Systec & Solutions PILOT 217 User manual

PILOT 217 MONITOR/THIN CLIENT
INDUSTRIAL MONITOR/THIN CLIENT
INSTRUCTIONS FOR USE
PILOT
Read the instructions prior to performing any task!

©2013
Systec & Solutions GmbH
Emmy-Noether-Straße 17
D–76131 Karlsruhe
Telephone: 0721 6644 400
Fax: 0721 6644 444
email: [email protected]
Internet: www.systec-solutions.com
PILOT, 1, en_US, 19.03.2014
PILOT 217 monitor/thin client - Industrial monitor/thin client
2

Table of contents
1 General information................................................................................... 5
1.1 Information on the user guide........................................................ 5
1.2 Copyright notice................................................................................... 5
2 Safety................................................................................................................. 7
2.1 Designated use..................................................................................... 7
2.2 Safety notices........................................................................................ 7
2.3 Important safety notes....................................................................... 8
3 Product description................................................................................. 11
3.1 Overview............................................................................................... 11
3.2 Type plate............................................................................................. 12
3.3 Technical data for the device........................................................ 13
3.4 Dimensions.......................................................................................... 15
3.5 External connectors.......................................................................... 17
3.5.1 Overview of external connections........................................... 17
3.5.2 Description of the external connections............................... 17
3.6 Conformity........................................................................................... 20
4 Starting up................................................................................................... 21
4.1 Unpacking the device...................................................................... 21
4.2 Setting up the device....................................................................... 21
4.3 Mounting the device........................................................................ 22
5 Operation...................................................................................................... 25
5.1 Switching the device on.................................................................. 25
5.2 Switching the device off................................................................. 25
5.3 Operating the touchscreen............................................................ 25
5.4 Cleaning the device.......................................................................... 26
5.5 Using the optional USB connection............................................ 29
5.6 Setting up the WLAN (optional) .................................................. 29
6 Repairs........................................................................................................... 31
7 Storage........................................................................................................... 33
7.1 Unmounting the device.................................................................. 33
7.2 Storing the device............................................................................. 35
8 Packaging and transport...................................................................... 37
8.1 Packaging the device....................................................................... 37
8.2 Transporting the device.................................................................. 37
9 Disposal......................................................................................................... 39
10 Site information......................................................................................... 41
Table of contents
PILOT 217 monitor/thin client - Industrial monitor/thin client
3

Table of contents
PILOT 217 monitor/thin client - Industrial monitor/thin client
4

1 General information
1.1 Information on the user guide
This original user guide is an integral part of the PILOT 217 monitor/
thin client and provides you with information on the set-up, use,
storage and disposal of the device.
Before beginning any work, read the user guide and always keep it in
an accessible place.
This user guide is aimed solely at authorized specialists. None of the
content of this user guide may be put to practice by anyone other than
trained specialists.
Our user guides are updated regularly. Please send us your suggested
improvements and other hints by e‑mail, phone or fax. This will help us
to ensure that our documentation is as intelligible and user-friendly as
possible.
You will find our contact information on the inside of the front cover or
under “Site information”.
Ä
Chapter 10 “Site information” on page 41
1.2 Copyright notice
This user guide is protected by copyright.
Other than for internal purposes, making this user guide available to
third parties, duplicating it in any form, in whole or in part, and utiliza-
tion or distribution of its contents are permitted only with the written
permission of the manufacturer.
Any violation of this requirement will render you liable for damages.
The right to make further claims is reserved.
General information
Copyright notice
PILOT 217 monitor/thin client - Industrial monitor/thin client
5

General information
Copyright notice
PILOT 217 monitor/thin client - Industrial monitor/thin client
6

2 Safety
2.1 Designated use
PILOT 217 monitor/thin client is an HMI PC system. PILOT 217 monitor/
thin client is used to implement control and operating concepts and to
display and manipulate information in industrial and commercial envi-
ronments.
It is nonetheless possible for improper use to introduce hazards. For
correct operation and safe use it is therefore important to comply with
the information and instructions in this document.
Have the following work carried out only by professionals:
nInstallation
nDeinstallation
nWiring
nImplementing
Have the following work carried out only by Systec & Solutions
GmbH :
nRepairs
nServicing
nMaintenance
nModifications
The device may not be used in the following areas:
nareas subject to explosion hazards
nareas subjected to harmful radiation
nareas and applications that are subject to vibration and impacts
nfor carrying out safety functions such as
– air traffic control / flight control systems
– monitoring / controlling nuclear reactions
– monitoring / controlling mass transportation facilities
– monitoring / controlling medical systems
– monitoring / controlling weapons systems
Contravening these instructions voids all warranties and manufac-
turer’s responsibilities.
2.2 Safety notices
Please read these instructions attentively right through. It constitutes a
part of the device it describes and must be held available at all times.
Use the device only in accordance with its designated use (see
Ä
Chapter 2.1 “Designated use” on page 7).
For your own safety, always comply with the following safety instruc-
tions.
Warnings signal safety-related information.
Safety
Safety notices
PILOT 217 monitor/thin client - Industrial monitor/thin client
7

You will find warnings within sequences of procedures prior to a step
that involves a hazard to people or material property.
Three levels of warnings appear depending on the seriousness of the
hazard:
DANGER!
This signals an unusually hazardous situation. Failure to
comply with these instructions will result in serious irre-
versible injuries or death.
WARNING!
This signals an unusually hazardous situation. Failure to
comply with these instructions may result in serious irre-
versible or fatal injuries.
CAUTION!
This signals a hazardous situation. Failure to comply with
these instructions may result in minor or moderate inju-
ries.
NOTICE!
This signals a hazard for material property. Failure to
comply with these instructions may cause material
damage.
This signals useful hints within a series of work processes.
2.3 Important safety notes
WARNING!
Risk of injury from electric shock!
Assembling and connecting plug connectors while
voltage is connected may lead to life-threatening injuries.
– All work on the device must be carried out when the
supply line is free of voltage.
– Never plug in or unplug the power supply plug when
live with voltage.
– The supply cable must not be supplied with voltage
until assembly has completely finished.
Safety
Important safety notes
PILOT 217 monitor/thin client - Industrial monitor/thin client
8

WARNING!
Danger of injury from hot surfaces.
Power transmission and regulatory components become
hot in operation and may lead to injuries.
– Allow these components to cool down before you
begin dismounting the device.
WARNING!
Danger of injury due to excessive load.
Working on heavy equipment may lead to serious injuries.
– Always have two people when working with heavy
equipment.
DANGER!
Electric shock hazard if the device is connected to the
mains supply incorrectly.
Connecting the device incorrectly to the mains supply
may expose people to injuries from electric shocks.
– Before connecting up the device always disconnect
the line from the power supply.
– Before connecting up always check that the lines are
at zero voltage.
NOTICE!
This total discharge protection may result in data
being lost.
Total discharge protection is activated when the charge
capacity reaches a critical level (ca. 3%). The total dis-
charge protection facility powers the device down, which
may cause data to be lost.
– Save your data regularly.
– Check the charge capacity regularly.
– Don’t allow it to drop below 5%.
Safety
Important safety notes
PILOT 217 monitor/thin client - Industrial monitor/thin client
9

Safety
Important safety notes
PILOT 217 monitor/thin client - Industrial monitor/thin client
10

3 Product description
3.1 Overview
HMI systems from Systec & Solutions GmbH are user interfaces for man-
aging and observing ongoing production processes. All devices are
highly available units designed in stainless steel, particularly suited to
harsh conditions in the process industry and, in addition, they guar-
antee IP65 protection.
Fig. 1: PILOT 217 monitor/thin client
No. Designation Description
1 Display Used to display information.
2 Optional On/Off button Switches the device on and off.
Optional USB connection Used to connect a USB stick.
Fig. 2: Rear view of monitor
The OSD button on the back of the monitor is used to display informa-
tion and modify the monitor settings.
HMI system PILOT 217 monitor/thin
client
Device
OSD (on-screen display)
Product description
Overview
PILOT 217 monitor/thin client - Industrial monitor/thin client
11

The integrated AX3000 MODEL 80 Ultra-Thin-Client offers a user inter-
face for data processing purposes. The connection is via Ethernet.
Depending on the configuration, two USB interfaces are also provided
for additional peripherals.
nFor information about the interfaces, see
Ä
Chapter 3.3 “Technical
data for the device” on page 13).
nFor further information, see the manufacturer’s website
www.axel.com
Fig. 3: PILOT 217 monitor/thin client
No. Designation Description
1 Camera/Microphone Used to record images and sound.
2 Loudspeaker (behind the
display) Used to reproduce sounds.
3.2 Type plate
The product designation and identification will be found on the type
plate. This is always located on the rear of the device and contains the
following information:
Fig. 4: Position of type plate
Axel thin-client (optional)
Multimedia kit (optional)
Product description
Type plate
PILOT 217 monitor/thin client - Industrial monitor/thin client
12

6
7
1
2
3
5
4
Fig. 5: Type plate
No. Description
1 Product name
2 Serial number
3 Power supply and consumption, charge current
and battery capacity (only for devices with an inte-
grated battery)
4 CE mark
5 Manufacturer’s logo
6 QR code (S/N + product name)
7 Manufacturer’s address
3.3 Technical data for the device
System
Model WAVE 224
Variant Monitor
Housing material Stainless steel 1.4301
Surface glass-beaded, optionally sanded
IP protection factor IP65
Display
Type of display 17.3" LCD display with LED backlight (Sunlight Readable optional)
Display area 382.08 x 214.92 mm
Native (maximum) resolution 1600 x 900
Page ratio 16:9
Colors 262 thousand
Brightness 220 cd/m2
Contrast 500:1
Response time 8 ms
Product description
Technical data for the device
PILOT 217 monitor/thin client - Industrial monitor/thin client
13

Display
Horizontal frequency (KHz)
Vertical frequency (Hz)
30 —83 kHz
50 —76 Hz
Touchscreen (optional) mouse compatible, analog resistive or PCT (projected capacitive) multi-
touch with optical bonding
Interfaces
Standard interfaces 1 x VGA / 1 x DVI
Touchscreen (optional) 1 x USB for touch controller
VoIP hardware (optional) 1 x USB for camera, mikrophone and loudspeaker
Ultra-Thin-Client (optional) 2 x USB, 1 x Ethernet
All the installed USB components (VoIP hardware,
touchscreen, keyboard, WLAN, etc.) are connected to the
PILOT 217 monitor/thin client using only one connector (type
B).
Power supply / consumption
Extra-low voltage power supply 12 ‒24 V DC, 10 ‒5 A
Protection of supply lead (Extra-low
voltage DC) max. 10 A, the supply lead should be specified.
Low voltage power supply 100 ‒240 V AC, 50 ‒60 Hz, 2,0 ‒0,9 A
Product description
Technical data for the device
PILOT 217 monitor/thin client - Industrial monitor/thin client
14

Power supply / consumption
Protection of supply lead (Low voltage
AC) max. 16 A, the supply lead should be specified.
Mean power consumption in oper-
ating mode 20 W
Environmental conditions
Storage -20 °C ‒+60 °C
Operation 0 °C ‒+40 °C
Humidity 10 % ‒90 %; non condensing
Maße (in mm ohne Tastaturgelenk)
Width 445
Height 280
Depth 55
Weight
Net weight ca. 8 kg
3.4 Dimensions
446
280
215
382
Fig. 6: Dimensions of front of device
Product description
Dimensions
PILOT 217 monitor/thin client - Industrial monitor/thin client
15

280
190
402
445
100
130
Fig. 7: Dimensions of back of device
280
55
Fig. 8: Dimensions in side view
Product description
Dimensions
PILOT 217 monitor/thin client - Industrial monitor/thin client
16

3.5 External connectors
3.5.1 Overview of external connections
The following illustration shows the connectors that are located on the
back of the PILOT 217 monitor/thin client.
Fig. 9: Overview of the interfaces on the back (depending on the configura-
tion)
3.5.2 Description of the external connections
Your device will not incorporate all of the following connectors (see
Ä
Chapter 3.3 “Technical data for the device” on page 13).
= 9-pole Sub-D socket for connecting serial devices
Fig. 10: Serial connection (RS
‑
232)
= 24-pole DVI socket for connecting to the basic computer
Fig. 11: DVI socket with pinout
= 19-pole HDMI socket for connecting to the basic computer
Fig. 12: HDMI socket with pinout
Serial connection (RS‑232)
DVI port
HDMI port
Product description
External connectors > Description of the external connections
PILOT 217 monitor/thin client - Industrial monitor/thin client
17

= 15-pole HD-D "VGA" socket for connecting basic computer
Fig. 13: VGA socket with pinout
= 4-pole USB socket (type A) for connecting components:
nVoIP hardware components and/or
ntouchscreen and/or
nkeyboard
Fig. 14: USB socket with pinout
= 8-pole Ethernet socket for connecting to a network
Fig. 15: Ethernet socket with pinout
3.5.2.1 Power supply
NOTICE!
Risk of material damage if the device is connected to
an incorrect power supply.
Connecting the device to an incorrect power supply may
cause material damage.
– Check the power rating of your device.
VGA port
USB connection
Ethernet (RJ45)
Product description
External connectors > Description of the external connections
PILOT 217 monitor/thin client - Industrial monitor/thin client
18

Power is supplied via a 2-pole Phoenix socket of type DFK-PC /2-
GF-7,62. The corresponding plug carries the designation Phoenix Con-
tact PC 4/ 2-ST-7,62.
Fig. 16: 2-pole Phoenix Contact socket for the power supply
Pin Designation Significance
1-Ground (GND) 0V
2 + Power supply +
Power is supplied via a 3-pole Phoenix socket of type DFK-PC /3-
GF-7,62. The corresponding plug carries the designation Phoenix Con-
tact PC 4/ 3-ST-7,62.
Fig. 17: 3-pole Phoenix Contact socket for the power supply
Pin Designation Significance
1 PE Surge protectors
2 L Phase
3 N Neutral conductor
Power supply in the extra low voltage
range (12‑24V DC)
Power supply in the low-voltage
range (100 – 240 V AC, 50 – 60 Hz)
Product description
External connectors > Description of the external connections
PILOT 217 monitor/thin client - Industrial monitor/thin client
19

3.6 Conformity
Systec & Solutions GmbH
PILOT 215-217-218-219-221
Industrial PC/Monitor
nPURPOSE
For the above product, in the version with a 12 – 24 V DC power
supply, we hereby confirm that it complies with the essential pro-
tection requirements of the EMC Directive 2004/108/EC (electro-
magnetic compatibility).
The above product, in the version with a 100 – 240 V AC power
supply, also complies with the requirements of the EC Low Voltage
Directive 2006/95/EC.
nSCOPE
The product listed above fulfills the requirements of the EMC Direc-
tive 2004/108/EC on the basis of the following standards:
– EN 55022:1998 + A1:2000 + A2:2003 Class A
– EN 55024:1998
– EN 61000-6-2:2005
– EN 61000-4-2:2007
The product listed above fulfills the requirements of the Directive
2006/95/EC on the basis of the following standard:
– EN 60950-1:2006
nCERTIFICATE
Compliance with protection requirements was established with the
housing closed on all sides.
Systec & Solutions GmbH
Emmy-Noether-Straße 17
D–76131 Karlsruhe
Germany
Phone +49 721 6634 400
Fax +49 721 6634 444
www.systec-solutions.com
Karlsruhe, July 1, 2013
Karl G. Linder
CEO
Declaration of Conformity
Product description
Conformity
PILOT 217 monitor/thin client - Industrial monitor/thin client
20
Table of contents
Other Systec & Solutions Monitor manuals