Swagelok FDH1 User guide

A Swagelok®Pre-Engineered
Subsystem
• Pre-engineered subsystems
available in weeks, not months.
• Field-tested design ensures
optimum system performance.
• Versatile manifold for gas and liquid applications
• Swagelok components for reliability
• Fluid distribution headers can be connected inline to
create longer lengths
Fluid
Distribution
Header
Application Guide

Swagelok Pre-Engineered
Subsystems
Swagelok now offers a series of
predesigned and preassembled
subsystems for use in all types of
plants and facilities where uids are
being processed. Use Swagelok pre-
engineered subsystems to create fully
documented uid sampling and control
systems and bring consistency to your
operations. Easy to install and operate,
these subsystems offer the high quality
and support you expect from Swagelok.
Contents
Why Use a Fluid
Distribution Header? ....... 3
Using the Fluid Distribution
Header as a
Distribution Manifold ....... 3
Using the Fluid Distribution
Header as a
Collection Manifold ........ 3
Key Features ............... 4
How to Select a Fluid
Distribution Header ........ 5
Materials of Construction ...... 6
Testing .................... 6
Cleaning and Packaging ....... 6
Pressure-Temperature
Ratings ................. 7
Dimensions ................. 8
Ordering Information .......... 14
Swagelok Custom Solutions .... 15
Regulatory Compliance ....... 15

A Swagelok Pre-Engineered Subsystem Fluid Distribution Header
3
The Swagelok
Fluid Distribution Header (FDH)
Why Use a Fluid Distribution Header?
Fluid distribution headers are common components used in a variety of gas and liquid
applications. An FDH provides a ow path while allowing multiple outlets, acting much like a
large branch tting.
A uid distribution header is characterized by an inlet on one end, a drain on the other end, with
multiple outlets on the sides. Typical uid distribution headers are manufactured from a piece of
pipe or bar and feature welded or threaded end connections.
Using the Fluid Distribution Header
as a Distribution Manifold
As a distribution manifold or header, an FDH
connects several users to the source of a
utility uid. Typical applications include:
• Cooling water
• Steam
• Compressed air
• Plant nitrogen
In a typical analyzer house, for instance, one
FDH is an instrument air header, another
FDH is the plant nitrogen header, and yet
another FDH is the LP steam header. If
needed, multiple FDH subsystems can be
screwed together end-to-end to make longer
header runs.
Typically, an FDH has a main isolation valve and several outlets, each with its own isolation valve.
For potentially wet gases, such as compressed air or steam, it is best to install the FDH vertically
with a drain valve at the bottom.
For liquid service, it is best to install the FDH vertically, with the supply entering at the bottom
and the top valve acting as a vent for removing trapped air or allowing air in for draining the FDH
during maintenance.
Typical Swagelok
Fluid Distribution Header (FDH)

A Swagelok Pre-Engineered Subsystem Fluid Distribution Header
4
Using the Fluid Distribution Header
as a Collection Manifold
As a collection manifold or header, an FDH collects several uid streams and provides a single
connection for disposal. Typical disposal points include:
• Low-pressure return to process
• Flare header
• Atmospheric vent
• Drain or sewer
Key Features
The Swagelok FDH is a pre-engineered and fully documented piping assembly that can act as a
distribution manifold or collection manifold in gas or liquid applications.
The Swagelok FDH offers several distinctive features:
• Available in 1 and 2 in. sizes, an extruded manifold body design features squared sides that
mount solidly and prevent twisting.
• Standard branch locations offer exibility; additional outlets can be added to the header
without welding.
• The FDH can be ordered with 2 to 16 branch outlets, with or without valves, so users can
add ports as needed.
• A choice of high-quality valves and end connections, all manufactured by Swagelok.
• Working pressures up to 3000 psig (206 bar).
• Mounting brackets can be positioned by the installer.

A Swagelok Pre-Engineered Subsystem Fluid Distribution Header
5
How to Select a Fluid Distribution Header
Branch outlets: The rst step in selecting an FDH is determining the number and location of
branch outlets. Branch outlets are available on the left, front, and right sides of the system, or on
a combination of two sides.
Gauge: The FDH can be ordered with or without a Swagelok B model pressure gauge, a
general-purpose stainless steel gauge.
Drain valve: The FDH can be ordered with or without a drain valve on the opposite end to drain
the system.
Valve selection: A variety of Swagelok valves
are available to meet temperature and pressure
requirements of specic applications. See page 7
for pressure-temperature ratings.
• Swagelok 40G series instrumentation ball valves
• Swagelok 40 series instrumentation ball valves
• Swagelok 60T series process ball valves
• Swagelok 1 and 18 series integral bonnet needle
valves
• Swagelok P4T and P6T plug valves
Special notes:
The main isolation valve and individual inlet isolation valves are optional when the FDH is used as
a collection manifold.
For gas headers that are installed horizontally, specify the necessary number of inlets on the top
side of the header and one outlet on the underside for a drain valve.
Inlet Valve
Outlet Valves
Drain Valve

A Swagelok Pre-Engineered Subsystem Fluid Distribution Header
6
Materials of Construction
For detailed product data, including additional
seat materials and nonwetted materials of
construction, see individual product catalogs.
Component Manufacturer,
Model Material
1Extrusion Swagelok 316 stainless steel
2End caps Swagelok
3O-rings Various Fluorocarbon FKM
4Mounting
brackets Swagelok 316 stainless steel
5End
connections Swagelok 316 stainless steel
6Adapter
fittings Swagelok 316 stainless steel
7Valves
Swagelok
60series
See Swagelok Ball Valves, General
Purpose and Special Application—
60 Series catalog, MS-01-146
Swagelok 40G
and 40series
ball valves
See Swagelok One-Piece
Instrumentation Ball Valves—40G
Series and 40Series catalog,
MS-02-331
Swagelok 1
and 18 series
needle valves
See Swagelok Integral-Bonnet
Needle Valves—O, 1, 18, 20, and
26Series catalog, MS-01-164
Swagelok P4T
and P6T series
plug valves
See Swagelok Plug Valves—P4T
and P6TSeries catalog, MS-01-59
8Gauge Swagelok B
model
See Swagelok Pressure Gauges,
Industrial and Process—PGI Series
catalog, MS-02-170
Wetted components listed in italics.
Testing
Every FDH subsystem is shell tested
with nitrogen at 250 psig (17.2 bar) to a
requirement of no detectable leakage with a
liquid leak detector.
See individual valve product catalogs for
shutoff testing information.
Cleaning and Packaging
All FDH subsystems are cleaned in
accordance with Swagelok Standard
Cleaning and Packaging (SC-10), MS-06-62.
5
7
7
8
7
2
3
2
1
4
6
3

A Swagelok Pre-Engineered Subsystem Fluid Distribution Header
7
Pressure-Temperature Ratings
Ratings of FDH subsystems are based on the ratings of the extrusion and the valves selected
for the inlet, outlet, and drain. The valve with the lowest pressure rating at any given temperature
limits the pressure rating. The valve with the most restrictive temperature rating limits the
temperature rating. See Ordering Information, page 14, for the availability of each valve
series in inlet, outlet, and drain functions.
For ratings of FDH subsystems with ASME class 150 anges, see ASME B16.5-2003,
Table2-2.2 and TableF2-2.2.
FDH2 (2 in. Pipe Platform)
Inlet, Outlet, or Drain
Valve
None, 1, 18,
P4T or P6T
Series
40
Series
60
Series
Temperature, °F (°C) Working Pressure, psig (bar)
–10 (–23) to 50 (10) 1000 (68.9) —1000 (68.9)
50 (10) 1000 (68.9) 1000 (68.9) 1000 (68.9)
100 (37) 1000 (68.9) 1000 (68.9) 1000 (68.9)
150 (65) 930 (64.0) 930 (64.0) 930 (64.0)
200 (93) 865 (59.5) —865 (59.5)
250 (121) 820 (56.4) —820 (56.4)
300 (148) 780 (53.7) —780 (53.7)
400 (204) 715 (49.2) —330 (22.7)
FDH1 (1 in. Pipe Platform)
Inlet, Outlet, or Drain
Valve
None, 1, or 18
Series
40G or 40
Series
60
Series
P4T or P6T
Series
End Connection Size All 1/4 in.,
6 mm
3/8 to 1 in.,
10to 25 mm All All
Temperature, °F (°C) Working Pressure, psig (bar)
–10 (–23) to 50 (10) 3000 (206) 3000 (206) —2200 (151) 3000 (206)
50 (10) 3000 (206) 3000 (206) 2500 (172) 2200 (151) 3000 (206)
100 (37) 3000 (206) 3000 (206) 2500 (172) 2200 (151) 3000 (206)
150 (65) 2797 (192) 3000 (206) 2500 (172) 1850 (127) 3000 (206)
200 (93) 2595 (178) 2600 (179) —1500 (103) 3000 (206)
250 (121) 2465 (169) 2550 (175) —1150 (79.2) 2000 (137)
300 (148) 2340 (161) 2500 (172) —800 (55.1) 1000 (68.9)
400 (204) 2145 (147) — — 330 (22.7) 1000 (68.9)

A Swagelok Pre-Engineered Subsystem Fluid Distribution Header
8
Dimensions
Dimensions, in inches (millimeters), are for reference only and are subject to change.
FDH Body—A Dimension and Weight
FDH1 inside diameter: 0.79 in. (20.1 mm); FDH2 inside diameter: 1.85 in. (47.0 mm).
Weights include end caps.
Outlet
Branch
Side
Number of
Outlets Per
Side
FDH1 (1 in.
Pipe Platform)
FDH2 (2 in.
Pipe Platform)
FDH1 (1 in.
Pipe Platform)
FDH2 (2 in.
Pipe Platform)
A, in. (mm) Weight, lb (kg)
Valves on
one side
416.5 (419) 19.8 (503) 6.9 (3.13) 16.7 (7.58)
625.5 (648) 30.2 (767) 10.3 (4.67) 24.3 (11.0)
834.5 (876) 40.8 (1036) 13.8 (6.26) 31.9 (14.5)
Valves on
two sides
27.50 (190) 9.25 (235) 3.4 (1.54) 9.1 (4.13)
312.0 (305) 14.5 (368) 5.2 (2.36) 12.9 (5.85)
416.5 (419) 19.8 (503) 6.9 (3.13) 16.7 (7.58)
521.0 (533) 25.0 (635) 8.6 (3.90) 20.5 (9.30)
625.5 (648) 30.2 (767) 10.3 (4.67) 24.3 (11.0)
730.0 (762) 35.5 (902) 12.1 (5.49) 28.1 (12.7)
834.5 (876) 40.8 (1036) 13.8 (6.26) 31.9 (14.5)
R
R R R
B
D
A
C
FDH1
1. 5 0 (38.1)
FDH2
2.00 (50.8)
FDH1
0.80 (20.3)
FDH2
1.36 (34.5)
FDH1
1. 5 0 (38.1)
FDH2
2.00 (50.8)
FDH1
4. 5 0 (114)
FDH2
5.25 (133)
Inlet
Drain
Left Middle Right
Outlets
(see page 10)
(see page 9)
(see page 11)
Optional
gauge port
Shown with outlet branch one side right.

A Swagelok Pre-Engineered Subsystem Fluid Distribution Header
9
Dimensions
Dimensions are for reference only and are subject to change.
FDH1 (1 in. Pipe Platform) Inlet—B Dimension
End Connections
Inlet Valve
No Valve 40G or 40
Series 60 Series
Type Size B, in. (mm)
Female NPT
3/8 in. 0.50 (12.7) 3.87 (98.3) 4.07 (103)
1/2 in. 0.86 (21.8) 5.07 (129) 4.65 (118)
3/4 in. 1.21 (30.7) —5.85 (149)
Fractional
Swagelok
tube fitting
1/2 in. 1.37 (34.8) 4.88 (124) 5.00 (127)
3/4 in. 1.40 (35.6) 4.95 (126) 5.07 (129)
1 in. 1.67 (42.4) —6.54 (166)
Metric
Swagelok
tube fitting
12 mm 1.40 (35.6) 5.96 (151) 6.08 (154)
25 mm 1.69 (42.9) —7.71 (196)
Swagelok
tube adapter
3/8 in. 1.20 (30.5) — —
1/2 in. 1.46 (37.1) — —
3/4 in. 1.59 (40.4) — —
1 in. 1.93 (49.0) — —
ASME class
150 flange
1/2 in. 2.74 (69.6) —6.36 (162)
1 in. 3.56 (90.4) —8.14 (207)
FDH2 (2 in. Pipe Platform) Inlet—B Dimension
End Connections
Inlet Valve
No Valve 40 Series 60 Series
Type Size B, in. (mm)
Female NPT
1/2 in. 0.88 (22.4) 5.09 (129) 4.67 (119)
3/4 in. 0.88 (22.4) —5.52 (140)
1 in. 0.88 (22.4) —5.86 (149)
Fractional
Swagelok
tube fitting
1/2 in. 1.62 (41.1) 5.13 (130) 5.25 (133)
3/4 in. 1.62 (41.1) 5.13 (130) 5.25 (133)
1 in. 1.79 (45.5) —6.66 (169)
2 in. 3.19 (81.0) —12.3 (312)
Metric
Swagelok
tube fitting
25 mm 1.80 (45.7) —7.71 (196)
50 mm 3.19 (81.0) — —
Swagelok
tube adapter
3/4 in. 1.77 (45.0) — —
1 in. 2.05 (52.1) — —
2 in. 3.51 (89.2) — —
ASME class
150 flange
1/2 in. 2.99 (75.9) —6.61 (168)
1 in. 3.68 (93.5) —8.23 (209)
2 in. 6.43 (163) —15.2 (386)
B
40 Series Inlet Valve
with Swagelok
Tube Fitting End
Connections Shown

A Swagelok Pre-Engineered Subsystem Fluid Distribution Header
10
Dimensions
Dimensions are for reference only and are subject to change.
FDH1 (1 in. Pipe Platform) Outlet—D Dimension
End Connections
Outlet Valve
No Valve 40G or 40
Series 60 Series 1 or 18
Series
P4T or P6T
Series
Type Size D, in. (mm)
Female NPT
1/4 in. 0.80 (20.3) 3.72 (94.5) 3.82 (97.0) 3.78 (96.0) 4.04 (103)
3/8 in. 2.03 (51.6) 4.18 (106) 4.38 (111) 4.68 (119) —
1/2 in. 2.29 (58.2) —4.50 (114) 4.80 (122) 4.68 (119)
Fractional
Swagelok
tube fitting
1/4 in. 2.02 (51.3) 3.89 (98.8) 4.85 (123) 3.95 (100) 3.85 (97.8)
3/8 in. 2.10 (53.3) 4.73 (120) 4.85 (123) 4.26 (108) 4.34 (110)
1/2 in. 2.24 (56.9) —5.82 (148) 4.58 (116) 4.66 (118)
Metric
Swagelok
tube fitting
6 mm 2.02 (51.3) 4.11 (104) 4.89 (124) 3.99 (101) 3.89 (98.8)
10 mm 2.14 (54.4) 4.79 (122) 4.92 (125) 4.32 (110) 4.40 (112)
12 mm 2.24 (56.9) —5.90 (150) 4.66 (118) 4.82 (122)
Swagelok
tube
adapter
1/4 in. 1.99 (50.5) ————
3/8 in. 2.06 (52.3) ————
1/2 in. 2.28 (57.9) ————
FDH2 (2 in. Pipe Platform) Outlet—D Dimension
End Connections
Outlet Valve
No Valve 40 Series 60 Series 1 or 18
Series
P4T or P6T
Series
Type Size D, in. (mm)
Female NPT
3/8 in. 2.39 (60.7) 4.85 (123) 5.05 (128) 5.35 (136) —
1/2 in. 1.36 (34.5) 5.57 (141) 5.15 (131) 5.45 (138) 5.33 (135)
3/4 in. 3.00 (76.2) —6.02 (153) — —
1 in. 3.14 (79.8) —5.24 (133) — —
Fractional
Swagelok
tube fitting
3/8 in. 2.80 (71.1) 5.44 (138) 5.56 (141) 4.97 (126) 5.05 (128)
1/2 in. 2.91 (73.9) 6.40 (163) 6.52 (166) 5.28 (134) 5.36 (136)
3/4 in. 2.97 (75.4) 6.40 (163) 6.52 (166) 6.28 (160) —
1 in. 3.24 (82.3) —7.90 (201) — —
Metric
Swagelok
tube fitting
10 mm 2.81 (71.4) 5.50 (140) 5.63 (143) 5.03 (128) 5.11 (130)
12 mm 2.91 (73.9) 6.45 (164) 6.57 (167) 5.33 (135) 5.49 (139)
25 mm 3.24 (82.3) —7.96 (202) — —
Swagelok
tube
adapter
3/8 in. 2.76 (70.1) ————
1/2 in. 2.98 (75.7) ————
3/4 in. 3.04 (77.2) ————
R
D
60 Series Outlet Valve
with Swagelok Tube
Fitting End Connections
Shown

A Swagelok Pre-Engineered Subsystem Fluid Distribution Header
11
FDH1 (1 in. Pipe Platform) Drain—C Dimension
End Connections
Drain Valve
No Valve 40G or 40
Series 60 Series 1 or 18
Series
P4T or P6T
Series
Type Size C, in. (mm)
Female NPT
1/4 in. 1.41 (35.8) 3.44 (87.4) 3.54 (89.9) 3.50 (88.9) 3.76 (95.5)
3/8 in. 0.50 (12.7) 3.87 (98.3) 4.07 (103) 4.37 (111) —
1/2 in. 0.86 (21.8) 5.07 (129) 4.65 (118) 4.95 (126) 4.83 (123)
3/4 in. 1.21 (30.7) —5.85 (149) — —
Fractional
Swagelok
tube fitting
1/4 in. 1.73 (43.9) 3.61 (91.7) 4.57 (116) 3.67 (93.2) 3.57 (90.7)
3/8 in. 1.25 (31.8) 3.88 (98.6) 4.00 (102) 3.41 (86.6) 3.49 (88.6)
1/2 in. 1.37 (34.8) 4.88 (124) 5.00 (127) 3.76 (95.5) 3.84 (97.5)
3/4 in. 1.40 (35.6) ————
1 in. 1.67 (42.4) ————
Metric
Swagelok
tube fitting
6 mm 2.01 (51.1) 3.83 (97.3) 4.61 (117) 3.71 (94.2) 3.61 (91.7)
10 mm 2.11 (53.6) 4.51 (115) 4.64 (118) 4.40 (112) 4.12 (105)
12 mm 1.40 (35.6) 5.96 (151) 6.08 (154) 5.19 (132) 5.00 (127)
25 mm 1.69 (42.9) ————
Swagelok
tube
adapter
1/4 in. 1.99 (50.5) ————
3/8 in. 1.20 (30.5) ————
1/2 in. 1.46 (37.1) ————
3/4 in. 1.59 (40.4) ————
1 in. 1.93 (49.0) ————
ASME class
150 flange
1/2 in. 2.74 (69.6) —6.36 (162) — —
1 in. 3.56 (90.4) —8.14 (207) — —
Plug — 0.50 (12.7) — — — —
Dimensions
Dimensions are for reference only and are subject to change.
C
No Drain Valve
with Swagelok
Tube Adapter
End Connection
Shown

A Swagelok Pre-Engineered Subsystem Fluid Distribution Header
12
1.25
(31.8) 0.63
(16.0)
0.41
(10.4)
2
mounting
holes,
0.41 (10.4)
dia
A
B
Mounting Brackets
Model
Dimensions, in. (mm)
A B
FDH1 3.94 (100) 3.13 (79.5)
FDH2 5.06 (126) 4.25 (108)
Outlet
Branch
Side
Number of
Outlets Per
Side
Number of
Mounting
Brackets
Valves on
one side
4 2
6 3
8 4
Valves on
two sides
2 1
3 2
4 2
5 2
6 3
7 3
8 4
FDH2 (2 in. Pipe Platform) Drain—C Dimension
End Connections
Drain Valve
No Valve 40 Series 60 Series 1 or 18
Series
P4T or P6T
Series
Type Size C, in. (mm)
Female NPT
3/8 in. 0.88 (22.4) 4.25 (108) 4.45 (113) 4.75 (121) —
1/2 in. 0.88 (22.4) 5.09 (129) 4.67 (119) 4.97 (126) 4.85 (123)
3/4 in. 0.88 (22.4) —5.52 (140) — —
1 in. 0.88 (22.4) —5.86 (149) — —
Fractional
Swagelok
tube fitting
3/8 in. 2.17 (55.1) 4.13 (105) 4.25 (108) 3.66 (90.3) 3.74 (95.0)
1/2 in. 1.62 (41.1) 5.13 (130) 5.25 (133) 4.01 (102) 4.09 (104)
3/4 in. 1.62 (41.1) 5.13 (130) 5.25 (133) 5.01 (127) —
1 in. 1.79 (45.5) —6.66 (169) — —
2 in. 3.19 (81.0) —12.3 (312) — —
Metric
Swagelok
tube fitting
10 mm 2.33 (59.2) 5.02 (128) 5.15 (131) 4.55 (116) 4.63 (118)
12 mm 2.56 (65.0) 6.10 (155) 6.22 (158) 4.98 (126) 5.14 (131)
25 mm 1.80 (45.7) —7.71 (196) — —
50 mm 3.19 (81.0) ————
Swagelok
tube
adapter
3/8 in. 1.45 (36.8) ————
1/2 in. 1.71 (43.4) ————
3/4 in. 1.77 (45.0) ————
1 in. 2.05 (52.1) ————
2 in. 3.51 (89.2) ————
ASME class
150 flange
1/2 in. 2.99 (75.9) —6.61 (168) — —
1 in. 3.68 (93.5) —8.23 (209) — —
2 in. 6.43 (163) —15.2 (386) — —
Plug — 0.88 (22.4) ————
Dimensions
Dimensions are for reference only and are subject to change.
C
No Drain Valve
with Swagelok
Tube Adapter
End Connection
Shown

A Swagelok Pre-Engineered Subsystem Fluid Distribution Header
13
Ordering Information
Build an FDH subsystem ordering number by combining the designators in the sequence shown below.
FDH1 (1 in. Pipe Platform)
FDH1 - A C -C 1 - C 1 - C 3 - 0
2 41 3 5 6 78 9
1Outlet Branch Sides
A = 1 side right
B = 1 side left
C = 2 sides 180° apart
D = 2 sides right/middle 90° apart
E = 2 sides left/middle 90° apart
2Number of Outlets
A = 4
B = 6
C = 8
D = 10 (2-side configurations only)
E = 12 (2-side configurations only)
F = 14 (2-side configurations only)
G = 16 (2-side configurations only)
3Inlet Connections
B = 3/8 in. female NPT
C = 1/2 in. female NPT
D = 3/4 in. female NPT➀
H = 1/2 in. Swagelok tube fitting
J = 3/4 in. Swagelok tube fitting
K = 1 in. Swagelok tube fitting➀
P = 12 mm Swagelok tube fitting
Q = 25 mm Swagelok tube fitting➀
S = 1/2 in. NPS ASME class 150
flange➀
T = 1 in. NPS ASME class 150
flange➀
W = 3/8 in. Swagelok tube adapter➁
X = 1/2 in. Swagelok tube adapter➁
Y = 3/4 in. Swagelok tube adapter➁
Z = 1 in. Swagelok tube adapter➁
➀Available with no inlet valve and 60 series valve only.
➁Available with no inlet valve only.
8Drain Valve
0 = None
1 = 40G (1/4 in. and 6 mm drain
connections) or 40 series (all other
drain connection sizes) ball valve
2 = 60 series ball valve
3 = 1 or 18 series needle valve
4 = P4T or P6T series plug valve
9Pressure Gauge
Gauges are dual scale with bar primary
and psig secondary scales.
0 = None
1 = 0 to 10 bar (0 to 145 psig)
2 = 0 to 40 bar (0 to 580 psig)
3 = 0 to 100 bar (0 to 1450 psig)
4 = 0 to 160 bar (0 to 2320 psig)
5 = 0 to 250 bar (0 to 3625 psig)
5Outlet Connections
A = 1/4 in. female NPT
B = 3/8 in. female NPT➀
C = 1/2 in. female NPT➂
F = 1/4 in. Swagelok tube fitting
G = 3/8 in. Swagelok tube fitting
H = 1/2 in. Swagelok tube fitting➂
M = 6 mm Swagelok tube fitting
N = 10 mm Swagelok tube fitting
P = 12 mm Swagelok tube fitting➂
V = 1/4 in. Swagelok tube adapter➁
W = 3/8 in. Swagelok tube adapter➁
X = 1/2 in. Swagelok tube adapter➁
➀Available with no outlet valve, 40G or 40 series
valve, 1 or 18 series valve, and 60 series valve only.
➁Available with no outlet valve only.
➁Not available with 40 series valves
4Inlet Valve
0 = None
1 = 40G (1/4 in. and 6 mm inlet
connections) or 40 series (all other
inlet connection sizes) ball valve
2 = 60 series ball valve
6Outlet Valve
0 = None
1 = 40G (1/4 in. and 6 mm outlet
connections) or 40 series (all other
outlet connection sizes) ball valve
2 = 60 series ball valve
3 = 1 or 18 series needle valve
4 = P4T or P6T series plug valve
7Drain Connection
A = 1/4 in. female NPT
B = 3/8 in. female NPT➀
C = 1/2 in. female NPT
D = 3/4 in. female NPT➁
F = 1/4 in. Swagelok tube fitting
G = 3/8 in. Swagelok tube fitting
H = 1/2 in. Swagelok tube fitting
J = 3/4 in. Swagelok tube fitting➂
K = 1 in. Swagelok tube fitting➂
M = 6 mm Swagelok tube fitting
N = 10 mm Swagelok tube fitting
P = 12 mm Swagelok tube fitting
Q = 25 mm Swagelok tube fitting➂
S = 1/2 in. NPS ASME class 150
flange➁
T = 1 in. NPS ASME class 150
flange➁
V = 1/4 in. Swagelok tube adapter➂
W = 3/8 in. Swagelok tube adapter➂
X = 1/2 in. Swagelok tube adapter➂
Y = 3/4 in. Swagelok tube adapter➂
Z = 1 in. Swagelok tube adapter➂
ZZ = Plug
➀Available with no drain valve, 40G or 40 series
valve, 1 or 18 series valve, and 60 series valve only.
➁Available with no drain valve and 60 series valve
only.
➂Available with no drain valve only.

A Swagelok Pre-Engineered Subsystem Fluid Distribution Header
14
1Outlet Branch Sides
A = 1 side right
B = 1 side left
C = 2 sides 180° apart
D = 2 sides right/middle 90° apart
E = 2 sides left/middle 90° apart
2Number of Outlets
A = 4
B = 6
C = 8
D = 10 (2-side configurations only)
E = 12 (2-side configurations only)
F = 14 (2-side configurations only)
G = 16 (2-side configurations only)
8Drain Valve
0 = None
1 = 40 series ball valve
2 = 60 series ball valve
3 = 1 or 18 series needle valve
4 = P4T or P6T series plug valve
9Pressure Gauge
Gauges are dual scale with bar primary
and psig secondary scales.
0 = None
1 = 0 to 10 bar (0 to 145 psig)
2 = 0 to 40 bar (0 to 580 psig)
3 = 0 to 100 bar (0 to 1450 psig)
4Inlet Valve
0 = None
1 = 40 series ball valve
2 = 60 series ball valve
6Outlet Valve
0 = None
1 = 40 series ball valve
2 = 60 series ball valve
3 = 1 or 18 series needle valve
4 = P4T or P6T series plug valve
Ordering Information
Build an FDH subsystem ordering number by combining the designators in the sequence shown below.
FDH2 (2 in. Pipe Platform)
FDH2 - C G -T 0 - H 2 - H 3 - 0
2 41 3 5 6 78 9
3Inlet Connections
C = 1/2 in. female NPT
D = 3/4 in. female NPT➀
E = 1 in. female NPT➀
H = 1/2 in. Swagelok tube fitting
J = 3/4 in. Swagelok tube fitting
K = 1 in. Swagelok tube fitting➀
L = 2 in. Swagelok tube fitting➀
Q = 25 mm Swagelok tube fitting➀
R = 50 mm Swagelok tube fitting➁
S = 1/2 in. NPS ASME class 150
flange➀
T = 1 in. NPS ASME class 150
flange➀
U = 2 in. NPS ASME class 150
flange➀
Y = 3/4 in. Swagelok tube adapter➁
Z = 1 in. Swagelok tube adapter➁
AA = 2 in. Swagelok tube adapter➁
➀Available with no inlet valve and 60 series valve only.
➁Available with no inlet valve only.
5Outlet Connections
B = 3/8 in. female NPT➀
C = 1/2 in. female NPT
D = 3/4 in. female NPT➁
E = 1 in. female NPT➁
G = 3/8 in. Swagelok tube fitting
H = 1/2 in. Swagelok tube fitting
J = 3/4 in. Swagelok tube fitting➀
K = 1 in. Swagelok tube fitting➁
N = 10 mm Swagelok tube fitting
P = 12 mm Swagelok tube fitting
Q = 25 mm Swagelok tube fitting➁
W = 3/8 in. Swagelok tube adapter➂
X = 1/2 in. Swagelok tube adapter➂
Y = 3/4 in. Swagelok tube adapter➂
➀Available with no outlet valve, 40G or 40 series
valve, 1 or 18 series valve, and 60 series valve only.
➁Available with no outlet valve and 60 series valve
only.
➂Available with no outlet valve only.
7Drain Connection
B = 3/8 in. female NPT➀
C = 1/2 in. female NPT
D = 3/4 in. female NPT➁
E = 1 in. female NPT➁
F = 1/4 in. Swagelok tube fitting
G = 3/8 in. Swagelok tube fitting
H = 1/2 in. Swagelok tube fitting
J = 3/4 in. Swagelok tube fitting➀
K = 1 in. Swagelok tube fitting➁
L = 2 in. Swagelok tube fitting➁
N = 10 mm Swagelok tube fitting
P = 12 mm Swagelok tube fitting
Q = 25 mm Swagelok tube fitting➁
R = 50 mm Swagelok tube fitting➂
S = 1/2 in. NPS ASME class 150
flange➁
T = 1 in. NPS ASME class 150
flange➁
U = 2 in. NPS ASME class 150
flange➁
W = 3/8 in. Swagelok tube adapter➂
X = 1/2 in. Swagelok tube adapter➂
Y = 3/4 in. Swagelok tube adapter➂
Z = 1 in. Swagelok tube adapter➂
AA = 2 in. Swagelok tube adapter➂
ZZ = Plug
➀Available with no drain valve, 40G or 40 series
valve, 1 or 18 series valve, and 60 series valve only.
➁Available with no drain valve and 60 series valve
only.
➂Available with no drain valve only.

A Swagelok Pre-Engineered Subsystem Fluid Distribution Header
15
Swagelok Custom Solutions
Although a wide variety of valves and ttings are available as standard,
there may be those applications which require different components
or congurations.
If a custom solution is required, Swagelok welcomes
these requests.
Nonstandard assemblies may include:
• Customized port spacing
• Other Swagelok products
• Different manifold lengths.
Regulatory Compliance
Europe
• Pressure Equipment Directive (PED) 2014/68/EU
• Atmospheres Explosive Directive (ATEX) 2014/34/EU
• Restriction of Hazardous Substances Directive (RoHS) 2011/65/EU
Americas
• Hazardous location electrical approval (CSA/UL)
• CRN registered in Canada (individual components of assembly)
Contact your authorized Swagelok representative for specic assembly compliance approvals
and certications available from the manufacturer.

Swagelok—TM Swagelok Company
© 2011-2021 Swagelok Company, January 2021, RevE, MS-02-358
Safe Product Selection
When selecting a product, the total system design must
be considered to ensure safe, trouble-free performance.
Function, material compatibility, adequate ratings,
proper installation, operation, and maintenance are the
responsibilities of the system designer and user.
•WARNING
Do not mix/interchange Swagelok products or
components not governed by industrial design
standards, including Swagelok tube fitting end
connections, with those of other manufacturers.
Warranty Information
Swagelok products are backed by The Swagelok Limited
Lifetime Warranty. For a copy, visit swagelok.com or contact
your authorized Swagelok representative.
This manual suits for next models
1
Table of contents
Popular Lawn And Garden Equipment manuals by other brands

Toro
Toro Power Shovel 39909 Operator's manual

ALZA
ALZA Ferrida SC4018 Translation of the original instructions for use

Gardena
Gardena 4066 Operator's manual

EINHELL
EINHELL 34.205.05 Original operating instructions

Clarke
Clarke CDT300 Operating & maintenance instructions

Chalet-Jardin
Chalet-Jardin Couv'Terrasse E-Store Assembly instructions

NATURE'S INSTRUMENTS
NATURE'S INSTRUMENTS NI-PG-301-01 quick start guide

Brabantia
Brabantia Flameguard Instructions for use

Vitavia
Vitavia Curve 401 Assembly instructions

AmLed Technologies
AmLed Technologies SG series installation instructions

BUSH COMPANY
BUSH COMPANY 180 XT Max Install instructions

Asgard
Asgard ACCESS Assembly instructions