SUPER-CAN INDUSTRY GROWING GROUP CO.,LTD. LD611-54043 User manual

User Manual
LED PAR 54*3W RGBW
Model: LD401-5403 / LD611-54043 / LD611-54041
2018.03.22
This product manual contains important information about the safe installation
and use of this product. Please read and follow these instruction carefully and
keep this manual in a safe place for future reference.

- 1 -
1Understanding of Product
1.1 Safety Warning
When unpacking and before disposing of the carton, check if there is any transportation damage
before using the product. Should there be any damage caused by transportation, consult your
dealer and do not use the apparatus.
This product is suitable for indoor and outdoor, its protection grade is IP65.
Do not install the product or project the beam onto inflammable surfaces. Minimum distance is 5 M
.
The product is only intended for installation, operation and maintenance by qualified personnel.
And read the user manual and labels on the lighting carefully before use.
Product should install in a cool place. Keep away from the wall 50cm.
Do not look directly at the lamp light (especially for epilepsy), so as not to cause damage to the
eyes.
Keep the optical system clean. Do not touch the LED lens with bare hands. Do not use any alcohol
liquid or any other liquid to clean the optical system. Use medicinal absorbent cotton to clean it.
Please do not attempt to dismantle and/or modify the product inner structure. Otherwise, would not
provide 1 year of free warranty.
Electrical connection must only be carried out by qualified personnel.
Before installation, ensure that the voltage and frequency of power supply match the power
requirement of the product.
It is essential that each product is correctly earthed and that electrical installation conforms to all
relevant standards.
Do not connect this device to any other types of dimmer apparatus.
Make sure that the power-cord is never crimped or damaged by sharp edges. Never let the
power-cord come into contact with other cables. Only handle the power-cord by the plug. Never
pull out the plug by tugging the power-cord.
There is no user serviceable parts inside the product, do not open the housing and never operate
the product with the cover removed.
Place the unit where kids can't reach.
If you have any questions, don't hesitate to consult our dealer or manufacturer.
Important: Before any installation, maintenance and cleaning, please
ensure that the power cut off!

- 2 -
1.2 Technical Parameters
Power supply
Power Rated: AC100~240V 50~60Hz ±10%
Max Power: 180W
LED
LED Chips: 54pcs x 3W 14xRed / 14xGreen / 14xBlue / 12xWhite
Drive Current: 650-700mA
Refresh Frequency: 4KHz
Colors: 16.7 million colors
Life Time: > 20K hours
Control
Control Signal: DMX-512
Channel Mode: 5 kinds channel modes. 4Chs / 5Chs / 6Chs / 7Chs / 10Chs Change by menu.
Control Mode: DMX-512, Auto-Run, Master-Slave mode, Static mode.
Auto Effect: 5 kinds of Auto-Run effects.
Optical System
Dimming mode: Normal Dimming 0-100% or Fading Dimming Mode.
Flashing rate: 1~20Hz sync or async.
Beam angle: 15~60°(fix by lens)
Physical
Dimensions: 294 x 220 x 324mm
Net Weight: 2.5kgs
Housing color: Black
Connection: DMX cable IN/OUT, Power cable IN/OUT
Security
Cooling System: Fan Cooling
Operating Environment: Indoor
Operating Temperature:-20°C~40°C

- 3 -
1.3 Product Features
Using the latest LED driver technology from SUPER-CAN, newest intelligent LED Par light can realize
intelligent operation and control through its special menu at the back. It’s more convenient and easy to
operate. This product is designed for building large area spread light, large concerts, outdoor landscape
lighting, wedding scene, small performances, night club, KTV or various performance occasion.
Features:
1) Static color Settings (STATIC).
2) 4K refresh frequency for video camera.
3) Fading dimming technology..
4) Overheating protection function
5) 5 kinds of DMX channel mode.
6) Master-slave control, multi-units for synchronous control.
7) Sync and async strobe function.
2Product Installation
2.1 Power Connection Method
Please connect power as following :
L(live wire)=brown wire E(earth wire)=yellow/green double color wire N(null wire)=blue wire
When connecting power, ensure that the voltage and frequency of power supply match the power
requirement of the product.
This equipment belong to class 1 protection equipment, therefore, the yellow-green double colors wire
must be earthed correctly by qualified personnel. Before installation, ensure that the voltage and
frequency of power supply match the power requirements of product. In power supply and voltage
fluctuation large areas, we suggest you to use 110V or 230V or use voltage regulator to supply power.
After electrical connection, this product will have a few seconds self-check action, self-check finished
can be used.
Input / output power cable should be 2.5 square millimeter copper core.
220V: Each series should be <16 units.
110V: Each series should be <8 units.
Important: It is essential that Yellow/green double color wire is correctly earthed
and that electrical installation conforms to all relevant standards.

- 4 -
2.2 DMX Connection Method
If the lighting working on DMX mode it needs be connected to the DMX controller
For example: if the lighting setup to DMX 8 channels mode, the first DMX address value must be
1st, next device should be plugs 8 (e.g., 1,9,17,25...).
Every DMX address can be reused as needed.
DMX address can be any data between 001 and 512.
Note:
1. As this DMX cable connection should parallel connection, please
don’t connect more than 32 units in one series.
2. If the signal cable between DMX controller and device over 300 meter,
DMX amplifier should be installed.

- 5 -
3Operation Method
3.1 panel functions introduction
MENU:Menu and Return button, For menu selection.
ENTER:Confirm the menu selected function and save function setting.
UP/DOWN:Upward/downward select function or parameter increment selection.

- 6 -
3. 2 Menu Overview

- 7 -
3.3 Static Color Setting (STATIC)
Find "STATIC "menu and press "ENTER " to enter color static setting.
Press "UP/DOWN "button to select "RED ", "GREEN ", "BLUE ", "WHITE ", "STROBE ", press
"Enter" to confirm.
Press "UP/DOWN "button to adjust brightness value.
Press "MENU "button to return, the selected brightness value will be saved.
After setting lighting fixture's static color, restart the lighting fixture's power supply. The setting was
preserved. Exit menu, static color setting will be removed.
Note: When entered this submenu, the light fixture will automatically set
to the data status sent by the master, other light fixtures should be set as
the slave. Then, any other master lighting fixtures must be disconnected,
as well as the DMX signal cables. Otherwise it will cause disordering.

- 8 -
3.4 Autorun Setting (AUTO)
Find "AUTO" menu and press "ENTER "to enter automatic programming setting.
Press "UP/DOWN "button to select "AT.01~05 "5 kinds of auto-run function. Press "ENTER "to
confirm your setting.
After setting the lighting will run on auto run mode. Restart the lighting, the setting was preserved.
Exit menu, auto run mode will be removed.
Note: When entered this submenu, the light fixture will automatically set
to the data status sent by the master, other light fixtures should be set as
the slave. Then, any other master lighting fixtures must be disconnected,
as well as the DMX signal cables. Otherwise it will cause disordering.

- 9 -
3.5 DMX-512 Address setting
Find "DMX "menu and press "ENTER "to enter the address setting.
Press "UP/DOWN "button to change the DMX address value.
Press "ENTER " to confirm or "MENU " to exit, the selected address value will be saved. The lighting
will run on DMX mode.

- 10 -
3.6 DMX Channel Mode selection (PERS)
Find "PERS "menu and press "ENTER "to enter DMX channel mode setting.
Press "UP/DOWN "button to choose different DMX channel modes.
Press "ENTER" to confirm or "MENU " to exit. The setting will be automatically saved.

- 11 -
3.7 Reset All Settings
Find "RESET "menu and press "ENTER "to restore the factory settings.
Restore factory settings parameters:
1. DMX = 001
2. PERS = 4CH
3.8 Temperature control protection State
When the temperature of the LED over 60-65℃, the light fixture will auto slow down the driver current to protect the
LED chips.
When the protection function is activity, the second dot on the LED screen will ON.
If the temperature sensor is not online or broken, the 3rd dot on the LED screen will ON, the lighting only work on
50% mode.

- 12 -
4Control Channel
4.1----4CHs Mode:
Channel
DMX Value
Control function
Detail description
1
0-255
Red Dimmer
Dimming from 0~100%
2
0-255
Green Dimmer
Dimming from 0~100%
3
0-255
Blue Dimmer
Dimming from 0~100%
4
0-255
White Dimmer
Dimming from 0~100%
4.2----5CHs Mode:
Channel
DMX Value
Control function
Detail description
1
0-255
Red Dimmer
Dimming from 0~100%
2
0-255
Green Dimmer
Dimming from 0~100%
3
0-255
Blue Dimmer
Dimming from 0~100%
4
0-255
White Dimmer
Dimming from 0~100%
5
0-09
Normal Dimming Mode
10-50
Linear Dimming speed (DIM=1)
51-100
Fading Dimming Mode (DIM=2)
101-150
Fading Dimming Mode (DIM=3)
151-200
Fading Dimming Mode (DIM=4)
201-255
Fading Dimming Mode (DIM=5)
4.3----6CHs Mode:
Channel
DMX Value
Control function
Detail description
1
0-255
Main Dimmer
Dimming from 0~100%
2
0-255
Red Dimmer
Dimming from 0~100%
3
0-255
Green Dimmer
Dimming from 0~100%
4
0-255
Blue Dimmer
Dimming from 0~100%
5
0-255
White Dimmer
Dimming from 0~100%
5
0-09
Normal Dimming Mode
10-50
Linear Dimming speed (DIM=1)
51-100
Fading Dimming Mode (DIM=2)
101-150
Fading Dimming Mode (DIM=3)
151-200
Fading Dimming Mode (DIM=4)
201-255
Fading Dimming Mode (DIM=5)

- 13 -
4.4----7CHs Mode:
Channel
DMX Value
Control function
Detail description
1
0-255
Main Dimmer
Dimming from 0~100%
2
0-255
Red Dimmer
Dimming from 0~100%
3
0-255
Green Dimmer
Dimming from 0~100%
4
0-255
Blue Dimmer
Dimming from 0~100%
5
0-255
White Dimmer
Dimming from 0~100%
6
0-15
NO Function
STROBE
16-215
sync strobe (slow to fast)
216-255
async strobe
7
0-09
Normal Dimming Mode
10-50
Linear Dimming speed (DIM=1)
51-100
Fading Dimming Mode (DIM=2)
101-150
Fading Dimming Mode (DIM=3)
151-200
Fading Dimming Mode (DIM=4)
201-255
Fading Dimming Mode (DIM=5)

- 14 -
4.5----10CHs mode:
CHs
DMX Value
Functions
Descriptions
1
0-255
Main Dimmer
Dimming from 0~100%
2
0-255
Red Dimmer
Dimming from 0~100%
3
0-255
Green Dimmer
Dimming from 0~100%
4
0-255
Blue Dimmer
Dimming from 0~100%
5
0-255
White Dimmer
Dimming from 0~100%
6
0-9
NO FUNCTION
COLOR MACRO
10-29
RED 100%/GREEN UP/BLUE 0%
30-49
RED DOWN/GREEN 100%/BLUE 0%
50-69
RED 0%/GREEN 100%/BLUE UP
70-89
RED 0%/GREEN DOWN/BLUE 100%
90-109
RED UP/GREEN 0%/BLUE 100%
110-129
RED 100%/GREEN 0%/BLUE DOWN
130-149
RED 100%/GREEN UP /BLUE UP
150-169
Red DOWN /Green DOWN /Blue 100%
170-255
Red 100%/Green 100%/Blue 100%/White 100%
7
0-015
No function
STROBE
16-215
sync strobe(Slow to fast)
216-255
async strobe
8
0-10
NO FUNCTION
11-50
AUTO1
Auto-program effect running
51-100
AUTO2
Auto-program effect running
101-150
AUTO3
Auto-program effect running
151-200
AUTO4
Auto-program effect running
201-255
AUTO5
Auto-program effect running
9
0-255
Auto-Run Speed
10
0-09
Normal Dimming Mode
10-50
Linear Dimming speed (DIM=1)
51-100
Fading Dimming Mode (DIM=2)
101-150
Fading Dimming Mode (DIM=3)
151-200
Fading Dimming Mode (DIM=4)
201-255
Fading Dimming Mode (DIM=5)

- 15 -
5Maintenance
5.1 Product Maintenance
To prolong the life of the product, it is very important to do maintenance work. The environment is hash
outdoors, or if the product is idle for a long time, damp, smoke or particularly dirty surroundings can
cause greater accumulation of dirt on its LED lens cover, fan vents and housing. So it should be cleaned
to maintain an optimum light output and at the same time to prevent it from corrupted by acid gas.
Cleaning frequency depends on the environment in which the fixture operates. Soft cloth and typical
glass cleaning products should be used for cleaning. It is recommended to clean product at least one
every month.
Friendly notice: Please do not use any organic solvent alcohol to clean
housing of the apparatus, lest cause damage.
5.2 Problem fix
Remark:
This product warranty for one year. We provide pay-needed maintenance service after the warranty. But
because of natural and man-made disasters or improper operation caused damage not under warranty
range!
SUPER-CAN INDUSTRY GROWING GROUP CO.,LTD.
MADE IN CHINA
Problems
Action
The product doesn't power
on
Power connection is not correct--Re-connect it.
Power supply is damaged or abnormal. Call a qualified personnel to fix it.
Control section is damaged. Call a qualified personnel to fix it.
Connection of internal circuitry is not correct. Call a qualified personnel to fix it.
The product can turn on, but
LEDs do not emit light and
are out of control
DMX address is wrongly setting up. Resetting it according to instruction.
DMX Signal wrongly connected. Connect it correctly according to instruction.
Control section is damaged. Call a qualified personnel to fix it.
Brightness going down
The product is too hot. Take ventilation measures to make it cooling down.
This manual suits for next models
2