star-cooperation.com
Support: support-ee@star-cooperation.com
www.flex-product.com
Company Data
STAR ELECTRONICS GmbH & Co. KG, registered office: Göppingen, register court Ulm, HRA 721096
Partner liable to unlimited extent: STAR ELECTRONICS Verwaltungs-GmbH, registered office: Göppingen, register
court Ulm, HRB 722565
Represented by the executive board: Rolf Wittig, Henning Lange
Copyright Notice
© Copyright 2023 STAR ELECTRONICS GmbH & Co. KG. All rights reserved.
No part of this document may be reproduced in any form (photocopy, microfilm or another procedure) without
prior written consent from STAR ELECTRONICS GmbH & Co. KG.
Trademarks
All trademarks used in this document are the property of their respective owners.

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 3 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
Disclaimer
The information contained in this document does not affect or change General Terms and Conditions of STAR
ELECTRONICS GmbH & Co. KG. STAR ELECTRONICS GmbH & Co. KG does not guarantee the completeness and
accuracy of the content of this document and assumes no responsibility for any errors which may appear in this
document or due to this document. The content of this document or the associated products are subject to
change without notice at any time.
It is currently impossible to develop software that is bug-free in all applications. Therefore, the product is only
allowed to be used in the sense of the product use case described herein.
STAR ELECTRONICS GmbH & Co. KG makes no warranty express or implied, as to this document or the
information content, materials or products for any particular purpose, nor does STAR ELECTRONICS GmbH & Co.
KG assume any liability arising out of the application or use of this product, and disclaims all liabilities, including
without limitation resulting damages, as permissible by applicable law.
All operating parameters which are provided in this document can vary in different applications or over time. The
herein described product, may solely be used as described in chapter 1.2 “Intended use”.
Without limiting the rights under copyright, no part of this document may be reproduced, stored in or introduced
into a retrieval system, or transmitted in any form or by any means (electronic, mechanical, photocopying,
recording, or otherwise), or for any purpose, without the express written consent of STAR ELECTRONICS GmbH &
Co. KG.
STAR ELECTRONICS GmbH & Co. KG may have patents, patent applications, trademarks, copyrights, or other
intellectual property rights covering subject matter in this document. Except as expressly stated in a written
license agreement from STAR ELECTRONICS GmbH & Co. KG the furnishing of this document does not give you
any license to these patents, trademarks, copyrights, or other intellectual property.
Any semiconductor devices have an inherent chance of failure. You must protect against injury, damage or loss
from such failures by incorporating safety design measures into your facility and equipment such as redundancy,
fire protection, and prevention of over-current levels and other abnormal operating conditions.
The safety and handling instructions in this document must be followed strictly.
EC Conformity
The FL3X Switch 1000BASE-T1 complies with the essential requirements of the following applicable European
Community Directive(s) including current amendments, and carries the CE marking accordingly:
2014/30/EU EMC Directive
The following standard(s) have been used to assess the product:
EN 61000-4-2:2009
EN 61000-4-3:2006 + A1:2008 + A2:2010
EN 61000-4-4:2012
EN 61000-4-5:2014 + A1:2017
EN 61000-4-6:2014
EN IEC 61000-6-2:2019
EN 61000-6-3:2007 + A1:2011
EN 61326-1:2013
EN 55011:2016 + A1:2017
This product is compliant with the European Community Directive 2011/65/EC on the restriction of the use of
certain hazardous substances in electrical and electronic equipment (RoHS).

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 4 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
UK Conformity
The FL3X Switch 1000BASE-T1 complies with the essential requirements of the following applicable UK Regulations
including current amendments, and carries the UK marking accordingly:
2016 Electromagnetic Compatibility Regulations
The following standard(s) have been used to assess the product:
EN 61000-4-2:2009
EN 61000-4-3:2006 + A1:2008 + A2:2010
EN 61000-4-4:2012
EN 61000-4-5:2014 + A1:2017
EN 61000-4-6:2014
EN IEC 61000-6-2:2019
EN 61000-6-3:2007 + A1:2011
EN 61326-1:2013
EN 55011:2016 + A1:2017
This product is compliant with “the Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012”.
Revision History
Document number: 3-0103-0A01-D11
Version
Date
Description
D1V0-5 23.03.2021 Preliminary Release
D1V0-F 21.10.2021 First Release
D1V1-F 16.02.2022 Updated chapter EC Conformity
Added chapter UK Conformity
D1V2-F 10.06.2022 First steps added
D1V3-F 15.07.2022 First steps updated
D1V4-F 07.11.2022 FirmwareUpdate added, hint Harting T1 Rev1 only
D1V5-F 20.02.2023 Product renaming
D1V6-F 26.07.2023 Rev.2 Hardware added
Related Hardware / Software Versions
Product
Reference No.
Version
Remarks
FL3X Switch 1000BASE-T1 3-0103-0A01 01 No longer available
Old product name:
FlexSwitch 1000BASE-T1
FL3X Switch 1000BASE-T1
Rev.2
3-0103-0B02 01 -

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 5 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
Contents
1General ..................................................................................................................................................6
1.1 Intended User Group............................................................................................................................6
1.2 Intended Use .......................................................................................................................................6
1.3 Used Pictograms..................................................................................................................................7
1.4 Safety and Handling Instructions..........................................................................................................7
1.5 Meaning of Text Styles .........................................................................................................................8
2Product Description ..............................................................................................................................9
2.1 FL3X Switch 1000BASE-T1 at a glance .................................................................................................9
2.2 Accessory Parts ...................................................................................................................................9
3First steps........................................................................................................................................... 10
4Technical Data.................................................................................................................................... 11
4.1 Electrical Characteristics ...................................................................................................................11
4.2 Physical Characteristics .....................................................................................................................11
4.3 Environmental Conditions ..................................................................................................................11
4.4 Interfaces ..........................................................................................................................................11
4.4.1 Power connector (Binder) and LED .....................................................................................................12
4.4.2 Ethernet Con 1 – 7 (SPE T1 IEC 63171-6) and LEDs ...........................................................................13
4.4.3 Ethernet Con 9 and 10 (SFP+ module)................................................................................................14
4.4.4 RMU Port (Remote Management Unit) ................................................................................................14
5Getting Started................................................................................................................................... 15
5.1 Assembly and Line-up ........................................................................................................................15
5.2 Configuration and Operation ..............................................................................................................15
6Firmware Update................................................................................................................................ 16
7Shipping, Maintenance and Disposal................................................................................................. 17
8Troubleshooting ................................................................................................................................. 18
9Ordering Information ......................................................................................................................... 19
9.1 FL3X Switch 1000BASE-T1.................................................................................................................19
9.2 Accessory Parts .................................................................................................................................19
9.3 Related Documents............................................................................................................................19
10 Appendix............................................................................................................................................. 20
10.1 Appendix A: Guideline for handling ESD sensitive Products.................................................................20
10.2 Appendix B: .......................................................................................................................................20
10.2.1 Acronyms and Abbreviations ..............................................................................................................20
10.2.2 List of Tables .....................................................................................................................................20
10.2.3 List of Figures ....................................................................................................................................20

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 6 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
1General
1.1 Intended User Group
This document is written for expert technicians and/or engineers who are familiar with electronic
components and systems.
Each person involved with setup or operation of the product must
be a qualified technician or engineer
strictly adhere to this manual
receive a briefing by an authorized person
NOTICE
If you are unsure of how to use the product as intended or have any questions about the
use of the product, please discontinue use of the product immediately and contact the
STAR ELECTRONICS GmbH & Co. KG Support.
WARNING
The product may only be used by expert technicians and/or engineers who are qualified
and familiar with electronic components and systems!
The use of the product by non-professionals is not permitted and strictly forbidden!
1.2 Intended Use
The FL3X Switch1000BASE-T1 is a testing equipment. It was developed to test the communication behavior
of automotive bus systems and Ethernet together with Electronics Control Units and sensors in a fully
controlled testing and/or laboratory environment.
For this intended use, the FL3X Switch1000BASE-T1 offers the following options:
-Transmit and receive data (e.g. Use Case “Switch”).
-Exchange of data traffic between two or more bus systems (e.g. Use Case “Switch between 100 and
1000BASE-T1”)
Any deviation from the intended use and/or installation in a testing vehicle is only permitted with specific
prior written approval of STAR ELECTRONICS GmbH & Co. KG.
WARNING
The FL3X Switch1000BASE-T1 may be used to communicate with networked electronic
systems. E.g. Ethernet.
Any use of the product outside a fully controlled testing and/or laboratory environment
may result in death or serious injury due to unpredictable behavior of a vehicle and/or
potentially missing, deactivated, or malfunctioning safety devices on a vehicle!
The user is responsible to ensure the safety of the entire system. This includes amongst
other things a safety shutdown.

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 7 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
NOTICE
The device is not a calibrated measurement device. STAR ELECTRONICS GmbH & Co. KG
accepts no liability whatsoever for the correctness of any measurement results.
WARNING
The FL3X Switch1000BASE-T1 is NOT designed, intended, or authorized and may NOT be
used for or in connection with the following purposes and/or devices:
- use as part of medical systems
- life support applications
- aviation, space, nuclear, or military applications
- use in areas where combustible or explosive gas mixtures are likely to occur
- any other purposes/devices deviating from the intended use of the product
specified by STAR ELECTRONICS GmbH & Co. KG.
WARNING
The product may only be used by expert technicians and/or engineers who are qualified
and familiar with electronic components and systems!
The use of the product by non-professionals is not permitted and strictly forbidden!
1.3 Used Pictograms
The meaning of used pictograms is shortly described below.
Follow the specific instructions in the document where these pictograms are placed.
WARNING
Used to indicate a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
NOTICE
Used to indicate a situation which may result in an operating failure.
Damage of the product may occur, but there is no hazard of injury
if not avoided.
Product marking which shows the compliance of the product with the European Waste
Electrical and Electronic Equipment Directive 2012/19/EU.
1.4 Safety and Handling Instructions
Please read the instructions for use carefully. To protect the device or the application against damage, or
to avoid personal injury the FL3X Switch1000BASE-T1 have to be handled as described herein.
Changes or modifications of the FL3X Switch1000BASE-T1 are not allowed for safety and warranty
reasons!

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 8 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
STAR ELECTRONICS GmbH & Co. KG is not liable for any damages arising from non-observance of the
product information.
Follow the
a) specific safety and handling instructions placed at dedicated document positions
b) general safety and handling instructions below:
NOTICE
To prevent damage to the FL3X Switch1000BASE-T1, or consequential damages:
Do not connect any other signals to the interfaces as described in the chapter 3.4
Interfaces. Ensure that all signals are within the specified range.
Use only adapter cables from STAR ELECTRONICS GmbH & Co. KG for connecting the
FL3X Switch1000BASE-T1.
High temperatures can damage the FL3X Switch1000BASE-T1. Keep the FL3X
Switch1000BASE-T1 away from heaters, stoves, fireplaces, and other sources of heat.
Do not expose the FL3X Switch1000BASE-T1 to rain or use it near water.
Do not use the FL3X Switch1000BASE-T1 in areas of explosion hazard.
1.5 Meaning of Text Styles
In this document filenames are marked with a different text format.

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 9 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
2Product Description
2.1 FL3X Switch 1000BASE-T1 at a glance
The FL3X Switch 1000BASE-T1 is a Ethernet switch with 7 x 100/1000BASE-T1 ports and 2 x SFP(+)
1000/10GBASE-T port. With the FL3X Switch 1000BASE-T1, it is possible to connect an automotive
Ethernet network to a standard PC for testing or diagnostic purposes. It supports up to 1000 MBit/s in full
duplex mode on both sides.
•Marvell 88Q6113 switch chip
•7x Marvell 88Q2112-A2 transceiver
•7x SPE connector for 1000BASE-T1 (Harting Tw1ster, IEC 63171-6)
o100 MBit/s and 1000 MBit/s mode
•2x SFP(+) connector for 1000/10GBASE-T (RMU Port)
•Supply voltage: 8 – 48 V DC
•Status LEDs
•IP20
•Temperature range -40°C to +85°C
2.2 Accessory Parts
For further information about accessories for the FL3X Switch 1000BASE-T1 see chapter 7.2 Accessory
Parts.
NOTICE
Use only accessory parts from STAR ELECTRONICS GmbH & Co. KG listed in chapter
7.2 Accessory Parts to ensure proper function and for warranty reasons!
Other accessories without prior written consent of STAR ELECTRONICS GmbH & Co. KG
must not be used.

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 10 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
3First steps
The FL3X Switch 1000BASE-T1 comes with a default configuration. Ports 1-7 configured as 1000BASE-T1 in Slave
mode, Port 9 as 1000BASE-Tx and Port 10 as 10GBASE-T uplink.
Port 9 is configured as default configuration port.
Our FL3X Switch 1000BASE-T1 uses “Automotive Switch Configuration Tool” by Marvell to get configured. The
Switch is designed as layer 2 switch on MAC layer, so it does not own an IP address. Therefore, it does not use a
webpage for configuration.
The Switch can be recognized by the tool automatically if connected to the computer.
For using “Automotive Switch Configuration Tool” an NDA with Marvell is necessary.
Do you already have an NDA with Marvell in place as mentioned in our quotation for doing the configuration?
- If yes, you can configure the switch by using their configuration tool.
- If no, then please send us contact data of a person that would sign a 3-party-NDA with Marvell and STAR.
For your access to Marvell Extranet please register at:
https://www.marvell.com/support/extranets.html
Then contact Marvell Support and ask for access to 88Q11x and 88Q6113.
https://www.marvell.com/portal/registration.html
Please keep in mind that NDA process might take a few days.
Afterwards download the “Automotive Switch Configuration Tool” from the Extranet and start with the configuration.
If the tool is still not visible, please contact our support team:
Support-ee@star-cooperation.com
In case of further questions, feel free to contact our support (support-ee@star-cooperation.com) for details.

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 11 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
4Technical Data
4.1 Electrical Characteristics
Supply voltage
Min. Typ. Max.
Operating +8.0 V - +48.0 V
Absolute maximum
(non-operating)
-60.0 V - +60.0 V
Latency between
1000BASE-T1 and 10GBASE-T
1000BASE-T1 and 1000BASE-T1
Up to 10 µs
Up to 10 µs
Supply current - operating typical 670 mA without SFP(+) modules
SFP Module with 1G -> + 100 mA @ 12 V
SFP+ Module with 10G -> + 150 mA @ 12 V
Table 1: Electrical characteristics
4.2 Physical Characteristics
Connectors
-
Power Binder Series 711 2 Pin
-Ethernet (BASE-T)
SFP(+) (Con 9 and Con 10)
-Ethernet (BASE-T1)
SPE (Con 1 to Con 7) (T1 IEC 63171-6)
Weight approx. 625 g
Dimensions approx. L x W x H 166mm * 124mm * 36mm
Table 2: Physical characteristics
4.3 Environmental Conditions
Temperature
Operating: -40°C – +85°C
Non-operating: -40°C – +85°C
Storage: -40°C – +85°C
Relative Humidity 0% – 90% r. H., non-condensing
Table 3: Environmental conditions
4.4 Interfaces
The FL3X Switch 1000BASE-T1 has a Binder series 711 power connector, two SFP(+) connectors for the
1000/10GBASE-T (Ethernet), see the following figure.
Figure 1: Side with Power and two SFP(+) Ethernet (10G/1000BASE-T)
The other side has seven SPE T1 connectors for 100/1000BASE-T1 ethernet and two LED’s for each
connector. The following figure shows the position of the seven connectors.
Con 9
Con 10

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 12 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
Figure 2: Side with 1000BASE-T1
4.4.1 Power connector (Binder) and LED
The valid range of the power supply for the FL3X Switch 1000BASE-T1 is within 8 - 48 V DC. The power
supply input of the FL3X Switch 1000BASE-T1 is reverse protected.
The green LED near the power cable shows the power supply status, if the LED is on, the power is OK.
Figure 3: Power connector Binder 2pol with LED
Power LED
Description
On
The device is powered on
Table 4: Description of the Power LED
The following table describes the connector assignment.
Power connector
Pin
Signal Name
Description
1
GND
Ground signal
2
Uin
Power in allowed in the range from 8 – 48 V
Table 5: Description of the Power connector
LED
Con 1
Con 7

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 13 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
4.4.2 Ethernet Con 1 – 7 (SPE T1 IEC 63171-6) and LEDs
NOTICE
Only the revision 1 of Harting T1 SPE connectors are compatible to the
FL3X Switch 1000BASE-T1 (3-0103-0A01-01)
NOTICE
Only the revision 2 of Harting T1 SPE connectors are compatible to the
FL3X Switch 1000BASE-T1 Rev.2 (3-0103-0B02-01)
The FL3X Switch 1000BASE-T1 supports seven 1000BASE-T1 SPE connectors marked Con 1 to Con 7.
These connectors support 100/1000MBit/s in full-duplex mode. The 1000BASE-T1 connectors supports
both A0 (legacy) and A2 (IEEE-compliant) mode.
Figure 4: 1000BASE-T1 SPE connector side with LEDs
NOTICE
The maximum allowed length of the 1000BASE-T1 cable is 30m.
Figure 5: SPE-T1 Ethernet connectors Con 1 to Con 7 with yellow and green LED
The following table describes the LED color and blinking scheme.
Activity
Link

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 14 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
1000BASE-T1 SPE LEDs
Green LED
(Link)
Yellow LED
(Active)
Description
On
Off
The link is established, no data exchange occurring
On
Blinking
Data exchange is in progress
Off
Off
No link is established, the data exchange is not possible
Table 6: Description of the 1000BASE-T1 SPE LEDs
The following table shows the SPE connector assignment.
Connector SPE (1000BASE-T1 2-wire ethernet)
Pin
Signal Name
Description
1
ETH_BP
1000BASE-T1 bus plus signal
2
ETH_BM
1000BASE-T1 bus minus signal
Table 7: Connector assignment for SPE (2-wire ethernet)
4.4.3 Ethernet Con 9 and 10 (SFP+ module)
The FL3X Switch 1000BASE-T1 supports a 1000BASE-Tx interface at the SFP+ connector Con 9. These
connector supports 1 GBit/s in full-duplex mode. Also, a 10GBASE-Tx interface at the SFP+ connector Con
10. These connector supports 10 GBit/s in full-duplex mode.
NOTICE
The maximum allowed length of the Ethernet cable is 30m.
NOTICE
Con 9 is configured during hardware to 1Gbit/s and Con 10 to 10GBit/s. This can be
changed with software configuration.
The standard SFP(+) connector assignment is used.
4.4.4 RMU Port (Remote Management Unit)
The FL3X Switch 1000BASE-T1 can be configured with the RMU. The port which is selected during
hardware is port 9. The software running on 88Q6113 in the FL3X Switch 1000BASE-T1 allows
configuration over all ports which are not down.

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 15 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
5Getting Started
5.1 Assembly and Line-up
Read and follow these instructions when connecting and using the FL3X Switch 1000BASE-T1:
NOTICE
Ensure that all signal lines connected to the FL3X Switch 1000BASE-T1 are in the
allowed range.
Be sure to connect all cables as described in this manual.
Never insert anything metallic into the openings of the FL3X Switch 1000BASE-T1.
Ensure to grasp the plug and not the cable when disconnecting the FL3X Switch
1000BASE-T1.
5.2 Configuration and Operation
Use the power connector of the FL3X Switch 1000BASE-T1 to connect with a power-supply within the
correct voltage range.
Connect the 1000BASE-T1 and Ethernet (1000BASE-T) with their networks. Check the pinouts.
Check the state of the LEDs.
For change settings from the FL3X Switch 1000BASE-T1 use the configuration software from Marvell.

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 16 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
6Firmware Update
To update or upgrade the firmware of FL3X Switch 1000BASE-T1 it is important to have a stable network
connection between the used PC and FL3X Switch.
Connect the FL3X Switch with RMU port (default port 9) to the PC and check communication via
AutomotiveSwitchConfigurationTool. Read out the MAC address and target ID of the used FL3X Switch and note
it.
Afterwards start the delivered batch file “start_fwdownload.bat” and follow the instructions. The local ETH
adapter of your PC, MAC address and target id of the FL3X Switch has to be chosen.
If there is no error, the batch file will close automatically.
For flashing binary config files an additional tool, our FL3X Switch Configurator is available. Please ask our
support team for more information.

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 17 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
7Shipping, Maintenance and Disposal
Dispose off properly per regulations of the country where end-of-life occurs.

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 18 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
8Troubleshooting
This chapter contains some frequently asked questions about the FL3X Switch 1000BASE-T1.
1
Effect
Solution
2
Effect
Solution

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 19 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
9Ordering Information
9.1 FL3X Switch 1000BASE-T1
Product
Description
Ordering number
FL3X Switch 1000BASE-T1
Rev.2
Ethernet Switch to connect
100/1000BASE-T1 and 1G/10GBASE-Tx 3-V1030A02
9.2 Accessory Parts
Product
Description
Ordering number
Power cable binder to banana
2.0 m
2.0 m Binder male 2pol to banana male
connector power cable
3-00341D02
1G SFP module with RJ45
connector
1GBASE-T IEEE 802.3-2002 SFP module
with RJ45 female connector
10020431
10G SFP+ module with RJ45
connector
10GBASE-T IEEE 802.3-2008 SFP+ module
with RJ45 female connector (0 – +70°C!)
10020420
10G SFP+ fibre module 10GBASE-T IEEE 802.3-2012 SFP+ fiber
module with 850nm
10020432
SPE bus cable (2m)
2 pole SPE male to 2 pole SPE male, 2m
10020364
SPE bus cable (5m)
2 pole SPE male to 2 pole SPE male, 5m
10020363
Bus cable SPE to Sub-D 2.5 m
2.5 m SPE to Sub-D male 9pol bus cable
3-00343G01
Customer specific parts
Please contact
STAR ELECTRONICS
GmbH & Co. KG
Customer specific switch configuration
Please contact
STAR ELECTRONICS
GmbH & Co. KG
9.3 Related Documents
Document
Description
document number
-

Created by STAR ELECTRONICS GmbH & Co. KG
Date created 2023-07-26 Date modified 2023-12-04 Page 20 of 22
3-0103-0a01-d11_instruction_for_use_fl3x_switch_1000base-t1_d1v6-f.docx
10 Appendix
10.1 Appendix A: Guideline for handling ESD sensitive Products
Any tester, equipment, or tool used at any production step or for any manipulation of semi-
conductor devices must have its shield connected to ground.
The product itself and the carrier system of the product respectively must be placed on a
conductive table top or covered by an antistatic surface (superficial resistivity equal to or higher
than 0.5MΩ/cm2), grounded through a ground cable (conductive cable from protected equipment to
ground isolated through a 1MΩ resistor placed in series).
All manipulation of finished goods has to be made at such a grounded worktable.
The worktable must be free of all non-antistatic objects.
An antistatic floor covering grounded through a conductive ground cable (with serial resistor
between 0.9MΩand 1.5MΩ) should be used.
It is recommended that you wear an antistatic wrist or ankle strap, connected to the antistatic floor
covering or to the grounded equipment.
If no antistatic wrist or ankle strap is worn, touch the surface of the grounded worktable before
each manipulation of the ESD sensitive product.
It is recommended that antistatic gloves or finger coats be worn.
It is recommended that nylon clothing be avoided while performing any manipulation of parts.
10.2 Appendix B:
10.2.1 Acronyms and Abbreviations
Item
Definition
BD Bus driver
BP Bus plus
BM Bus minus
ECU Electronic Control Unit
EMC Electromagnetic Compatibility
ESD
Electro Static Discharge
NC
Not Connected
PCB Printed Circuit Board
PL Physical Layer
SFP Small form-factor pluggable transceiver (1 Gbit)
SFP+ Small form-factor pluggable transceiver (10 Gbit)
10.2.2 List of Tables
Table 1: Electrical characteristics .......................................................................................................................11
Table 2: Physical characteristics.........................................................................................................................11
Table 3: Environmental conditions ......................................................................................................................11
Table 4: Description of the Power LED ................................................................................................................12
Table 5: Description of the Power connector.......................................................................................................12
Table 6: Description of the 1000BASE-T1 SPE LEDs ............................................................................................14
Table 7: Connector assignment for SPE (2-wire ethernet)....................................................................................14
10.2.3 List of Figures
Figure 1: Side with Power and two SFP(+) Ethernet (10G/1000BASE-T) ..............................................................11
Figure 2: Side with 1000BASE-T1........................................................................................................................12
Table of contents
Popular Switch manuals by other brands

3One data
3One data IES6100PN-8T-2LV Quick installation guide

View Tech
View Tech 4-port PoE Switch with 1 Uplink Port user manual

Data Video
Data Video HS-1600T instruction manual

Guard master
Guard master PROSAFE RKSE Series manual

digi-tech
digi-tech AC-1762 user manual

Wyrestorm
Wyrestorm MXV-0404-H2A-KIT quick start guide