Rear View - MS18-DC2403-8CM1
24V DC 3A 84W 8 Channel at 250mA Max. Each
Rear View - MS18-DC481A5-8CM1
48V DC 1.5A 84W 8 Channel at 125mA Max. Each
All Units Were Tested Under LVD IEC/EN 60950-1, PSE J60950, EMC EMI
EN55022 (EN61000-3-2,3) & EMS EN55024 (EN61000-4-2,3,4,5,6,8,11) Standards
Front View - MS18-DC1206-8CM1
12V DC 6A 84W 8 Channel at 500mA Max. Each
Installation :
Do place the power cable properly so it will not be steeped in or tripped over.
Do not place the AC power supply in a location where it is:
Subject to extreme high or low ambient temperature
l
Subject to direct sunlight or near a heat source such as oven, stove etc.l
Subject to mechanical vibration or shockl
Subject to excessive amount of dustl
STEED MAGNET PRODUCTS ENTERPRISE CO., LTD. warrant this product to be free from defects
in material and workmanship for a period of 90 days from the date of purchase from our authorized
dealers. Should the product require service during this period, all labor and parts used to effect repairs
will be supplied free of charge. reserve the right to determine whether damage has beenSTEED
occasioned by accident, misuse, or improper installation whereby the warranty would be void.
In the event of a defect occurring during warranty period, the original purchaser may return the defect
unit along with suitable proof of purchase date and a full(i.e. receipt, docket, credit card slip etc.)
description of the defect to the dealer you purchased. All freight charges incurred for transportation by
the dealer or are the purchaser's responsibility.STEED
WARRANTY
lCopyright - All Information Reserved !
MS-DC (Desktop Type)Series
lCopyright - All Information Reserved !
Multiple Output Security CCTV Power Supply
Instruction Manual
The Power Master
R
Notes: All rights reserved. Do not reprint without written permission.l
Steed reserves the right to modify products without notice.l
File No. MNL-MS-DC-Prime
Issue No. Revision Ori 0814
P&IRECAUTION MPORTANT NOTICE
!
Moisture :
If the device is moved from a cold place to a warm room, condensation may occur
l
inside. To avoid damage please allow the device to reach room temperature before
using it.
On safety :
Before operating the system, carefully check the specifications of your appliance. Be
l
sure that the operating voltage of your appliance is identical with your local mains.
The power supply is for indoor use only! Keep it in dry environment.
l
Do not use the power supply if there are signs of any damage in housing, plug or cord.l
The unit is not disconnected from the AC power source (mains) as long as it isl
connected to the wall outlet, even if the unit itself has been shutdown.
Unplug the system from the wall outlet if it is not to be used for an extended period of
l
time. To disconnect the cord by grasping the plug. Never pull the cord itself.
Should any liquid or solid object fall into the system, unplug the system’s power cord
l
and have the system checked by qualified personnel before operating it any further.
Do not open the device or make unauthorized modifications to the circuit inside.
l
Repair works must only be carried out by qualified servicing personnel.l
:Operation
Make sure the current and voltage of the equipment matches that of the outlet.l
For safety, if the output current is too high, the unit will automatically shut down.l
To prevent damage, not to drop or it may cause a mechanical shock to the unit.l
After using, disconnect the unit from the wall outlet and the equipment.l
Disconnect the unit from the AC outlet by pulling on the plug. Do not pull on the cord.l
To avoid short-circuiting, do not allow the output screw terminals of the unit or inputl
connector plug to touch any metal object.
To ensure proper operation, read this manual thoroughly before using this product.
After reading, be sure to keep it where it can be seen by all those who use the product.
Cleaning :
Do remove any power sources from the unit before attempting any cleaning or
l
maintenance checking for preventing from being electrical shocked.
Clean the unit with a soft, dry cloth. If the unit is very dirty, wipe it off with a soft cloth
l
lightly moistened with a mild detergent solution, and then wipe with a soft dry cloth.
If you use any chemical cleaner, observe the instructions provided with the product.
l
If the cabinet of the unit is splashed with any type of solvent such as insecticide, orl
remains in contact for a long time with cable rubber or vinyl, the finish of the cabinet
may be damaged.
Rear View
Model MS -DC1206-8CM1
18
Front View
Model MS -DC1206-8CM1
18
S
E
12345
678
Indicator of Slave Outputs of Regulated 12V at 500mA Max. Each Channel
LED STATUS INDICATION
GREEN = Output Is In Powering Loads Normally
YELLOW = Power On and In Standby Normally
OFF = Power Off or Mains Thermal Shutdown
12345678
Indicator of Slave Outputs of Regulated 24V at 250mA Max. Each Channel
LED STATUS INDICATION
GREEN = Output Is In Powering Loads Normally
YELLOW = Power On and In Standby Normally
OFF = Power Off or Mains Thermal Shutdown
Model:MS DC2403-8CM1
-
18
Multiple Outputs
Security CCTV Power Supply
The Security Power Master
CB LVD & EMC APPROVED
R
12345678
Indicator of Slave Outputs of Regulated 48V at 125mA Max. Each Channel
LED STATUS INDICATION
GREEN = Output Is In Powering Loads Normally
YELLOW = Power On and In Standby Normally
OFF = Power Off or Mains Thermal Shutdown
Model:MS DC481A5-8CM1
-
18
Multiple Outputs
Security CCTV Power Supply
The Security Power Master
CB LVD & EMC APPROVED
R
Available From:
Prime-co Pte Ltd.
7030 Ang Mo Kio Ave 5 #03-27 Northstar
@ AMK, Singapore 569880
llTel: Fax:65-6252-1221 65-6252-4700
Email: [email protected]
www.prime-co.com.sgWeb-site:
Manufactured By:
Steed Magnet Products Ent Co Ltd.., .
in Taiwan, R.O.C.
For Distributing By:
Prime-co Pte Ltd.
in Singapore
Front View - MS18-DC2403-8CM1 Front View - MS18-DC481A5-8CM1
O
I
FUSE
48V 125mA Max. Each Channel
87654321
REGULATED SLAVE OUTPUTS
RED
BLK
AC INPUT
100V - 240V~
1-0.5A 50/60Hz
l
Replace only
w/2.50A 250V
5x20mm type
Fast blow fuse
AC POWER
OFF
ON
l
Label#LB-481A5-8-AF
WARNING
High Voltage !
MASTER OUTPUT
Output Voltage:55.2Vl
lOutput Current:1.5Amps
(Total, Including The
8 Channel of Slave Outputs)
l
Build in 3.0A 58V Fuse
Replace only with same
l
Rating & Blade Auto Fuse
DC FUSE
CAUTION
l
Polarity Are Critical !
lDon’t Overload Any Outputs
Made in Taiwan Label #LB-481A5-8-M
l
RED
BLK
AC INPUT
AC FUSE
F
U
S
E
PUSH
O
I
FUSE
24V 250mA Max. Each Channel
87654321
REGULATED SLAVE OUTPUTS
RED
BLK
AC INPUT
100V - 240V~
1-0.5A 50/60Hz
l
Replace only
w/2.50A 250V
5x20mm type
Fast blow fuse
AC POWER
OFF
ON
l
Label#LB-2403-8-AF
WARNING
High Voltage !
MASTER OUTPUT
Output Voltage:27.6V
l
l
Output Current: 3Amps
(Total, Including The
8 Channel of Slave Outputs)
l
Build in 5.0A 32V Fuse
Replace only with same
l
Rating & Blade Auto Fuse
DC FUSE
CAUTION
l
Polarity Are Critical !
l
Don’t Overload Any Outputs
Madein Taiwan Label#LB-2403-8-M
l
RED
BLK
AC INPUT
AC FUSE
F
U
S
E
PUSH

lCopyright - All Information Reserved !
l
Copyright - All Information Reserved !
Multiple Output Security CCTV DC Power Supply
R
USE
The series are specifically designed for converting the AC mains into low DC VoltageSTEED MS-DC
with multiple outputs for powering Security Surveillance Cameras and any other security devices.
( - This series units are NOT waterproofed. So, to be used indoor only!)Note
FEATURES
lWorld-Wide all models, TOP Quality in every respects !!CB, LVD, EMC & PSE Approved
lUpdate Green Current Switching Mode Technology provides of:
- Accepts wide of universal input voltage from 100V to 240V AC 50/60Hz
- Very low standby power consumption(No Load) saving you( considerable power-bills !)
- Very high power factor (PF) and efficiency provides again, much lower power consumption in
of powering CCTV and all security equipments , as it to be kept on line forever,Loading forever
once it is installed ! (so, much of power-bills for NOT burning your pocket !)saving you forever
- Very light in unit’s weight ( considerable charges in freights of collecting it !)saving you
lVery low ripple noise enhancing your system for a clear video with minimizing snowing noises !
lBuilt-in with Varistor for minimizing risks of lightning strike !
lBuilt-in with NTC thermistor for limiting the input inrush current !
lBuilt-in with heat sensitive thermistors for detecting and protecting from being overheated !
lIndividual PTC protection against output overload or short circuits affecting each other !without
lIndividual monitoring output status with varied color LED indicator each channel !
lNormal operation will be resumed automatically once abnormality are removed respectively each !
lBuilt with Steed innovative design of wire, tool connectors, for much inBare Free Fasten savings
time & wages of installations & services and the parts costs of mounting screws andconsiderable
terminal lugs etc. that complicated traditional connectors are required as market units used !
lSteed usually high quality and compact design with very good workmanship in all respects !
MS-DC Series (Desktop Type Version)
Front Panel
(For Model MS -DC1206- )18 8CM1
Rear Panel
(For Model MS -DC1206 )18 -8CM1
!
WARNING To avoid risks of electric shock, always disconnect the power supply before replacing
fuse. All devices connected to the supply will be then turned off when the supply is disconnected.
1. Disconnect the power supply.
2. Locate the fuse that must be replaced on the rear panel of the power supply.
3. Using a flathead screw driver to remove the cap of the fuse holder.
4. Remove the damaged fuse, and replace with a same type and rating fuse as marked.
5. Reassembly the cap of the fuse holder and ensure that it is closed in place correctly.
6. Reconnect the power supply.
MAINTAINING ND USE EPLACINGAF R
FPARPCRONT ANEL ND EAR ANEL ONFIGURATIONS
Table 2) C SOMMON PECIFICATIONS
Common Specifications 12V Models
Cold Star <7.5A/100Vac / <15A/240Vac
84W
24V Models 48V Models
DC Fuse Rating
Input In-Rush Current
Overload Protection
Efficiency (Typ.)
Ripple & Noise (Max.)
Total Output Power
Working Temperature
Power Factor (Typ.)
AC Fuse Rating Glass
Fast Blow Type 5x20mm
Auto Mini Blade Type
7.5A / 32V
Brown Color
5A / 32V
Orange Color 3A / 58V
Violet Color
2.5A / 250V
Constant Current limiting, Short Circuit Shutdown, Auto Recovery
PF > 0.99 / 100Vac, PF > 0.95 / 240Vac
> 86% at Max. Load
100mVp-p
< 1% from 10% to maximum Load
STEED AC Plug Type Code
Load Regulation
32 F to 104 F (0 C to 40 C)
oooo
A=Japan/Taiwan, E=Europe Schuko, F=N. America, G=Aust./N.Z., H=U.K. British, K=Italy
1
2
3
44
7
5 6
F
U
S
E
PUSH
O
I
FUSE
12V 500mA Max. Each Channel
87654321
REGULATED SLAVE OUTPUTS
AC INPUT
100V - 240V~
1-0.5A 50/60Hz
l
Replace only
w/2.50A 250V
5x20mm type
Fast blow fuse
AC FUSE
AC INPUT
AC POWER
OFF
ON
l
Label#LB-1206-8-AF
WARNING
High Voltage !
MASTER OUTPUT
Output Voltage:13.8V
l
l
Output Current: 6Amps
(Total, Including The
8 Channel of Slave Outputs)
l
Build in 7.5A 32V Fuse
Replace only with same
l
Rating & Blade Auto Fuse
DC FUSE
CAUTION
l
Polarity Are Critical !
l
Don’t Overload Any Outputs
Madein Taiwan Label#LB-1206-8-M
l
RED
BLK
It is designed by the update switching mode technology for accepting wide of universal input voltage,
high efficiency for power saving, smaller dimensions and light for freight savings!
12345
678
Indicator of Slave Outputs of Regulated 12V at 500mA Max. Each Channel
CCTV LED STATUS INDICATION
GREEN = Output Is In Powering Loads Normally
YELLOW = Power On and In Standby Normally
OFF = Power Off or Mains Thermal Shutdown
6Master DC Output Binding Post for Long Distance & High Current Devices:
It provide 13.8Vdc/6A (12V Model); 27.6Vdc/3A (24V Model) and 55.2Vdc/1.5A (48V Model)
of unit’s maximum power for powering the equipments which are in needing a power that the
power supply could supply. Also, for the devices which are located far from this power supply.
1
LED Status Indicator:
lOFF: Power Off or Mains Thermal Shutdown
lYELLOW: Power On and in Standby Normally
lGREEN: Output Is In Powering Loads Normally
44
2
3
AC Fuse: Glass Fast Blow Type 5x 20mm
Cable: Safety Approved Double Insulation Cable VCTF 0.75mm2 x 3C 7A 1.8 m(6ft.)
Master Power On/Off SwitchPower Switch:
5
DC Fuse: Auto Mini Blade Type for protecting the Master output from being short circuits,
overloaded or any abnormal over currents
7
Steed Innovative Design Bare Wire Tool Free Fasten Connectors For Slave Outputs:
1) Push Knob Backward 2) While, Insert 10mm Stripped Wire In 3) Release Knob to Lockgg
4) Push Knob Backward and Pulling Wire Out For Disconnection without the need of a tool !!g
Full Series Covering:
MS -DC1206-
18 8CM1
MS -DC2403-
18 8CM1
ACV
+/-10%
Freq.
(Hz)
Input Rating Channel
Master
Rated
O/P V
(VDC)
M+S
Total
O/P C
(Amp)
Slave
Rated
O/P V
(VDC)
N.W.
per pc
(ref.)
(Kgs)
Slave
Rated
O/P C
(Amp)
100-240V
100-240V
100-240V
50/60
50/60
50/60
13.8V
27.6V
6A 1 8
18
18
3A
12
24
0.5
0.25
WD.
(mm)
220
220
220
HT.
(mm)
Overall Dimension
52
52
52
LG.
(mm)
170
170
0.935
0.935
PCS KGS
Package/Ctn (Ref.)
16
16
20.5
20.5
CBM
0.08
0.08
MS -DC481A5
18 -8CM1
55.2V 1.5A 48 0.125 170 0.935 16 20.5 0.08
STEED
MS-DC
Series
Model No.
l
Contact Steed factory for other voltage models.
l
Specifications are subject to change without notice. Contact dealer or Steed factory for detail on request
Table 1) A S SVAILABLE ERIES and PECIFICATIONS:
M- S-
aster alve
It is passed strict tests, evaluations and inspections and has been gained World-Wide of CB, LVD,
EMC & PSE approvals as a Top quality power supply for using with security etc. equipments where
reliable and high quality power supply are required !
It provided regulated DC power up to total 84W for providing:
8 channel outputs for CCTV cameras at limited smaller currents with full protections against
lslave
overload and or short circuits individually affecting each other, or causedwithout full system
shutdown! It will be return to service automatically once abnormal situations are removed !
1 output for you able to use total of unit’s power for higher power required device as an
lmaster
useful Steed’s innovative design ! (Please refer to table 1 & 2 for detail).
It provided with STEED innovative design of " " wire, tool " ” Connectors, for quickBare Free Fasten
installations & services for time and wage . It also in the partssavings saved you considerable
costs of mounting screws and terminal lugs etc. that complicated traditional connectors required !