stellar labs 555-15605 Instruction Manual

www.mcmelectronics.com 1
High PowerLED RGB
Wall Wash Lights
UserHandbook
Model555-15605 24 x 3WLED
555-15610 30 x 3WLED (shown)
3-Watt, Red/Green/BlueLED’s
3/4/6Channel DMXControl
Menu programmingwith4-segmentAlphaNumeric LEDdisplay
UltrabrightEdisonHighPower LED’s

www.mcmelectronics.com 2
GeneralSpecifications:
Model # 555-15605
LEDs 24 x3WRed/Green/Blue/ LED’s
LEDLensBeamAngle 25°
DMX-512 Control 3/4/6Channel Master/Slave
ControlConnections Input: 3-PinXLRMale
Output: 3-PinXLRFemale
Power Requirement 90V~250V, 50~60Hz
Power Consumption 100 Watts
Housing ExtrudedAluminum
Dimensions(HxWxD) 4”x13”x8.5”(less bracket)
Gross Weight 19 lbs.
Model # 555-15610
LEDs 30 x3WRed/Green/Blue/ LED’s
LEDLensBeamAngle 25°
DMX-512 Control 3/4/6Channel Master/Slave
ControlConnections Input: 3-PinXLRMale
Output: 3-PinXLRFemale
Power Requirement 90V~250V, 50~60Hz
Power Consumption 120 Watts
Housing ExtrudedAluminum
Dimensions(HxWxD) 4”x13”x8.5”(less bracket)
Gross Weight 19 lbs.
www.mcmelectronics.com 11
StellarLabsproductare:
DistributedExclusivelyby
MCMElectronics
650Congress ParkDrive
Centerville, Ohio45459

www.mcmelectronics.com 10
uDonotinstall nearanysource ofheatsuchas radiators, heaters,other
heatproducingitems.
uConnecttoapowersource thatprovides between90~240VAC,
50~60Hzonly.
uTomaintainthewarranty, use onlywithproper, authorized
accessories, mountinghardwareand cabling.
uUnplugtheproductfromtheACsource duringlightingstormsor
periodsofpotentialpowersource spikes, surges orotherfluctuations.
Product Quality &Compliance
uProductsfromusmeetall requiredsafetystandardsinforce atthe
timeofmanufacturerand arefullycompliantwiththem.
uInspectthepackingbeforeopening, Ifthepackingappearstohave
sustainedsignificantdamage, please takeextracarebeforeusingthe
product.
uIfyou suspecttheproducthas beendamaged, do notuse it. Returnto
yoursupplierimmediately.
uKeepall packagingintheeventthedevice requires transport atlater
date. Warranty
Thisdevice iswarrantedagainstdefectsforaperiodof365 daysfromthe
dateofpurchase.Thiswarrantyincludes manufacturedefectsand failure
duetonormaluse and operation.Failureduetomisuse, excessivewearor
damage, improperinstallationorotherexternalfactorsisnotcovered
underthiswarranty. MCM Electronics isnotresponsibleforany
consequentialoninconsequentialdamagetoanyotherunitorcomponent
incorporatedwiththisdevice.Thereareno otherwarranties, express or
implied, whichextend beyond thisunit, andtherearenowarranties of
fitness foranyparticularpurpose.Thewarrantydoes notcover
consequentialdamageduetodefectiveorimproperuse ofproducts.
www.mcmelectronics.com 3
Introduction
Thankyou foryourpurchase ofthisqualityStellarLabslightingproduct.
TheStellarLabsHighPowerLEDPARLamphas beenspecifically
designedtoincorporatefeatures and performance thatprofessionaldemand,
withstraightforwardfunctionalitythatenables out-of-theboxoperation by
firsttimeusers. It ishighlyrecommendedthatyou readthisdocumentto
ensurefull understandingofthedevices operation andfeatures.
Operation
Thisunit maybeoperatedinoneofthefollowingmodes:
Standalonemode:Utilizingnumerousbuiltinlightingprogramsand its
internalmicrophoneforsoundactivation.
Slavemode:Connectedtoanotherlamp,mirroringtheoperationofthat
lampinStandalonemode.
ExternalDMXcontrol:Alsoinslavemode, withcontrolbeing
accomplishedbyanindustrystandardDMX-512controller.
Initially Powering theUnit
Uponinitialpowerup, theunit will displayAddr.PressingMENU will
displayoneoftheDMXchannelmodes (A, PorF),andthedefault DMX
address 001. Notethatthedisplaywill onlyremainlit foraperiodof
approximately20 seconds. Thispreventsthebrightness oftheLEDdisplay
frominterferingwithscenery. Pressinganybuttonwill relightthedisplay.
Operating Modes
Asmentionedabove, thestand-alonemodeutilizes multipleinternal
programstoprovideanassortmentofautomaticoperations. While
operatinginthismanner, theunit isalsooperatingas aDMX“master”, in
thatanyconnectedPARlampsin“Slave” modewill mimictheoperation
ofthislamp. Byplacingthislampin“Slave” mode, it allowsit tobe
controlledbyanotherlamp, orDMXcontroller.

www.mcmelectronics.com 4
Ifthisunitisgoingtobeusedinstand-alonemode, skiptothe Built-In
ProgramMode section.
Selecting a DMXMode
Iftheunit isgoingtobecontrolledbyanexternalDMXcontroller,slave
fromanotherLEDLAMP,orsetas aDMXmaster,you mustfirst
determinewhetheryou wouldliketooperatetheunitin3,4or6channel
DMXmode. Naturally, sixDMXchannelsoffersthegreatestflexibility,
whilethree channelsoffersthesimplestoperation, fourchannelmode
beingacompromise betweenthetwo.Thebestsettingwill dependupon
yourindividualsituation.
Toselectoneofthese modes, press theMENU button,thedisplaywill
lightA, PorF,001.PressingENTER, thedisplaywill thenreadcH––.
Press ENTERagain, thedisplaywill showA, PorF, 001.PressingtheUP
orDOWNbutton will scroll throughtheA, PorF, selectingoneofthe
followingDMXmodes:
A–Three ChannelRGB
P–FourChannelRGB, Dimmer+Strobe
F–SixChannelRGB, Strobe+MacroDimmer’
Once thedesiredsettingisreached, press ENTER, cH––will againbe
displayed.
Setting DMXAddress
Once thedesiredmodeisselected,Press TheUPorDOWNbuttonuntil
Addrisshownonthedisplay. Press ENTER, thenuse theUPorDOWN
buttontoselectthefirstDMXaddress oftheunit.Youmayselectany
DMXaddress between001and512.Press ENTERtoconfirm.Addrwill
showagain.TheunitisnowreadytooperateinSLAVE mode.
www.mcmelectronics.com 9
Foryoursafety
uTomaintainManufacturersoneyearwarrantyand foryourown
safety, readand followall instructions.
uThereareno userreplacementpartsinsidetheproduct. Donotopen
theproductforanyreason.Thiswill invalidateyourManufacturer
Warrantyand mayimpair thesafetyfeatures oftheproduct.
uDonotexpose thisproducttomoisture, rainorotherfluids.
uDonotuse thisproductnearwaterorotherfluids.
uDonotuse theproductifyou suspectit has beendamagedinany
way, includingbeingdropped,ismalfunctioning,orhas been
exposedtoliquidsormoisture.
uTheunit mustberepairedbyanauthorizedservice centeronly.
ManufacturerWarrantyisvoidifunitisopenedormodifiedinany
way.
uOperatorsafetymaybecompromisedifthisproductisnotoperated
and maintainedinaccordance withthedetailscontainedinthis
manual.
uThisappliance mustbegrounded,do notremovetheground
connectionon theplugoranylocation supplyingpowertothis
device.
uBeawarethatproductsareACpoweredand arecapableofproducing
highvoltages fromitscomponentsand has highvoltageinsidethe
cabinet.
Product installation, Useand Maintenance
uKeepthismanualforfuturereference.
uCleantheproductwithacleananddry, non-abrasivecloth.Donot
use solventsorliquidstocleantheproduct.
uTopreventoverheating, donotobstructanyventilation openings, fan
coverorvent.

www.mcmelectronics.com 8
DMX-512
Thisfixtureutilizes industrystandardDMX-512control.Thisenables
precision controlofthisfixturebyanystandardDMXcontroller.
Additionally, it allowsmultiplefixtures tobeconnectedtogether,withthe
firstactingas thecontrollerwithup to31 additionalunitsmimicking(or
mirroring)itsactions.
DMX-512 Cables
DMXcables utilize 110ohm, twistedpair construction, surroundedbya
shield, and connectedwithindustrystandardXLRconnectors. Industry
standardcables areavailablein3-pinor5-pinconfigurations. Thisfixture
utilizes the3-pintype.Whilethese cables appearvirtuallythesameas
conventionalmicrophoneorbalancedaudioXLRcables, use ofthese
cables isnotrecommendedas theymaycause erraticintermittently
unreliableperformance. ProperDMXcables arewidelyavailableat
professionalaudiodealers, and highqualityStellarLabsDMXcables are
availablefromMCM Electronics and itsauthorizeddealers.
DMX-Connections
DMXcontrolleddevices typicallyhaveinput(male)and output(female)
connections. ToconnectmultipleDMXdevices toachain, simplystart at
theDMXcontrollerorfirstDMXfixtureoutput,thentotheinputofthe
second device.Thenconnecttheoutputoftheseconddevice, totheinput
ofthethird, andsoonuntilyou reachtheendofthechain.Atthelast
device, connectaDMXterminatortotheoutput.
See www.mcmelectronics.com foracompleteassortmentofDMXcables
ofvaryinglengths, DMXcontrollers, and DMXterminators.
www.mcmelectronics.com 5
Built-InProgramMode
TosettoProgramMode, press the MENU buttontoreturntotheroot
menu. Fromtherootmenu, you canuse the UP or DOWN buttonsto
scroll through all builtinprograms, as well as selectthenumberofDMX
channelsandtheDMXaddress. Followingarealistofthebuilt-in
programs.Withineachprogramistheabilitytoselectanumericvalue
between00~100. Forexample, ifyou selectthefirstprogram, RL––, you
thenpress ENTER, and 100will bedisplayed. UsingtheUPand DOWN
keys,you mayselectanyvaluefrom00~100. Once thedesiredvalueis
achieved, press ENTERtolockthatvalue.
Followingisalistofthemenu optionsinorderofappearance, when
pressingtheUPbutton:
Addr SettingtheDMXaddress,001~512
cH–– SettingthenumberofDMXchannels, 3/4/6
rL–– IndividualRedcolorcontrol.000 full off, 100 full on.
9L– –IndividualGreencolorcontrol.000 full off, 100 fullon.
Bl– –IndividualBluecolorcontrol.000full off, 100 fullon.
FLAS Setsflashstroberateforthecolorselectedbytheabove
individualcolorsettings. Ratesetat000isslowest, to100
whichisfastest.
FAdE Allowsfadebetweenall availablecolorblends. Ratesetat000
isslowest, to100 whichisfastest.
ASC– Allowshardchangehetweenall availablecolors. Ratesetat
000isslowest, to100whichisfastest.
AuTo Automaticallyand randomlyselectsbetweenall oftheabove
describedmodes, forarandomhighenergyeffect. Selectinga
valuebetween000~049allowstimedchanges fromonemode
tothenext. Selectingavaluebetween050~100causes mode
changes tobesoundactivated.

www.mcmelectronics.com 6
DMXChannels
FollowingshowsthecompletelayoutoftheDMXchannels. Thiswill aid
insettingup programming, especiallywhentheunitistobecontrolledby
anexternalDMXcontroller.
3Channel –ModeA Range
1 Red 0~255
2 Green 0~255
3 Blue 0~255
4Channel –ModeP Range
1 Masterdimmer 0~152
Strobe (slow tofast) 153~196
AutoStrobe (slow tofast) 197~242
RGBdimmer 243~255
2 Red 0~255
3 Green 0~255
4 Blue 0~255
www.mcmelectronics.com 7
6Channel –ModeF Range
1 Red 0~255
2 Green 0~255
3 Blue 0~255
4 Nofunction 0~1
Strobe (slow tofast) 2~196
AutoStrobe (slow tofast) 197~255
5 Nofunction 0~1
ColorFade (slow tofast) 2~19
ColorHard Change
(slow tofast)
20~39
ColorFree(slow tofast) 40~59
Yellow 60~79
Violet 80~99
Light Green 100~119
Orange 120~139
Red ON/OFF 140~159
GreenON/OFF 160~179
Blue ON/OFF 180~199
Light Yellow ON/Off 200~219
CyanON/OFF 220~229
White ON/OFF 230~249
All ON 250~255
6 Dimmer 0~255
This manual suits for next models
1
Table of contents
Other stellar labs Floodlight manuals
Popular Floodlight manuals by other brands

FEST
FEST SYSLITE DUO Original operating manual

LI-TIAN LIGHTING
LI-TIAN LIGHTING LT-ALP-20W-MA installation instructions

Red Arrow
Red Arrow FLSMD50Y-1 installation instructions

Show Pro Industries
Show Pro Industries LEDWSH360 user manual

DeWalt
DeWalt DC509 manual

Lightronics
Lightronics FXLD136RGB owner's manual