TASSLOCK Combo V2.0 Installation and user guide

How to Activate Tasslock Combo V2.0
After Install Tasslock 3G GPS Wiring, Please first Insert Nano SIM card and Turn on the Switch
(Photo Below) Login Via IMEI. Your Password is Last 6 Digits of IMEI Number.
Please place Tasslock 3G GPS in Open Sky and Wait up to 5 Minutes for location.
Note:
1. Must Use Robi Sim card for Bangladesh. ( Other Country Other Sim cards)
2. Tasslock 3G GPS must not put near Iron or metal.
3. Tasslock Logo should be face up to Sky.
4. GPS SIM card must have some money and Internet Data.
After Location come, please Make Admin.
How to Make Admin: ( You can make up to 3 Admins)
Go to App and Click Command > SOS Number management
And carefully put your Admin Number > Click Ok.
You are all done. You are now ready to Use Tasslock 3G GPS.
SIM Tray
GPS Switch

GPS COMMAND LIST
3G GPS Command List
SL
Function
Format
Example
Device
response
Description
1
Set server
parameters
SERVER,mode,
domainName/IP
,port,0#
SERVER,1,gps.whats
gps.com,6801,0#
SERVER,0,47.75.111.
37,6801,0#
OK!
mode = 1 means set
with domain name
mode = 0 means set
with ip address
2
Set APN
APN,
[apnname]#
APN,INTERNET#
OK! for the
newly-set
APN to take
effect, the
device will
reboot after
10s.
APN set by User.
3
Set GPS data
sending
interval
TIMER,[T1],[T
2]#
TIMER,10,10#
OK!
T1 ranges 5-18000
(seconds), upload
interval when ACC
ON, default is 10;
T2 ranges 5-18000
(seconds), upload
interval when ACC
OFF, default is 10;
4
Heartbeat
interval
setting
HBT,[T]#
HBT,3#
OK!
T ranges 1-300
(minutes), heartbeat
package upload
interval; default is 3;
5
SOS phone
number
setting
SOS,A,[phone1]
[,phone2][,phon
e3]#
SOS,A,13122012031,
13122012032,#
OK!SOS1:188
20786144,SO
S2:131563901
10,SOS3:
Add SOS phone
number.
6
Delete SOS
phone
number
FACTORY#
FACTORY#
OK!
The terminal
will restart
after 60s!
All admin number will
be deleted. Make a
new admin number
from app.
Now send sms:
SENALM,ON,2#
7
Engine Lock
Unlock
RELAY,[A]#
RELAY,0#
RELAY,1#
Restore fuel
supply:Succes
A=0/1;0 means
Unlock, 1 means

s!
Cut off the
fuel
supply:Succes
s!
Lock;default: 0.
8
Set Timezone
GMT,[A],[b],[C
]#
GMT,E,6,0#
OK!
A:E or W;"E" means
eastern time zone,
"W" means western
time
zone;default:E
B:0-12;time zone
default:8
C:0/15/30/45;half
time zone;default:0
9
Set
sensitivity of
SENSOR
SENLEVEL[,A]
#
SENLEVEL,3#
OK!
A: 1-5, sensitivity
level, corresponding
threshold is as follows
1: 100; 2: 300; 3: 800;
4: 1200; 5: 1600;
default is level 3
SENLEVEL#
SENLEVEL,3
Query the current
vibration alarm
sensitivity level of the
device
10
Set the
vibration
alarm
SENALM,[A][,
M]#
SENALM,ON,3#
OK!
A=ON/OFF, default:
ON;
M=0/1/2/3, alarm
ways:0 : only
GPRS, 1:
SMS+GPRS,
2:GPRS+SMS+PHON
E,3:GPRS+PHONE
default:3.
SENALM,OFF#
OK!
SENALM#
SENALM:ON
,1
Check the vibration
alarm setting
11
Set the power
cut-off alarm
POWERALM,[
A][,M]#
POWERALM,ON,1#
OK!
A=ON/OFF, default:
ON;
M=0/1/2/3, alarm
ways:0 : only
GPRS, 1:
SMS+GPRS,
2:GPRS+SMS+PHON
E,3:GPRS+PHONE
default:3.
POWERALM,OFF#
OK!
POWERALM#
POWERALM
:ON,1
Check the power cut-
off alarm setting
12
Set the low
BATALM, [A][,
BATALM,ON,1#
OK!
A=ON/OFF, default:

voltage alarm
M]#
BATALM,OFF#
OK!
OFF;
M=0/1/2/3, alarm
ways:0 : only
GPRS, 1:
SMS+GPRS,
2:GPRS+SMS+PHON
E,3:GPRS+PHONE
default:1.
BATALM#
BATALM:
ON, 1
Check the low voltage
alarm setting
13
Set the speed
alarm
SPEED,[A][,B][
,M]#
SPEED,ON,120,1#
OK!
A=ON/OFF, open or
close over speed
alarm, default:OFF
B=1-255(km/h),
speed limit,
default:100(km/h);
M=0/1/2, way of
alarm, 0 : GPRS only,
1: SMS+GPRS,
2:GPRS+SMS+PHON
E
default:1.
SPEED,OFF#
OK!
SPEED#
SPEED:OFF,1
20,1
Check the speed alarm
setting
14
Set the
moving
alarm
MOVING,[A][,
R][,M]#
MOVING,ON,200,1#
OK!
A=ON/OFF,
default:OFF;
R=100-1000, moving
radius, unit: meter,
default: 300;
M=0/1/2, way of
alarm, 0 : GPRS only,
1: SMS+GPRS,
2:GPRS+SMS+PHON
E
default:1.
MOVING,OFF
OK!
MOVING#
Moving
Switch:OFF;
Radius:300m;
Way of
alarm:1
Check the moving
alarm setting
15
ACC status
alarm
ACCALM,[A][,
B][,M]#
ACCALM,ON,1,1#
OK!
A=ON/OFF, open or
close acc alarm,
default:ON
B=1,ACC ON alarm;
B=2,ACC OFF alarm;
B=3,ACC ON and
ACC OFF alarm;
default:1;
M=0/1/2/3, alarm
ACCALM,OFF#
OK!

ways:0 : only
GPRS, 1:
SMS+GPRS,
2:GPRS+SMS+PHON
E,3:GPRS+PHONE
default:3.
ACCALM#
ACC:ON,2,1
Check the ACC alarm
setting
16
Set the circle
fence alarm
FENCE,[B],0,[
D],[E],[F],[X],[
M]#
FENCE,ON,0,23.1686
0,113.434669,4,,1#
OK!
FenceType:Ci
rcle, ON,
Latitude:N23.
111111,
Longitude:E1
13.123123,
radius:20000
m, in out:IN
or OUT, alarm
type:1.
circle area;
B=ON/OFF, open or
close fence alarm,
default:close;
D=the latitude of the
circle center;range:-
90 -90(degree);
E=the longitude of the
circle center;range:-
180 -180(degree);
F=1-9999, the fence
radius, unit:100
meters;
X=IN/OUT;IN:
alarming when get in
the fence, OUT:
alarming when get out
the fence, blank means
both alarming when
get in or get out the
fence, default: blank.
M=0/1/2, way of
alarm, 0 : GPRS only,
1: SMS+GPRS,
2:GPRS+SMS+PHON
E
default:1.
17
Set the
square fence
alarm
FENCE,[B],1,[
D],[E],[F],[G][,
X][,M]#
FENCE,ON,1,23.1111
1,113.12312,23.44232
,115.23224,,1#
OK!
FenceType:Sq
uare, ON,
Latitude1:N23
.111111,
Longitude1:E
113.123123,
Latitude2:N23
.442320,
Longitude2:E
115.232239,
in out:IN or
OUT, alarm
type:1.
square area
B=ON/OFF, open or
close fence alarm,
default:close;
D=the latitude of the
position 1;range:-
90 -90(degree);
E=the longitude of the
position 1;range:-
180 -180(degree);
F=the latitude of the
position 2;range:-
90 -90(degree);

G=the longitude of the
position 2;range:-
180 -180(degree);
X=IN/OUT;IN:
alarming when get in
the fence, OUT:
alarming when get out
the fence, blank means
both alarming when
get in or get out the
fence, default: blank.
M=0/1/2, way of
alarm, 0 : GPRS only,
1: SMS+GPRS,
2:GPRS+SMS+PHON
E
default:1.
18
Check fence
setting
FENCE#
FENCE#
OK!
FenceType:Sq
uare, ON,
Latitude1:N23
.111111,
Longitude1:E
113.123123,
Latitude2:N23
.442320,
Longitude2:E
115.232239,
in out:IN or
OUT, alarm
type:1.
Check the fence
setting
19
Set the delay
of the
defense
DEFENSE,[A]#
DEFENSE,10#
OK!
A= 1-60 (minute),
delay of the defense,
default:5 (minutes).
20
Disarm
DSRESET#
DSRESET#
OK!
DSRESET# Cancel
the current Arm status
21
Set the angle
upload
ANGLEREP,x#
ANGLEREP,ON#
OK!
X=ON/OFF,
default:ON
ANGLEREP,OFF#
OK!
ANGLEREP#
ANGLEREP:
ON
Check the anglerep
setting
22
Restore to
factory
FACTORY#
FACTORY#
OK!
The terminal
will restart
after 60s!
Restore to factory
setting
23
Reboot
RESET#
RESET#
The device
would reboot
in 20S after
receiving the
command.
Reboot the device

Query command
1
Check position
status
WHERE#
WHERE#
Current
position!Lat:N
23.168617,Lo
n:E23.168617,
Course:0,Spee
d:0KM/H,Dat
eTime:2020-
01-06
10:52:49
Query
the
address
2
Check URL
URL#
URL#
<08-16
16:30>http://
maps.google.c
om/maps?q=N
23.168629,E1
13.433510
Query
the
address
google
maps link
3
Check
parameters
PARAM#
PARAM#
IMEI:8663230
41683557;TI
MER:10,10;H
BT:3;SOS:,,;C
enter Number
:;Defense
time:10;Time
Zone:E,8,0;
UTC:ON;AP
N:cmnet,,;
Server:1,www
.whatsgps.com
,6801,0;
Query
the
paramete
rs
4
Check status
STATUS#
STATUS#
External
power:ON,11.
81V;GPRS:Li
nk Up;GSM
Signal
Level:H;
GPS:Successf
ul positioning;
SVS Used in
fix:8(10);
GPS Signal
Level:14,16,2
1,16,18,19,15,
30 ACC:OFF;
Defense:ON;R
elay:Enable
Query
the status

5
Check version
VERSION#
VERSION#
VERSION:S1
02T
FA80V3A50L
9 (2019-12-
28)(1495AD5)
,Dec 28
2019,13:29:21
,MAUI.11C.
W13.52.SP3.
V2.L9(112510
28),2019/11/2
5 10:28
Query
the
version
6
Check ICCID
ICCID#
ICCID#
IMEI:***,IMS
I:***,ICCID:*
**
Query
ICCID
and
return the
ICCID
code of
the SIM
card used
by the
device
Remote control User Manual
()
, /
-
: /
/
/
/
: /

: / /
. /
/
. / , /
-
. / , /
. / , /
/
.
,
/
/ /
.
, , /
. / / ,
. % ,
.
, /
/

. ,
,
, /
.
. / /
/:
(
)
:
:
:
/ /
/
:
/
/
GPS

USER MANUAL ENGLISH
When you park the bike and turn off key. The bike engine will lock automatically with alarm mode.
Lock Button: press once and bike will lock with alarm.
Press and hold for 2 seconds. Indicator will flash without sound.
And bike will lock without alarm.
Unlock Button: Press once and bike will unlock with sound, also
engine will be locked if engine was started.
Press and hold unlock button for 2 seconds, bike will unlock
without sound and engine will be locked without any sound (If
engine was started)
Ignition Button: Without pressing ignition button bike will never
start. Press once the ignition button after turn on the key, bike can
be started (You will hear a sound).
Press twice ignition button bike will be automatic ignition on
without the main key. Now you can start the bike without main key.
Finder button: If you cannot find your motorbike in very crowd
place. Press the finder button. And bike indicator will flash 5 times
and alarm will beep 5 times. You can find your bike.
Combination of buttons:
Turn on Indicator Beep: Turn of bike key, now press and hold
ignition button and press unlock 3 times.
Turn off Indicator Beep: Turn of bike key, now press and hold
ignition button and press unlock 4 times.
Sensitivity Control: Turn of bike key, now press and hold ignition
button and press lock 1 time. You can hear a beep. Press lock 2
times, you will hear 2 beeps. This way you can control the sensitivity
modes. 5 beeps are most sensitive.
Lock the motorbike while running with alarm: When running the

Bike, just press the lock button of remote within the range, and
bike will be locked with alarm.
Lock the motorbike while running without alarm: While running
motorbike, press and hold the unlock button for 3 seconds, and
the bike will be locked without any sound.
Factory reset: Turn on the bike key, Press and hold ignition key
and press lock button 15 times. You will hear music. That’s mean
the remote system is now default factory reset.
We provide 2 remotes, if one lost or broken, you can use the backup
One.
Some Special Features:
Hazard Light ON/OFF: Press and hold ignition button for 5
seconds, 4 indicator lights will be on until you press ignition
button once again.
Thank you for choosing TASS GPS
Chatting: www.facebook.com/TASSLOCK
Call: +8801681090909 www.tasslock.com
Dhaka, Bangladesh