STARLINK MN2525 Guide

Fast and Reliable Home Network with MoCA 2.5
MoCA 2.5 adapters boost the data speed and performance to reach up to 2.5 Gbps to build
MN2525 single full-duplex Gigabit Ethernet port to reach 2.0 Gbps line rate.
MN2550 dual full-duplex Gigabit Ethernet ports to reach 2.5 Gbps line rate.
drop.
MN2525 / MN2550 MoCA 2.5 Adapter
2

Overview
The MN2525/MN2550 MoCA 2.5 adapter is a high-speed network adapter for extending home
anywhere a coaxial outlet is available. The output of the adapter also includes a TV or set-top box
Package Content
•MN2525 or MN2550 MoCA 2.5 Adapter
•Coaxial cable (RG6)
•Ethernet cable (CAT5e)
•AC/DC power adapter
•Start Guide
•Available coaxial port
•Available electrical power socket
Peripheral Interface
MN2525
•ETHERNET (1000Base-T) port
•COM (Coax In/Out) coax port
•CATV (TV/STB In/Out) coax port
LED
•POWER
glows green when Adapter is powered up
•ETHERNET
•COAX
glows green when Coax (MoCA) links up
MN2525 / MN2550 2.5 Adapter
3
MN2550
•LAN1 and LAN2 (1000Base-T) ports
•MoCA (Coax In/Out) coax port
•TV (TV/STB In/Out) coax port
LED
•Power
glows green when Adapter is powered up
•LAN1 and LAN2 (on port)
•MoCA
glows green when MoCA links up
•System
glows green when the Adapter is online
MN2550
MN2525

It’s a simple plug-and-play process to connect the Adapters. First, connect one Adapter to the
TV or set-top box, the broadband modem or router, and the Internet signal is established over the
Internet signal from the modem/router and delivers it to the coaxial network, while keeping the
TV or set-top box connected.
locate the coaxial outlet nears the home modem or router provided by Internet Service Provider.
Unplug the end of the coaxial cable connected to the TV set or set-top box from its coaxial wall
outlet. If no TV set or set-top box is plugged into this coaxial outlet, skip to step 3.
CATV
(MN2525) or TV (MN2550) on the side of the Adapter.
COM (MN2525) or MoCA
(MN2550) on the side of the Adapter.
in step 1.
ETHERNET (MN2525) or LAN1 (MN2550) port on
the side of the Adapter.
Web browsing is needed. Or connect the other end of the Ethernet cable into the Ethernet port
of the device to connect to Internet.
other end of the power adapter into an electrical outlet or power source.
MN2525 / MN2550 MoCA 2.5 Adapter
4
MN2525 MN2550

MN2525 Make sure the POWER, ETHERNET and COAX
MN2550 Make sure the Power, MoCA and System LAN1 / LAN2 Ethernet
MN2525 / MN2550 MoCA 2.5 Adapter
5

cable connected to the TV set or set-top box from its coaxial wall outlet. If no TV set or set-top
box is plugged into this coaxial outlet, skip to step 3.
CATV
(MN2525) or TV (MN2550) on the side of the Adapter.
COM (MN2525) or
MoCA (MN2550) on the side of the Adapter.
in step 1.
ETHERNET (MN2525) or LAN1 (MN2550) port
on the side of the Adapter. .
other end of the power adapter into an electrical outlet or power source.
MN2525 / MN2550 MoCA 2.5 Adapter
6
MN2525 Make sure the POWER, ETHERNET and COAX
MN2550 Make sure the Power, MoCA and System LAN1 / LAN2 Ethernet

Adapter Web Management
ETHERNET (MN2525) or LAN1 / LAN2 (MN2550) port of the Adapter and the
Ethernet port of a computer with an Ethernet cable. Power on the Adapter.
to login with
user name: admin, password: maxlinear
changed and reviewed.
RESET
Adapter for more than 10 seconds and release it.
command.
MN2525 / MN2550 MoCA 2.5 Adapter
7
MN2525
RESET
MN2550
RESET

MN2525 / MN2550 MoCA 2.5 Adapter
MoCA, Ethernet / IP and RF
Chipset
Operang Freuency
Transmit Return Loss
Output Power
Input Power
Modulaon
MN2525 2.0 Gbps
MN2550 2.5 Gbps
MN2525 Full-Duplex 1 Gbps
MN2550 2 x Full-Duplex 1 Gbps
Applicaon Protocol
Management
Ethernet
MN2525 1000 Base-T MDI/MDIX, 2 x 75F
MN2550 2 x 1000 Base-T MDI/MDIX, 2 x 75F
Freuency Range
Transmit Return Loss
Inseron Loss
Band Flatness
5 MHz to 1002 MHz
14 dB Relave to 75
-2.5 dB
2 dB
OFDM 1024 QAM, TDD
VANs, 02.11p, IGMP v1/2/3, 12-bit AES Encrypon
Web Based Conguraon via 1000Base-T Connecon
IEEE02.3, IEEE02.3az
MoCA 2.5
Ethernet
Radio Freuency / TV
PHY Data Rate
MAC Data Rate
Maxlinear MX3710; 32 Mbit SPI Flash
Interface
1125 MHz to 1675 MHz Congurable Extended D Band
6 dB Relave to 75
+7 dBm; 5 x 100 MHz Channels
-50 dBm to +1 dBm

Power Supply and Hardware
Environment and Safety
MN2525 / MN2550 MoCA 2.5 Adapter
Temperature
Operang/Storage Humidity
FCC Cercate
RoHS
MTBF
AFR in Connuous Operaon
< 1.5%
Non-Condensing; Altude < 2000 m
Operaon 10% to 5%; Storage 5% to 0%
CISPR PUB. 22, FCC Part 15 Subpart B
RoHS 2.0 Standard 2011/65/EU, Amendment 2015/63/EU
> 300,000 hours Telcordia SR-332
Operang 22°F to 113°F (-5°C to 45°C); Storage -4°F to 15°F (-20°C to 5°C)
Environment and Safety
Power Supply
Power Consumpon
Dimension W x D X H
Weight
MN2525 POWER (green), ETHERNET (green), COAX (green)
MN2550
Power (green), System (green), MoCA (green)
AN1/AN2 ink (green), Acvity (amber)
MN2525 DC Input, 1000Base-T RJ 45, COM (MoCA) 75F, CATV 75F, RESET
MN2550 DC Input, 2 x 1000Base-T RJ 45, MoCA 75F, TV 75F, RESET
Power Supply
100 - 240 VAC, 50/60 Hz; 12 VDC, max. 0.5 A, 1.3 mm PSU Wall Plug
< 3 was
4.3" x 2." x 1.1" (110 mm x 70 mm x 2mm)
3.2 oz (0 g)
Hardware
LED
Connectors

Notes Warranty
from State to State in the United States, from province to province in Canada, and from country to country
may not apply to the customer.
• Do not use this product near water–for example, near a bathtub, kitchen sink, laundry tub, or swimming pool, or
in a wet basement; only clean with dry cloth.
produce heat.
• Do not use the telephone to report a gas leak in the vicinity of the leak.
• Use only the power cord indicated in this manual if applicable.
Coaxial Cable
If applicable, the coaxial cable screen shield needs to be connected to the Earth at the building entrance per
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
Reorient or relocate the device;
to power line products)
• Consult the dealer or an experience radio or television technician for help
• This device may not cause harmful interference
the device
CE
MN2525 / MN2550 MoCA 2.5 Adapter
10

MN2525 / MN2550 MoCA 2.5 Adapter
Prpblem: No coax network has been established.
• Place two Adapters close to each other and connect them with a short coax cable to see if the Adapters connect
• Check if a Cable TV or over-the-air TV signal is available on both cable wall outlets
the Adapter
Problem:
cables to the cable modem or set-top box and another coax to the Adapter.
Make sure that your broadband router is also connected to a MoCA adapter and that the Ethernet port on that
I have AT&T/DirecTV or DISH network
My Internet speed is too slow
The COAX/MoCA LED is not lit
and
My Internet speed is too slow
My Adapter doesn’t work with other MoCA adapters
(MoCA 1.0/1.1/2.0) published. Older version of MoCA adapters may have been out-of-date, worn out or
MoCA adapters with the new ones to reach the best performance expected.
11
Other manuals for MN2525
1
This manual suits for next models
1
Table of contents
Other STARLINK Adapter manuals