Thank you for purchasing this Electric Fence Energiser.
product.
product.
Dimensions: (H x W x D) 187mm x 109mm x 53mm
Weight: 1 KG
Peak Voltage: 10,000 Volts
Average Current: 50mA(0.5J),100mA(1.0J),150mA(2.0J)
Maximum Current: 2A
Pulse Energy: 0.5 Joules/1.0 Joules/2.0 Joules
Output Energy: 0.39 Joules/0.78 Joules/1.56 Joules
Powers up to: 5KM/10 KM/18KM
12V.
This 12V baery-powered Fence Energiser,with a peak voltage of 10,000 volts and pulse
energy of 0.5/1.0/2.0 Joules,is perfect for livestock confinement and paddock maintenance.The
Fence Energiser can be placed off the ground on the Earth Stakes(included),and is also wall-
mountable, meaning strip grazing methods have never been easier!
With a 10km range and low average current of 50mA/100mA/150mA, you can expect a long baery life.
Safety Advice
device.
set-up of this product.
An electric fence should never be supplied by two or more energisers. Only ever use one
energiser per fence.
If there are separate fences, then unless they are supplied from the same circuit of the
energiser, the fences should be separated by a distance of at least 2 metres.
wires and thus would be unable to free themselves. This carries, therefore, the danger of
death.
avoid this.
Ensure that you install cut-out switches where maintenance is to be carried out.
children, pets, etc., are not in the vicinity.
Always ensure the amperage is low.
Warning signs should be prominently displayed on all fences at spacings not exceeding 10 me -
tres. These signs must face outwards from the fence. They should include the symbol here;
Where access may be gained from inside, warnings signs should also be placed on both sides of
the fence.
children in the area is probable, there must be repeat signs placed at 0.8 metres (80cm) also.
If the electric fence is to be installed on, alongside, or adjacent to a public road or pathway, it
the fence posts.
The size of all warning signs must be at least 200mm x 100mm and should be coloured yellow
components.
installing the fence energiser.
1 x Electric Fence Energiser
1 x 1000mm Fence Wire (red)
1 x 1000mm Earth Wire (black)
2 x 200mm Earth Stakes
6 x Small screws to mount Energiser to Earth Stakes (2 spare)
Product Features
2) Earth Stakes connected by 1 x bolt to be placed into the ground.
4) Ultra-bright High Visibility light to check if the fence is live.
5) Black Earth Lead which runs from Earth Terminal to the Earth Stakes.
6) Red Fence Lead which runs from Fence Terminal to the Fence.
7) Earth Terminal
8) Fence Terminal
1
3
2
9
8
7
4
5
6
User Guide
necessarily mean it is weather-resistant. We recommend you install your energiser within a
weatherproof box, out of reach of children, and if possible away from direct sunlight.
An electric fence works via a circuit. The Earth Lead (black) runs from the Earth Stakes to the
runs through the Energiser, through into the fence, and through to the Earth Stakes where it is
grounded (uses the ground to complete a circuit).
all other tasks are complete.
1) Turn over the Energiser. Use 4 x small screws to fasten the upper Earth Stake to the Energiser.
Place the ring end of the Earth Lead (black) on the bolt, between the two Earth Stakes, then
fasten into place using the nut provided.
3) Located at the other end of the Earth Lead (black) is another ring end. On the energiser,
re-fasten the cap.
Installing the Earth-based Grounding System’ and return here.
7) Use 1 x large screw at the top of the energiser and screw into the drilled hole.
poor weather.
Installing the Earth-based Grounding System:
through the fence and back again. If adequate grounding isn’t provided, this will heavily
Using sand, gravel, very dry soil or similar material will not conduct electricity well. Moist soil is
the prime place to plant your grounding system.
Installing the Fence and Fence Lead:
(red) onto the bolt, and replace the Fence Socket cap.
fence.
3) Now ready the fence. It is recommended the fence line is planned thoroughly. Try to avoid
rough, stony, or steep areas if possible.
product.
4) Place the Strain Posts and Corner Posts to the desired areas. Ensure each post is securely
5) Run out the wire. Secure the wire to each post as you do so. Tension the wires so there is
only a slight visible sag.
touch each other when live.
- upright.

Popular Power Supply manuals by other brands

Aervoe Sierra Wave EnerPlex 9700 operating instructions

Aervoe

Aervoe Sierra Wave EnerPlex 9700 operating instructions

Medistrom Pilot-12 plus user manual

Medistrom

Medistrom Pilot-12 plus user manual

Kramer VS-3232DN Installation

Kramer

Kramer VS-3232DN Installation

VOLTCRAFT SPS12-60W operating instructions

VOLTCRAFT

VOLTCRAFT SPS12-60W operating instructions

Akyga AK-ND-45 user manual

Akyga

Akyga AK-ND-45 user manual

StarTech.com ATXPOW500DF Instruction guide

StarTech.com

StarTech.com ATXPOW500DF Instruction guide

Meridian Prime user guide

Meridian

Meridian Prime user guide

Branson DCX A Series Original instructions

Branson

Branson DCX A Series Original instructions

Gewiss Chorus GW19304 installation manual

Gewiss

Gewiss Chorus GW19304 installation manual

Puls DIMENSION UF Series manual

Puls

Puls DIMENSION UF Series manual

Keithley SourceMeter 2470 user manual

Keithley

Keithley SourceMeter 2470 user manual

Akyga AK-L2-100 user manual

Akyga

Akyga AK-L2-100 user manual

Altronix ALTV1224C4 manual

Altronix

Altronix ALTV1224C4 manual

Vahle VKS10 Mounting instructions - Maintenance

Vahle

Vahle VKS10 Mounting instructions - Maintenance

Simpson SIG22PK owner's manual

Simpson

Simpson SIG22PK owner's manual

Heath Heathkit IP-32 Schematic diagram

Heath

Heath Heathkit IP-32 Schematic diagram

EVEBASE MOVE 300 user manual

EVEBASE

EVEBASE MOVE 300 user manual

Fluke 410A user manual

Fluke

Fluke 410A user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.