manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TankScan
  6. •
  7. Measuring Instrument
  8. •
  9. TankScan TSM1000 Manual

TankScan TSM1000 Manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

www.tankscan.com
TSM1000 Tank Monitor with
Remote Battery Setup Instructions
Determine probe wire length using Probe Length Calculation diagram
then measure probe wire length from wire exit point in housing base until
calculated length is reached. Make a mark at this point and trim excess wire.
Cut Probe Wire to Length
4
3
Take Tank Measurement
2
1
Remove any equipment from tank port to be used by monitor. TSM monitor
can be connected directly to tanks with a 1.5” or 2” NPT threaded opening.
Measure the total tank height from inside bottom of tank to top of tank port
and report this measurement to TankScan Technical Support.
Total Height:
Connect Battery and Test Connection
For tank farm systems with a gateway, set up gateway before connecting
battery. Select a spot near tank you are installing.
To power up TankScan Monitor, unscrew the screws on the cover of remote
battery pack housing and connect battery connector to remote battery pack
housing connector. Reinstall cover and tighten screws. Connect female
threaded connector of battery cable to connector on remote battery pack
housing. Connect male threaded connector of battery cable to connector on
monitor housing.
Monitor will wake up and sound 1 beep. Then a second single beep will
follow, with a third single beep for data transmission. 3 single beeps indicate
a good connection was made. If more than 3 single beeps were heard,
contact TankScan Technical Support. If 3 single beeps are confirmed, then
proceed as follows.
Disconnect battery cable from remote battery pack and mount remote
battery pack to the tank at a temporary location using magnetic back.
4
Measure from
probe wire exit
point
4
Using 2” Thread:
Probe Length
= A - 2.50
Using 1.5” Thread:
Probe Length
= A - 2
A= Total interior height of the tank
including any riser height.
Probe Length
Calculation
Total
Height
A
Fluid
Level
3
1
5
Attach Accessories
6
Float Assembly - Slide onto probe wire if included with monitor.
Probe Wire Weight - Slide onto probe wire such that wire extends and is
flush with end of weight. Tighten weight clamp using provided hex wrench.
Explosion Hazard. Use only ATEK provided battery pack.
5
6
Float Assembly
Probe Wire
Weight
ATEK Access Technologies
10025 Valley View Road, Ste. 190
Eden Prairie, MN 55344 U.S.A.
PH: 1.800.523.6996
FAX: 1.800.589.3705
+1.218.829.9797
www.atekaccess.com
©2021 ATEK Access Technologies, LLC. All Rights Reserved. TankScan images and marketing materials are protected by various patents, copyrights
and/or trademarks. ATEK assumes no responsibility for any errors which may appear in this document, reserves the right to change devices or
specifications detailed herein at any time without notice, and does not make any commitment to update the information contained herein. No licenses to
patents or other intellectual property of ATEK are granted by the Company in connection with the sale of TankScan products, expressly or by implication.
223-0191-000 Rev. B 6/21
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
12
11
7For monitors installed on risers greater than 3” long, a PWG is required to
prevent probe wire from contacting riser. Refer to TankScan Probe Wire
Guard Installation Guide or tankscan.com/support.
NOTE: Return to these setup instructions to complete monitor
installation aer Probe Wire Guard installation.
If PWG is required but not provided as a field-installable kit, contact
TankScan Technical Support to order PWG Field Install Kit before proceeding.
If PWG is not required, then proceed to step 8.
Determine if Probe Wire Guard (PWG) is Needed
8
9
Lower probe wire with weight gently through tank port into tank. Position
monitor over tank port and hand tighten until secure.
Seal pipe threads of monitor using product appropriate for this application
prior to tightening into tank port. Remote battery pack cable can be removed
for ease of installation then plugged in once monitor is fully mounted.
Connect battery cable to remote battery pack and mount remote battery
pack at base of tank such that the battery cable is coming out bottom of
remote battery pack housing. If mounting remote battery pack to a plastic
tank, apply hook and loop fastener strips to edges of magnet face of remote
battery pack.
Mount TSM Monitor to Tank
10
Test monitor by swiping magnet end of supplied screwdriver along cover’s
rim above triangle indicator on housing base until a beep is heard. Monitor
will take a level reading and then report to ATEK Intelligence Platform (AIP).
A second single beep will occur once monitor has finished reporting its
level measurement.
If monitor has been pre-provisioned, then confirm reading is correct on AIP
or optionally call TankScan Technical Support, to finish or confirm reading.
NOTE: Step 12 must be completed for monitor to function properly.
Test Setup
TankScan Technical Support
877-847-7226
CCT@TankScan.com
7
TSM1000 Tank Monitor with
Remote Battery Setup Instructions
10
12
Cellular
Contains FCC ID: MCQ-XB3M1
Contains IC: 1846A-XB3M1
Rf
Contains FCC ID: MCQ-XBEE3
Contains IC: MCQ-XBEE3
Operation is subject to the following
2 conditions:
1. This device may not cause harmful
interference and
2. This device must accept any interference
received, including interference that may
cause undesirable operation.