Sun-Tech SHB160 User manual

Focus on customized architectural lighting
------------------------------------------------------------------------------------------------------------------------------------------------------------
LED Flood Light Specification
Picture
SHB160 floodlight is a high-power LED floodlight product specially designed for outdoor
landscape lighting. Adopting high thermal conductivity die-casting aluminum shell, with high
thermal conductivity and weather-resistant PU glue potting + sealing ring double waterproof; the
appearance of the lamps is exquisite and generous; the lamps are connected by national
standard flexible cables, which can be bent or deformed at will; the appearance and luminous
color can be customized ; Mainly used for decorative lighting and brightening of building
outlines, overpasses, monuments, columns, flower beds and other places.
★Standard DMX512 control
protocol
★Integrated power supply design, the
power supply method is simpler
★Special protection design for
outdoor lightning protection and
static electricity
★Adopt intelligent control
products, support RGB/W
current separate high
brightness adjustable and
special effect design
★The lamp can be adjusted at an angle greater
than or equal to 180°
★Can be equipped with anti-glare cover
★Good heat dissipation performance, high
waterproof level (IP66)
★Sealing ring heightened thermal
conductive glue, full potting, double
waterproof design
★Professional optical design, fine and uniform
light mixing, long projection distance
Product features & Product Dimension(mm)

Focus on customized architectural lighting
------------------------------------------------------------------------------------------------------------------------------------------------------------
Product Parameters
Basic parameters
Optical parameters
Voltage
DC24V
Power
24~
36W(Customiz
ed)
Power
Source
3030 / 3535
LED quantity
9/24PCS
Control Way
DMX512/No control
Greyness
65536 / Regular
Color
RGB/White
Ra
≥80Ra
Beam angle
5 °/ 7 °/1 0 °/1 5 °/2 5 °/3 0 °/4 5 ° /6 0 °
Structure parameters
Size
210.0x160.0x85.0mm
shell material
High thermal conductivity die-cast aluminum

Focus on customized architectural lighting
------------------------------------------------------------------------------------------------------------------------------------------------------------
Glass
Tempered glass
Adjustable
angle
>180°
Other Parameters
Working
tempetature
-20°C to 60°C
IP Grade
IP66
Storage
temperature
-20°C to 55°C
Electrical
safety grade
III
Lifespan
50,000H
Control Way & Accessory
DMX512
TTL
Main
controller
----
Slave
controller
----
Data
converter
cable
----
Data cable
----
Note:Regular single color product,No need controller or accessory!
Light distribution curve

Focus on customized architectural lighting
------------------------------------------------------------------------------------------------------------------------------------------------------------
Installation Way
一.Installation method
二:Installation operation
Step 1. (As shown above)
Choose a firm and solid mounting base,
and pre-install two M6-M7 expansion
screws horizontally according to the hole
positions of the mounting bracket;
Step 2. (As shown above)
Install the lamp, adjust the direction of the
lamp, and tighten the nut so that the
bracket and the base body are not
loosened;
Step 3. (As shown above)
Adjust the up and down angle of the light
required by the lamp, tighten the angle
adjusting screw, and the lamp cannot be
loosened;
Step 4. (As shown above)
The installation and fixing of the lamps are
completed; according to the standard
electrical wiring requirements, the lamps
are electrically connected.

Focus on customized architectural lighting
------------------------------------------------------------------------------------------------------------------------------------------------------------
System Connection
System connection diagram:
1. The main controller is used with sub-controllers and data converters. The working voltage of the main
control and sub-controllers is AC220V, and the working voltage of the data converter is the same as that of
the light source.
2. Each sub-controller has 8 ports, DMX sub-controllers can have 512 channels per port; TTL sub-controllers
can have 1536 channels per port; supporting data converters can support 200-meter long-distance
transmission.
3. The main control and the sub-controller, and the sub-controller and the sub-controller are connected by
Category 5 twisted pair, the maximum distance of each section is not more than 120 meters; the maximum
transmission distance between the sub-controller and the data converter is not more than 150 Meters, the
maximum distance from the data converter to the first light point is not more than 2 meters.
4. It is recommended that the maximum point spacing does not exceed 3 meters, which exceeds the
recommended signal amplifier. The middle power supply box can hold the current supply of 7.5A at each of
the left and right ends, and the power supply distance can be adjusted appropriately according to the actual
application!
5. If the lamp is monochrome and has no control, there is no need to connect the control part of the
equipment!

Focus on customized architectural lighting
------------------------------------------------------------------------------------------------------------------------------------------------------------
Precautions:
1. Please read the product manual carefully before installing and using the product;
2. Handle the product with care to avoid damage to the product, please leave it to a professional for
installation, repair and maintenance;
3. Please understand clearly the label on the lamp connector when wiring;
4. The external power supply must be cut off when wiring to prevent electric shock or damage to the lamp.
The product must be installed before it can be powered on;
5. When the power cord is connected externally, corresponding waterproof and water leakage measures
must be taken;
6. Regularly clean the dust of the lamp housing and radiator to maintain good heat dissipation
performance;
7. Be careful not to clean with water or strong corrosive solutions, it is best to use a dry cloth;
8. Quality assurance: Under normal conditions of use, quality assurance is based on the correct
preservation, installation, use and maintenance of the product.
(Note: Product damage caused by improper installation and use or violation of product operating
regulations is not within the scope of product warranty)
Table of contents
Popular Floodlight manuals by other brands

Venue Lighting Effects
Venue Lighting Effects revolver laser manual

hylite
hylite HLF060 Assembly & fitting instructions

NightSearcher
NightSearcher Solaris Maxi 20K Series user manual

Cooper Lighting
Cooper Lighting XF Falcon Specifications

involight
involight OB320 user manual

LEXMAN
LEXMAN KCL01-20L Assembly, Use, Maintenance Manual