TECHNICAL SPECIFICATIONS
Output Power 120 watt
Power bandwidth (THD <0.4%) Direct output: 20Hz – 20kHz
Transformer output: 50Hz – 20kHz
Frequency Response (±1.5dB) Direct output: 20Hz – 20kHz
Transformer output: 50Hz – 20kHz
THD + Noise (1kHx @ rated power) <0.2%
Output Regulation (no load to full load) <0.5dBu
Signal to Noise Ratio Line inputs: 78dB
(20Hz-20kHz @ rated power) telephone inputs: 78dB
Master level off: 98dB
Compressor: Attack time: < 1mSecond
Release time: > 1 second
Compression Ratio: 4 : 1
Threshold adjust range: 15dB
Input Impedance/Sensitivity mic inputs: 6kΩ/-77dBu (110µV)
line inputs: 15kΩ/-37dBU (14mV)
telephone inputs: 600Ω/-60dBu (775µV)
amplifier input: 10kΩ/+4dBu (1.2V)
stacking input: 20kΩ/-8dbU (300mV)
patch/return input: 10kΩ/-8dBu (300mV)
Output Impedance/Level preamp output & line output: 200Ω/+4dBu (1.2V)
record output: 200Ω/+4dBu (1.2V)
patch/send output: 50Ω/-8dBu (300mV)
Amplifier Output Impedance/Level 4Ω/22V
8Ω/31V
5.2Ω/25V
20.8Ω/50V
40.8Ω/70V
83.3Ω/100V
Dimensions (H X W X D) 93.5mm x 482mm x 364mm (3.68" x 19" x 14.33")
Weight 12kg (26.45 lbs)
TMA120
Part No. 6483 0687 ocs3324Sep00
A Member of the TGI plc Group of Companies
Tannoy Ltd., Professional Division, Coatbridge, ML5 4TF, Scotland
Tel: +44 (0)1236 420199 Fax: +44(0)1236 428230
e-mail: prosales@tannoy.com Internet site: http://www.tannoy.com
TGI North America, 335 Gage Avenue, Suite #1, Kitchener, Ontario, N2M 5E1, Canada
Tel: (519) 745 1158 Fax: (519) 745 2364
Tannoy Nederland b.v., Anthonetta Kuijlstraat 19, 3066 GS Rotterdam