TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0)4194 98811-88 Subject to technical changes.
Product information
Door release relay for
location-independent installation
TOER2-EB
Safety instructions
WARNING!
When working on main power connections of 230 V AC, the general and regional instal-
lation and safety regulations must be met. i.e. DIN VDE 0100
The device is to be installed and commissioned only by qualified electricians!
Important note on commissioning
During the transportation, the relay might have been exposed to severe shocks. As a re-
sult, the contact might move into operating position (K1-K2 closed).
!At the beginning of the commissioning connect the TCS:BUS to the relay and to the
mains power to move the contact into its rest position.
Device overview
Technical data
supply voltage: + 24 V ± 8 %
housing: plastics
dimensions (in mm): 52 x 52 x 23
weight 25 g
Acceptable ambient temperature:-20 °C ... 50 °C
Input current (2-wire): I(a) = 1.2 mA,
input current (3-wire): I(a) = 0.4 mA
I(P) = 0.8 mA
I(Pmax) = 6.5 mA
Connecting diameter: 0,4 ... 0.8 mm
recommended length for separation: 5 ... 6 mm
TCS:BUS
connection
terminals
relay con-
nection
terminals
jumper

2 11/2015
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0)4194 98811-88 Subject to technical changes.
Field of application
The TOER2-EB is a door release relay for specific door release, if several front-door
stations and door opener are installed in one system. With the TOER2-EB the door,
which called last, is opened.
Can be used also for the evaluation of specific key functions of the indoor stations.
Can be used also to control additional bells and chimes.
With an own TCS:BUS connection for location-independent installation.
Suitable for the installation in flush-mount sockets.
Short description
potential-free relay contact closing contact, 24 V DC / 2 A
Activating the device not programmed: in case of an incoming door call
with the serial number of the TOER2-EB
programmed: additionally in case of an incoming
door release command to a specific front-door sta-
tion
Alternative activation through
programming Programming the device can be implemented only
via TCSK or configo™.
evaluation of control functions
via parallel serial number (in case of a door call, in-
ternal call and pressing the floor push-button)
door release time can be adjusted with TCSK or configo™
Factory setting: 2 sec
Installation
Notes on the installation
!Observe when installing the device outdoors:
Avoid water from entering the device by suitable measures!
Wiring diagram

11/2015 3
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0)4194 98811-88 Subject to technical changes.
Example circuit
Initial operation
Operating modes
3-wire operation: Systems with more than 10 TOER2-
EB !Remove jumper!
When using the device in 2-wire operating mode,
max. 10 TOER2-EB can be connected.
Programming
The TOER2-EB can be programmed only with the Service Device TCSK by the following
commands:
Activation through door call, internal call to the parallel
serial number and when pressing the floor push-button
at the device with the relevant serial number
Activation through door release protocol (activate as
door release relay)
Activation through control functions
(control functions 0 ... 11)

4 11/2015
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0)4194 98811-88 Subject to technical changes.
Setting the relay switch time
(between 1 and 255 s; in 1 s steps)
Abbreviations:
Ser.-No. = the serial number of the TOER2-EB
ParSNr. = the serial number for the device, to which the relay, that is to be configured new, is to be allocated to.
AS = AS address of the front-door station (value 0 ... 63).
TelSNo. = the serial number of the telephone, which sends the control function (video indoor station at *63)
StF = Number of the control function that is to be sent (0 ... 11)
Conformity
Declarations of conformity for download under www.tcsag.de > Downloads > Com-
mercial information.
Information on disposal
The adjoining symbol shows that the device has to be disposed separately from
domestic waste. The materials used are recyclable. Please do help protecting our
environment and dispose the device via a collection point for electronic scrap.
Dispose the parts of the packaging in collecting tanks for cardboard and paper
resp. plastics.
Warranty
We offer a simplified processing in case of warranty for electricians.
Please observe our standard terms and conditions of sale, available under
www.tcsag.de > Downloads > Commercial information and enclosed in our latest cata-
logue.