System Q LAM042 User manual

42W ENERGY
SAVER FLOODLIGHTS
LAM042
Instructions

B
D
A
C

F
E
LUX
Time
Clamping Screws
(vertical adjustment)
OFF

SECTION ONE
GENERAL INFORMATION
This floodlight features an integral daylight sensing photocell which will automatically switch the
light on at dusk and off at dawn or at a time set by the user.
Unit is for outdoor use only. Unit must be mounted as a fixed luminaire, and is not suitable for
portable use.
PARTS INCLUDED
- Low Energy Floodlight c/w Dusk/Dawn sensor.
- Instruction manual. Please keep safe for future reference.
- Accessory Pack including screws and wall plugs.
- 4 pin low energy lamp.
TOOLS & PARTS NEEDED
- 3 flexible core cable (1.0mm² or 1.5mm²).
- Electric/hand-held drill & bits.
- Terminal or Electricians screwdriver.
- Wire cutters.
Do not attempt to install during wet weather, if you are suffering from nausea or dizzy spells or
on medication with similar side effects.
NO USER SERVICEABLE PARTS INSIDE.
SECTION TWO
INSTALLATION
After choosing a suitable location (see previous section) install the unit as follows:
The unit is suitable for connection to a 240 V ac 50Hz electricity supply. It is suggested that
3-core round flexible cable of 1mm² or 1.5mm² gauge is used. An internal switch should be
installed to switch the power to the unit ON & OFF. This allows the unit to be easily switched off
when not required or for maintenance purposes.
This unit uses an integral wall fixing plate, detach the wall fixing plate by unscrewing the fixing
screw on the underside of the wall plate (diagram A).
The floodlight is located onto the wall plate by a lug which is inserted into the rectangular recess
in the top of the wall plate. To remove wall plate from floodlight, slide out the bottom edge and
lift upwards, the lug will lift out of the recess in the wall plate separate from the floodlight.
IT IS RECOMMENDED THAT THE LOW ENERGY BULB IS FITTED AND THE FRONT COVER IS
SECURED BEFORE FITTING THE FLOODLIGHT TO THE WALL
*** IMPORTANT ***
Switch off the electricity at the fuse box by removing the relevant fuse or switching
off the circuit breaker before proceeding with the installation.

To fit the bulb, release but do not remove the two screws on the rear of the floodlight (diagram B).
Release the clips shown on diagram B at either side of the housing, the floodlight front cover
will open and rotate down but will not separate from the main floodlight body.
Remove the bulb from its packaging and fit into the lampholder. Ensure the bulb is fully secured
into the lampholder and the support bracket is located around the bulb.
Close the front cover, ensure the clips are fully located (there will be an audible "click") and fully
tighten the two securing screws on the rear of the unit.
Mark the position of the wall fixing holes. Ensure the wall plate is correctly positioned. Note the
"UP" ident on the inside of the wall plate (diagram C).
Drill the holes, insert the wall plate into the holes.
PIERCE AND PASS THE CABLE THROUGH THE GROMMET BEFORE SECURING THE WALL
PLATE TO THE WALL.
It is recommended that the grommet is pierced with a screwdriver to ensure a better seal.
Remove the cable clamp, feed the incoming cable under the cable clamp and secure. Do not
overtighten the cable clamp as it could damage the cable insulation.
Fix the wall plate to the wall (diagram C).
The unit is supplied with a hanging attachment (tether) to aid installation.
If it is not required, simply remove from the unit and discard.
Ensure the tether is securely fixed into the slot before releasing the weight of the unit.
The unit can now be suspended below the wall bracket (fig D).
CONNECTION
Connect the cable to the terminal block on the unit as follows (see diagram E):
NEUTRAL (Blue) N
EARTH (Green/Yellow)
LIVE (Brown) L
Ensure Connections are secure.
Ensure any extra cable and the tether is tucked into the space in the wiring box.
Fit the floodlight to the bracket by inserting the lug in the floodlight into the recess at the top
of the wall plate and locating the floodlight securely over the wall plate.
Fit and fully secure the locating screw (diagram A).
This floodlight uses a universal joint, it can be directed to suit your installation by rotating the
floodlight left to right and up or down. Secure in desired vertical position by use of the clamping
screws on either side of the floodlight joint (see diagram E).
Installation is complete!

SECTION THREE
OPERATION AND TESTING
SETTING UP FOR AUTOMATIC OPERATION
The adjustment controls on the unit (diagram F) should be set as follows.
The TIME control determines how long the lamp remains illuminated after activation.
There are 5 designated “time on” settings O (or off), 2, 4, 6, 8 hours and dusk/dawn.
These settings allow the lamp to illuminate for the designated time on period after darkness falls
and the unit is activated.
If you require the lamp to be illuminated all night, set the time control fully clockwise to “Dusk/
Dawn”. The unit will then remain on until the following morning when the lux level increases
enough to switch the unit off during the day.
The DUSK (LUX) control determines the level of darkness required for the unit to start operating.
The setting is best achieved by the procedure below:
Set the DUSK control knob fully anti-clockwise and the Time control to the required
number of hours or dusk/dawn (do not leave in the O (off, fully anti-clockwise) position).
Wait until darkness falls.
When the ambient light level reaches the level of darkness at which you wish the lamp to
become operative (ie. At dusk), SLOWLY rotate the control in a clockwise direction until a point
is reached where the lamp illuminates. Leave the control set at this point.
At this position, the unit should become operative at approximately the same level of darkness
each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie.
when it is quite light), adjust the control slightly anti-clockwise. If the unit starts to operate too
late (ie. only when it is very dark), adjust the control slightly clockwise.
Continue to adjust until the unit operates as desired.
MANUAL OVERRIDE MODE
The light can be switched on for longer time periods by use of the Manual Override Mode.
This can be activated at night by using the internal wall switch or circuit breaker supplying the
unit.
Please note:- The unit CANNOT be operated in Manual Override Mode during daylight hours. If
you want to test this function when installing the unit, this test must be carried out after dusk
when the unit has become operational.
To activate Manual Override Mode:-
Switch the internal wall switch/circuit breaker once (off/on) within 1 second.
The unit will now illuminate continuously until dawn or until it is switched back into Auto Mode.
To de-activate Manual Override Mode (ie. switch the unit back into Auto Mode):-
Switch the internal wall switch/circuit breaker once (off/on) within one second. The unit will
return to its Auto mode and will operate as set up during the walk test period.
To de-activate Manual Override Mode (ie. switch the unit back into Auto Mode):-
Switch the internal wall switch/circuit breaker once (off/on) within one second. The unit will
return to its Auto mode and will operate as set up initially.

SECTION FIVE
NO USER SERVICEABLE PARTS INSIDE
TROUBLESHOOTING GUIDE
PROBLEM
The oodlight will not
operate at night.
Unit activates during the
daytime.
SOLUTION
The level of ambient light in the area may be too bright to
allow operation at the current DUSK setting. During the hours
of darkness, adjust the DUSK control slowly clockwise until the
lamp illuminates. Refer to previous section for more details.
Adjust the lux setting anti-clockwise to lower the level of
ambient light required for activation.
SECTION FOUR
TECHNICAL SPECIFICATIONS
Power Supply
Lamp Type
Time On
Lux Level Adjustment
Environmental Protection
EC Directives
240V AC ~ 50Hz
240V 42W 4 pin (GX24q-4) Low Energy lamp
2, 4, 6, 8 hours from dusk or dusk/dawn
Day & night or night only operation
IP44 (suitable for outdoor use)
Conforms to 73/23/EEC, 89/336/EEC
Table of contents
Popular Floodlight manuals by other brands

Timeguard
Timeguard LED100PIRBE Installation & operating instructions

afx light
afx light COMBO-LED 15-1872 instruction manual

Heath Zenith
Heath Zenith Secure Home UT-9260-BZ user guide

M-Elec
M-Elec ML-MRFLD-15-W manual

Solar Goes Green
Solar Goes Green SGG-FL3W-Extreme manual

Heath Zenith
Heath Zenith Energy Star SL-5666 installation instructions