Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3698 REV 0 ■ 122822
EVOUM1KIT, EVOUM2KIT
Evolutions Utility Meter Clamp-on Meter & Sensor Module
Installation Guide
Evolution
Model Numbers Feature Highlights
☐EVOUM1KIT Single Utility Meter - (1) Flow Meter-
ing Sensor cable included
☐EVOUM2KIT Compound Utility Meter - (2) Flow
metering Sensors cables included
• Flow Sensor Module
• 24V DC Power Supply 60"
• 2 Meter length Flow metering Sensor - (2) cables
included with EVOUM2KIT)
Location:
Compliance
Limited Lifetime - to the original end
purchaser in consumer/residential
installations.
10 Years - for commercial/industrial
installations. Refer to
www.symmons.com/warranty for
complete warranty information.
Warranty
Symmons Evolution EVOUM1KIT Includes flow sensor module, 24 V DC power supply, 2 Meter Remote Magnetic Field
Sensor. 10 Year Commercial Warranty. FCC rules compliant.
Symmons Evolution EVOUM2KIT Includes flow sensor module, 24 V DC power supply, (QTY 2) 2-Meter Remote Mag-
netic Field Sensor. 10 Year Commercial Warranty. FCC rules compliant.
Architectural/ Engineering Specification
Repair Parts
EVOUM1KIT EVOUM2KIT
• IC: 24889-WW08189
• FCC ID: 2ASQP-WW08189
This device complies with part 15 of the FCC Rules.
☐EVOAPWR24 Replacement Power Supply
24VDC
☐EVOUMS-2M Replacement Flow Metering
Sensor, 2 Meter
☐EVOUMS-7M Optional Flow Metering
Sensor, 7 Meter
EVOUNS-7M not included in KIT - Please order on
separate line if needed.
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3698 REV 0 ■ 122822
EVOUM1KIT, EVOUM2KIT
Dimensions
A
C
D
E
RJ45 TO MOLEX
12 PIN
B
1-11/16”
60”
Power Supply
24C DC
Power Jack
2 Meters 1-7/8”
11/16”
Flow Metering Sensor
Evolution Sensor
Module
Measurement
A1-7/16"
B1-5/8"
C5"
D3-7/8"
E6-1/2"
X 4
X 12
Mounting Hardware
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3698 REV 0 ■ 122822
EVOUM1KIT, EVOUM2KIT
A. Locate Gateway, Power
Adapter, (1x) Thin Antenna,
(2x) Wide Antennas
B. Connect Antennas and Pow-
er Adapter to the back of
the Gateway
Install Gateway
1. Location
1. Connect Gateway Hardware
Mechanical Room Admin. Oce Front Desk
Find a central location for the Gateway. Location should be a secure area not enclosed
in metal. Recommended locations include:
Note: After plugging the Gateway power adapter into an outlet, it could take a few minutes to boot up.
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3698 REV 0 ■ 122822
EVOUM1KIT, EVOUM2KIT
Customer App Setup
1. Create and Configure Customer Property
2. Create Customer account & send Email Invitation
3. Customer Logs into water.symmons.com
4. Download the Evolution App for iOS or Android and Sign-In
5. Scan Gateway QR Code and Complete In-app Steps
Scan the Provided QR Code with your
Smartphone or camera to download the
evolution App.
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3698 REV 0 ■ 122822
EVOUM1KIT, EVOUM2KIT
Single Water Meter
Compound Water Meter
A
A
B
D
D
B
C
C
E
E
Single Utility Meter Installation
1. Sensor and Module Installation
A. Plug in Flow Metering Sensor Cable to one of the two Male RJ45 on the Evolu-
tion Sensor Module
B. Place the sensor cable chip flat side facing the water meter
C. Secure sensor cable chip on water meter with Provided zip ties
D. Secure Evolution Sensor Module in desired location using provided mounting
hardware. (Screws, Anchors or Zip-ties)
EConnect the Power Supply Jack into the Evolution Sensor Module then plug
the provided Power Supply into a 110VAC Outlet
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3698 REV 0 ■ 122822
EVOUM1KIT, EVOUM2KIT
Single Water Meter
Compound Water Meter
A
A
B
D
D
B
C
C
E
E
1. Sensor and Module Installation
A. Plug in both flow meter cable to the Male RJ45 on sensor module
B. Place the sensor cable chip flat side facing the water meter repeat for sec-
ond water meter. The two Sensors must be placed on the farthest point on
the water meter from one another
C. Secure both sensor cable chip on water meter with Provided zip ties
D. Secure sensor Module in desired location using provide mounting. (Screws &
Anchors or Zip-ties)
E. Connect the power supply Jack into the Evolution Sensor Module then plug
the provided power supply into a 110VAC Outlet
Compound Utility Meter Installation
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3698 REV 0 ■ 122822
EVOUM1KIT, EVOUM2KIT
Single Utility Meter Installation
2. Sensor Module App Setup
3. Meter Reading
A. Scan Sensor Module QR Code
B. Complete App Steps
A. Take Meter Reading from a Photo
B. Read digits / dial. Estimate last
digit between "hash" marks
C. Check Meter units (ex. Cubic
Feet or Gal)
D. Avoid register voids and rollovers
B
A
C

This manual suits for next models

1

Popular Measuring Instrument manuals by other brands

Laser Atlanta SpeedLaser user manual

Laser Atlanta

Laser Atlanta SpeedLaser user manual

GEONiN DM-100 manual

GEONiN

GEONiN DM-100 manual

Drawell DW-DI1500 user manual

Drawell

Drawell DW-DI1500 user manual

Dräger Interlock 7000 Instructions for use

Dräger

Dräger Interlock 7000 Instructions for use

MyTek DDD-603 Reference manual

MyTek

MyTek DDD-603 Reference manual

Raycus RFL-C Series user guide

Raycus

Raycus RFL-C Series user guide

Ascon tecnologic TRH514 user manual

Ascon tecnologic

Ascon tecnologic TRH514 user manual

Suin SA2200 user guide

Suin

Suin SA2200 user guide

Erchonia FX 635 Operation & maintenance manual

Erchonia

Erchonia FX 635 Operation & maintenance manual

Concoa Altos 2 Installation and operating instructions

Concoa

Concoa Altos 2 Installation and operating instructions

Dakota Digital MVX-2004 manual

Dakota Digital

Dakota Digital MVX-2004 manual

MRC CLRM-200 Operation manual

MRC

MRC CLRM-200 Operation manual

PASCO OS-8526A instruction sheet

PASCO

PASCO OS-8526A instruction sheet

Solinst 101 P7 operating instructions

Solinst

Solinst 101 P7 operating instructions

Fluke OptiView FiberInspector OPV-FT600 installation guide

Fluke

Fluke OptiView FiberInspector OPV-FT600 installation guide

Mindray BS-200 Operation manual

Mindray

Mindray BS-200 Operation manual

Bartington MS3 Operation manual

Bartington

Bartington MS3 Operation manual

Sensepeek SP10 user guide

Sensepeek

Sensepeek SP10 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.