Supera EVC3100 User manual

Waste Gas Evacuation System
Model EVC3100
Supera, LLC Copyright 2023
For Veterinary Use Only


Examination and Preparation for Use
Thank you for ordering an Supera Anesthesia Innovations Product!
We are delighted to have you as a Supera Anesthesia Innovations
customer and want you to be completely satised with your purchase.
Please inspect the contents of your order to see if everything is as you
expected. Should anything not be exactly right or if anything was damaged
in shipping, please contact your sales representative right away for help.
Our goal is to make your new equipment as easy to use and care for as
possible.
This device is meant to be operated under the normal surveillance and
control of a veterinarian trained in its use. However, you need to know more
about this device than just how to operate it.
Please read this manual in its entirety before using the equipment.
If you have any comments or questions, we welcome the opportunity to
address them.
Please contact us directly at 877-620-1500.
Thank you!
Proudly 100% American
Made In Oregon!
MADE IN
oREGON, uSA
since 1993

IMPORTANT INFORMATION
READ AND SAVE THESE INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the manufacturer. If you have questions,
contact the manufacturer.
CAUTION
For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive
Materials And Vapors
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualied person(s) in accordance
with all applicable codes and standards, including re-rated construction.
b) Ducted fans must always be vented to the outdoors.
THERE ARE NO USER SERVICEABLE PARTS INSIDE
Contact Supera LLC directly for all maintenance
and repairs. Technical service phone 877-620-1500
Symbol Chart
This document uses the following symbols to indicate potential hazards or alert the
user to useful information about the unit.
Important Notice – Explanation needed: refer to this manual
High Voltage: Risk of Electrical Shock
Protective Earth Ground

SUGGESTED MOUNTING INFORMATION
The area around the unit must be free of loose dirt and
debris
The area should be well ventilated with a maximum
temperature of 120 deg. F
This is a mechanical pump that emits noise (less than
70dB(A)) at a constant rate.
We recommend the unit be mounted in an area not in
constant use by people or animals.

INSTALLATION INSTRUCTIONS
1. Remove the panel to reveal the terminal block.
2. Attach the ground.
3. Attach the “L1” and “N” wires to the terminal block.
“L1”
Earth Ground
“N”

A EXHAUST - ¼ NPT FEMALE
B INLET TO BUILDING PLUMBING - ¼ NPT FEMALE
C ON/OFF SWITCH WITH CIRCUIT BREAKER
D NOTE: POWER CORD NOT INCLUDED
A
B
C
D
Hold Down Brackets
Screw down unit to a solid structure
(3 screws per side)

RECOMMENDED GUIDELINES
LOCATION
This is a mechanical pump that emits noise at a constant rate.
We recommend the unit be mounted in an area not in constant use by
people or animals.
POWER SWITCH
We recommend controlling the unit through a lighted power switch to
indicate the device is powered ON.
INTAKE
1/4 NPT fitting to ½” copper pipe.
EXHAUST
1/4 NPT fitting to 3/4” copper or 1” scd40 PVC pipe plumbed to outside
the building.
OUTLETS
Any piped gas outlets (WAGD) can be used. No ceiling or wall valves
are needed to control the flow rate, however, all active (suction style)
evacuation systems require waste gas interface (WGI) balance valves on
the anesthesia machines.
WASTE GAS INTERFACE
The EVC629 WGI with built in flow valve is
engineered for this system and requires no additional
calibration or maintenance.
It is mounted on the anesthesia machine and
attached to the pop o valve or non-rebreathing
system via the blue 19mm hose.
It is preset at 10 lpm flow. It can be adjusted higher
using a calibrated flow meter.
NOTE:
This should be done by a professional service
company.

GENERAL INFORMATION
Active Evacuation System
AES – anesthetic evacuation system utilizes a sealed evacuation unit
to remove waste gas to the outside air. The AES wall or ceiling outlets
are plumbed using copper pipe and are connected to the anesthesia
machine through the waste gas interface (WGI) device to balance the
negative pressure.
1-25 Anesthesia Machines
Uses standard wall/ceiling outlets
Plumbed using copper pipe
Uses waste gas interface EVC629 to balance evacuation pressure on
each anesthesia machine.
MAINTENACE
This AES unit is maintenance free.
TROUBLE SHOOTING
1. The no air is owing.
Check the on/o switch. If the switch is half way on/o, the circuit
breaker has been triggered. Reset the switch into the “ON” position.
2. The pump is on but not owing air at the outlets.
Check the exhaust pipe for obstructions (animals, debris, etc.)
Check the intake pipes for loose joints
FOR ALL OTHER ISSUES CALL SUPERA LLC AT 1-877-620-1500


LEI Medical EVC3100 Typical Layout
Copper main line - diameter
determined by length of run.
3
4
" pipe exhaust through roof
or wall to ouitside air
EVC3100
Lighted wall switch
EVC629 Waste Gas Interface (WGI)
Purple WAGD hose from wall
outlet to WGI 19mm BLUE tubing from
WGI to pop off valve
Pop off valve on
anesthesia machine
ceiling configuration
Wall configuration
ceiling
SAMPLE SYSTEM LAYOUT

SPECIFICATIONS
Tech Specs
Oil less operation
All aluminum parts treated for corrosion protection from moisture
Rugged motor shell construction
Electrical
Voltage: 115
Hz: 60
Phase: Single
Full Load Amps: 6.6
Agency Compliance: TUV Listed for US and Canada requirements to
UL507
Construction
303 stainless steel housing
Dimensions
10.5” X 10.5” X 10”
Weight
29 lbs.
Sound Level
Less Than 70 dB(A)
* We recommend the unit be mounted in an area not in
constant use by people or animals.

WARRANTY (PARTS ONLY)
2 years
Supera LLC warrants this product shall be free from defects in work-
manship and materials, under normal use from the date of purchase.
This is a parts warranty. Labor is not included.
Supera LLC warrants only that each such part and item shall be free
from defects in workmanship and materials at the time of delivery. This
warranty shall be void for any product that has been altered, defaced or
removed from the original Supera LLC product.
Supera LLC shall not be liable for any damage, injury or loss arising out
of the use of the product, whether as a result of a defect in the product
or otherwise, if, prior to such damage, injury or loss, the product was
(1) damaged, misused, or misapplied; (2) repaired, altered or modied
by persons other than Supera LLC; (3) not installed in strict compliance
with the applicable codes and ordinances; (4) not installed by Supera
LLC or an authorized Supera LLC dealer.
UNDER NO CIRCUMSTANCES SHALL SUPERA LLC BE LIABLE FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES AS THOSE TERMS
ARE DEFINED IN THE UNIFORM COMMERCIAL CODE.
All items returned for service or repair, are the responsibility of the
customer. Proper packing methods should be used in returning items to
Supera LLC.
Supera LLC.
1220 NW Noble Drive
Estacada, Oregon 97023 USA

SHIPPING POLICY
1. Do Not Sign The Bill Of Lading Until You Have Inspected The Box Or Crate.
2. Examine the box AS it is delivered and BEFORE the truck/driver leaves.
3. If there is any evidence of damage when it arrives, note it in detail with the
phrase “possible concealed damage” on the bill of lading and immediately call
the oce for instructions before the truck/driver leaves if at all possible.
4. If there is obvious damage such as a hole in the box, a crushed box, etc.,
refuse the shipment. The product will then go back to the freight company’s
terminal where they are entirely responsible.
5. Open and inspect your product as soon as possible. DO NOT WAIT.
6. If you nd damage, take as many photographs of everything as soon as you
can and email them to [email protected].
7. Note: unless the following procedures are followed correctly and we are noti-
ed within ten (10) days, SUPERA LLC cannot accept any responsibility for the
problems that may ensue.
DO NOT RETURN ANY DAMAGED GOODS TO SUPERA LLC WITHOUT PRIOR
AUTHORIZATION OF SUPERA LLC AND THE CARRIER.
KEEP ALL PACKAGING!
DO NOT RETURN ANY DAMAGED ITEMS UNTIL SHIPPING INSTRUCTIONS ARE RECEIVED.
ALL CLAIMS MUST BE FILED WITHIN TEN (10) DAYS OF RECEIPT OF GOODS.
IF YOU HAVE ANY QUESTIONS CONTACT SUPERA DIRECTLY AT 503-723-5068.

DOCUMENTATION
Date purchased:
Purchased from:

MADE IN
oREGON, uSA
since 1993
Contact Information
(503) 723-5068 or (877) 620-1500 toll-free
E-Mail: info@superavet.com
1220 NW Noble Drive, Estacada OR 97023
Traning videos available on our website
www.SuperaVet.com
Table of contents
Popular Water Pump manuals by other brands

GÜDE
GÜDE ZWP 180-20 Translation of the original instructions

Milton Roy
Milton Roy G Series Installation, operating and maintenance manual

Samoa
Samoa LARIUS VIKING Operating and maintenance manual

Laing
Laing SM-303-B Installation & operating manual

Taconova
Taconova TACOFLOW2 PURE PLUS 15-14/80 Installation and operating instructions

Oase
Oase promax cleardrain 7000 operating instructions