Sun-Tech T-780K User manual

1
T-780K operation manual
1.T-780K system features:
(1) The controller has 8 output ports, each port can carry up to 170/512/768 pixels(Different pixels for
different chips).
(2) The controller port output two kinds of signal protocol: ①DMX512/1990 international standard protocol
and DMX512 extended protocol; ②SPI/TTL serial protocol.
(3) The controller output port provides three protections to ensure that the controller output port is not burn
out in the case of short circuit or reverse connection in the controlled lamp.
(4) Controller ID automatic/manual numbering function, which can be numbered together with multiple
controllers, or individual controller numbers.
(5) The controller comes with built-in effects to test on-load luminaires (all supported by RGB/RGBW
luminaires).
(6) The controller has DMX512 write function and address test. The single port or all ports carry the
DMX512 IC write address and perform address test on the luminaire.
(7) The communication between the controllers adopts the international standard TCP/IP network protocol.
The optional transmission rate supports 100M/Gigabit adaptation, and the transmission speed is more
stable and fast. The maximum transmission distance between each two controllers can reach 100
meters. More than this distance can increase the switch or use fiber for long-distance transmission.
(8) The controller provides an LCD screen display that shows the model, ID, and operating status of the
controller.
(9) When connected with our online video software LedPlayer for computer control, the connection status
of the controller is monitored in real time on the computer. Using the online video software LedPlayer
for computer control can realize: program timing playback, program segment selection, effect
brightness adjustment, white balance online adjustment, program playback speed adjustment, display
text, picture loop playback, etc., which greatly satisfy the customer's application and Multiple needs in
debugging.
(10) The online video software LedPlayer comes with Gamma correction, which makes the color display
more delicate and vivid.
www.suntechlwww.suntechleds.com sales@suntechleds.com

2
(11) When the controller is connected to the computer, the IP address is set. The controller supports online
and offline integrated control. The online priority is the highest. When there is no online signal, it
automatically switches to the offline effect.
Note 1: The DMX/1903 IC on the controller can be controlled by MADRIX software. The maximum normal
3 unit (3 Univ) lamps per port, that is 3*170 pixels; multi-controllers combined into the largest control
system Compatible with 2048 units.
Note 2: The controller supports rack-mounting. If necessary, please contact the relevant business
personnel before placing an order.
2.Support chips:(Software select T-780K)
Support chips Max. support
light
Reamrks
International standard DMX512(like: UCS512, SM512,
TM512, GS512 etc
)
4096 pixels
Suggest to carry
2400 pixels
UCS19**,ucs29**,ucs89**,ucs1603,ucs5603(UCS full series
TTL/SPI signal IC) 6144 pixels
Suggest to carry
4096 pixels
SM16703,09,12,SM16716,16726(SM full series TTL/SPI signal
IC)
6144 pixels ——
TM18** series, TM19** series 6144 pixels
——
WS28**(WS full series TTL/SPI signal IC)
6144 pixels
——
GS8205,8206,8208
6144 pixels
——
P9813,9823,9883 6144 pixels
——
APA102
6144 pixels
——
SK6812
6144 pixels
——
MY9231 6144 pixels ——
GW6205
6144 pixels
——
INK1003
6144 pixels
——
LX1003,1103,1203 etc 6144 pixels ——
NOTE: More ICs are not listed one by one. For details, please refer to the on-board chip of the PCEdit software of the
PC software, or consult our sales and technical staff.
3.Product picture
T-780K front view
www.suntechlwww.suntechleds.com sales@suntechleds.com

3
T-780K reverse view
4.Indicator and button definition
(1) Indicator
Power
Power indicator (always light after power on)
Status
Status indicator(Always on during normal operation /Strobe when writing)
(2) Cascaded signal input and output port
Cascaded signal NOTE
INPUT Cascaded signal
input network port
The upper output is
connected to the
controller IN;
OUT is connected to
the next level controller
INPUT: Strobe with signal input
OUTP
UT
Cascaded signal
output network
port
OUTPUT
Strobe with signal output
(3) Signal output port
OUT1--O
UT8
Port definition
Signal type 1 2 3 4
Signal output
(
TTL/SPI
Signal)
GND(Negativ
e)DAT data ---- CLK clock
Signal output
(
DMX512
signal)
GND(Negativ
e)
A/DAT+
Signal
positive
B/DAT-
Signal
negative
ADDR
address
writing
(4) Button function
1.OFF/ON 2.LCD display screen 3.SET 4.MODE
5.SPEED+ 6.SPEED- 7.Power indicator 8.Status indicator
9.Cascade input network port INPUT 10.Cascade output network port OUTPUT 11.Output port OUT1-OUT8 12.AC100-240V power interface
www.suntechlwww.suntechleds.com sales@suntechleds.com

4
SET
MODE
SPEED+
SPEED-
Play/Regular
mode
/ / / /
Numbering
mode
Numbering start
button
/ Number up Number down
Parameter
setting mode
Paramter
setting/enter
Item selection Parameter
adjustment +
Parameter
adjustment -
MADRIX
control setting
Chip selection Mode
selection
Speed + Speed -
Remarks
Normally boot into
normal mode, the
button has no
effect
Press "SET" to
boot and enter
parameter
setting/functio
n setting
Press“+” to
bootand enter
MADRIX
control setting
Press “—” to boot
and enter
numbering mode
(5) Display definition:
Display
Definition
Playback
mode
ID: 001(number is 1)
PLAY >>> online/ master control
playback
STOP >>> Online/master control-
pause
Regular
mode
ID: 001( number is 1)
A/C: Automatic/manual coding
T-800K controller model
Numbering
mode ID:*** Starting number
Build-in
playback
effects
CHIP: chip 3:light channel
MOD: built-in effects SPD: Playback
speed
DMX512IC
Address
writing
mode
The definition refer to
7.2 DMX512IC
Addressing Mode and Test
Lamp
address
test mode
See 7.3 Lamp Address Test Mode for
definition in this book.
MADRIX
control
The definition refer to this book 8
MADRIX control mode.
www.suntechlwww.suntechleds.com sales@suntechleds.com

5
5.Wiring diagram
(1) Computer online wiring diagram
(2) Offline master control wiring diagram
(3) Online and offiline use wiring diagram
(4) Controller signal output pirt wiring diagram
①.Regular laight wiring diagram ②.DMX512 differential signal wiring diagram
www.suntechlwww.suntechleds.com sales@suntechleds.com

6
③. DMX512 single signal line wiring diagram ④. DMX512 differential signal wiring
diagram
(AB wire to write address)
(5) Controller--Online mode--Computer IP address
setting
①Turn on the computer --- network and
sharing center;
②Click to change the adapter settings;
③Click on Local Area Connection -
Properties;
④Click on "Internet Protocol Version 4
(TCP/IPV4)";
⑤Change IP
IP:192.168.60.2
Subnet mask:255.255.255.0
⑥Click OK to complete the IP address setting.
Note: This IP setting is applicable to regular online/Madrix software control.
6.T-780K numbering function operate
T-780K numbering has three methods: Computer number (recommended), master
number, and branch number.
(1) Controller (computer software port) numbering
1.1. The computer and the controller are connected by a network cable (using the
www.suntechlwww.suntechleds.com sales@suntechleds.com

7
international standard TCP/IP network protocol, and the network cable is 568B
through)
1.2. Open the software LedPlayer-k and click on "Project Configuration" as shown in
Figure 1.
1.3. Click on "Online Code", as shown in Figure 2.
1.4. Set the controller start number, click the online number button, start numbering, as
shown in Figure 3.
Figure 1 Figure 2 Figure 3
1.5. Complete the online code and check the controller number.
(2) Conttoller(master control operation ) numbering function
The main control and sub-control (T-780K) are connected through the network cable (using the
international standard TCP/IP network protocol, and the network cable is 568B through).
2.1. The master control presses the “SPEED-/speed-” button to power on, and the “MODE” button
adjusts the arrow to “Set Slave ID” as shown in the figure:
2.2. Press the “SET” button again, the main control display enters the numbering page, the “SPEED+”
button and the “SPEED-” button adjust the number of the starting sub-control, as shown below:
2.3. After completing the number setting, press the “SET/Save” button to start the numbering.
www.suntechlwww.suntechleds.com sales@suntechleds.com

8
2.4.The first step of the controller number is to automatically count the number of sub-controls. The
display "Write OK: 003" (take 3 sub-control numbers as an example)
2.5. The number is completed, the main control display: As shown in the figure "Write Num: 003", 3
controllers are programmed.
“ Last ID: 003” means the last controller number is 3
Sub-control T-780K display as below:
First set ID:0001 Second set ID:0002 Third set ID:0003
2.6. Check the controller number. If you need to renumber, press and hold the “SPEED-”
button to restart the numbering. If you do not need to renumber, press any
button—the master restarts and returns to the playback mode.
Note 1: When the controller is numbered, the level network port must be connected in strict accordance
with the controller silkscreen prompt (IN/OUT); the maximum sub-control number is 203. .
(3) Controller (T-780K sub-control) numbering
The T-780K and the T-780K use network cable connect (using the international standard TCP/IP
network protocol, the network cable is 568B straight)
3.1. The first T-780K controller, press and hold the “SPEED-” button, the controller will be powered
on and enter the manual coding mode. The display shows: “ID: 0001” as shown in the figure, ie
the current number of the controller is No. 1, press the “ SPEED+” and “SPEED-” keys adjust
the starting number.
www.suntechlwww.suntechleds.com sales@suntechleds.com

9
Button silk
screen
SET MENU SPEED+ SPEED-
Button function Numbering start / Digital plus Digital subtraction
NOTE Numbering mode, "MODE"
button is not available
Press "-" to power on, enter the
numbering mode
3.2. After completing the start number adjustment, press the “SET” button to start the
number start number and display: “Writing...”
3.3. During the numbering process, the controller detects the number of connected
controllers (the number of connected controllers). As shown in Figure 003, a total
of three controllers are detected.
3.4. The number is completed, the first controller displays: as shown in the figure "Write
Num:003": 3 controllelers are searched
" Last ID: 003" The last one is numbered 3
Other controller display, as show in the figure:
“ID:0002 A” ;ID:0002 means the controller number is No. 2 A: Indicates that the
number is automatically generated
The second set: A-0002 The third set: A-0003
3.5.Check whether each controller number is correct or needs to be renumbered. Then the
first T-780K controller long time presses the “SPEED-” button to return to the manual
numbering; the end numbering can be exited by pressing the button (any button is ok).
The first T-780K controller restarts “Restart...” and returns to normal play mode.
Note: When the controller is numbered, the cascaded networking ports must be connected in strict
accordance with the controller silkscreen prompt (INPUT/OUTPUT).
7.T-780K parameter setting and function operation
Press the “SET” button, and the controller will start up and enter the
www.suntechlwww.suntechleds.com sales@suntechleds.com

10
parameter setting and other function interfaces.
①.PLAY Built-in effect playback mode
②.WRITE ADDRESS Address writing mode
③.TEST DMX ADDR Lamps address testing
mode
④.RGB,RGBW Lamps channel selection
mode
⑤.100-BASE Transmission rate selection
mode
(1) Built-in effects mode (support RGB/RGBW these two kinds channel lamps)
1.1. Press the “SET” button, and the controller will start up, enter the parameter setting
and other function interfaces, as shown in the figure:
1.2. Press the “MODE” button to move the arrow to select “PLAY”, then press the “SET”
button to enter the built-in effect playback mode
interface. As shown in the figure:
①.CHIP chip model(refer to the IC model list)
②.3Channel selection(3/4)
③.MOD Built-in effects(refer to the built-in effects list)
④.SPD Playback speed(refer to the speed level corresponding frame list)
Note: When the built-in effect is played, the supported lamp channel is set by the “Lamp
Channel Selection Mode”.
1.3. Button function list
Button silk
screen
SET MODE SPEED+ SPEED-
Function Chip
selection
Mode selection Speed up Speed down
NOTE
Press “SET” to power on, and enter the built-in effects mode
1.4. Press “SET” to switch the IC model
IC model list
1 DMX (standard
250Kbps)
5
TM1803
2 UCS1903 6
GS8205
www.suntechlwww.suntechleds.com sales@suntechleds.com

11
3
SM16703
7
DMX 500K
4
WS2811
1.5. Press “MODE” to switch the built-in effects
Built-in effects list
1
Colorful jump
3
Colorful change
2
Colorful gradient
4
White light gradient
1.6. Press “SPEED+” and “SPEED- ” to switch the speed;
Speed lever corresponding frame rate list
Spee
d
Frame
rate/secon
d
Spee
d
Frame
rate/secon
d
Spee
d
Frame
rate/secon
d
Spe
ed
Frame
rate/second
1
4 frame
5
8 frame
9
14 frame
13
23 frame
2
5 frame
6
9 frame
10
16 frame
14
25 frame
3
6 frame
7
10 frame
11
18 frame
15
27 frame
4
7 frame
8
12 frame
12
20 frame
16
30 frame
1.7. After completing the built-in effect playback, shut down and restart to return to normal
mode.
(2) DMX512 IC address writing mode and test
2.1. Press “SET” button, and power on the controller, enter the parameter setting and other
function interface, as how in figure 1.
2.2. Press “MODE” button to move the arrow to select “WRITE ADDRESS” as shown in
the figure.
2.3. Press “SET” button to select “WRITE ADDRESS”,enter into address writing mode
interfac, as show in the figure:
①.START CH:Start channel
(The starting address is set in the range of 0-512,
and the regular is 001.)
②.CH MODE: Interval channel
(Interval channel setting in the range of 0-255)
③.IC :Chip model
(Rfer to DMX512 IC list)
www.suntechlwww.suntechleds.com sales@suntechleds.com

12
④.PORT NUM:Address port
(Refer to the port list)
⑤.RETURN Return to the main interface
2.4. Press the “MODE” button to move the corresponding item of the arrow, and press
“SPEED+”and “SPEED-” to set the start channel/interval channel/IC option/address
port respectively.
1.DMX512 IC list
UCS512A*/B*,TM512AL1/
AB
WS2821
DMX512AP
UCS512C*
,
TM512AC*
SM1651*-3 SM1651*-4 UCS512D*/TM512
AD*
UCS512-E
SM17512* SM17522* UCS512-F TM512AC*
GS8512 SM17500
2. port code list
1
Port OUT1
5
Port OUT5
2
portOUT2
6
Port OUT6
3
Port OUT3
7
Port OUT7
4
Port OUT4
8
Port OUT8
ALL
All ports OUT1-8
NOTE: the contorller supports all ports write address, also supports single
port write address.
2.5. Select down each project, press “SET” start to write the address; then the screen
display as “Writing Addr...”,the port indicator flashing.
2.6. After complete the address writing, the controller automatically switch to the address
testing function, then the screen display
①.AC: **** Automatic test
②.MC: **** Manual test
③.ALL All ports OUT1-8
④.CH MODE:Channel (Interval channel is not adjustable)
Note: The address port is set by the “PORT NUM port number” when writing the address.
2.7. Press “MODE” enter “AC” automatic testing mode, the luminaires begin to run in
succession; the controller displays the following picture:
2.8. Press the “MODE” button again to enter the “MC” manual test mode. “SPEED+” and “SPEED-”
can adjust the pixel points (long press “speed+” or “speed-” can be quickly incremented or
www.suntechlwww.suntechleds.com sales@suntechleds.com

13
decremented), and the lamps will light up one by one; The controller displays the following
picture:
2.9. After the test is completed, press “SET” to exit the channel test and return to the write
address interface.
2.10. After completing the address, restart and restart, return to the normal mode.
(3) Lamps address tecting mode(test all the ports carry lamps of the controller)
3.1. Press “SET”, and at the same time power on the controller, enter the parameter setting and
key, at the same time other function interface 1.
3.2. Press “MODE” button to move the arrow corresponding selection “TEST DMX ADDR”.
3.3. Press “SET” enter the lamps testing interface, as show below in the figure:
①.AC: **** Automatic test
②.MC: **** Manual test
③.ALL:All ports
④.CH MODE:Channel(can amnually select)
3.4. Press “MODE” to start the test, as show in the figure:
3.5. Press “MODE” to switch the testing channel slection;
Press “SET” to switch the manual and automatic channel testing mode;
Press “SPEED+” and “SPEED-” to adjust the lamp numbers under the manual
channel testing mode.
www.suntechlwww.suntechleds.com sales@suntechleds.com

14
Lamp test vocabulary definition
Automatic
mode:AC
Definition
Manual mode:MC
Definition
AC:**** ALL
CH MODE:
RGBW
1 channel
automatic test
MC:**** ALL
CH MODE:
RGBW
1 channel manual
test
AC
:
**** ALL
CH MODE:
RG,BW
2 channel
automatic test
MC
:
**** ALL
CH MODE:
RG,BW
2 channel manual
test
AC:**** ALL
CH MODE: R,G,B
3 channel
automatic test
MC:**** ALL
CH MODE: R,G,B
3 channel manual
test
AC:**** ALL
CH MODE:
R,G,B,W
4 channel
automatic test
MC:**** ALL
CH MODE:
R,G,B,W
4 channel manual
test
Note 1: Automatic and manual test mode switching: AC is the automatic test mode, MC is the manual
test mode, and is switched by the “SET” key;
Note 2: luminaire channel switching, RGBW is a monochrome single-channel luminaire; RG, BW is a
two-color two-channel luminaire; R, G, B are three-color luminaire; R, G, B, W are RGBW
four-color luminaire, by "MODE ”Key switch;
Note 3: **** is the lamp number; in the automatic test mode, after the number is automatically
incremented to the maximum value, the test starts again from 0001; in the manual test mode, the
number is manually adjusted by “SPEED+” and “SPEED-”.
3.6. Complete the test, power off and restart, the controller can enter the normal mode.
(4) Lamp channel selection mode (built-in effect playback supports
RGB/RGBW IC channel selection)
4.1. Press the “SET” button, and the controller will start up, enter the parameter setting and
other function interface 1.
4.2. Pess “MODE” move arrow corresponding select “RGB,RGBW”。
4.3. Press “SET” to enter lamps channel selection interface, as show in the below figure:
lamps
①RGB Three channel
②RGBW Four channel lamps
4.4. Press “SPEED+” and “SPEED-” to move the arrow up and down, to select the
RGB/RGBW channel selection.
4.5. Press “MODE” confirm the selection, the two settings as show below:
Or
www.suntechlwww.suntechleds.com sales@suntechleds.com

15
4.6 Select to complete the lamp channel selection, press “SET” to exit and return to the
main interface.
(5) Transmission rate selection mode(100-BASE 100M rate / 1000-BASE Gigabit
rate )
5.1. Press the “SET” button, and the controller will start up, enter the parameter setting
and other function interface 1.
5.2. Press the “MODE” button to move the arrow to select “100-BASE”.
5.3. Press “SET” to enter the signal transmission rate selection mode interface, as shown
in the figure:
①100-BASE 100M rate
②1000-BASE Gigabit rate
5.4. Press the “SPEED+” and “SPEED-” keys to move the arrow up and down to select
the 100-BASE /1000-BASE option.
5.5. Press the “MODE” button to confirm the selection, as shown in the two settings:
OR
5.6. Select to complete the transmission rate selection, press “SET” to exit and return to
the main interface.
5.7. When the controller is in regular program, it shows: GE Gigabit rate / FE 100M rate,
as shown below:
8.T-780K controller ---MADRIX SETTING
Three methods of this setting:
1. Computer software LedEdit-K setting(suggest to use)
2. Computer software setting LedPlayer-K
3. The controller manual setting
(1) LedEdit-k software setting MADRIX parameter
1.1. Open LedEdit-k V4.9.4 and above edition software.
www.suntechlwww.suntechleds.com sales@suntechleds.com

16
1.2. Click <output>--<Set Madrix parameter>
1.3. Enter the setting parameter interface
1.4. Parameter setting
○
1Turn ON/OFF MADRIX
www.suntechlwww.suntechleds.com sales@suntechleds.com

17
Click the drop-down arrow under this option and select Turn ON to turn on /Turn OFF to turn off
the MADRIX mode.
○
2Set the carry light units number
Click on the drop-down arrow for this option and select 1/2/3 unit, which is the number of units
loaded on the controller per port.
NOTE 1:If the controller is set to carry 1 unit per port, the controller 8 port occupies 8 units;
The first controller occupies 1-8 units, as shown in the figure:
The second controller occupies 9-16 units, as shown in the figure:
And so on.
NOTE 2:If the controller is set to carry 2 units per port, the controller 8 port occupies 16 units; the first
controller occupies 1-16, the second controller occupies 17-32, and the third controller occupies
33-48 ,And so on.
NOTE 3:If the controller is set to carry 3 units per port, the controller 8 port occupies 24 units; the first
controller occupies 1-24, the second controller occupies 25-48, and the third controller occupies
49-72 ,And so on.
NOTE 4:The T-780K control system supports up to 2048 units of output, 170 pixels per unit.
○
3Support lamps IC model
Click on the drop-down arrow for this option and select DMX /1903, DMX512 chip
fixtures or regular 1903 fixtures.
○
4After setting, click the <SEND> send button to send the parameters to the controller.
(2) LedPlayer-K software set MADRIX parameter
2.1. Open LedPlayer-k V4.9.2 over edition software.
2.2. Click <Project configuration>--<set Madrix parameter>
www.suntechlwww.suntechleds.com sales@suntechleds.com

18
2.3. Enter parameter setting interface ( Setting method is same with LedEdit)
(3) T-780K controller set MADRIX parameter
Press “SET”, and power on the controlller at the same time, enter MADRIX setting interface,
as shown below:
○
1SET MADRIX Turn on/off MADRIX software
○
2SET Univ Set support lights quantity
○
3 SET IC support IC selection
Note: The parameters need to be set and set in order of 1, 2, 3, and the controller will be
restarted after completion.
3.1. Turn on/off MADRIX function
3.1.1. Press “SET”, and turn on the controller at the same time, enter the MADRIX
setting parameter interface.
3.1.2. Press the “MODE” button to move the arrow to select “SET MADRIX” to
enable/disable the MADRIX function, as shown below.
3.1.3. Press “SET” to confirm entry, open/close Mai Jue; as shown below;
1. Open MADRIX function
2. Close MADRIX function
3.1.4. Press the “SPEED+” and “SPEED-” buttons to move the arrow up and down to
select the On/Off option.
3.1.5. Press the “MODE” button to confirm the selection and display the following picture:
www.suntechlwww.suntechleds.com sales@suntechleds.com

19
OR
3.1.6. Select to complete the selection, press the “SET” button to exit, and return to the
MADRIX setting interface.
3.2. Set the number of lamps on board
3.2.1. Press the “SET” button, and the controller will start up and enter the Mai Jue set
parameter interface.
3.2.2. Press the “MODE” button to move the arrow and select “SET Univ” to set the
number of lamps on the load, as shown below.
3.2.3. Press “SET” to confirm the entry and set the number of lamps on load; as shown
below; ○
1 Univ 1 1 unit(170 pixels)
○
2 Univ 2 2 units(340 pixels)
○
3 Univ 3 3 unites(510 pixels)
3.2.4. Press the “SPEED+” and “SPEED-” keys to adjust the number and select the
controller load unit option.
3.2.5. Press the “MODE” button to confirm the selection and display the following
picture.:
OR OR
3.2.6. Select to complete the selection, press the “SET” button to exit, and return to the
MADRIX setting interface.
3.3. Support IC selection(UCSS1903/ DMX512)
3.3.1.
Press the “SET” button, and the controller will start up and enter the MADRIX set
parameter interface.
3.3.2. Press the “MODE” button to move the arrow to select “SET IC” and select the
model of the loaded IC, as shown below.
www.suntechlwww.suntechleds.com sales@suntechleds.com

20
3.3.3. Press “SET” to confirm the entry and set the number of lamps on load; as shown
below;
○
1DMX DMX512 IC lamps
○
2UCS1903 UCS1903 IC lamps
3.3.4. Press the “SPEED+” and “SPEED-” buttons to move the arrow up and down to
select the IC option.
3.3.5. Press the “MODE” button to confirm the selection and display the following
picture:
OR
3.3.6. Select to complete the selection, press the “SET” button to exit, return to the
MADRIX setting interface, restart the controller to complete the settings.
9.Physical parameter
Working temperature: -20 ° C - 85 ° C
Working power supply: AC 100-240V
input
Power consumption: 5W
Weight: 1.8Kg
Output type: 4pin terminal block
Appearance size: L310 * W152 * H42
Outer packaging: (4pin terminal block *8; power cord *1; paper box *1)
www.suntechlwww.suntechleds.com sales@suntechleds.com
Table of contents
Other Sun-Tech Controllers manuals
Popular Controllers manuals by other brands

AMX
AMX NetLinx Integrated Controller NI-2100 quick start guide

Johnson Controls
Johnson Controls VA9204-B-2 Series installation guide

DNF Controls
DNF Controls ST30 user manual

DriSteem
DriSteem D77 Installation, operation and maintenance manual

Regin
Regin TT-S6/D instructions

IR Robot
IR Robot mightyZAP user manual