Test gage connections are provided on the
front of the millivolt gas control valve (iden-
tified IN for the inlet and OUT for the mani-
fold side). A ¹⁄₈" NPT test gage connection is
provided at the inlet and outlet side of
the electronic gas control valve.
Minimum inlet gas pressure to these appliances
is5.0 incheswatercolumn(1.24kPa)fornatural
gas and 11 inches water column (2.74 kPa) for
propane for the purpose of input adjustment.
Maximum inlet gas supply pressure to these
appliances is 10.5 inches water column (2.61
kPa) for natural gas and 13.0 inches water
column (3.23 kPa) for propane.
These appliances must be isolated from the gas
supplypiping system(byclosing theirindividual
manualshut-off valve) duringany pressuretest-
ing of the gas supply piping system at test
pressuresequalto or less than¹⁄₂ psig (3.5 kPa).
These appliances and their individual shut-off
valves must be disconnected from the gas
supplypipingsystem during any pressuretest-
ing of that system at pressures in excess of ¹⁄₂
psig (3.5 kPa).
Do not use these appliances if any part has
been under water. Immediately call a quali-
fied,professional servicetechnician toinspect
the appliance and to replace any parts of the
control system and any gas control which
have been under water.
Ne pas se servir de cet appareil s'il a étéplongé
dans l'eau, complètement ou en partie. Appeler
untechnicienqualifiépourinspecterl'appareil et
remplacertoute partie dusystème decontrôle et
toute commande qui ont étéplongés dans l'eau.
The millivolt appliances are manually controlled
andfeatureasparkignitor (piezo)that allowsthe
appliance's pilot gas to be lit without the use of
matches or batteries. This system provides
continuedserviceinthe eventofapower outage.
WARNING: FAILURE TO COMPLY WITH
THEINSTALLATIONANDOPERATING IN-
STRUCTIONS PROVIDED IN THIS DOCU-
MENT WILL RESULT IN AN IMPROP-
ERLY INSTALLED AND OPERATING AP-
PLIANCE,VOIDINGITSWARRANTY. ANY
CHANGE TO THIS APPLIANCE AND/OR
ITS OPERATING CONTROLS IS DANGER-
OUS. IMPROPERINSTALLATIONORUSE
OF THIS APPLIANCE CAN CAUSE SERI-
OUS INJURY OR DEATH FROM FIRE,
BURNS, EXPLOSION OR CARBON MON-
OXIDE POISONING.
These appliances must not be connected to a
chimney or flue serving a separate solid fuel
burning appliance.
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning are similar to
thefluwithheadaches,dizziness and/ornau-
sea. If you have these signs, obtain fresh air
immediately. Turn off the gas supply to the
appliance and have it serviced by a qualified
professional, as it may not be operating
correctly.
WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE HAZARDS
OFHIGHSURFACETEMPERATURES.USE
CAUTION AROUND THE APPLIANCE TO
AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY ARE IN
THE SAME ROOM AS THE APPLIANCE.
WARNING: DO NOT PLACE CLOTHING
OR OTHER FLAMMABLE MATERIALS
ON OR NEAR THIS APPLIANCE.
AVERTISSEMENT: SURVEILLER LES
ENFANTS. GARDER LES VÊTEMENTS,
LES MEUBLES, L'ESSENCE OU AUTRES
LIQUIDES ÀVAPEUR INFLAMMABLES
ÀCOTE DE L'APPAREIL.
Installations at Altitudes of 0 to 4500 ft.-
Unitsare testedandapproved forelevations
of 0 to 4500 feet (0 to 1372 meters).
Installations at Altitudes above 4500 ft.-
For elevations above 4500 feet (1372
meters), install the unit according to the
regulations of the local authorities having
jurisdictionand,intheUSA,thelatestedition
ofthe NationalFuel GasCode(ANSI Z223.1)
or, in Canada, the latest edition of the
CAN1-B149.1 and .2 codes.
Electronic Models -
Electronic models have a fixed rate gas valve.
Input of electronic models is shown in the
following table:
Input of millivolt models is shown in the
following table:
All Models -
Maximum manifold pressure is 3.5 in. w.c.
(0.87 kPa) for natural gas and 10 in. w.c.
(2.49 kPa) for LP/Propane gas.
Table 1
shows the units' gas orifice size for
theelevationsindicated.
This appliance may be installed in an af-
termarket permanently located, manufac-
tured home (USA only) or mobile home,
where not prohibited by local codes. This
appliance is only for use with the type of
gas indicated on the rating plate. This ap-
pliance is not convertible for use with other
gases, unless a certified kit is used.
Cetappareilpeutêtreinstallédansunmaison
préfabriquée (É.-U. seulement) ou mobile
déjàinstallée àdemeure si les réglements
locaux le permettent.
Cet appareil doit être utiliséuniquement avec
les types de gaz indiqués sur la plaque
signalétique. Nepasl'utiliseravecd'autresgaz
sauf si un kit de conversion certifiéest installé.
,TD,D RD seireS
ezisecifirO noitavelE teeF )sretem(
.taN.porP
005 .ni090.045#
0054-0 )0731-0(
006 63#25#
008 33#.ni560.0
LOCATION
In selecting the location, the aesthetic and func-
tionaluse oftheapplianceareprimary concerns.
However,ventsystemrouting totheexteriorand
access to the fuel supply are also important.
Consideration should be given to traffic ways,
furniture,draperies, etc.,due toelevatedsurface
temperatures (
see Figure 2
).
Millivolt Models -
Millivolt models come standard with the
manually-modulated gas valve; flame ap-
pearance and heat output can be con-
trolled at the gas valve.